The E.E.(O&M), Sachin Division
Tenderization for ARC Work for Laying of OH XLPE with Erection of HT/LT lines , T/C & maintenance of feeders for various scheme under Sachin 1 and any other SDn if required under jurisdiction of Sachin Division Under ALL Scheme.
362782
SD/O&M/EXP/26/718 Date:03.11.2026
Open
Electrical Works
Works
Surat
6 documents required · 6 mandatory
₹1,180
Online Payment in DGVCL Sachin Division Account
₹20,000
4 Nov 2026
4 Nov 2026
4 Nov 2026
26 Nov 2026
4 Nov 2026
180 days
The statement showing items of works to be carried out for erection work of HT/LT lines , T/C ,Laying Testing &
Commissioning of XLPE UG CABLE & maintenance of feeders for various scheme for Various sub division
under the control of Sachin (O&M) Division.
HT,LT &TC Revised as per Letter No DGCS/1408/01/2025 Approved Date: 27-01-2025
Ammendment HT,LT &TC Revised as per Letter No DGCS/0693/02/2025 Approved Date: 12-02-2025
Maintenance Revised as per Letter No DGCS/1410/01/2025 Approved Date: 27-01-2025
UG Cable Revised as per Letter No DGCS/1411/01/2025 Approved Date: 27-01-2025
Name of Work :- Rate contract for erection of OH XLPE Cable with HT/LT line & T/C work for various scheme
work for SDN office under Sachin Division Office.
ITEM CODE Details of Works Qty Unit Amount
HT TAPPING FROM THE EXISTING POLE
INCLUDING FIXING OF CROSS ARMS, CLAMPS
ANTI-CLIMBING DEVICES, DANGER BOARD,
INSULATORS ETC. COMPLETE AND PAINTING OF
FABRICATED MATERIALS AND NUMBERING
COMPLETE WITH COST OF PAINTS AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
ERECTION OF PSC POLES OF 8 *200 KG
INCLUDING EXCAVATION OF PIT AND REFILLING
OF EARTH, FIXING OFCROSS ARMS, TOP FITTING
CLAMPS ANTI-CLIMBING DEVICES, INSULATORS
2 9926000002 ETC. COMPLETE AND PAINTING OF FABRICATED No. 1163
MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
ERECTION OF STEEL POLES OF 9 TO 11 METERS
INCLUDING EXCAVATION OF PIT AND REFILLING
OF EARTH, FIXING OFCROSS ARMS, TOP FITTING
CLAMPS ANTI-CLIMBING DEVICES, DANGER
BOARD, INSULATORS ETC. COMPLETE AND
PAINTING OF STEEL POLE, FABRICATED
MATERIALS USED ON THE POLEAND NUMBERING
WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF
GUY SET AND EARTHING.
ERECTION OF STEEL POLE OF 13 METERS FOR
RAILWAY CROSSING ON BG/MG/NG LINE FOR
0.400/11/22KV OVERHEAD LINES I.E INCLUDING
EXCAVATION OF PIT & REFILLING OF EARTH,
FIXING CROSS ARMS, TOP FITTING CLAMPS,ANTI-
CLIMBING DEVICES DANGER BOARD,
INSULATORS ETC. COMPLETE AND PAINTING OF
STEEL POLES, FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COSTOF
PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND
File No: DGVCLSDUR/MSC/e-file/4523/2026/1660/Billing
Approved By: Executive Engineer,Technical,DGVCLDOS
Letter No: DGVCLSDUR/0012/11/2026 Approved Date: 03-11-2026 18:10
ERECTION OF DOUBLE POLE STRUCTURE OF
METERS 200 KG PSC POLES INCLUDING
EXCAVATION OF PITS & REFILLING OF
EARTHING, FIXING OF CHANNELS, SUPPORTING
ANGLES,CLAMPS, ANTI-CLIMBING DEVICES
DANGER BOARDS,INSULATORS ETC.COMPLETE
AND PAINTING OF FABRICATED MATERIALS
USED ON THE POLES AND NUMBERING WITH
COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF
GUY SETS AND EARTHING.(WITHOUT AB
ERECTION OF DOUBLE POLE STRUCTURE OF
TO 11 METERS.STEEL POLE INCLUDING
EXCAVATION OF PITS & REFILLING OFEARTH,
FIXING OF CHANNELS, SUPPORTING ANGLES,
CLAMPS,ANTI-CLIMBING DEVICES DANGER
BOARDS, INSULATORS ETC.COMPLETE &
PAINTING OF POLES,FABRICATED
MATERIALSUSED ON THE POLES AND
NUMBERING WITH COST OF PAINTSAS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH
MOUNTING OF AB SWITCH, HG FUSES OF 8 MTRS
200 KG PSC POLES INCLUDING EXCAVATION OF
PITS AND REFILLING OF EARTH,FIXING OF
CHANNELS SUPPORTING ANGLES, CLAMPS,
ANTI-CLIMBING DEVICES, DANGER BOARDS,
INSULATORS,DOFUSES ETC. COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH COSTOF
PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDINGOF ERECTION OF GUY SET AND
EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH
MOUNTING OF AB SWITCH,HG FUSES, 9 TO
METERS STEEL POLES INCLUDING EXCAVATION
OF PITS AND REFILLING OF EARTH, FIXING
OFCHANNEL, SUPPORTING ANGLES, CLAMPS,
ANTI-CLIMBING DEVICES , DANGER BOARDS,
INSULATORS, ETC. COMPLETE AND PAINTING OF
POLES FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINT
AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND
EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURES WITH
MOUNTING OFAB SWITCH, HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX. OF 8 METERS 200 KG PSC
POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROMSTORES TO SITE, FIXING
9 9926000009 OF CHANNELS, SUPPORTING ANGLES,BRACINGS No. 9074
CROSS ARMS CLAMPS, ANTICLIMBING DEVICES
DANGER BOARDS, CONDUCTOR AND CABLE
WIRING ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USEDON THE POLES
AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SETS AND EARTHING.
File No: DGVCLSDUR/MSC/e-file/4523/2026/1660/Billing
Approved By: Executive Engineer,Technical,DGVCLDOS
Letter No: DGVCLSDUR/0012/11/2026 Approved Date: 03-11-2026 18:10
ERECTION OF DOUBLE POLE STRUCTURE WITH
MOUNTING OF AB SWITCH,HG FUSES
TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX 9 TO 11 METERS STEEL
POLES INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTH CARTING OF
TRANSFORMERS FROM STORE TO SITE,
10 9926000010 FIXINGOF CHANNELS SUPPORTING ANGLES, No. 10609
BRACING, CROSS ARMS,CLAMPS, ANTICLIMBING
DEVICES, DANGER BOARDS,CONDUCTOR AND
CABLE WIRING ETC. COMPLETE AND PAINTING
OF POLES FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTIONS OF
GUY SETS AND EARTHING.
ERECTION OF GUY SET INCLUDING EXCAVATION
OF PITS & REFILLING OF EARTH AS PER
STANDARD SPECIFICATION WITH STAY CLAMPS,
STAY WIRE, ANCHOR ROD, TURN BUCKLE,
EYEBOLT, GUY INSULATOR, CEMENT CONCRETE
BLOCK ETC. BUT EXCLUDING CONCRETING.
CONCRETING OF POLES, GUYS, ETC. INCLUDING
12 9926000012 COST OF CEMENT SAND METAL (1:2:4) AND CMT 8396
WATER ETC. AS PER STANDARD SPECIFICATION.
ERECTION OF COIL TYPE EARTHING INCLUDING
COST OF COAL,SALT ETC. BUT WITHOUT COST
OF GI WIRE AS PER STANDARD
SPECIFICATION(20kg solt+20kg coal)
ERECTION OF GI PIPE/CI PLATE TYPE EARTHING
INCLUDINGCOST OF COAL SALT ETC. BUT
14 9926000014 WITHOUT COST OF PIPE/GIPLATE GI WIRE AS No. 781
PER STANDARD SPECIFICATION.(20kg solt+20kg
ERECTION OF STREET LIGHT FIXTURE
COMPLETE WITH CLAMPS, BRASS NIPPLE,
BRASS HOLDER TECK WOOD BUSH,REFLECTORS
FUSE, WIRING ETC. AS PER STANDARD
SPECIFICATION BUT EXCLUDING COST OF
STRINGING OF ALL TYPE OF CONDUCTOR
(EXCEPT DOG CONDUCTOR) FOR 11/22KV & LT ONE COND
LINES INCLUDING FIXING OF INSULATORS, PER KM
BINDING JUMPERING ETC.
STRINGING OF GI WIRE 8 SWG INCLUDING
BINDING JUMPERING ETC.
PROVIDING SINGLE PHASE SERVICE
CONNECTION WITH PVC 4MM TWIN CORE CABLE
FROM TERMINAL POLE TO METERING POINT
18 9926000018 INCLUDING FIXING OF METER WITH METER No. 397
EARTHING COMPLETE WORK AS PER STANDARD
SPECIFICATION BUT EXCLUDING COST OF
PROVIDING THREE PHASE 4 WIRE SERVICE
CONNECTION WITH PVC 4MM2/10MM2 FOUR
CORE CABLE FROM TERMINAL POLE TO
19 9926000019 METERING POINT INCLUDING FIXING OF METER No. 546
WITH METER EARTHING COMPLETE WORK AS
PER STANDARD SPECIFICATION BUT EXCLUDING
COST OF MATERIALS.
File No: DGVCLSDUR/MSC/e-file/4523/2026/1660/Billing
Approved By: Executive Engineer,Technical,DGVCLDOS
Letter No: DGVCLSDUR/0012/11/2026 Approved Date: 03-11-2026 18:10
ADDITIONAL COST FOR EXCAVATION OF PIT IN
HARD ROCK AREA FOR ERECTION OF POLE/ GUY
ETC. AS PER STANDARD SPECIFICATION OVER &
ABOVE NORMAL COST COVERED AGAINST
EXCAVATION OF PIT UNDER NORMAL SOIL FOR
ERECTION OF POLE,GUY, DOUBLE POLE
STRUCTURE EARTHING WITH THE APPROVAL OF
SUPDT.ENGINEER.
PROVIDING GUARDING TO HT LINE ON ROAD/
PROVIDING GUARDING OF LT LINES ON
ROAD/RAIL CROSSING.
23 9926000023 LT LINE TAPPING- SINGLE PHASE No. 51
24 9926000024 LT LINE TAPPING- THREE PHASE No. 93
LAYING OF OVER HEAD LT CABLE FOR ROAD
25 9926000025 CROSSING,HT LINE CROSSING AND TELEPHONE No. 263
LINE CROSSING ETC.(PER SPAN)
ERECTION OF SINGLE POLE STRUCTURES WITH
HG FUSES,TRANSFORMERS, LIGHTENING
ARRESTOR, DISTRIBUTION BOX. ON 8 METERS
200 KGAND PSC POLE INCLUDING EXCAVATION
OF PITS AND REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROM STORES TO SITE, FIXING
OF CHANNELS, SUPPORTING ANGLES,BRACINGS
CROSS ARMS CLAMPS, ANTICLIMBING DEVICES
DANGER BOARDS, CONDUCTOR AND CABLE
WIRING ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLE
AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OFGUY SETS AND EARTHING.
ERECTION OF SINGLE POLE STRUCTURES WITH
HG FUSES,TRANSFORMERS,
LIGHTENINGARRESTOR, DISTRIBUTION BOX. ON
9 to 11 METERS RSJ POLE INCLUDING
EXCAVATION OF PITS AND REFILLING OF EARTH,
CARTING OF TRANSFORMERS FROM STORES TO
SITE, FIXING OF CHANNELS, SUPPORTING
27 9926000027 ANGLES,BRACINGS CROSS ARMS CLAMPS, No. 5305
ANTICLIMBING DEVICES DANGER BOARDS,
CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLE AND
NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OFGUY SETS AND EARTHING.
ERECTION OF PSC POLES OF 10 *270 KG
INCLUDING EXCAVATION OF PIT AND REFILLING
OF EARTH, FIXING OF CROSS ARMS, TOP
FITTING CLAMPS ANTI-CLIMBING DEVICES,
28 9926000028 INSULATORS ETC. COMPLETE AND PAINTING OF No. 2666
FABRICATED MATERIALS USED ON THE POLES
AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
File No: DGVCLSDUR/MSC/e-file/4523/2026/1660/Billing
Approved By: Executive Engineer,Technical,DGVCLDOS
Letter No: DGVCLSDUR/0012/11/2026 Approved Date: 03-11-2026 18:10
ERECTION OF DOUBLE POLE STRUCTURE OF
METERS 270 KG PSC POLES INCLUDING
EXCAVATION OF PITS & REFILLING OF
EARTHING, FIXING OF CHANNELS, SUPPORTING
ANGLES,CLAMPS, ANTI-CLIMBING DEVICES
DANGER BOARDS,INSULATORS ETC.COMPLETE
AND PAINTING OF FABRICATED MATERIALS
USED ON THE POLES AND NUMBERING WITH
COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF
GUY SETS AND EARTHING.(WITHOUT AB
STRINGING OF 100MM2 ACSR/100MM2 AAAC
30 9926000030 CONDUCTOR FOR LT LINES INCLUDING FIXING 4861
OFINSULATORS, BINDING JUMPERING ETC.
STRINGING OF DOG CONDUCTOR FOR 11/22KV
31 9926000031 HT LINES INCLUDING FIXING OF INSULATORS, 4378
BINDING JUMPERING ETC.
ERECTION OF DOUBLE POLE STRUCTURES WITH
MOUNTING OF AB SWITCH, HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX. OF 10 METERS 270 KGAND
PSC POLES INCLUDING EXCAVATION OF PITS
AND REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROMSTORES TO SITE, FIXING
OF CHANNELS, SUPPORTING ANGLES,BRACINGS
CROSS ARMS CLAMPS, ANTI-CLIMBING
DEVICES,DANGER BOARDS, CONDUCTOR AND
CABLE WIRING ETC.COMPLETE AND PAINTING
OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINT
AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND
DISMENTALLING OF 8 MTR PSC POLE WITH
CREDITING OF FABRICATION AT STORE &
STACKING OF POLE SAFELY ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF 10 MTR PSC POLE WITH
CREDITING OF FABRICATION AT STORE &
STACKING OF POLE SAFELY ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8
MTR PSC POLE) (WITH TRANSFORMER) WITH
CREDITING OF FABRICATION & TRANSFORMER
AT STORE & STACKING OF POLE SAFELY ON
ROAD SIDE OR CREDITING TO DEPARTMENTAL
DISMENTALLING OF TRANSFORMER CENTRE (8
MTR PSC POLE) (WITHOUT TRANSFORMER) WITH
36 9926000036 CREDITING OF FABRICATION AT STORE & No. 2701
STACKING OF POLE SAFELY ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE
File No: DGVCLSDUR/MSC/e-file/4523/2026/1660/Billing
Approved By: Executive Engineer,Technical,DGVCLDOS
Letter No: DGVCLSDUR/0012/11/2026 Approved Date: 03-11-2026 18:10
STRINGING OF LT ABC OF 1*35 SQ MM + 1*25 SQ
MM INCLUDING FITTING OF ALL ACESSARIES I.E.
SPECIAL DESIGN SUSPENSION / TENSION
CLAMP, FIXING OF CROSS ARM, LT SHACKLE
37 9926000037 INSULATOR ETC. FOR FIXING OF MESSENGER KM 7046
WIRE AND TO PROVIDE SERVICE CONNECTION
ON AERIAL BUNCH CABLE BY INSULATED
PIERCEING CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE.
STRINGING OF LT ABC OF 3*50 SQ MM +1*25 SQ
MM+1*35 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION /
TENSION CLAMP, FIXING OF CROSS ARM, LT
SHACKLE INSULATOR ETC. FOR FIXING OF
MESSENGER WIRE AND TO PROVIDE SERVICE
CONNECTION ON AERIAL BUNCH CABLE BY
INSULATED PIERCEING CONNECTORS THROUGH
SERVICE CONNECTION BOX COMPLETE AS
REQUIRED & DIRECTED BY ENGINEER IN
STRINGING OF 11KV ABC OF 3*95 SQ MM +80 SQ
MM INCLUDING FITTING OF ALL ACESSARIES I.E.
SPECIAL DESIGN SUSPENSION / TENSION
39 9926000039 CLAMP, FIXING OF CROSS ARM, BINDING TO PIN KM 45107
INSULATOR,PREPARING SHACKLE
POINT,JUMPERS ETC. AS REQUIRED & DIRECTED
BY ENGINEER IN CHARGE
STRINGING OF 22 KV ABC OF 3*70 SQ MM +95 SQ
MM INCLUDING FITTING OF ALL ACESSARIES I.E.
SPECIAL DESIGN SUSPENSION / TENSION
40 9926000040 CLAMP, FIXING OF CROSS ARM, BINDING TO PIN KM 51287
INSULATOR,PREPARING SHACKLE
POINT,JUMPERS ETC. AS REQUIRED AND
DIRECTED BY ENGINEER IN CHARGE
STRINGING OF LT ABC OF 2*50 SQ MM +1*25 SQ
MM+ 35 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION /
TENSION CLAMP, FIXING OF CROSS ARM, LT
SHACKLE INSULATOR ETC. FOR FIXING OF
41 9926000041 MESSENGER WIRE AND TO PROVIDE SERVICE KM 9863
CONNECTION ON AERIAL BUNCH CABLE BY
INSULATED PIERCEING CONNECTORS THROUGH
SERVICE CONNECTION BOX COMPLETE AS
REQUIRED & DIRECTED BY ENGINEER IN
DISMENTALING OF RSJ (9/11 METER) POLE AND
CREDITING THE OLD MATERIAL TO STORE
DISMENTALING OF TRANSFORMER CENTER ON
10MTR,270KG PSC POLE(WITHOUT
TRANSFORMER) WITH CREDITING OF
FABRICATION AT STORE AND STACKING OF
POLE SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
DISMENTALING OF TRANSFORMER CENTER ON
10MTR,270KG PSC POLE(WITH TRANSFORMER)
44 9926000044 WITH CREDITING OF FABRICATION AT STORE No. 5332
AND STACKING OF POLE SAFELY ON ROAD SIDE
OR CREDITING TO DEPARTMENTAL STORE
File No: DGVCLSDUR/MSC/e-file/4523/2026/1660/Billing
Approved By: Executive Engineer,Technical,DGVCLDOS
Letter No: DGVCLSDUR/0012/11/2026 Approved Date: 03-11-2026 18:10
DISMENTLING OF 11KV ABC OF 3*95 SQ MM +80
SQ MM AND CREDITING FITTING OF ALL
ACESSARIES AND FABRICATION TO
DEPARTMENTAL STORE
DISMENTLING OF 22 KV ABC OF 3*70 SQ MM +95
SQ MM AND CREDITING FITTING OF ALL
ACESSARIES AND FABRICATION TO
DEPARTMENTAL STORE
DISMENTALING OF LT ABC OF 1*35 SQ MM + 1*25
SQ MM AND CREDITING FITTING OF ALL
ACESSARIES TO DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 3*50 SQ MM +1*25
SQ MM+1*35 SQ MM AND CREDITING FITTING OF
ALL ACESSARIES TO DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 2*50 SQ MM +1*25
SQ MM+ 35 SQ MM AND CREDITING FITTING OF
ALL ACESSARIES TO DEPARTMENTAL STORE.
RESTRINGING OF ALL TYPE OF CONDUCTOR
(EXCEPT DOG CONDUCTOR) FOR 11/22KV & LT ONE COND
LINES INCLUDING FIXING OF INSULATORS, PER KM
BINDING JUMPERING ETC.
RESTRINGING OF DOG CONDUCTOR FOR
51 9926000051 11/22KV HT LINES INCLUDING , BINDING 3129
LABOUR CHARGE FOR THE INSTALLATION OF
52 9926000052 NEW DTR METER. (METER WILL BE PROVIDED BY No. 355
LABOUR CHARGE FOR THE REPLACEMENT OF
DTR METER AND OLD METER SHOULD BE
CREDITED TO SDN STORE. (METER WILL BE
PROVIDED BY DGVCL)
LABOUR CHARGE FOR PROVIDING CT COIL FOR
54 9926000054 DTR METER CONNECTION. (CT COIL WILL BE PER CT 85
PROVIDED BY DGVCL)
LABOUR CHARGE FOR REPLACEMENT OF CT
COIL FOR DTR METER CONNECTION AND OLD CT
SHOULD BE CREDITED TO SDN STORE. (CT COIL
WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR FIXING OF MMB FOR DTR
METER (MMB WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR REPLACEMENT OF DTR
57 9926000057 METER BOX. (METER WILL BE PROVIDED BY No. 1820
PROVIDING / REPLACEMENT OF 1.5 SQ MM
58 9926000058 CORE COPPER CABLE 3.5 METER (CABLE TO BE No. 1840
PROVIDED BY AGENCY)
LABOUR CHARGE FOR
PROVIDING/RECONNECTION OF TERMINAL PER
CONNECTION WITH PROPER SIZE OF LUGS. TERMINATION
(LUGS COST IS BORNE BY AGENCY)
File No: DGVCLSDUR/MSC/e-file/4523/2026/1660/Billing
Approved By: Executive Engineer,Technical,DGVCLDOS
Letter No: DGVCLSDUR/0012/11/2026 Approved Date: 03-11-2026 18:10
LABOUR CHARGE FOR THE SPOT READING OF
DTR METER WITH DETAIL SURVEY OF DEFECT IF
ANY. A DULY SIGN COPY BY SURVEYOR PERSON
OF AGENCY IN PRO-FORMA REPORT SHOULD BE
60 9926000060 SUBMITTED TO SDN OFFICE.(* ONLY IF ALL PER DTR 60
PARAMETER OF VOLTAGE, CURRENT & LOAD AS
SHOWN IN PER-FORMA IS FILLED) AS PER THE
INSTRUCTION OF ENGINEER IN-CHARGE.
LABOUR CHARGE FOR THE SPOT READING OF
DTR METER WITH DETAIL SURVEY OF DEFECT IF
ANY. A DULY SIGN COPY BY SURVEYOR PERSON
61 9926000061 OF AGENCY IN PRO-FORMA REPORT SHOULD BE PER DTR 30
SUBMITTED TO SDN OFFICE. (DULY FILL PER-
FORMA IN FAULT CONDITION IN WHICH READING
PARAMETER IS NOT SHOWN IN METER)
INSTALLATION OF DTR METER INCLUDING
METER BOX, PROVIDING & FIXING OF 1.5SQ MM
SINGLE STRAND 10 CORE ARMOURED COPPER
CABLE (3.5METER), TERMINATION IN METER &
COIL ETC.(METER, METER BOX, C.T./P.T. COIL
WILL BE PROVIDED BY DGVCL)
INSTALLATION OF DTR METER INCLUDING
METER BOX, TERMINATION IN METER & COIL
63 9926000063 ETC. (WITHOUT 10CORE COPPER CABLE) No. 886
(METER, METER BOX, C.T./P.T. COIL WILL BE
PROVIDED BY DGVCL)
Binding of messanger Conductorat with a distance not
more than 0.75 mtr with 6 turns minimum on XLPE
Cable with single strand binding wire (including cost of
Supply and Installation of 11/22 kV Distribution
Transformers HT Terminal protector (UV Resistance)
with using 95/120/150 sq.mm long barrel aluminum
lug. (1Set = 3 Nos i.e. on R, Y, B)
Supply & Installation of HT EPR Tap on 11/22 kV
Distribution Transformer with replacement of bare
conductor by HT ABC conductor (DO bottom side to
transformer) after removal of semi conductor by HT
ABC (6 inch both side). HT ABC to be supplied by
DGVCL. (1Set = 3 Nos i.e. on R, Y, B)
Supply, Installation, Testing and Commissioning of
Maintenance Free, Ready Capsule, Pipe-In-Cage (Pic)
Type, Earth Electrodes for HT Feeder Pole Having
2000 mm Electrode Length as per the Tender
Specifications and Drawing. (All Materials Will Be
Supplied By Agency)
Supply, Installation, Testing and Commissioning of
Maintenance Free, Ready Capsule, Pipe-In-Cage (Pic)
Type, Earth Electrodes for HT Feeder Pole Having
3000 mm Electrode Length as per the Tender
Specifications And Drawing. (All Materials Will Be
Supplied By Agency)
File No: DGVCLSDUR/MSC/e-file/4523/2026/1660/Billing
Approved By: Executive Engineer,Technical,DGVCLDOS
Letter No: DGVCLSDUR/0012/11/2026 Approved Date: 03-11-2026 18:10
Supply and Installation of 25 X 3 mm GI Strip having
hot dip- galvanized-zinc coating of 80-100 microns
without any joints or welding. Both the end of the GI
strip should be connected with GI nut bolts and
required fabrication work for giving separate earthing
connections to(1) Neutral of the transformer(2) MS
structures of the transformer center (Approximately
meter GI strip per transformer centre- as per
requirement and instruction of Engineer in- charge) (All
Materials will be supplied by Agency)
Supply and Installation of uPVC standard make Pipe
of 1.25" diameter for covering GI strip with UV
protected Cable Ties of 550 X 7.6 mm size to bind with
pole face(Approximately 25 meter uPVC pipe for GI
strip covering per transformer centre -as per
requirement and instruction of Engineer in-charge.
Supply & fixing of upto 33 kV Conductor sleeve for
Busbar to Drop out Fuse and Drop
71 9926000093 out fuse to Transformer H.T. including Busbar (12 mm Per TC
sleeve) as per technical
specification. (All Materials will be supplied by Agency)
Supply & fixing of upto 33 kV Conductor sleeve for
Busbar to Drop out Fuse and Drop
72 9926000100 out fuse to Transformer H.T. without Busbar (12 mm Per TC
sleeve) as per technical
specification. (All Materials will be supplied by Agency)
Supply & fixing of upto 33 kV Conductor sleeve for
Busbar to Drop out Fuse and Drop
73 9926000094 out fuse to Transformer H.T. including Busbar(15 mm Per TC
sleeve) as per technical
specification. (All Materials will be supplied by Agency)
Supply & fixing of upto 33 kV Conductor sleeve for
Busbar to Drop out Fuse and Drop
74 9926000101 out fuse to Transformer H.T. without Busbar(15 mm Per TC
sleeve) as per technical
specification. (All Materials will be supplied by Agency)
Supply & fixing of Disc type Red Color FRP(Non-
flammable) material with Weather
resistant, Non-conductive bird guard OD=300 MM,
ID=33 MM, Width =1.25 MM, one
side cut from ID to OD. (All Materials will be supplied
Providing and fixing of LT Terminal protectors i.e. Re-
useable boot (LT Side 1.1 kV) including LT (1.1 kV)
insulating taps. All live part at LT side shall be covered
with fixing of LT insulating taps.
77 Nylon Net around Transformer Center
77.1 9926000097 Nylon Net (12 * 15 ft) Per Net
77.2 9926000098 Nylon Dori Per TC
Labour charge for fitting Nylon Net (All fabricated
77.3 9926000099 material for fitting nylon net shall be provided by Per TC
TOTAL ESTIMATED AMOUNT OF SCHEDULE B1
1 9924000001 Cutting of Tree branches surounding HT/LT line Per Tree 57
Replacement of old jumpers & providing new double
jumpers with 8" binding & capsuling with PVC pipe etc
File No: DGVCLSDUR/MSC/e-file/4523/2026/1660/Billing
Approved By: Executive Engineer,Technical,DGVCLDOS
Letter No: DGVCLSDUR/0012/11/2026 Approved Date: 03-11-2026 18:10
3 9924000005 Support pole for Stay PSC/STP/RSJ No. 633
4 9924000006 Pin binding of conductor 11/22kv Pin insulator No. 18
Pin binding of conductor 11/22kv Pin insulator per pole
5 9924000007 in costle area with cleaning . No. 41
6 9924000008 Pin binding of conductor LT shakel insulator No. 14
7 9924000009 Replacement of one/both disc.insulator at strain pole No. 161
8 9924000010 Replacement of LT shackle insulator at cut point No. 31
9 9924000011 Refixing of V cross Arm No. 61
10 9924000012 Replacement of V cross Arm No. 210
11 9924000013 Refixing of Top fitting in proper position No. 41
12 9924000014 Replacement of Top fitting No. 51
13 9924000015 Replacement of LT cross Arm No. 105
Providing DO fuse on DP with carting &
jumpuring(ONE DO FUSE)
Numburing of pole with paint by preparing back ground
15 9924000017 of one colour and have lettering(height 3" * width 0.5") No. 46
16 9924000018 Fixing of MMB(1PH.) at consumer end No. 86
17 9924000019 Fixing of MMB(3PH.) at consumer end No. 128
18 9924000020 Replacement of (1ph.) meter for Urban area No. 51
19 9924000021 Replacement of (1ph.) meter for Rural area No. 74
painting consumer no. on MMB (Urban) (with letter
size height 40mm* width 8mm)
painting consumer no. on MMB (Rural) (with letter size
height 40mm* width 8mm)
22 9924000024 Replacement of deteriorated Single phase Service line No. 93
Fixing of new dist. Box with complete wiring including
clamps,nut bolts etc.
Reparing of guarding involving reshaping of bearer
wire cross lacing binding etc.
Painting of steel fabricated material of RSJ DO DP
structure with paint
Painting of steel fabricated material of RSJ pole
mounted transformer double pole structure with paint
Painting of steel fabricated material of RSJ single pole
painting of steel fabricated material of PSC Single pole
(HT line) with paint
painting of steel fabricated material of PSC DO DP
double pole with paint
painting of steel fabricated material of PSC double
pole at pole mounted transformer with paint
31 9924000033 Providing line seperater single phase No. 11
32 9924000034 Providing line seperater three phase No. 31
Replacement / Providing of stay insulator along with
adjustment of tension in stay wire
Replacement of deteriorated /providing LT dist. Box
with new up to 100KVA capacity & crediting it to store.
Replacement of deteriorated /providing LT dist. Box
35 9924000037 with new above 100KVA capacity & crediting it to No. 2084
36 9924000038 Adjustment of tension in stay wire No. 158
File No: DGVCLSDUR/MSC/e-file/4523/2026/1660/Billing
Approved By: Executive Engineer,Technical,DGVCLDOS
Letter No: DGVCLSDUR/0012/11/2026 Approved Date: 03-11-2026 18:10
37 9924000039 Refitting of LA No. 31
Converting pin point to Shackle point including
dismentaling & restringing etc.
replacement of 11KV Pin insulator with providing new
double pin binding
replacement of 22KV Pin insulator by new 11kv pin
40 9924000042 insulator with spares & providing new double pin No. 81
Providing 11kv double disc insulators with binding &
Replacement of existing 11kv conductor (all size) with
new double pin binding
43 9924000046 Plumbing of PSC Pole with straightening at pin point No. 287
Plumbing of PSC Pole with straightening at tension
Plumbing of tilted DP structure (PSC/RSJ/STP) with
refilling of stone Murrum etc.
Providing new 11kv AB /GO switch with fabrication
and insulated colour code jumper, binding, lugs etc
Replacement of old 11kv AB /GO switch with providing
new insulated jumper, binding, lugs etc
Providing cage type loop guard in verticle LT line with
using PVC reel insulators etc
Labour charges for replacement /providing of MMB &
service with all accessories for three phase connection
Labour charges for replacement /providing of MMB &
50 9924000054 service with all accessories for single phase No. 554
Dismentalling of existing Dist.X'mer center(RSJ /STP
51 9924000055 POLE) 25/63/100/200 KVA with all fabrication & No. 5528
creditig the old material to store
52 9924000056 Disconnection from LT pole 1 phase No. 46
Reconnection from LT pole 1 phase
( payment after receipt of R/C charges)
54 9924000058 Disconnection from LT pole 3 phase No. 66
Reconnection from LT pole 3 phase
( payment after receipt of R/C charges)
Dismentaling & removing of service line from pole &
crediting to S/dn (1 ph.)
Dismentaling & removing of service line from pole &
crediting to S/dn (3 ph.)
Reconnection of service line complete with PVC cable
Reconnection of service line complete with PVC cable
Providing spiral type earthing by G.I. NO 8(weight 2kg
-5mtr in length) with salt and coal 10kg each, including
60 9924000064 pvc rigid pipe 20mm dia( 1.5mtr length) to pass No. 816
exposed part of G.I. wire at consumer end with all
materials, earth resistance should be less than 2 ohms
File No: DGVCLSDUR/MSC/e-file/4523/2026/1660/Billing
Approved By: Executive Engineer,Technical,DGVCLDOS
Letter No: DGVCLSDUR/0012/11/2026 Approved Date: 03-11-2026 18:10
Providing and fixing of signle core 1.5 sq mm single
strand copper insulated cable with cable nail clip for
spiral type earthing at consumer end. The end of G.I.
no 8 is to be connected by connector with copper
61 9924000070 cable of which other end shall be connected to the per meter 30
earth terminal of meter box. This item shall be used in
location where there is more distance between earth
terminal and earthing terminal of meter. (All materials
supplied by contractor)
Stringing of LT ABC of 1*35 SQ MM + 1*25 SQ MM
including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, LT
shackle insulator etc. for fixing of messenger wire and
inclusive of dismantling charge of existing bare
conductor and crediting in to store & dismentaling of
service line from LT bare conductor and to provide
service connection on Aerial Bunch Cable by insulated
pierceing connectors through service connection box
complete as required & directed by Engineer in
Stringing of LT ABC of 3*50 SQ MM +1*25 SQ
MM+1*35 SQ MM including fitting of all acessaries i.e.
special design suspension / tension clamp, fixing of
cross arm, LT shackle insulator etc. for fixing of
messenger wire and inclusive of dismantling charge of
existing bare conductor and crediting in to store &
dismentaling of service line from LT bare conductor
and to provide service connection on Aerial Bunch
Cable by insulated pierceing connectors through
service connection box complete as required &
directed by Engineer in Charge.
Stringing of 11KV ABC of 3*95 SQ MM +80 SQ MM
including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm,
binding to pin insulator,preparing shackle
point,jumpers etc. and inclusive of dismantling charge
of existing bare conductor and crediting in to store
complete as required & directed by Engineer in
Stringing of 22 KV ABC OF 3*70 SQ MM +95 SQ MM
including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm,
binding to pin insulator,preparing shackle
point,jumpers etc. and inclusive of dismantling charge
of existing bare conductor and crediting in to store
complete as required & directed by Engineer in
Stringing of LT ABC of 2*50 SQ MM +1*25 SQ MM+
35 SQ MM including fitting of all acessaries i.e. special
design suspension / tension clamp, fixing of cross arm,
LT shackle insulator etc. for fixing of messenger wire
and inclusive of dismantling charge of existing bare
66 9924000069 conductor and crediting in to store & dismentaling of KM 15613
service line from LT bare conductor and to provide
service connection on Aerial Bunch Cable by insulated
pierceing connectors through service connection box
complete as required & directed by Engineer in
TOTAL ESTIMATED AMOUNT OF SCHEDULE B2 500000
File No: DGVCLSDUR/MSC/e-file/4523/2026/1660/Billing
Approved By: Executive Engineer,Technical,DGVCLDOS
Letter No: DGVCLSDUR/0012/11/2026 Approved Date: 03-11-2026 18:10
Labour charge for erecting of 11kV / 22 kV XLPE cable
of size up to 240 mm2 on DP Structure with fixing of
14 9925000014 02 Nos polymer cleats on top and middle part.Polymer per Job 591
cleats, nut bolts etc. fixing material to be provided by
Providing & fixing of 6.11kg/cm2 , class-4,Green color,
110mm O.D. , 8.5mm thickness H.D.P.E. pipe
confirms to IS 4984 and BIS certification on the
erected DP structure for the mechanical protection of
cable by inserting the cable inside HDPE pipe. The
HDPE pipe shall be erected in such a way that 300mm
shall be below the ground level and the rest 2700 mm
shall be supported on the DP Structure with 01 No
Polymer cleat.All materials including polymer cleat and
Nut bolt to be provided by contractor.
Providing and fixing of pipe type earthing from 80 mm
dia class-B GI pipe with pit to be filled with salt & coke
and construction of chamber as per DGVCL Drg. No.
16 9925000016 dg /100 for DP and cable. The earthing pit should be No. 3635
joined with cable by G.I. strip of size 1” width & 2 mm
thick. All material GI pipe, Coke, Salt etc will be
supplied by bidder.
Supply & fixing of heat shrink type end
17 9925000017 terminations (outdoor) for upto 11kV 3C x 185 mm2 No. 3635
size XLPE cable as per DGVCL technical
Supply & fixing of heat & shrinkable end terminations
18 9925000018 (outdoor) for upto 22 kV 3C x 185 mm2 size XLPE No. 6231
cable as per DGVCL technical specification)
Supply & fixing of heat shrink type end terminations
19 9925000019 (indoor) for upto 11kV 3C x 185 mm2 size XLPE cable No. 3635
as per DGVCL technical specification)
Supply & fixing of heat & shrinkable end terminations
20 9925000020 (indoor) for upto 22 kV 3C x 185 mm2 size XLPE cable No. 6231
as per DGVCL technical specification
Providing and fixing of insulating bus bar, made from
11KV/22KV XLPE cable after removal of semi
conducting layer and applying of PVC heat shrinkable
anti-tracking core insulating tubing (1.1KV), on both
end terminal using Aluminium long barrel heavy duty
up to 240 sq mm lugs, Aluminium bus connector.
Taping with PG- clamp for bus conductor as per
drawing and as per instruction of EIC. The Alluminium
lugs and PG clamp shall be covered with 11KV/22KV
HT insulating tapes.(11KV/22KV XLPE cable will be in
scope of DGVCL while all other materials will be in
bidder's scope)
Testing of cable at various points and
commissioning the feeder as per instruction of
engineer-in-charge.Test result shall be submitted
by contractor with bill.
Preparation and submission of 6 (six) copies, of
complete layout drawings with GIS mapping as per
actual cable routing showing road crossing, HDPE
pipe sleeving, jointing locations, markers etc.
File No: DGVCLSDUR/MSC/e-file/4523/2026/1660/Billing
Approved By: Executive Engineer,Technical,DGVCLDOS
Letter No: DGVCLSDUR/0012/11/2026 Approved Date: 03-11-2026 18:10
Providing & fixing of aluminium tag of size 250 mm (L)
x 75 mm (W) from 3 mm aluminium sheet along with
1.0 mm dia aluminium binding wire for fixing of
aluminium tag near end termination joint at DP
structure for identifyng the cable. The details of feeder
i.e. 11 / 22 KV with feeder name shound be punched
on the tag by letter punch of size 16 mm as per
instruction of In-charge Engineer.
Supply & fixing of heat shrink type end terminations
30 9925000030 (outdoor) for 11kV 3C x 240 mm2 size XLPE cable as No. 4427
per DGVCL technical specification
Supply & fixing of heat & shrinkable end terminations
31 9925000031 (outdoor) for 22 kV 3C x 240 mm2 size XLPE cable as No. 6231
per DGVCL technical specification)
Supply & fixing of heat shrink type end terminations
32 9925000032 (indoor) for 11kV 3C x 240 mm2 size XLPE cable as No. 4338
per DGVCL technical specification)
Supply & fixing of heat & shrinkable end terminations
33 9925000033 (indoor) for 22 kV 3C x 240 mm2 size XLPE cable as No. 6231
per DGVCL technical specification
Laying of any size of 11/ 22 KV XLPE /PILC Cable in per cable per
redaymade trench or in open space mtr
Labour charges for Lying of O/H XLPE cable pole to
TOTAL ESTIMATED AMOUNT OF SCHEDULE B3
Total of Schedule B1 + B2 + B3 is Rs.
1.AS 300 Mm2 Cable Cost Data not Availble with
DGVCL and We have Proposed 300 mm2 Cable at
Various Location to Create Robust netwrok with
RMU and SS End Hence Cost Data of UGVCL
Considered as Ref and Rate Taken Accordingly as
per Telephonic Instruction GIven by Competent
Authority from Circle Office
File No: DGVCLSDUR/MSC/e-file/4523/2026/1660/Billing
Approved By: Executive Engineer,Technical,DGVCLDOS
Letter No: DGVCLSDUR/0012/11/2026 Approved Date: 03-11-2026 18:10
1.DGVCL will provide key material like M.S.
materials,ABC/Bare conductors,PSC/RSJ
Poles,Insulators,Fabricated materials etc. to the
2.All fabricated items shall be fabricated as per
DGVCL approved drawing and by welding rods
confirming to the relevent ISI specification and as
directed by Engineer in charge.
3.Necessary electricity connection for fabrication items
shall be provided by DGVCL on payment of required
charge for connection & electricity bill of the same
shall be paid by the agency.
4.All the rates are inclusive of PF & Exclusive of GST
applicable time to time.
5.All steel material are to be painted as below:
(a) Scrubbing of rusted surface properly before
applying the paints on to the RSJ poles & steel
fabricated materials of RSJ/PSC poles is must
(b) Two coats of approved ISI mark red oxide (primer)
is to be properly painted for the RSJ poles & steel
fabricated materials of RSJ/PSC poles.
(c) Two coats of approved ISI mark silver paint (i.e.
triple mangoes or equivalent quality silver paint) is to
be properly painted on to the RSJ poles & steel
fabricated materials of RSJ/PSC poles.
1. Excavation, Drilling and Cable laying should be
done with all road safety measures such as hard
barricading, displaying “DANGER” sign and “DGVCL -
Work in Progress” on it with light reflective strips or
paint. Proof of all barricading and safety equipment Deputy Engineer (Tech)
need to submit. DGVCL
2. Cable laying should be done through roller (not Sachin Division
through tractor or pulling by any other vehicles).
3. Ownership document regarding roller/pulling
machine and HDD machine need to submit or
agreement with agency of above narrated machine
regarding work for this tender required to submit.
4. Trail pit excavation and De-excavation should be
done simultaneously so that any chance of road
accident can be prevented.
5. Three no of Polymer cleat should be provided on
rising cable for proper fitting and if it is not feasible to
provide third polymer cleat at the bottom than two nos
of polymer cleat on upper side and strap strip on
bottom end required to install for proper fitting of rising
Technical 6. 100% videography of cable laying along with
Terms landmark location of cable laying required to be done
and submit Pen drive to the concern engineer for their
7. Aluminum strip required to use to connect end of
cable at cable rising location as per instruction of
Engineer in charge. Also no joints will be allowed in GI
strip for cable Earthing and strip will be connected
through GI bolts only.
8. Issues regarding ROW on field should be
resolved by contractor itself.
File No: DGVCLSDUR/MSC/e-file/4523/2026/1660/Billing
Approved By: Executive Engineer,Technical,DGVCLDOS
Letter No: DGVCLSDUR/0012/11/2026 Approved Date: 03-11-2026 18:10
9. Testing & measuring equipment: - 5 KV Digital
insulation testers, Digital Earth clamp meter for
measurement of Earthing and leakage current, Digital
Rodometer with NABL accredited agency valid test
10.Earthing value & Insulation Resistance (IR) value of
all location along with Geo tagged (longitude &
latitude) wise testing and measured value photograph
need to submit with Bill.
11.Depth chart should be provided at every 100 meter
with mentioning landmark.
12. Partial Discharge test to be carried out on sample
part of cable before charging as decided by in charge
13. Qualified cable jointer with Minimum five years of
experience required with necessary certification
regarding qualification and specific experience.
14. Performance Bank Guaranty required to submit
5% of tender value for two years against cable joint
failure. Moreover, cable joint failure or end termination
failure will have to repair within 24 Hrs for 2 years of
guaranty period.
15. Fixing of mechanical protection HDPE pipe at
rising should be properly buried as per specification.
16. Fixing of Route marker strictly as per specification.
17. Minimum annual Turnover should be at least
tender estimated value and in addition to CVC
guideline narrated in tender for UG cable laying work.
18. Marking of feeder name, direction and location on
cable is compulsory during final scrutiny to declare
work completion.
19. End termination and straight joint kit should be of
premium quality as specified in Annexure-2. Technical
specifications for the same to be submitted along with
20. Cable straight joint should be done with mid span
joint instead of long barrel Lug.
21. Agreement with vendor of cable joint kit and End
termination kit to supply for this tender for concern
bidder should be submit at the time of bidding.
File No: DGVCLSDUR/MSC/e-file/4523/2026/1660/Billing
Approved By: Executive Engineer,Technical,DGVCLDOS
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
NOTICE INVITING TENDER.pdf
5. Reference Bid Drawing ok.pdf
6. Annexure- 2 and 3.pdf
Schedule B.pdf
Technical Specifications.pdf
Tender 718.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .