EXECUTIVE ENGINEER PMU
EXECUTIVE ENGINEER PROJECT MANGEMENT UNIT VYDHYUTHI BHAVANAM GANDHI ROAD KSEBL
CONSTRUCTION OF NEW UG FEEDER FROM PROPOSED PANTHEERANKAVU SUBSTATION-OLAVANNA FEEDER UNDER ELECTRICAL SECTION PANTHEERANKAVU
2026_KSEB_879973_1
PMU/KKD/e-Tender/40/2026-27 Dtd 19-10-2026
Open Tender
Electrical Works
Percentage
240 days
PANTHEERANKAVU
Please refer Tender documents.
8 documents required · 8 mandatory
₹5,900
₹50,000
KOZHIKODE
19 Oct 2026
19 Oct 2026
31 Oct 2026
19 Oct 2026
28 Oct 2026
19 Oct 2026
19 Oct 2026 - 28 Oct 2026
26 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Laying of 11 KV XLPE UG cable of various sizes after providing HDD Duct along / across roads and other public paths by mechanical means including supply of HDPE pipe 110mm dia, making exit/ entry pits of suitable sizes | 9,000 | m | 1,500 | ₹1,35,00,000 |
| 2 | Transporting UG Cable | 20 | E | 17,828 | ₹3,56,560 |
| 3 | Transporting Transformers by hired vehicle to a distance upto 5km and carrying upto 2 numbers of 63/100/160/250kVA Transformers / Ring Main Units excluding loading& unloading charges. | 6 | Trip | 3,142.26 | ₹18,853.56 |
| 4 | Approved Data: Lifting / Loading 1No CCC/CCV unit of RMU from its place of storage / existing location vehicle suitable location for a distance upto 50m | 8 | No | 3,402.32 | ₹27,218.56 |
| 5 | Approved Data: Lifting / Loading 1No C/V/M unit of RMU from its place of storage / existing location vehicle suitable location for a distance upto 50m | 10 | No | 2,916.19 | ₹29,161.9 |
| 6 | Doing one cable end termination on HT XLPE UG cables of sizes beyond 3x185 sqmm and upto and including 3x300 sq mm using the cable jointing kit supplied departmentally after making fencing,caution board and all other safety measures including charges for cable jointer etc. complete as per the direction of the departmental officers. | 19 | No | 1,925.73 | ₹36,588.87 |
| 7 | Doing straight joint on HT XLPE UG cables of sizes beyond 3x185 sqmm and upto and including 3x300 sq mm using the cable jointing kit supplied departmentally as per specification after providing proper traffic signalling and caution board fencing etc. wherever necessary, including charges for cable jointer and other sundries etc. as per the direction of departmental officers at site. | 40 | No | 3,229.41 | ₹1,29,176.4 |
| 8 | Transporting Transformers by hired vehicle to a distance beyond 5km and carrying upto 2 numbers of 63/100/160/250kVA Transformers / Ring Main Units (Running km). | 30 | km | 103.5 | ₹3,105 |
| 9 | Cost of construction of foundation, base plates, fixing anchor bots, loading & unloading, handling, erection, allignment and allied works for the installation of Data Aquisition compatible Extensible type Ring Main Units with terminal protector boots & extension modules, actuators for remote operatios, communicable FPIs, CTs, PTs & relay contacts for SCADA, giving power & control wiring and connections, providing terminal protector, interconnecting RMU bus bar and control cables, providing metered LT supply from nearest LT pole, providing earth leads, cable mounting & terminations, giving connections after ascertaing proper phase sequence, providing location name & warning boards, burying cables & refilling, conducting all precommissioning tests as required, complete, except cost of conveyance. RMUs with two nos load break switches & one VCB | 4 | No | 56,355.23 | ₹2,25,420.92 |
| 10 | Cost of construction of foundation, base plates, fixing anchor bots, loading & unloading, handling, erection, allignment and allied works for the installation of Data Aquisition compatible Extensible type Ring Main Units with terminal protector boots & extension modules, actuators for remote operatios, communicable FPIs, CTs, PTs & relay contacts for SCADA, giving power & control wiring and connections, providing terminal protector, interconnecting RMU bus bar and control cables, providing metered LT supply from nearest LT pole, providing earth leads, cable mounting & terminations, giving connections after ascertaing proper phase sequence, providing location name & warning boards, burying cables & refilling, conducting all precommissioning tests as required, complete, except cost of conveyance. Additional rate for RMUs with one additional Load Break switch / VCB | 1 | No | 14,202.5 | ₹14,202.5 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BIDDOCUMENTNEW.pdf
Tender Documents • 0.74 MB
LOCATIONSKETCH.pdf
Other Document • 0.44 MB
BOQ_1496242.xls
BOQ • 0.26 MB
OTHERIMPORTANTDETAILS.pdf
Additional Documents • 0.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .