Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹42.5 L+₹1.8 L (4.55%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN LOWEST | |
| 3 | L3₹43.7 L+₹3.0 L (7.49%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN LOWEST | |
| 4 | L4₹45.2 L+₹4.6 L (11.3%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN LOWEST | |
| 5 | L5₹45.6 L+₹5.0 L (12.4%)Rejected-AOC | L5 | Rejected-AOC OTHER THAN LOWEST |
Tender Value
₹37.1 L
EMD Value
₹74,260
Closing Date
16 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 969 EWS
GE 969 EWS C/O 56 APO
SPL REPAIR TO CERTAIN BLDGS AT RAMPUR UNDER GE 969 EWS
2024_MES_662005_1
CA NO 969 WS - /2024-25
Open Tender
Civil Works
Item Rate
180 days
RAMPUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 969 EWS
₹74,260
Yes
11 Sept 2024
25 Jun 2024
22 Jul 2024
25 Jun 2024
16 Jul 2024
9 Jul 2024
Amount
Dismantling of plain or corrugated steel sheeting , any gauge and thickness in roof covering including Nainital or similar pattern roof covering complete all as specified and as directed.
M&L Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws,complete all as specified and as directed.
M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Dismantling wall and ceilling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/ blankets, any thickness, cover fillets etc complete all as specified and as directed.
S & F for wooden wall panelling & ceilling with tongue and groove joint 8-10 mm thick fixed to timber frame work complete all as specified and directed. Note. Timber frame work including in same item section of wooden scantling(75x50mm) Grid of frame work (600x600)mm.
Dismantling of timber scantling 40 Sqcm and over in section in any position in unframed work.
M&L for second class soft wood (Kail) clean swan timber fixed in scantling.
All as per Ser item No 7 above but except timber complete all as specified and directed. (Note : Serviceable timber obtained from ser item No 6 above to be used).
Dismantiling of timber fillets rails, posts rafter purlins etc under 40 Sqcm in section in any position in framed work complete all as specified and as directed.
S&F second class hardwood plain fillets square, rectangular in section exc 6 Sqcm & not exc 13 Sqcm complete all as specified and as directed.
Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each and removal from site complete all as specified and as directed.
Taking down chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm each with shutters (without taking off shutters from the frames). complete all as specified and as directed.
S&F 2nd Class Soft wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered put together with glue pinned at joints all as specified and as directed.
S&F 30mm thick factory made flush shutters , solid core construction , with block board core and ply wood face panels commercial type on both sides fixed to chowkhats etc complete all as specified and as directed.
M&L Single side prelam PVC sheet fixed or laid on to flush doors by using rubber based adhesive, supplying & fixing at site as per specification.
S&F 35 mm thick 2nd Soft wood glazed skeleton shutters open rebated and prepared to receive guage etc (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc and fitted to chowkats, complete all as specified and as directed.
S&F aluminium alloy powder coated aluminium door frame fixed with side hung shutters and glazing fixed with and including 5.50mm thick tinted glass fixed with rubber gasket with aluminium heading, clips frame made with aluminium box sec as appended below complete all as specified and directed (a) Frame 100x44x1.48mm thick with rawl plug (b) Middle and lock rail : 150x44x1.48mm thick (c) Bottom rail : 150x44x1.48mm thick (d) Top rail/style : 85x44x1.48mm thick (e) Aluminium beading : 0.7mm thick (f) Aluminium handle D type 150mm long, aluminium tower bolt 9.9mm dia shoot 200mm long brass mortise lock 100mm 4 leaver aluminium stopper, cleat double action floor spring hydraulically regulated made of n.less than 1.25mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass other part of steel heavy duty ( Make Sandhu ISI marked or its equivalent approved make) (g) Making good of wall surface to match with existing surface complete.
S&F Powder coated aluminium sliding windows frame with movable shutter ( sliding on minimum two PVC roller of best quality, for each shutter on three tracks with stainless steel mosquito proofing and glazing shutter and incl 5.50 mm thick glass & stainless steel wire messs fixed with neoprene rubber gasket with aluminium beading, clips,frame made with aluminium section as appended below- (i) Window frame : 63x35mm X 1.48 mm thick for two tracks. (ii) Top/bottom rail and style / rail of shutter : 19x38x1.48mm thick and over. (iii) Aluminium beading - 0.7mm thick (iv) stainless steel wire cloth 0.45mm nominal dia of wire and average width of aperature 1.40mm and fixed in aluminium window or alongwith F/Y section fixed with aluminium wire staples complete. (v) Aluminium fittings such aluminium suitable handle with auto interlocking closing (vi) Making good of wall surfaces to match with existing surfaces complete all as specified and directed.
S&F MS Cold rolled Butt hinges medium weight 100 mm long complete all as specified and as directed.
S&F 300mm long Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy complete all as specified and as directed.
S&F 300 mm size mild steel ordinary rat rail rod pattern springs including roller and roller plate complete all as specified and as directed.
S&F 200mm long Anodised Aluminium tower bolt complete all as specified and as directed.
S&F 150mm long extruded aluminium alloy handle complete all as specified and as directed.
S&F steel ventilator with top hung shutters, factory made IS 1038-1983 & IS 7452 - 1990 including hinges, peg stays with glazing bars etc with & including one shop coat of red oxide primer complete all as specified and as directed. Notes: - Glass, wire gauge shall be measured & paid separately.
Hacking out old broken glass (any thickness) size , qauality or description from wooden/steel frames etc complete all as specified and directed.
S&F 4mm thick sheet glass ordinary quality of glazing with oil putty or wooden beads in squire not exc 0.5 sqm each panes complete all as specified and directed.
S&F 4mm thick figured glass, pin head type glazing with oil putty or wooden beads in squire not exc 0.5 sqm each panes complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer including preparation of new wooden or wood based surfaces over 10cm width or girth etc all as specified and as directed.
S&F in repairs curtain rails , anodised aluminium alloy with fixing brackets , stops, rollers etc. complete all as specified and as directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for 25mm thick PCC 1:2:4 type B-O (using 12.5 graded stone aggregate) as in floors finished even and fair complete all as specified and as directed.
M&L Vitrified Ceramic tiles 10mm thick square /rectangular) polished, area of each tiles not exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 15 mm thick in CM (1:4) complete all as specified and as directed.
All as per item No 32 above but as in skirting including 10mm thick in CM 1:4 rendering as in backing coat to receive the tiles, complete all as specified and directed.
M&L Non skid coloured ceramic tiles 300x300x6-7 mm thick in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement and sand mortar (1:6), complete all as specified and as directed.
M&L for coloured glazed designer ceramic tiles 300 x 450 x 7 to 8mm thick on vertical surface as in dado/skirting and jointed in neat cement slurry and pointed with white/colour cement to match with the surface over and including 15mm thick rendering in CM (1:4) complete all as specified and directed.
S&F in repair PVC (SWR) floor trap plain with grating including jointing with solvent cement 75 mm bore complete all as specified and as directed.
S&F for repair PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors for 75 mm bore pipe, complete all as specified and as directed.
All as per above item No. 37 but 110 mm bore of pipe
S&F in repair for PVC (SWR) bend with access door inluding jointing with solvent cement 75 mm bore complete all as specified and as directed.
All as per above item No. 39 but 110 mm bore.
S&F in repairs coloured oval type wash hand basin, size 580x450 mm, wliile, flat back, irun (for Hospilal use) excluding taps,chain and plug and porcelain stopper but including brackets waste pipe 32mm, coupling etc fixed as in counter slab etc complete all as specified and directed .
S&F Brass CP central hole mixer for mixing hot & cold water screwed down for 15mm bore pipe and fixed, complete all as specified and as directed.
S&F in repair vitreous china wash down water closet pedestal pattern white excluding fixing bolts , flushing cistern and flush pipe complete but including PVC seat cover with aluminium hinges devices & EWC jet chromium plated with 1.00 mtr long PVC connection pipe complete all as specified and directed.
S&F in repair Brass CP wall mixer for mixing for mixing hot & cold water screwed down for iron pipe including of telephonic shower complete all as specified and directed.
S&F in repairs CP health faucet hand held triggered nozle and delivers a spray of water with pipe complete all as specified and as directed.
S&F in repairs PVC connection 60cm long with brass check nuts on both sides suitable for 15mm bore pipe etc complete all as specified and directed.
S&F in repairs fancy type stop valve/angle valve/concealed stop cock cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes of 15mm bore complete all as specified and as directed.
Dismantling old unserviceable RCC/PVC water tank of capacity exc 500 but n. exc 1000 ltrs cpacity including S&F PVC water storage tank of 1000 ltrs capacity HDPE double layered , cylindrical type fixed and hoisted in position on roof at any height complete with inlet/outlet of 20mm GI pipe connection including locking arrangement with ball valves high pressure with epoxy coated aluminium rod and high density plastic ball fixed as in repairs complete all as specified and directed.
S&F in repair Soap dish, vitreous China white, approximate size 160x 160x90mm fixed to plugs with chromium plated brass screws, complete all as specified and as directed.
S & F in repair Brass chromium plated shower rose 125mm size, complete all as specified and as directed.
S&F in repairs Toilet paper holder, cast copper alloy, chromium plated fixed in position, complete all as specified and as directed.
Taking up or down steel tubing and connections, for refixing or removal from site for 15mm bore pipe, complete all as specified and as directed.
Taking up or down steel tubing and connections, for refixing or removal from site for 20mm bore pipe, complete all as specified and directed.
S&F 15 mm bore galvanised steel tubes, medium grade with all fittings for water supply pipes etc fixed to walls and ceilings or laid in floors complete as specified and directed.
S&F 20 mm bore galvanised steel tubes, medium grade with all fittings for water supply pipes etc fixed to walls and ceilings or laid in floors complete as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and as directed.
S&F MS framed work as in doors or gates of angle or other sections with gusset plates, rails, braces, etc complete drilled for fixing to steel sheeting or other covering, doors, etc, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging, also fastening and fixing complete conforming to Fe-410-W complete all as specified and as directed.
Excavation in post holes each n exc 0.5 cum getting out, returning, filing in and removing earth or brocken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m in soft/loose soil and making good surface as per existing surface complete all as specified and as directed.
M&L for cement concrete 1:3:6 Type C-2 (using 40 mm graded stone aggregate) as in foundation filling in or mass concrete complete all as specified and as directed.
M&L for preparation of new previously untreated steel surface of any description (new galvanized steel surfaces) over 10 cmm in width or girth not otherwise described to receive painting by applying two coats of synthetic enamel paint over a coat of Etch primer, complete all as directed.
M&L 4mm thick veneered decoretive, Plywood grade 1 (BWR resin) with decoretive face veneers on one faces , fixed with nails to timber frame work on wall.
M&L 4mm thick veneered decoretive, Plywood grade 1 (BWR resin) with decoretive face veneers on one faces , fixed with nails to timber frame work on ceiling.
S&F second class hardwood plain fillets square, rectangular in section exc 13 Sqcm & not exc 25 Sqcm complete all as spedified and directed
Dismantling of boarding any description fixed in any position with nails.
M&L, for weather boarding of 2nd class softwood, clean sawn, plain, 20 mm thick or feather edged 15 mm to 20 mm thick and fixed with 30 mm laps complete all as specified and directed.
All as per Ser item No 66 above but except boarding complete all as specified and directed. (Note : Serviceable boarding obtained from ser item No 65 here-in-before to be used).
S&F 35 mm thick, 2nd class hardwood, plain, framed, pannelled shutters (any number of pannel) with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face venner; supplied and fitted to chowkats, complete all as specified and directed.
S&F 30mm thick 2nd class hard wood glazed & skeleton window shutter open rebated and prepared to receive glass or wire mesh gauge etc (without sash bars) edges of framings plain, chamfered or rounded, fitted with cut and mitred beads for securiny glass etc size of members of shutters as specified in SSR Part-II section 8 clause 8.23(b)
S&F 35mm thick 2nd class hardwood glazed & skeleton shutter open rebated and prepared to receive glass or wire mesh gauge etc (without sash bars) edges of framings plain, chamfered or rounded, fitted with cut and mitred beads for securiny glass etc size of members of shutters as specified in SSR Part-II section 8 clause 8.23(b) complete all as specified and directed.
S&F 75mm size MS butt hinges medium weight cold rolled complete all as specified and directed.
S&F 150mm length aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 100mm length aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 75mm length aluminium anodised handle cast type complete all as specified and directed.
S&F 250mm long aluminium alloy, anodised, sliding door bolts plate type stove enameled black with bright bolts not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple complete all as specified and directed.
S&F Galvanised mild steel wire cloth 0.63mm nominal dia of wire and average width of aperture 1.4mm and fixed with tinned tacks or glavanised wire staples
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M & L for hardcore of gauge not exc 63mm , deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface with broken stone or boulders complete all as specified and as directed.
M & L for 75 mm thick cement concrete type C-1, 1:3:6 using 20 mm graded stone aggregate as in path/pavings/plinth protection etc laid in bays including finishing the concrete surface even and smooth without using extra cement complete all as specified.
Demolition of brick work built in CM or cement lime mortar complete all as specified.
M&L for walling or random rubble,uncoursed well bounded bedded and solidly hearted, built in cement mortar 1:6. Complete all as specified and directed by Engineer-In-Charge.
Rendering 20 mm thick on stone walling surfaces finished even and smooth with using extra cement in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc incl raking out joints, hacking for key screbbing down with water etc
Rendering 15 mm thick on stone walling surfaces finished even and smooth with using extra cement in cement morta 1:4 complete all as specified and directed.
Preparation surfaces, plastered or unplastered new surfaces on wall and applying two coats of cement base pain complete all as specified and directed.
Applying one coat of synthetic enamel paint on old painted wooden surfaces of any description exc 10cm width or girth including preparation of surfaces etc complete all as specified and directed.
Preparation of new wooden surfaces of any description, not otherwise described, over 10cm width or girth, applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
S&F mild steel plates wind ties for roof incl securing bolts and work confiring to Fe-290 Gde E-165.
S&F for Aluminium anodised Brackets fixed in repair for item 92
Steel work as in post including special shaped washer etc complete using ERW or inclusion butt welded tubes conforming to I. S.161- 1979 grade St.-240 complete all as specified and directed.
S&F for Fe 410-W(Gde-E- 250) quality-A Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.
Applying two coats of synthetic enemal painting over one coat of red oxide primer including preparation of new steel/iron surfaces, all as specified.
Applying one coat of synthetic enamel paint on old painted steel surfaces as in walls / roof trusses/purlins/rafters/angle iron posts etc complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc.
M&L for point wiring in PVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor.
(a) One light point/fan point/Ex fan point controlled by one 5 Amps switch one way
(b) One 3 pin 5 Amp switch socket outlet on same board with accessories
(b) One 3 pin 5 Amp switch socket outlet on independent board
S&F switch modular single pole one way 6 amp 240 volts, complete all as specified and as directed.
S&F Modular socket 6A - 2/3 pin combined 2 module,2 in 1, 3 pin,complete all as specified and as directed.
M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor.
S&F switch modular type single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed.
S&F Modular Socket, 6A/16A - 2/3pin combined 2 module, 2 in 1, 3 pin, 16 Amps complete all as specified and as directed.
S&F in repair White cover plate with frame, 2 module complete all as specified and as directed.
S&F in repair White cover plate with frame, 3 module complete all as specified and as directed.
S&F in repair White cover plate with frame, 4 module complete all as specified and as directed.
S&F in repair White cover plate with frame, 6 module complete all as specified and as directed.
S&F in repair White cover plate with frame, 8 module complete all as specified and as directed.
Supply and fixing LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.
S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed.
S&F Ceiling rose, 3 Terminal/PVC/ polycarbonate, isolated body complete all as specified and as directed.
M&L sub main wiring with two run single core 4 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia PVC conduit/casing caping, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed. Note: Two runs of 4 sqmm and one run of 4 sqmm cable and one run of casing capping shall be measured as one RM
S&F 1100 V grade heavy duty U/G cable with PVC insulated aluminium conductor served with an inner sheathing of pvc tape and overall pvc sheathed one twin core cable flat or circular of size 25 Sqmmx 4 Core all as specified and as directed.
S&F 1100 V grade heavy duty U/G cable with PVC insulated aluminium conductor served with an inner sheathing of pvc tape and overall pvc sheathed one twin core cable flat or circular of size 16 Sqmmx 2 Core all as specified and as directed.
S&F in repairs Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 12 ways, 240 V with 200 Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed.
S&F in repairs Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200 Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed.
S&F in repairs MCB, SPN 63 Amps 240 Volts C curve, complete all as specified and as directed.
S&F in repairs MCB, SPN 32 Amps 240 Volts C curve, complete all as specified and as directed.
S&F MCB SP 6 to 32 Amps, 240 Volts, 'C' Curve complete all as specified and as directed.
Supply and fix LED inverter Bulb 12 Watt.
S&F Bulkhead luminaire comprising of high brightness LEDs 9/10W LED, IP-65/66 complete all as specified and as directed.
S&F electric water heater, storage type vertical type outer body Engineering Thermoplastic with puf injected type insulation, Steel tank with glass lined coating inner tank and heating element (copper tube) upto 2 KW capacity 25 litre, 230 Volts AC Single phase BEE 5 Star rated complete with all accessories such as FR Grade 3 core PVC Cord, multifunctional safety valve, thermostate, connection piece etc, complete all as specified and as directed. Note : Internal water supply upto service connection will be measured and paid separately under B/R item.
S&F round/square shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200mm complete all as specified and as directed.
S&F for VTPN with MCCB 100 Amps 4 pole 36 KA, complete all as specified and as directed.
M&L in repairs for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia Gl pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note:- The rate is inclusive of neccessary earth work, RFR and removal etc.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundations, laying of pipes etc not exceeding 10sqm on plan for manholes etc and not exceeding 1.5 metre in depth and getting out in any type of soil, complete all as specified and as directed.
Retuning, filling in, including spreading, leveling watering and well ramming in layers not exc 25cm in hard/dense soil, complete all as specified and as directed.
Removing excavated material not exceeding 50mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and as directed.
Supply and laying of burnt clay building bricks, sub-class B (old size) Designnation 75 laid flat in tranches for cable protection with wide equal to length of brick, complete all as specified and as directed.
M&L for dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15cm thick after laying the cable all as specified in clause 19.75 of MES schedule part-1 Note:- Sand shall be fine sand as specified for plastering, Punned thickness of sand shall be measured for cushioning of cables.
Note:- Schedule of credit Rs 1,09,425.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
MS QADRI BUILDERS
M/s ABDUL AHAD AND SONS
ALI MOHD NAJAR
M/S KULWANT SINGH RAINA AND CO
ANUSHA ENTERPRISES
M/S SUMJI BROTHERS
M/S ESS EMM ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .