Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC | ₹6.8 L Quoted ₹7.0 L | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹7.3 L+₹29,936.25 (4.30%)Rejected-Finance GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL PIN 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | ₹7.3 L+₹29,936.25 (4.30%) | L2 | Rejected-Finance BEING NOT LOWEST |
| 3 | L3₹8.5 L+₹1.5 L (21.9%)Rejected-Finance B 145 VIKAS NAGAR COMMANDER CHOWK NEW DELHI 59 PIN 110059 | WEST DELHI | DELHI | 110059 | ₹8.5 L+₹1.5 L (21.9%) | L3 | Rejected-Finance BEING NOT LOWEST |
| 4 | L4₹9.6 L+₹2.7 L (38.4%)Rejected-Finance 1291 1ST FLOOR SECTOR 26 PANCHKULA HARYANA 134116 | PANCHKULA | HARYANA | 134116 | ₹9.6 L+₹2.7 L (38.4%) | L4 | Rejected-Finance BEING NOT LOWEST |
| 5 | Rejected-Technical 20 C RAGHUVANSH ENCLAVE KALIDAS ROAD DEHRADUN | - | - | Rejected-Technical No, as per WLR CEBZ QE Jun 2022 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
21 Sept 2022, 6:00 pmClosed
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne, Disst- Pauri Garhwal Pin-246155
REP TO SANITARY FITTINGS, PLASTERING, PLINTH PROTECTION WORK AND MISC B/R WORKS AT ZONE-II AGE I LANSDOWNE
2022_MES_548014_1
8768/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I Lansdowne
Class E Cat a i
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹20,000
26 Nov 2022
27 Aug 2022
23 Sept 2022
27 Aug 2022
21 Sept 2022
9 Sept 2022
Amount
Dismantling of water tanks exc 250 ltr and not exc 500 ltr capacity complete all as specified and directed by Engr-in-Charge
Dismantling of water tanks exc 500 ltr and not exc 1000 ltr capacity complete all as specified and directed by Engr-in-Charge
S&F for Rotational moulded polyethylene water storage tanks 500 ltr capacity(cylindrical vertical with closed top) hoisted and fixed in position including PVC float valve all as specified in SSR Part-1 complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks 1000 ltr capacity(cylindrical vertical with closed top) hoisted and fixed in position including PVC Float valve all as specified in SSR Part-1 complete all as specified and directed.
S & F in rep PVC tank cover suitable for 500/1000 ltr capacity incl necessary locking device complete all as specified and directed.
Taking up or down 15 mm bore Gl tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down Gl tubing and connections, including cleaning for refixing or removal to store 20 mm bore complete all as specified and directed.
S & F 15 mm bore Galvanized Steel tubes, medium grade fixed to walls and ceilings or laid in floors complete all as specified and directed.
S & F 20 mm bore Galvanized Steel tubes, medium grade fixed to walls and ceilings or laid in floors complete all as specified and directed.
S & F in rep Gun metal globe 20mm bore or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F in rep 15 mm bore chromium plated pillar taps, cast copper alloy, with captan head screwed down high pressure with or with out lettred Hot or Cold with long screwed shanks and fly nut screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in rep15 mm bore CP brass angle valve, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed for iron pipe complete all as specified and directed.
S & F in rep bib tap 15 mm dia cast copper alloy CP with crutch or butter fly handle screwd for iron pipe or for brass ferrule and fixed complete all as specified and directed
M & L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exc 10 cm girth complete all as specified and directed
S & F in repairs vitreous china squatting pan "orissa pattern" size 580X 440 mm white with integral foot rest (excluding flushing cistern and flush pipe) complete all as specified and directed Make- Parryware, Cera
S&F in repair vireous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including PVC cover complete all as specified and directed Make : Cera/Parryware
S&F in repair PVC valve less syphonic action type flushing cistern 10ltr capacity low level, white/coloured with inlet ball valve flaot and handle including bracket (incl.taking down old cistern ) and fixing of PVC flush pipe 32 mm dia and PVC connection pipes complete all as specified and directed.
S&F in repair health faucet with 1 mtr tube & hook (braded Tube) Make prayag Cat No BEA-85 complete all as specified and directed.
Supply only flush pipe of polythene of low or high density 32 mm PVC for low level flushing cistern complete all as specified and directed
S & F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S & F in repairs CP brass wash hand basin mixure with swinging spout mark Hot and Cold complete all as specified and directed
S & F in repairs CP brass wall mixure three in one with hand shower & accessories with mark Hot and Cold complete all as specified and directed
S & F Vitreous China wash basin, white, flat back, size 550 x 400 mm excluding taps,chain and plug and porcelain washer but including CP waste coupling ,PVC waste pipe & brackets complete all as specified.
S & F in rep Towel rack with lower hanger size 600mm length fixed with and including Chromimum plated brass screws and plastic cleats complete all as specified and directed .
S&F in rep Towel ring round including Chromimum plated brass screws and plastic cleats complete all as specified and directed
Supply and fixing fency type soap dish, chromium plated brass complete all as specified and directed.
S & F Glass corner self fency type three tier with 5.50mm thick glass mounted on CP brass frame fixed with brass screw & plug .Size n less than 450mm as suitable for bath room as per manufacturer instruction complete all as specified .
S&F as in repair stainless steel kitchen plate rack of size 24x36x10 inch of minimum thickness 0.8mm including necessary drilling, fixing with screw, plugs in kitchen etc complete all as specified and directed.
S & F PVC reinforced connections 450x15 mm size with CP check nut and washers complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M & L Non skid light colour ceramic tiles of any design and pattern 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer in CM 1:6. finished fair and even for laying floor finishes/tiles etc complete all as specified and directed. Tiles shall be conforming to IS-15622-2006, Group B II with average water absorption between 3% to 6% length, width and strightness of sides +0.10% (Max deviation). thickness + 5.0% (Max deviation). Centre & edge curvature and warpage +0.50% (Max deviation). breaking strength 1000N (Minimum) and minimum 95% tiles shall be free from visible defects. Note :- Shade of the tiles including colour, design and pattern shall be approved by AGE (I)
S & F glazed ceramic coloured tiles of size 450mmx300mmx 8 to 9mm thick on vertical surface such as skirting, dados, risers to steps etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick cement plaster in CM (1:4) all as specified and directed by Engineer-in-charge. Tiles shall be confirming to IS-15622-2017, Group B III with average water absorption between 10% to 15% length, width and strightness of sides +0.20% (Max deviation) Thickness + 4.0% (Max deviation) straightness of sides and rectangularity +0.15% (Max deviation) surface flatness +0.22% (max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note :- Shade of the tiles including colour, design and pattern shall be approved by AGE (I)
M L joint less non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer in CM 1:6 finished fair and even for laying floor finishes/tiles etc complete all as specified and directed.
M&L Vitrified Ceramic tiles light color 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer in CM 1:6 finished fair and even for laying floor finishes/tiles etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level )and removing unserviceable material,outside cantt area distance not exceeding 1.5 KM complete all as specified and directed.
M&L for 75 mm thick PCC Type D-2, 1:4:8 (using 40mm graded stone agg) as in sub base of flooring complete all as specified and directed by Engr-in-Charge
M&L for Machine cut kota stone slab flooring 20-25 over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including 15mm thick screed bed in cement mortar 1:6 including rubbing and polishing complete all as specified and directed
M&L Chequered cement concrete rubber moulded colored tiles 30cm x 30cm x 25mm thick with grey cement and pigment set jointed and pointed in neat cement slurry in floors including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc and removing unserviceable material,outside cantt area distance not exceeding 1.5 KM. complete all as specified and directed.
Material & labour for Rendering 10 mm thick CM 1:6 on brick/stone masonry surface finished even & fair complete all as specified and directed.
M & L for Rendering 15 mm thick in two layers i.e. 10mm thick in CM 1:6 and 5mm thick in CM 1:4 using water proofing liquid compound as per manufacturer's instructions on other than fair faces brick or concrete surfaces and finishing surfaces even & fair complete all as specified and directed. Note :- Water proofing liquid compound shall be measured and paid separately.
Material & labour for Rendering 5 mm thick CM 1:3 using water proofing liquid compound as per manufacturer's instructions on brick or concrete surfaces of ceiling /chajja's finished even & fair complete all as specified and directed. Note :- Water proofing liquid compound shall be measured and paid separately.
Supply only liquid water proofing compound.ISI marked complete all as specified and directed.
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- 1. The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). after carrying out preparation of surface the same shall be got approved from GE before application of distemper for each building. (v). The colour / shade will be all as approved by GE (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
M&L for preparation of newly plastered surface of internal wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- (i) The new surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper The cost of all material T&P and labour required for preparation of surface are deemed to be included in the rates quoted . (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
M & L preparing of new plastered or un plastered surface of ceilings and applying two coats of white wash complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection and similar works including finishing the surface of concrete topping even & fair, without using extra cement complete all as specified and directed.
Supply only glass dividing strips 38 mm wide and 3 mm thick inserted in position as approved pattern complete all as specified and directed
Demolition Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for Brick work with sub-class `B' bricks, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for plain cement concrete Type D-2(1:4:8) (using 40 mm graded stone aggregate), as in foundation filling and mass concrete including necessary form work as required complete all as specified and directed.
PIONEER REFRIGERATION AND ELECTRICALS
M/s Candid Mask Networks Pvt Ltd
NSK TRADER
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .