Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC THAZHATHUPERI HOUSE BATHUM P O WANDOOR MALAPPURAM 679339 | WANDOOR | MALAPPURAM | KERALA | 679339 | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical OPP JNANAM VEEDU ELLEYAM V B WANDOOR 679327 | WANDOOR | MALAPPURAM | KERALA | 679327 | - | Rejected-Technical L2 |
Tender Value
₹8.7 L
EMD Value
₹21,640
Closing Date
8 Feb 2022, 5:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Engineer
LSGD Section Office, Porur GP
XIII-th Plan 2021-22 of Porur GP, 130, Pallikunnu drinking water projct- related facilities- ward 10
2022_LSGD_471487_1
AE/LSGD/ETN-02/2021-22
Open Tender
Civil Works - Water Works
Item Rate
90 days
Porur GP
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,043
Yes
₹21,640
Yes
2 Sept 2022
1 Feb 2022
11 Feb 2022
1 Feb 2022
8 Feb 2022
1 Feb 2022
45 days
Amount
Pumbing Main
od1290327/2021_2022 : Providing and fixing PVC pipes including of pipes with one step PVC solvent cement,<br>trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 10Kgf/cm2
od1290414/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at<br>1.00 m spacing. This includes jointing of pipes & fittings with one step PVC<br>solvent cement and testing of joints complete as per direction of Engineer-in Charge 63 mm dia 10 Kfg/cm - Internal work- Exposed on wall
Completion of RCC Tank Structure
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
App:C-Distribution line
50.18.9.6.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 10Kgf/cm2
50.18.9.5.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge 40 mm dia 10Kgf/cm2
50.18.9.3.2 : Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2
18.12.2 : Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work20 mm dia nominal bore
od1472478/2021_2022 : Supplying & Fixing PVC stand post in 75mm PVC pipe 0.85m height filled with CC1:2:4
od1472479/2021_2022 : od1383074/2021_2022 :Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including<br>jointing with PVC solvent cement -20 mm water tap best quality.
Booth PumpHouse
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
4.3.1 : Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
50.10.2 : Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od1472573/2021_2022 : Roofing with GI hard colour powder coated trafford sheet 0.35mm thick or nearest available thickness with overlaps of 150mm at ends and GI hooks or crank CI bolts and nuts including plain washers and bitumen washers etc complete.<br>
od1635405/2021_2022 : Supply and erection of electrically d riven best quality reputed make open well type sebmercible pumpset capable of discharging the design discharge against the designed total head .The pump should be with broonze impeller ,stainless shaft and all accessories such as main switcher,starter,voltmeter,suitable size shee metal panel board etc complete vide order no KWA/HO/SP333/2011/pumps dtd 20/12/11 for RS 18135
MOHAMMED ALI V.P.
Bidder Name
T P Abdul Nazar
MOHAMMED ALI V.P.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_676039.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .