| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹26.7 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹36.9 L+₹10.2 L (38.2%)Rejected-Finance | 2 | Rejected-Finance L2 | |
| 3 | 3₹37.9 L+₹11.2 L (41.9%)Rejected-Finance | 3 | Rejected-Finance L3 |
Tender Value
₹33.8 L
EMD Value
₹50,000
Closing Date
15 Feb 2023, 3:00 pmClosed
Executive Engineer
P.H Division Kkochi-16
Replacing old and damaged 100mm AC pipe by 160mm PVC (6Kg/cm2) at Nethaji road and 63mm PVC pipe (6Kg/cm2) at bylane of Nethaji road Koduparambu middle lane,Cherukkad north lane, bylane near to Surabhi lane in division no32(old) 40 new
2023_KWA_556669_1
WRD/KWA-CE(CR)/TR/8068/2022_26
Open Tender
Civil Works - Water Works
Item Rate
180 days
Kochi Corporation
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,760
₹50,000
19 Apr 2023
9 Feb 2023
16 Feb 2023
9 Feb 2023
15 Feb 2023
9 Feb 2023
Amount
Working Charge
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
16.83:Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.98.1008:Engaging Coolie.
100.98.1009:Engaging Fitter ( grade 1).
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
2.16.1:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth not exceeding 1.5m
100.98.216:Supply of PVC Pipe, 6kg/cm2, 160mm Dia.
100.98.211:Supply of PVC Pipe, 6kg/cm2, 63mm Dia.
100.9.11:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 160 mm nominal outside diameter pipes.
100.9.6:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes.
OD87134/2022-2023:Interconnecting the existing 225mm CI pipe line to newly laid 160mm PVC pipe by using 225 x 100mm MS Saddle clamp, 110mm PVC MTA, 110mm PVC bit, 110mm PVC Elbow, 110 x 160mm PVC Enlarger,etc, Including cost of materials and labour charges and hire for tools etc complete
OD87248/2022-2023:Interconnection work between newly laid 160mm PVC to existing 110/90/ 63mm PVC pipe line by using 160x50mm MS Saddle clamp,63mm PVC MTA,63mm PVC Elbow, etc complete. Including cost of labour and materials etc complete.
OD87068/2022-2023:Interconnecting the existing 250mm CI pipe line to newly laid 63mm PVC pipe by using 200 x 50 mm MS Saddle clamp, 63mm PVC MTA, 63mm PVC bit, 63mm PVC Elbow, etc, Including cost of materials and labour charges and hire fortools etc complete
OD87269/2022-2023:Shifting the public hydrants/ house connections with 20mm ASTM pipe and specials from the existing line to the newly laid pipes at different places
15.60:Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
16.79:Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
16.84:Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.)
100.98.460:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 150mm.
100.31.1.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class I.
18.34.1:Constructing masonry chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
BIJU T R
GIRISHKUMAR CK
Bidder Name
K M MADHU
BIJU T R
GIRISHKUMAR CK
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_818531.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .