Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹32,466
Closing Date
6 Oct 2026, 2:00 pm
EE II CKHED
OFFICE OF THE EXECUTIVE ENGINEER, P.W.Dte. Central Kolkata Health Electrical Division P-12, C.I.T Road(1st floor) KOLKATA
Repairing and renovation of Electrical Installation Works for Plastic OT at Ground Floor Baker Building under the NRS Medical College and Hospital, Kolkata..SITC of AC machine
2026_WBPWD_5021822_1
WBPWD/EE-II/CKHED/eNIT07/26-27 3rd call
Open Tender
ELECTRICAL WORKS ORG
Item Rate
NRS MCH
Please refer Tender documents.
5 documents required · 5 mandatory
₹32,466
central kolkata health electrical division
6 Oct 2026
2 Sept 2026
8 Oct 2026
2 Sept 2026
6 Oct 2026
8 Sept 2026
28 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, Installation, Testing and Commissioning cooled ducted split type air conditioning machine with each having a capacity and details as mentioned below suitable for operation on R 32/R-410A /R-407 Green refrigerant comprising of Scroll type compressor hermatically sealed complete with automatic capacity, safety switches, lubrication system with min 5 year (OEM) warranty for both compressor and Printed Circuit Board (PCB) , Suitable capacity squirrel cage induction motor having class 'B' insulation suitable for operation on 415 + 10% volts, 50 Hz,A.C. supply for Blower motor, Necessary drive arrangement for blower motor, Matching Air-cooled condenser with necessary fittings for refrigerant piping connections, necessary structural support for mounting condensers, Microprocessor based control panel complete with accessories, machine Isolation / disconnect switch, valves and accessories to inter connect compressor and condenser including pressure testing, vacuum. Necessary starters suitable for Indoor & outdoor unit complete with O/L,U/V, phase reversal protection, single phase preventors i/c copper conductor control and power cable and drain pipe of suitable size and length etc complete as required. The total cooling capacity/heating capacity of tested unit shall have a capacity as per relevant IS code. The lab testing reports as per IS: 8148 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per ISO/International Electrotechnical Commission (IEC) 17025 standards / Central Power Research Institute (CPRI)/Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification as required. | - | - | - | - |
| 2 | a) 4.0 TR (3.2 EER) (Main OT) | 4 | Nos. | - | - |
| 3 | b) 2.2 TR (BEE 4 Star Rated)(Doctors Room:1,Recovery Room:1,Sister room:1,Class Room: 3) | 6 | Nos. | - | - |
| 4 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for Concled split AC system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required | - | - | - | - |
| 5 | a) 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 175 | Mtr | - | - |
| 6 | b) 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2
mm | 175 | Mtr | - | - |
| 7 | Supply of XLPE Insulated & unarmoured stranded Copper Conductor control cables h aving following numbers of core for Working Voltage up to 1100 Volts of following sizes [Make Polycab / RR /KE!/ Havells/ Gloster as approved by E.I.C] | - | - | - | - |
| 8 | a) 4 core 2.5 sq.mm communication cable | 175 | Mtr | - | - |
| 9 | S & L of Drain Water piping work out of PVC / HDPE hard pipes of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors. | - | - | - | - |
| 10 | a) 32 mm dia | 75 | Mtrs. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
Tendernotice_2.pdf
PDF • 0.23 MB
CKHEDPWDMakeList.pdf
Tender Documents • 0.10 MB
BOQ_5101074.xls
BOQ • 0.26 MB
2911.pdf
Other Document • 0.50 MB
datecorri.pdf
PDF • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .