Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC 64 250 2 COD ROAD HASTINAPURI MADHU NAGAR AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.5 L+₹1.2 L (8.16%)Rejected-AOC 43 VIMAL ENCLAVE CHAMRAULI MODE SHAMSHABAD ROAD AGRA UP 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-AOC L2 |
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
22 Jan 2022, 6:00 pmClosed
GE Bharatpur
GE Bharatpur, Kanjoli line
SPL REPAIR REPLACEMENT OF OLD UNSV INTERNAL WIRING MCB DB SUBMAIN WIRING AND OLD TUBE LIGHTS WITH LED LIGHTS IN CHITTOR HOUSE SHIVAJI HOUSE AND NALANDA HOUSE AT RMS DHOLPUR
2021_MES_477643_2
8095/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Bharatpur
As per tender Documents
6 documents required · 6 mandatory
₹500
Yes
GE Bharatpur
₹34,000
Yes
22 Feb 2022
30 Dec 2021
24 Jan 2022
30 Dec 2021
22 Jan 2022
10 Jan 2022
1 Jan 2022 - 7 Jan 2022
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete fittings such as switches, ceiling roses, pendents, regulators, sockets etc removing materials for taking credit and making good disturbed surfaces of wall, floor & ceiling etc. complete all as specified and directed.
Dismantlingof old U/S rusted main switch/DB of any size capacity and make. complete all as specified and directed.
M&L point wiring for concealed wiring complete including cutting stone masonry wall of cadets hostel of new campus area (hilly) by using suitable grinder/cutter without damaging the existing other assets carefully (shall be borne by the contractor if any kind of assets damaged during the execution of work) with 1.5 Sqmm 02 x single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in 20mm dia PVC conduit pipes with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed inside the wall/ceiling by means of PVC conduit pipes and making good of distrub surface cement mortar /cemant based putti including making same colour as existing and suitable accessories including suitable size of PVC boards/existing sunken box with Hylem board for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm insulated but unsheathed copper earth continuity conductor to common earth and connedcted to earth dolly complete and (making temporary connection by the contractor to the cadets for their night stay on bed before leaving the work site) all as specified and directed for the following :- 3.01 One light point controlled by one way switch.
One ceiling fan/exhaust fan point controlled by one way switch. complete all as specified and directed.
One 3 pin or 5 pin 6 Amp socket point outlet on the same board with other switches complete all as specified and directed.
One 3 pin or 5 pin 6 Amp socket point outlet on the independent board complete all as specified and directed.
All as per item No 4 above but with multi stranded copper conductor cable 4 Sqmm size for 3/5 pin 16 Amps socket point outlet on independent board including 4 Sqmm copper cable PVC insulated FRLS unsheathed copper continuous earth wire including connecting to common earth dolly complete all as specified and directed.
S&F switch piano flush button single pole one way 6 Amps 230 volt grade complete all as specified and directed.
S&F switch piano flush button single pole one way 15 Amps 230 volt grade complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin, 5 Amp flush type multi purpose, complete all as specified and directed.
S&F socket outlet 2 in 1, 6 pin, 15 Amp flush type multi purpose, complete all as specified and directed.
S&F ceiling rose surface bakelite 50 x 40 mm three terminal ISI marked including suitable size of PVC board . complete all as specified and directed.
S&F step type electronic fan regulator EME type 450 watt make : Anchor code No 50440 penta or equivelent mentioned in appx ''B ' complete all as specified and directed.
M&L submain wiring complete with 4 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 4 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit/sleeves with all PVC accessories fixed on wall, floor/ceiling etc.including taking down existing unservicable conduit complete all as specified and directed. Note: Two run of 4 Sqmm cable, one run of 4 Sqmm cable and PVC conduit pipe shall be measured as a one length only.
M&L for cutting wall and flushing for TPN DB 4 way factory made and OK tested made of sheet metal enclosure powder coated suitable for mounting MCB TPN 4way, 415V, with 200Amps rateded bus bar, double door type, including making good the wall as per existing position after ceneting/plastering/applying putty and distembering etc complete all as specified and directed.
M&L for cutting wall and flushing in Distribution board factory made and tested made of sheet metal enclosure powder coated suitable for mounting the MCB 240 volt of 12 way SPN with200 Amp rated busbar 240 volts (double door type) complete all as specified and directed.
M&L for cutting wall and flushing in Distribution board factory made and tested made of sheet metal enclosure powder coated suitable for mounting the MCB 240 volt of 8 way SPN with200 Amp rated busbar 240 volts (double door type) complete all as specified and directed.
S&F MCB 240 volts 10 KA, rupturing capacity fixed in DB's of the undermentioned type and rating. complete all as specified and directed. 15.01 MCB SP 240 volts 5-32 Amps
MCB SPN 240 volts, 40 Amps, 10KA
MCB TPN 415V, 63Amps, 10KA
S & F LED light fittings 1x20watt 220 watt AC decorative box type with driver holder including LED tube light connecting up with three core flexible cable of sutiable size from ceiling rose complete all as specified and directed.
M&L batten/angle holder insulated with back plate including suitable size of PVC round block make Anchor code No 51205 or equivalent make mention in appendix 'B ;complete all as specified and directed .
S&F LED bulb 14W cool day light , in-built voltage surge protection > 3.5kV, single ph, 230V, luminous efficacy 100Lm/Watt, base B22, min 3 star rated all as specified and as directed . Make - CG or equivalent make mention in Appx 'B'
Supply & Fixing of LED based Street light , housing made up of pressure die cast aluminium Alloy with effective thermal magnet sturdiness. The fixture should have a minimum system efficiency more of more than 80 lumen/Watt and a minimum system lumen output of not less than 7200 lumens and maximum system wattage 72Watts. The fixture shall have correlated colour temperature of atleast 5000K and a CRI of minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance. Ingress protection of IP 66 (lamp and gear Compartment and mechanical impact resistance rating ofIK >= 05. The fixture driver should have an operating voltage range 140-270 V, surge protection not less than 4KV, PF > 0.95 and THD < 15%. The fixture should comply to IEC 61000-3-2 ed 3.2 per harmonics IEC 61347-2-3 2006 in configuration with IEC 61347-1 ed 2.0, 2007 for electrical safety LM 79 and LM 80 test report needs to be submitted from NABL. The driver should have double phase protection. LED Light fitting should be suitable for ambient temperature from (-) 10 deg C to (+) 50 deg C as per IS 10322 and for EMI and LM 79 test reports , including making modification to existing street light bracket for fixing LED light if required , with suitable size clamp, nut bolts and washers as per site requirement complete all as specified and as directed (Note:- The manufacture of LED fitting shall give Guarantee for 2 Years from the date of installation). make - Havells cat pt No ENDURACITYLINERNEOSL70WLED757PASYBOTG or equivalent in Phillips, CG, Wipro and Syska.
M & L earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe light grade 15 mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed.
S&L pipe galvanised medium grade complete including fittings sizes of 40mm dia complete all as specified and directed.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trench or inside the existing pipes or fixed on pole/wall with GI clamps and clips of the following sizes:- including taking down Old U/S cable Note: Excavation and earthwork if require shall be measured and paid seprately. 22.01 10 Sqmm 2 core
50 Sqmm 3 1/2 core
S&F water heater (geyser) storage type 25Ltr capacity 5 star rated, complete with hot and cold pipe, PVC 15mm bore with PTMT coupling clamping accessories, necessary hold fasts, flusinhg in the bolt, hanging of geyser on wall, plumbing works, including 15 mm bore CP brass bib cock, vertically mounted, including 2.5mtr 3 core cable of suitable size, complete all as specified and directed.CAT Part No GHWEMESWH035, make Havells or equivalent in Bajaj/CG only. Note: Rate incl dismantling of old UNSV geyser from wall and handover to E/M store I/C at SDO(MES) Dholpur for making necessary entries in relevent ledger for further action.
S&F in replacement and Taking up or down the existing unserviceable GI steel tubing and connection and S&F new galvanised, steel water tubing, medium grade with all fittings complete to walls and ceilings or laid in floors of following sizes, complete all as specified and directed. 24.01 15mm bore.
20mm bore.
M&L for removing unserviceable grouted "Anchor" type bolts and nuts from the wall and S&F new "Anchor" type bolts not less than 16mm dia, 100mm length(min) grouted properly in wall to hold 25/35/50 ltr capacity water storage type geyser with and including nuts and washers and making good the disturbed surface in cement mortar 1:3 complete all as specified and directed.
S&F in repair PVC connection hot & cold type, 15mm dia, 60cm long with PTMT coupling complete all as specified and directed.
S&F in repairs stop valve, cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions of 15mm bore, ISI marked. complete all as specified and directed.
S&F sheet metal enclosure of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps, 240 volts. complete all as specified and directed..
Taking out old UNSV exhaust fan any type and size complete, demolition/cutting of stone/concrete/brick wall , taking out all kind of connections and anchor bolts etc complete all as specified and directed.
S&F exhaust fan 300mm sweep turbo force SP, 1400 RPM, single phase, 230V with complete accessories including cutting/pinning/demolition of any type of wall upto the required size of exhaust fan, make good the wall after fixing the exhaust fan as per existing position including plastering, applying putty and wall painting/distembering etc and making provision of wire mesh for the protection of interior area from insects/monkeys or any ruptiles etc. complete all as specified and directed.
Supply and fix MCCB 4 Pole, 415 V, with Microprocessor release 250 Amps with breaking capacity 36 KA complete all as specified and directed.
Supply and fix MCCB 4 Pole, 415 V, with Microprocessor release 160 Amps with breaking capacity 36 KA complete all as specified and directed.
Supply and fix MCCB 4 Pole, 415 V, with Microprocessor release 400 Amps with breaking capacity 36 KA complete all as specified and directed.
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out/laying LT UG cable, and getting out in hard disintegrated rock complete all as specified and directed.
Removing excavation soil at a distance not exc 50 m and deposited where complete all as specified and directed.
Returning,filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Supply and laying of unburnt Sub class B Bricks in trenches over the LT/HT cables for the protection of cables, laid across the length complete all as specified and directed.
M &L local river sand for bedding and sand cushioning of all HT/LT UG cable complete all as specified and directed.
supply and fix of ^lithium based Energy Efficient Integrated solar street light of 32 watt ^ in single FRP body duly polyurethane coating(camouflage colour),encases with monocrystalline solar PV panel of 65-67 Wp ,lithium battery 11.1/12.8 v 33 AH with inbuilt BMS IP 65 high brightness W-LED (160/180 lm /watt) lamp with aluminium reflector for better light distrubtion CRI>70 colour temperature 5700-6500K . microcontroller basedcharge controller cum driver automatic diming function (frist four hour at full brightness and rest of the time at lower light level with PIR motion sensor dusk to dawn operation sutiable to working temperature -10 to 55 C .weight not more than 14-16 kg with adjustiable MS clamp sutiable for pole wall mounting etc complete as required protection-short circuit overload reverse polarity and battery protection firm should provide vital parameter test report from NABL accredited lab and should be made in india with CE and ROHS complaint Make-Axxon-32W. or equivalent make as approve by GE complete all as specified and directed.
S S TRADERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .