Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC | L1 | Accepted-AOC L1 AND REASONABLE | |
| 2 | L2₹20.8 L+₹1.3 L (6.66%)Rejected-Finance | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹21.3 L+₹1.8 L (9.19%)Rejected-Finance | L3 | Rejected-Finance NOT L1 |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
28 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE A JAMNAGAR
INFANTRY LINES JAMNAGAR
CERTAIN REPAIRS TO BROKEN CHAJJAS, BALCONY, ROOF PROTECTION PVC TANK OF OTM ACCN ETC AT INFANTRY LINES JAMNAGAR
2023_MES_604305_2
8998
Open Tender
Civil Works
Item Wise
274 days
JAMNAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE A JAMNAGAR
₹38,000
21 Sept 2023
31 Jul 2023
30 Aug 2023
1 Aug 2023
28 Aug 2023
14 Aug 2023
Amount
Demolition of RCC as in lintels, chajja,manole cover landing,stair case,tank staging of cement concrete reinforced of similar suspended works and rubbish off the premises. complete all as specified and directed by Engr-in-charge.
M & L RCC nominal mix 1:1.5:3 type A1 using 20mm graded aggregate as in chajja, lintel, landings, staircase, parapet & tank staging etc and incl necessary form work complete all as specified and directed by Engr-in-charge.
S & F TMT steel bars, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with & including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-charge.
S & F TMTsteel bar, 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with & including MS wire (annealed) not less than 0.9mm dia or securing with clips. Gde Fe500 or FE 500d
Demolition of brick work or stone/ boulders masonry, built in cement mortar, including all quoins, arches, pillars etc., but excluding ashlars facing, dressed stone work and precast concrete articles complete all as specified and directed by Engr-in-charge.
M & L for fly ash brick old size, straight or curved on plan exc. 6 m mean radius built in cement mortar (1:6) complete all as specified and directed by Engr-in-charge.
M&L for fly ash brick old size, Half brick thick, old size built in cement mortar 1:4 straight or curved on plan, complete all as specified and directed by Engr-in-charge.
Taking down cement plaster of any description on brick or stone walls incl raking out joints hacking for key, scrubing down with water etc. complete all as specified and directed by Engr-in-charge.
M&L 15mm thick rendering in two layers of 10mm in CM 1:6 and top layer of 5mm thick in CM 1:4 on external stone/concrete wall surfaces with WPC compound 3% by weight of cementincluding finished even and smooth w/o using extra cement all as specified and directed (Note (A) interial WPC compound shall be used in second layer (b) intergial WPC shall be paid seperately on supply only.)
Supply only Integral waterproofing compound
M & L Preparation of newly plastered surfaces of wall incl sweeping clean with brush to remove loose dust, sand, etc and applying two coats of heavy duty waterproofing coat (Dr Fixit Wounderproof-1 or equivalent) by mixing water @ 25-30% to make slurry coating and allow 4 to 6 hrs time for drying up of first coat before application of second coat in perpendicular direction of first coat and further left to dry for 4 hrs complete all as specified and directed as per manufacturer instructions.
M&L Preparation of newly plastered surface and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engr-in-charge.
Material and labour for complete removal of existing treatment from plastered or unplastered surfaces of walls including cleaning with scrapers, any number of coats and any width or girth etc, the area of application should be cleaned thoroughly, remove all dirt, dust and uneven elements from the surface by washing and scraping and all the unevenness in the surface should be corrected by filling the exterior wallcare putty, surface should be sanded down with fine grade sand paper for smoothness applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces,as per manufacturers instructions complete all as specified and directed by Engr-in-charge.
Removal of all loose/unsound/bad/damaged concrete or plaster existing RCC structure of slab/beams/walls by using chesel/hammar .Cut and remove unsound reinforcement bars, wires etc without damaging the sound reinforcement . clean loose rust from bars manually with brush . fixing new supplymentary bars if required,either by tying it with existing bars or by welding on it. Applying eppoxy bonding agent and making good with polymer modified plaster/micro concrete as required thickness over a coat of rust removing alkaline primer and match the finishing to the existing surface in ground floor including formwork complete all as specified and directed.
Preparing of spalled RCC surfaces due to seepage (nexc 50mm deep) by exposing fully corroded steel in the repair area and remove all scales and corrosion deposits mechanically or ideally by grit blasting, clean the surfaces and remove loose concrete, any dust, oil paint, grease etc and pre-wet the surface with water and allow to dry slightly, apply approved zinc primer over the cleaned re-bars & allow to dry before repair and the substrate should be primed by applying one neat/clear coat of approved Epoxy bonding agent, finally apply Polymer Mortar of approved Make prepared as per manufacturer instructions (laid in 10 to 15mm thickness with bonding agent accompanied after each 15mm layer) to the prepared substrate by hand when primer becomes tacky ensuring that the material reached evenly behind bars incl curing the surfaces complete all as specified and directed by Engr-in-charge.
(a) For area less than 1 sqm
(b) For area more than 1 sqm and up to 2 sqm
(c) For area more than 2 sqm and up to 3 sqm
Taking down 20mm dia steel tubing and connection including cleaning for refixing or removal to store complete all as specified and directed by Engr-in-charge.
S&F GI tubing 20 mm bore medium grade with all fittings, fixed to wall, ceiling or laid in floors complete all as specified and directed by Engr-in-charge.
Refixing 20mm tube medium grade galvanized with all fittings & fixed (including new fitting if required for refixing in position) complete to walls & ceiling or laid in floors complete all as specified and directed by Engr-in-charge.
Taking down 25mm dia steel tubing and connection including cleaning for refixing or removal to store complete all as specified and directed by Engr-in-charge.
S&F GI tubing 25mm bore medium grade with all fittings, fixed to wall, ceiling or laid in floors complete all as specified and directed by Engr-in-charge.
Refixing 25mm tube medium grade galvanized with all fittings & fixed (including new fitting if required for refixing in position) complete to walls & ceiling or laid in floors complete all as specified and directed by Engr-in-charge.
S&F 500ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position, incl taking down old tank complete all as specified and directed by Engr-in-charge.
Taking down 500ltr capacity rotational moulded polyethylene water storage tanks and Refixing after repair to roof incl connecting valve and pipe complete all as specified and directed by Engr-in-charge.
S&F 1000ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position, incl taking down old tank complete all as specified and directed by Engr-in-charge.
Taking down 1000ltr capacity rotational moulded polyethylene water storage tanks and Refixing after repair to roof incl connecting valve and pipe complete all as specified and directed by Engr-in-charge.
S & Fixed in repairs PVC (SWR) pipes 110mm bore confirming to IS-13592-1992 type 'B' single socketed, in any length with rubber ring joints fixed to walls with PVC clamp complete all as specified and directed by Engr-in-charge.
S & Fixed in repairs PVC (SWR) pipes 75mm bore confirming to IS-13592-1992 type 'B' single socketed, in any length with rubber ring joints fixed to walls with PVC clamp complete all as specified and directed by Engr-in-charge.
S&F in repairs PVC (SWR) bend any radius, 110mm dia with access door complete all as specified and directed by Engr-in-charge.
S&F in repairs PVC (SWR) bend any radius, 75mm dia with access door complete all as specified and directed by Engr-in-charge.
S&F in repairs, PVC (SWR) branch pipe, 110mm dia single (single ‘Y’) equal or un equal with access door complete all as specified and directed by Engr-in-charge.
S&F in repairs 110 mm dia PVC (SWR) junction single (T-Junction) equal or un equal with access door complete all as specified and directed by Engr-in-charge.
Dismantling of wrought iron or mild steel work of any description, as in rafters, purlins and wind ties etc. complete all as specified and directed by Engr-in-charge.
S & F Structural steel/ tubular /box section including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 .St.240 conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed by Engr-in-charge.
M&L for preparation of new steel and iron surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge.
Use and waste of formwork to chullah hoods, chajjas, troughs & similar items including edges with rough, finished surfaces of concrete in flat
Use and waste of form work to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, uttresses, etc.; vertical or to batter with rough finished surfaces of concrete in flat.
Use and waste of formwork to soffits of suspended slabs such as roof slab, floor slab & wall etc. and similar works n. exc 200mm thick (horizontal or sloping) with fair finished surfaces of concrete in flat
VINUBHAI P. CHANDRA
jitendra c joisar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .