Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 LAccepted-AOC 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹48.8 L+₹6.2 L (14.6%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹49.7 L+₹7.1 L (16.6%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹50.1 L+₹7.5 L (17.6%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹50.5 L+₹7.9 L (18.7%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
1 Mar 2021, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-56/2020-21 MANNING AND OPERATION OF DG SET INSTALLED AT ZONE B AT AF STN AMBALA
2021_MES_416412_1
GE AF/AMB-56/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE AF AMBALA
ALL AS PER NIT TENDER DOCUMENTS
11 documents required · 11 mandatory
₹500
GE AF AMBALA
₹90,000
Yes
30 Mar 2021
27 Jan 2021
3 Mar 2021
27 Jan 2021
1 Mar 2021
15 Feb 2021
3 Feb 2021 - 8 Feb 2021
Amount
PART-I (M&O WORKS)
Manning & Operation of substation with 1No. DG set 500kVA (make Cummins) by providing 01 (one) skilled FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays at ATC complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge
Manning & Operation of substation with 3Nos. DG set 250kVA (make Kirloskar) at JS, 01No. DG set 250kVA (make Kirloskar) at 2nd line power house and 1No. DG set 400kVA (make Crompton Greaves) at Parameter S/S by providing 01 (one) skilled FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge
Manning & Operation of substation with 2Nos. DG set 500kVA (make Kirloskar) at IACCS building 601SU and 1No. DG set 62.5kVA (make Kirloskar) at Parameter S/S 601SU by providing 01 (one) skilled FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge
Manning & Operation of substation with 1No. DG set 125kVA (make Kirloskar) at SITC building, 1No. DG set 160kVA (make Kirloskar) at Hangar No. 2 S/S by providing 01 (one) skilled FGM, in 01 (one) shift of 8hours on all days including Sundays and holidays complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Manning & Operation of substations with DG sets 1No. 160kVA (make Kirloskar) at SRE Power House and 1No. 125kVA at WWR Installation (make Ashoke Leyland) by providing 01 (one) skilled FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge
Manning & Operation of substation with 1No. DG set 100kVA, 1No. DG set 125kVA at 5Sqn and 1No. DG set 100kVA at DSS Complex by providing 01 (one) skilled FGM, in 02 (two) shifts of 8hours each (0800 to 1600hrs & 1600hrs to 2400hrs) = 2 FGMs on all days including Sundays and holidays complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Notes for serial item Nos. 1.00 to 7.00: (i) The timings for each shift shall be as decided by the Engineer-in-charge. No claim whatsoever on this aspect is admissible (ii) The minimum wages as derived by the Department including all statutory provision such as EPF, ESIC, Bonus, GST, etc. as applicable except the Contractor's profit for skilled FGM / person works out to Rs. 765/-per person per shift (iii) Bidder has to upload an signed undertaking in firm's letter head confirming that he has not quoted his rates lower than the derived minimum rates of the Department. Bids not accompanied with such undertaking shall not qualify for opening of the price bids. As applicable, his tender will be treated as 'NON BONAFIDE' if found at any stage and will not be considered for acceptance. In such case, the lowest tender shall be determined by the lowest amount amongst valid / bonafide bids only
Notes for serial item Nos. 1.00 to 7.00 contd: (iv) However increased minimum fair wages as notified time to time by the Government of India / State Government / Labour Regulations whichever is higher including all statutory provisions such as EPF, ESI, Bonus, taxes, etc. as applicable, irrespective of derived minimum wages as above (v) Increased wages including all other benefits in compliance of statutory provisions shall be paid to the workers by the Contractor. No other claim whatsoever shall be admissible on this account and the bidders shall note this aspect and quote their rates accordingly. It must be noted that in compliance of all statutory provisions, the increase shall be passed over to the workers (vi) Rates quoted by the bidder shall be deemed to be inclusive of any extra manpower required (if any) for relieving, replacement, etc. and all stipulations as per tender documents (vii) The operator placed shall be responsible to attend complaints concerned to the location/s as directed (viii) Conveyance/vehicle for moving around of the staff employed and or any T&P required and detailed specifics as per particular specifications shall be provided by the Contractor. (ix) A penalty of Rs. 500/- per complaint shall be imposed on non-attending of such complaints as directed. Such penalties shall be recovered immediately from corrosponding RARs/FB of the Contractor.
PART-II (REPAIR & OTHER WORKS)
Taking down copper / aluminium point wiring (light, fan, socket or power) including fixture and fittings viz. switches, ceiling roses, light fittings, pendants, regulators, sockets, etc. and disposing off complete all as specified and as directed
M&L for point wiring with 1.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories concealed on walls, ceiling surfaces etc., and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sheet (1.6mm thick) sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover complete all as specified and as directed for the following:
One light / ceiling fan / exhaust fan point controlled by one 5A one way switch
One 3 pin 6A switch socket combination outlet on independent board
One switch socket outlet 3 pin 5Amps on same board
M&L for point wiring with 2.5sqmm, single core PVC FRLS insulated, heavy duty, ISI marked, unsheathed cable 1100V grade with multistranded copper conductor drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories, concealed on walls, ceiling etc., and PVC insulated heavy duty, ISI marked, unsheathed copper conductor 1.5sqmm for earth continuity conductor and connected to common earth dolly including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sheet (1.6mm thick) sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover for 3 pin 15A switch socket power point on independent board complete all as specified and as directed
M&L for point wiring with 1.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade with multi-stranded copper conductor, drawn through existing non-metallic rigid PVC conduit and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly complete all as specified and as directed for the following:
One light / ceiling fan / exhaust fan point controlled by one 5A one way switch
One 3 pin 6A switch socket combination outlet on independent board
One switch socket outlet 3 pin 5Amps on same board
M&L for point wiring with 2.5sqmm, single core PVC FRLS insulated, heavy duty, ISI marked, unsheathed cable 1100V grade with multistranded copper conductor drawn through existing non-metallic rigid PVC conduit and PVC insulated heavy duty, ISI marked, unsheathed copper conductor 1.5sqmm for earth continuity conductor and connected to common earth dolly for 3 pin 15A switch socket power point on independent board complete all as specified and as directed
S&F switch piano flush button type, single pole, ISI marked, one way 6A, 240V complete all as specified and as directed
S&F switch piano flush button type, single pole, ISI marked, one way 15A, 240V complete all as specified and as directed
S&F switch socket combination outlet, 2 in 1, 3 pin, multipurpose 5A flush type, ISI marked, 240V complete all as specified and as directed
S&F switch socket combination outlet, 2 in 1, 3 pin, multipurpose 15A flush type, ISI marked, 240V complete all as specified and as directed
S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed
S&F PVC lamp holder, insulated body, bracket holder / angle holder 240V complete all as specified and as directed
S&F electronic fan regulator, stepped type (5 steps), 100W, 50Hz, 230V, ISI marked duly connected up complete all as specified and as directed
S&F 1.5m long 40mm bore light grade GI pipe security light bracket duly cut to size and bent to shape required including 2Nos. MS clamps fabricated out of 40x5mm flat iron as required to fix on concrete / steel poles, duly painted with 2 coats of synthetic enamel paint (of approved tint) over a coat of red oxide primer, and taking down and disposing off old unserviceable brackets complete all as specified and as directed
S&F LED tube light fitting 1x18W, 230V, PF 0.9 , CRI> 70, L 70, LM 80, input voltage 90-300V, stranded luminaries efficiency 100lumen/watt, in commercial channel with powder coated CRCA sheet housing with opal diffuser for LED with LED tubelight with high efficient LED in aluminium housing with clear & milky diffuser, with all accessories and connecting with twin core twisted flexible copper conductor cable and suitable size rod including taking down and disposing off old / unserviceable FTL/CFL fitting any type complete all as specified and as directed
S&F LED tube rod fitting, 1x18 watt, 230V with high efficient size rod with all accessories having PF >0.9, input voltage 90-300V, IP-68, LM 80 stranded luminaries efficiency 100lumen/watt with all accessories and connecting with twin core twisted flexible copper conductor cable and suitable size rod including taking down and disposing off old / unserviceable fitting any type complete all as specified and as directed
S&F recess/surface mounting LED flat panel 2'x2' with high efficient LED & glare free full window opal diffuser of 36W, PF 0.9, input voltage 90-300V, IP-68, LM 80, CRI> 70, L 70 with all accessories and stranded luminaries efficiency 100lumen/watt, pre-wired and connecting with twin core twisted flexible copper conductor cable with suitable size rod including taking down and disposing off old / unserviceable fitting any type complete all as specified and as directed
S&F indoor decorative LED batten with opal diffuser with inbuilt LED tube 10W and driver designed with high transmitting optics for even light distribution IP 20 degree protection having length 620mm and PF 0.9, CRI> 70, L 70 and connecting with twin core twisted flexible copper conductor cable including taking down and disposing off old / unserviceable FTL/CFL fitting any typecomplete all as specified and as directed
S&F LED bulk head 10W PF 0.9 , CRI> 70, input voltage 90-300V L 70 IP 68 LM 80 with pressure die cast aluminium housing high efficient LEDs with all accessories and enclosed with milky diffuser, IP 66 protection including connecting with twin core twisted flexible copper conductor cable of suitable size including taking down and disposing off old / unserviceable bulk head fitting any type complete all as specified and as directed
S&F 2 core 10sqmm XLPE insulted armoured heavy duty electric cable with aluminium conductor, 1100V grade, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by and including insulated hangers @ 1m c/c and 4mm dia suspension wire includng taking down old unserviceable cable and disposing off complete all as specified and as directed
S&F 2 core 6sqmm XLPE insulted armoured heavy duty electric cable with aluminium conductor, 1100V grade, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by and including insulated hangers @ 1m c/c and 4mm dia suspension wire includng taking down old unserviceable cable and disposing off complete all as specified and as directed
S&F 2 core 4sqmm XLPE insulted armoured heavy duty electric cable with aluminium conductor, 1100V grade, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by and including insulated hangers @ 1m c/c and 4mm dia suspension wire includng taking down old unserviceable cable and disposing off complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of single core 4sqmm, PVC insulated, FRLS unsheathed suitable for 1100V multistranded copper conducter cable and 1 run of 2.5sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit 20mm bore, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories including taking down old sub-main wiring any type complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of single core 6sqmm, PVC insulated, FRLS unsheathed suitable for 1100V multistranded, copper conducter cable and 1 run of 4sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit 25mm bore, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories including taking down old sub-main wiring any type complete all as specified and as directed
Notes for item Nos. 38 & 39: (i) 2 runs of 4/6sqmm main cable, 1 run of 2.5/4sqmm earth conductors and 1 run of PVC conduit as per item shall be measured as one length (ii) Separate conduit shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of conduit shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of conduit as per requirement at site
S&F LED light fittings 45W, input 110V to 280V, with auto shut down on high voltages, life > 50000hrs, operating temperature 1 to 50oC conforming to IP 65, luminaries comprising of rectangular shaped pressure die cast aluminium housing with weather proof gaskets for lamp and driver compartment with system wattage of 60W =10% W & rated lumens of minimum 5000 lumens with 120 degree view angle, driver shall be constant current type having THD <10% and power factor >0.95 with short circuit protection , open circuit protection, reverse circuit protection, high voltage protection, protection against 10KV high surges, the luminaire having secondary optics with perfectly matched lenses for better light control and complying to IEC60598/IS10322 including changing of clamps, nuts, bolts, washers and painting existing bracket with 2 coats of aluminium paint over a coat of red oxide zinc crome primer with and connecting up with multistranded copper conductor cable 3 core 1.5sqmm from ceiling rose to fitting drawn through existing bracket including taking down and disposing off old / unserviceable HPSV/LED fitting any type complete all as specified and as directed
S&F in repairs MCB SPN, 240V, 6 to 32A, 10kA, 'B' curve, finger proof terminal, bi-connect termination, 35sqmm terminal capacity, insulated sliding shutter with large two position dolly complete all as specified and as directed
S&F in repairs MCB SP, 240V, 6 to 32A, 10kA, 'B' curve, finger proof terminal, bi-connect termination, 35sqmm terminal capacity, insulated sliding shutter with large two position dolly complete all as specified and as directed
S&F in repairs MCB TPN, 415V, 63A, 10kA complete all as specified and as directed
S&F in repairs MCCB TPN, 415V, 100A, 16kA complete all as specified and as directed
S F in repairs MCCB 100Amp, 4 pole 16kA with adjustable thermal release fixed magnetic protection complete all as specified and as directed
S F in repairs MCCB 125Amp, 4 pole 16kA with adjustable thermal release fixed magnetic protection complete all as specified and as directed
S F in repairs MCCB 160Amp, 4 pole 25kA with adjustable thermal release fixed magnetic protection complete all as specified and as directed
S&F in repairs sheet metal enclosures for MCB distribution board 230V, SPN, 4 way, double door type flushed inside wall with 200A rated bus bar and making good the disturbed surfaces complete all as specified and as directed
S&F in repairs sheet metal enclosures for MCB distribution board 230V, SPN, 8 way, double door type flushed inside wall with 200A rated bus bar and making good the disturbed surfaces complete all as specified and as directed
S&F heavy duty, steel body with metal blades, legs, ISI marked energy efficient BEE five star rated exhaust fan, 230/240V, single phase, 450mm sweep with louvers and connecting up including cutting into brick walls, etc. to make suitable opening, provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts complete all as specified and as directed
S&F heavy duty, steel body with metal blades, legs, ISI marked energy efficient BEE five star rated exhaust fan, 230/240V, single phase, 250/3000mm sweep with louvers and connecting up including cutting into brick walls, etc. to make suitable opening, provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts complete all as specified and as directed
S&F energy efficient BEE five star rated ceiling fan, 230/240V, single phase, 1200mm sweep and connecting up with provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to ceiling fan complete all as specified and as directed
S&F in repairs air termination, single pointed aluminium rod 12mm dia and 300mm long including suitable insulated base plate and connecting up complete all as specified and as directed
M&L for test point terminal block made of gun metal phosphorus bronze, size 75x75x25mm, drilled and screwed with sheet metal enclosure of size 100x100x100mm fabricated out of steel sheet not less than 1.6mm thick and including 3Nos. 8mm dia 25mm long hexagonal head screws complete all as specified and as directed
Supplying, fixing / laying steel water tubing, 40mm bore, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables complete all as specified and as directed
M&L for plain cement concrete in 1:3:6 (type C-2) using 40mm graded stone aggregates as bed blocks, bed to air termination rods including necessary formwork complete all as specified and as directed
S&F copper strip of size 20x3.15mm with saddles and fixing screws, etc. for roof conductors, down conductors and wall conductors above the ground, etc. brazed/welded at each joint complete all as specified and as directed
S&F GI strip of size 32x6mm with saddles and fixing screws, etc. for roof conductors, down conductors and wall conductors above the ground, etc. complete all as specified and as directed
S&F aluminium strip of size 25x3.15mm with saddles and fixing screws, etc. for roof conductors, down conductors and wall conductors above the ground, etc. brazed/welded at each joint complete all as specified and as directed
M&L for taking off old earthing strips with insulator, realigning earthing strips and refixing including providing new insulators complete all as specified and as directed
M&L for earthing with copper earth plate electode 600x600x3.15mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including copper strip of size 20x3mm to the extent of 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed
M&L for earthing with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth strip of size 32x6mm to the extent of 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed
Notes for serial item Nos. 62 & 63: (i) The cost of copper / GI earth continuity wire with GI pipe 50mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge (iv) The earth resistance shall be less than 01Ohm / as desired by the installation. A guarantee for 3years of this criterion on a Rs. 100 stamp paper shall be given by the Contractor. The quoted rate shall be deemed to be inclusive of this aspect
MAHESH GAUR AND CO.
Esha Engineers
Swami Engineers
Baliyan Electrical Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .