Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC | L1 | Accepted-AOC Lowest offer | |
| 2 | L2₹18.5 L+₹13,750 (0.75%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹18.6 L+₹23,750 (1.30%)Rejected-Finance 276 6 GK COMPLEX AYYALU MEENAKSHI NAGAR UDUMAIPET TIRUPUR 642128 | TIRUPPUR | TAMIL NADU | 642128 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹20.5 L+₹2.1 L (11.7%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹35.1 L+₹16.7 L (91.2%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | Universal Insulation L5 | CROWN ENTERPRISES L3 | Gopalan sthanu krishnan L2 | MAARUTHI BUILDERS L4 | MACRO ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | SUPPLY AND FIXING OF RAISED ACCESS FLOORING ( FALSE FLOORING) AS PER THE FOLLOWING SPECIFICATIONS AND AS PER ENCLOSED DRAWING.
FALSE FLOOR: THE SYSTEM SHOULD BE OF NOMINAL 600MM X 600MM (35MM THICK) MODULAR PANELS WITH HEAVY-DUTY PEDESTALS.THE FINISHED FLOOR HEIGHT SHALL BE MAXIMUM 700MM FROM THE CONCRETE BASE. THE TOTAL SYSTEM WEIGHT SHALL NOT EXCEED 40 KG/SQ.M. THE SYSTEM SHALL BE ABLE TO WITHSTAND A UDL OF 1900 KG/SQ.M AND A POINT LOAD OF 363 KG AS PER CISCA TESTING STANDARDS 2007.
PANEL: PANELS SHALL BE MADE OF STEEL WITH AN INFILL OF LIGHTWEIGHT, NON-COMBUSTIBLE HAVING FIRE RESISTANCE, THERMAL INSULATION, AND FLAME RESISTANCE PROPERTIES AT 60 MIN CEMENTITIOUS MATERIAL. THE BOTTOM OF THE PANEL SHALL BE EMBOSSED IN 49 HEMISPHERICAL SHAPE CONES AND 36 INVERTED CONES.THE TOP PLAIN SHEET IS FUSE WELDING AT THE BOTTOM PAN AT IN 117 LOCATIONS TO FORM A PANEL OF OVERALL THICKNESS OF 35MM WHICH INCLUDES A 1MM THICKNESS ANTI-STATIC HIGH PRESSURE LAMINATE ( HPL ) FINISH AT THE TOP AND FINISHED ON ALL FOUR SIDES WITH EDGE PROTECTIVE PVC BEADING.THE 12.5MM FLANGE ON THE PERIMETER IS PROVIDED WITH FOLDED GUSSETS AT THE FOUR CORNERS.
THE ENTIRE PANEL SHALL BE COATED WITH EPOXY POWDER COATING OF 40-60 MICRONS ON THE EXPOSED SURFACE TO ENSURE CORROSION RESISTANCE.
PEDESTAL: PEDESTAL BASE SHALL BE SQUARE OF 100MM X 100MM X 2MM BEARING AREA AND ASSEMBLE TO A TUBE OF 22MM DIA WITH 2MM WALL THICKNESS. THE PEDESTAL HEAD SHOULD NOT BE LESS THAN 3MM THICK. THE PEDESTALS SHOULD BE ABLE TO ACCEPT AN AXIAL LOAD OF 22,500N . THE BASE PEDESTAL WILL HAVE A POLYCARBONATE BUSH TO ENGAGE WITH THE THREADED POSITION OF PEDESTAL HEAD .THE STUD SHALL FIT SNUGLY IN THE BUSH TO AVOID LATERIAL MOVEMENT OF THE PEDESTAL HEAD AND AVOID RATTLING NOISE.THE PEDESTAL COMPONENT SHALL BE ZINC ELECTRO PLATED. HEIGHT OF PEDESTAL SHALL BE APPROXIMATE 700 MM FOR FLOOR.
STRINGER: THE STRINGER SHALL BE OF 565MM LENGTH X 20MM WIDE X 32MM HEIGHT. STRINGERS SHALL BE INDIVIDUAL AND RIGIDLY FASTENED TO THE PEDESTALS WITH FASTENERS.
NOTE: THE FALSE FLOOR SYSTEM SHALL BE TESTED AS PER CISCA STANDARDS 2007 FOR POINT LOAD, UNIFORM LOAD, ULTIMATE LOAD AND PEDESTAL AXIAL LOAD. TEST CERTIFICATE SHALL BE PROVIDED. | 450 | SQM | 7,900 ₹35,55,000 | 7,250 ₹32,62,500 | 5,100 ₹22,95,000 | 7,790 ₹35,05,500 | 4,550 ₹20,47,500 Lowest |
| Sl.NoBidder Name | ||||||||
| 1 | MACRO ENTERPRISES (BID ID -1460584) | 20,47,500 | Not Quoted | - | - | - | - | - |
| 2 | MAARUTHI BUILDERS (BID ID -1461384) | 20,47,500 | Not Quoted | - | - | - | - | - |
| 3 | CROWN ENTERPRISES (BID ID -1462443) | 20,47,500 | 1857500.00 | - | - | - | - | - |
| 4 | Universal Insulation (BID ID -1460675) | 20,47,500 | 1847500.00 | - | - | - | - | - |
| 5 | Gopalan sthanu krishnan (BID ID -1457327) | 20,47,500 | 1837500.00 | - | - | - | - | - |
Tender Value
Refer Docs
EMD Value
₹57,000
Closing Date
17 Sept 2025, 3:00 pmClosed
General Manager, Projects
PMD Office, TNPL Unit I, Kagithapuram.
Supply and installation of false flooring for control panel and I/O rack rooms in RSPS#2 Project at TNPL Unit I
2025_TNPL_602732_1
TNPL/PMD/CIV/RSPS#2/UNIT I/252613004219
Open Tender
Civil Works
Tender cum Auction
60 days
TNPL Unit I, Kagithapuram, Karur District
As per Invitation for Bids of Bid Document
5 documents required · 5 mandatory
₹0
₹57,000
9 Oct 2025
11 Sept 2025
18 Sept 2025
11 Sept 2025
17 Sept 2025
11 Sept 2025
Amount
SUPPLY AND FIXING OF RAISED ACCESS FLOORING ( FALSE FLOORING) AS PER THE FOLLOWING SPECIFICATIONS AND AS PER ENCLOSED DRAWING. FALSE FLOOR: THE SYSTEM SHOULD BE OF NOMINAL 600MM X 600MM (35MM THICK) MODULAR PANELS WITH HEAVY-DUTY PEDESTALS.THE FINISHED FLOOR HEIGHT SHALL BE MAXIMUM 700MM FROM THE CONCRETE BASE. THE TOTAL SYSTEM WEIGHT SHALL NOT EXCEED 40 KG/SQ.M. THE SYSTEM SHALL BE ABLE TO WITHSTAND A UDL OF 1900 KG/SQ.M AND A POINT LOAD OF 363 KG AS PER CISCA TESTING STANDARDS 2007. PANEL: PANELS SHALL BE MADE OF STEEL WITH AN INFILL OF LIGHTWEIGHT, NON-COMBUSTIBLE HAVING FIRE RESISTANCE, THERMAL INSULATION, AND FLAME RESISTANCE PROPERTIES AT 60 MIN CEMENTITIOUS MATERIAL. THE BOTTOM OF THE PANEL SHALL BE EMBOSSED IN 49 HEMISPHERICAL SHAPE CONES AND 36 INVERTED CONES.THE TOP PLAIN SHEET IS FUSE WELDING AT THE BOTTOM PAN AT IN 117 LOCATIONS TO FORM A PANEL OF OVERALL THICKNESS OF 35MM WHICH INCLUDES A 1MM THICKNESS ANTI-STATIC HIGH PRESSURE LAMINATE ( HPL ) FINISH AT THE TOP AND FINISHED ON ALL FOUR SIDES WITH EDGE PROTECTIVE PVC BEADING.THE 12.5MM FLANGE ON THE PERIMETER IS PROVIDED WITH FOLDED GUSSETS AT THE FOUR CORNERS. THE ENTIRE PANEL SHALL BE COATED WITH EPOXY POWDER COATING OF 40-60 MICRONS ON THE EXPOSED SURFACE TO ENSURE CORROSION RESISTANCE. PEDESTAL: PEDESTAL BASE SHALL BE SQUARE OF 100MM X 100MM X 2MM BEARING AREA AND ASSEMBLE TO A TUBE OF 22MM DIA WITH 2MM WALL THICKNESS. THE PEDESTAL HEAD SHOULD NOT BE LESS THAN 3MM THICK. THE PEDESTALS SHOULD BE ABLE TO ACCEPT AN AXIAL LOAD OF 22,500N . THE BASE PEDESTAL WILL HAVE A POLYCARBONATE BUSH TO ENGAGE WITH THE THREADED POSITION OF PEDESTAL HEAD .THE STUD SHALL FIT SNUGLY IN THE BUSH TO AVOID LATERIAL MOVEMENT OF THE PEDESTAL HEAD AND AVOID RATTLING NOISE.THE PEDESTAL COMPONENT SHALL BE ZINC ELECTRO PLATED. HEIGHT OF PEDESTAL SHALL BE APPROXIMATE 700 MM FOR FLOOR. STRINGER: THE STRINGER SHALL BE OF 565MM LENGTH X 20MM WIDE X 32MM HEIGHT. STRINGERS SHALL BE INDIVIDUAL AND RIGIDLY FASTENED TO THE PEDESTALS WITH FASTENERS. NOTE: THE FALSE FLOOR SYSTEM SHALL BE TESTED AS PER CISCA STANDARDS 2007 FOR POINT LOAD, UNIFORM LOAD, ULTIMATE LOAD AND PEDESTAL AXIAL LOAD. TEST CERTIFICATE SHALL BE PROVIDED.
Bidder Name
Amount in Words
MACRO ENTERPRISES (BID ID -1460584)
MAARUTHI BUILDERS (BID ID -1461384)
CROWN ENTERPRISES (BID ID -1462443)
Universal Insulation (BID ID -1460675)
Gopalan sthanu krishnan (BID ID -1457327)
Gopalan sthanu krishnan (BID ID -1457327)
CROWN ENTERPRISES (BID ID -1462443)
MAARUTHI BUILDERS (BID ID -1461384)
Universal Insulation (BID ID -1460675)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .