| 1 | L1₹34.3 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹34.3 L Quoted ₹35.9 L | L1 | Accepted-AOC Accepted for acceptance being lowest. |
| 2 | L2₹38.5 L+₹2.6 L (7.24%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | ₹38.5 L+₹2.6 L (7.24%) | L2 | Rejected-Finance Not L1. |
| 3 | L3₹38.9 L+₹3.0 L (8.27%)Rejected-Finance | ₹38.9 L+₹3.0 L (8.27%) | L3 | Rejected-Finance Not L1. |
| 4 | L4₹39.2 L+₹3.2 L (8.99%)Rejected-Finance | ₹39.2 L+₹3.2 L (8.99%) | L4 | Rejected-Finance Not L1. |
| 5 | L5₹39.9 L+₹4.0 L (11.2%)Rejected-Finance | ₹39.9 L+₹4.0 L (11.2%) | L5 | Rejected-Finance Not L1. |
Tender Value
₹34.9 L
EMD Value
₹70,000
Closing Date
10 Jul 2023, 6:00 pmClosed
GE (AF) Jamnagar No.2
Air Force-II, Udhyog Nagar, Jamnagar - 361004
REPAIR AND MAINTENANCE OF EXTERNAL ELECTRIC SUPPLY ITEMS, STREET LIGHT, UG CABLE AND CONNECTED ITEMS AT AF STATION KHAMBHALIA AND DWARKA UNDER GE (AF) JAMNAGAR NO.2
2023_MES_602323_1
8442/E8
Open Tender
Miscellaneous Works
Item Rate
330 days
Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No.2
₹70,000
Yes
1 Sept 2023
9 Jun 2023
11 Jul 2023
9 Jun 2023
10 Jul 2023
23 Jun 2023
Amount
Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil for taking up/laying cable/pipe etc completed all as specified and directed.
Returning, filling including spreding, leveling watering & well ramming in laying not exc. 25cm for Soft/loose soil completed all as specified and directed.
Removal of excavated material at a distance not exc 50 mtr and dipositing where directed at a level not exc. 1.5 mtr above the starting point for Soft / loose soil completed all as specified and directed.
M & L for dry Sand cushioning to underground cable with screened, washed river sand, including punning gently completed all as specified and directed. Note: Thickness after punning will be measured for payment.
Supply and lay burnt brick sub class `B' old size in trenches abouting each other width equal to length of brick etc completed all as specified and directed.
Laying only burnt bricks (old size) retrieved from item No.6, laid in trenches as cable protection completed all as specified and directed.
Supply and laying in trenches in road cross / floors tube galvanished iron light grade with all fittings for protection of cable of following dia/bore of pipe :-
(a) 40 mm bore
(b) 50 mm bore
Supply and lay in replacemet and testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of size 95 Sqmm 3.5 Core completed all as specified and directed. Note:-Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.
Supply and lay in replacement and testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of size 35 Sqmm 3.5 Core completed all as specified and directed. Note:-Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.
Supply and lay in replacement and testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with standerd aluminum conductor, 1100 Volts grade, of size 50 Sqmm 3.5 Core completed all as specified and directed. Note: Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.
Supply and lay in replacement and testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with standerd aluminum conductor, 1100 Volts grade, of size 70 Sqmm 3.5 Core completed all as specified and directed. Note: Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.
Supply and laying in replacement XLPE insulated PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor 1100 volt grade of size 25 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing completed all as specified and directed. Note: Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.
Supply and laying in replacement XLPE insulated PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing completed all as specified and directed. Note: Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.
Servicing and cleaning of LT panel of any size with oiling, greasing to door panel, welding of broken door door with hinges to make it properly fitted, change the unserveciable connector, connection wire and MCCB as required completed all as specified and directed. Note- MCCB will be paid separately
Servicing of transformer upto 400 KVA/200 KVA at carrying out insulation resistant test (HT-LT, HT-E & LT-E), BDV of Oil (top & bottom sample), Filtration & topping up of oil, test, quaterly resistance check of earth pits, arresting of leakage by proper tightening of terminals& joints, replacement of loose or burnt out gasket & proper sealing of valves etc completed all as specified and directed.
Note: (i)The cost involved for oil filtration & topping with new mineral oil will be measured & paid separately. (ii) The contractor should produce all testing certificates immediately after testing .Moreover testing should be carried out by authorized OEM only. (iii) The contracted labour manning the substation should immediately inform any oil leakage,change in colour of silica gel, level down of oil in conservator etc.
Dehydration / filtration of transformer oil of transformers, of various capacities installed in different locations in Khambhalia and Dwarka by recirculation existing transformer oil with trolley mounted filtration plant till dielectric strength is up to 40 KV to 50 KV. Note- Quoted rates shall be deem to include for following:- (i) Oil shall be tested after filtration and test result will be recorded before & after filtration of oil. (ii) Contractor should make his own arrangement for oil filtration plant including transportation complete.
M & L for topping up of transformerr oil having dielectric strength 50 KV or so, as per IS specification in various electrical equipment installed at AF Station, khabhalia or Dwarka completed all as specified and directed. Make : SAVITA/POWER/BP/HP/IO
S&F in repair Electrical insulation matts, Classs"A" width 1 Mtr, Thickness 2.0 mm working grade 3.3 KV, Breakdown voltage : 30KV, all other specification confirming to IS : 15652-2006, ISI Market,synthetic mats, Fire Retardant, Blue/Black in colour completed all as specified and directed. Make- Safe Volt of TATA RUBBER CORPORATION / SINTEX / ELECTROMAT / JYOTI
S&F in replacement worn out HT terminal with bush of existing size for transfomers upto 500 KVA capacity to arrest leakage by opening top cover and refixing the same with replacement of worn out gasket completed all as specified and directed.
S&F in replacement worn out LT terminal with bush of existing size for transfomers upto 500 KVA capacity to arrest leackage by opening top cover and refixing the same with replacement of worn out gasket completed all as specified and directed.
S&F in replacement breather with accessories of transformer as existing including silca jel completed all as specified and directed.
M & L for Servicing of Servo controlled voltage stabilizer 300/200 KVA, 415Volt including setting of Input and Output voltage completed all as specified and directed. Note:- Spare required for replacement if any will be measured and paid separately.
M & L for filtration of oil for voltage stabilizer & alike filled at various electrical equipment installed at AF khambhaliya and dwarka with filtration machine to achieve dielectric strength 40 to 50 KV per 2 minutes gap as per IS specificationcompleted all as specified and directed.
M & L for topping up of voltage stabilizer oil having dielectric strength 50 KV or so, as per IS specification in various electrical equipment installed at AF Station, khambhalia or Dwarka completed all as specified and directed. Make : SAVITA/POWER/BP/HP/IOC
Note for item No.24 & 25 1. Labour for draining out of oil & refilling the same is deemed to be included in quoted rates. 2. Cost of minor spares ie nut bolt and washer if required to complete the job is deemed to be included in quoted rates.
Supply following spares only for servo controlled voltage stabilizer of 300/200 KVA
Shunt Trip coil of any size
Cut out PCB,3-phase
Control PCB
control wire
RC network for 10 KG motor
Sensing Transformer for Analog control
Stabiliser carbon Brush for Dimmer
Control wire with Glass fuse
S&F in repair digital voltmeter 0-500 volts of size 96x96mm completed all as specified and directed. Make : C&S/BHEL/ABB/SIEMENS
S&F in repair digital Ampere meter 0-500 A of size 96x96mm completed all as specified and directed. Make : C&S/BHEL/ABB/SIEMENS
S&F in repair Red/Yellow/Blue LED indicating lamp (Set of three lamp), 240 volts, AC completed all as specified and directed.
S&F in repair Red luminous push button with LED indicating lamp and 1NC Element completed all as specified and directed. Make : Schneider/Siemens/L&T or equivalent
S&F in repair Green luminous push button with LED indicating lamp and 1NC Element completed all as specified and directed. Make : Schneider/Siemens/L&T
Taking out U/S LT underground cable of any size 1100 volt grade & bricks, tracing out the defects, rectify the same, making servicable by removing/cutting U/S & burnt out part, jointing with straight through joint of suitable size, testing with megger etc including all associated earth work like excavation/returning filling/removal excavated material and sand filling completed all as specified and directed. Note : Straight through joints will be measured and paid separately.
Relaying of serviceable LT cable retrieved from item No 30 after cutting into pieces serviceable portion of following Sizes including all associated earth work like excavation/returning filling/removal excavated material and sand filling completed all as specified and directed.
Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32x6mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 50mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 1991, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion completed all as specified and directed.
Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth wire 4.0 mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 50mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 1991, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion completed all as specified and directed.
Supply and installed cubicle compartmentalised outdoor type APFC panel of Cap 80 KVAR, factory made,double door front and rear opening with locking arrangement, dust and vermin proof, CPRI approved, fabricated out of 2.5 to 3.0mm thick CRCA sheet with canopy and base frame & mild steel angle iron stand, over all finished with epoxy powder coating, suitable for operation on 415 Volts, 50 Hz, AC supply, including earthing stud, labeling, danger plates etc. and section pillar box shall comprising the following complete including fixed in position, connect with electric supply complete all as specified and directed by EIC.
OUTGOING 20 KVAR FEEDER (a) 50A TP,10 KA MCB ,D Curve(Make-Schneider/L&T))-01 Nos (d) Capacitor Duty Contactor, 20 KVAR, 230V AC (Make-Schneider/L&T))-01 Nos (e) Capacitor Bank 20 KVAR, MPP Heavy Duty, 440V AC (Make-Schneider/L&T))-01 Nos (f)Indicating Lamp - LED Type-RED, 230V AC (Make-Rass)-01 No (g)Flush Type,Pushbutton START, STOP(make-Rass)-02 Nos 15 KVAR FEEDER (a) 32A TP MCB, 10KA, D Curve (make-Schneider /L&T)- 2 Nos. (b) Capacitor Duty Contactor, 15 KVAR, 230V AC (Make-Schneider /L&T)- 2 Nos. (c) Capacitor Bank 15 KVAR, MPP Heavy Duty, 440V (Make-AC Schneider /L&T)- 2 Nos. (d) Indicating Lamp - LED Type-RED, 230V AC ON (make-Rass) -02 Nos. (e) Flush Type, Pushbutton -START, STOP (make-Rass)-04 Nos.
10 KVAR FEEDER (a)25 A TP MCB, 10KA, D Curve (make-Schneider /L&T)- 2 Nos. (b) Capacitor Duty Contactor, 10 KVAR, 230V AC (Make-Schneider /L&T)- 2 Nos. (c) Capacitor Bank 10 KVAR, MPP Heavy Duty, 440V AC (Make-AC Schneider /L&T)- 2 Nos. (d) Indicating Lamp - LED Type-RED, 230V AC ON (make-Rass) -02 Nos. (e) Flush Type, Pushbutton -START, STOP (make-Rass)-04 Nos. 05 KVAR FEEDER (a)16 A TP MCB, 10KA, D Curve (make-Schneider /L&T)- 2 Nos. (b) Capacitor Duty Contactor, 5 KVAR, 230V AC (Make-Schneider /L&T)- 2 Nos. (c) Capacitor Bank 05 KVAR, MPP Heavy Duty, 440V AC (Make-AC Schneider /L&T)- 2 Nos. (d) Indicating Lamp - LED Type-RED, 230V AC ON (make-Rass) -02 Nos. (e) Flush Type,Pushbutton -START, STOP (make-Rass)-04 Nos BUSBARS:- ALUMINIUM 01 Mains:-20X10 mm-1Nos./Phase & 20X6 mm-1 No./Neutral 02 Earth:- 25x6 mm
M&L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one finishing coat of paint completed all as specified and directed.
M&L Anti climbing devices, comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered completed all as specified and directed. Make : Clamps measured separately.
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size completed all as specified and directed.
M&L for stay assembly complete with accessories as shown in electrical plate No.1 completed all as specified and directed. Note : Loop type and concrete measured separately.
Pin type, porcelain,vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron nut, 150mm dia for 11000 volts grade completed all as specified and directed.
S&F lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for HT 11 KV complete all as specified as directed.
S&F switch are break gang operated triple pole, mechanically operated, mounted on insulator and steel frame, with operating machanism worked from ground level, for current rating upto 200 Amp suitable for 11000 Volts completed all as specified and directed.
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp completed all as specified and directed.
All as per Item No 42 above but 40 W
Supply and fix in repair LED power supply driver suitable for Primary:220-240 VAC , 50/60Hz suitable for 9/10watt LED bollard fitting Secondary: constant current DC:300mA with thermal, overload and short circuit protection including taking out old/unsv completed all as specified and directed.
Supply and fix in repair LED power supply driver suitable for Primary:220-240 VAC , 50/60Hz suitable for 40watt post top fitting Secondary: constant current DC:300mA with thermal, overload and short circuit protection including taking out old/unsv completed all as specified and directed.
Supply and fixing LED light fitting 1x30 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size completed all as specified and directed.
S&F in repairs of 25 mm bore tube galvanished iron Light grade fixed to poles, walls and ceiling etc. with all fittings (Clamps for fixing) for protection of cable completed all as specified and directed.
Material & Labour for preparation of old painted surface of steel tubular pole (9/11 meter long above coping) or Cemented POLE and applying two coat of oil enamel paint or cement paint , making of strip of 20 cm width (sky blue and white in alternate band) upto 1400 mm height with one synthetic enamel paint, rewriting pole No by painter with enamel paint, and painting the existing MS clamp with one coat of aluminum paint completed all as specified and directed.
Material and labour for writting of Pole Nos on existing pole with stencil out with white colour in sky blue colour background of 80 mm hight around the radius of pole and completed all as specified and directed.
Supply and fix timer switch Digital type 24 hours with 15 min and 30 min, 16/100 Amp contact rating 230 volts AC 50 Hzs suitable for street lights and completed all as specified and directed. Make : Legrand Cat Part No.CX3 CT 230V 2NO 40 A or equivalent in Phillips/Crompton
Supply and fixing 3 pole power contactor type ML 2 AC 3 rating(32 A) Aux Contactors 2NO+2NC Cat No SS90701 of Make- L&T compatible with digital timer of suitable capacity completed all as specified and directed.
Supply and fixing 4 pole power contactor type MCX 21 AC 1 rating (100 A) Make- L&T or equivalent suitable capacity completed all as specified and directed.
Supply and fixing 4 pole power contactor type MCX 32 AC 1 rating(160A) Aux Contactors 2NO+2NC Cat No CS 97020 of Make- L&T compatible with digital timer of suitable capacity completed all as specified and directed.
Supply and fixing 4 pole power contactor type MCX 33 AC 1 rating(160A) Aux Contactors 2NO+2NC Cat No CS 97021 of Make- L&T compatible with digital timer of suitable capacity completed all as specified and directed.
Supply and fix MCB’s single pole with neutral, 6 to 32 Amps, 250 volts with ‘B’ curve,10 KA fixed in existing PVC box including connecting completed all as specified and directed.
Supply and fix MCB TPN, 40 to 100 Amps, 250 volts with ‘B' curve, 10 KA fixed in existing PVC box including connecting completed all as specified and directed.
Disconnecting the existing unserviceable PVC box and Supply and fix PVC box of outside size 350mm x 250mm x 150mm and inside size 300mm x 200mm x 105 mm including 4 Nos of bus bar strip of aluminium of size 25x4 mm suitable for 440 volts of suitable amps rating including 1 No MCB SPN ,6 to 32 Amps, 250 volts with 'C' curve, to be fixed on pole with clamp completed all as specified and directed.
Dismantling and taking down defective / unserviceable LED street lights fitting and flood lights of any type and of any description and capacity from 09/11 high electric pole and gates completed all as specified and directed.
Supply and fix in replacement 200-210 Watt LED flood light with pressure die- cast aluminium housing, complete with all accessories, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purposelighting W Turo Floodlight luminaires with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 Protection fixed in existing clamp and connecting with existing cable, including nuts, bolts and washer etc completed all as specified and directed. Make :Havells (Ordering Code - LHFPCZBFP46J200), Bajaj, C&S, Orient or equivelent approved by GE
Supply and fix in repair LED street light fitting of 60 W sealed optic luminaire with housing made of die cast aluminium with smooth finish powder coated for better environmental protection complete all as specified below:- (i) The fixture shall be designed so as to ave lumen maintenance of at least 70% at the end of 70000 hours. (ii) The luminaire should be operable with auto adjustable 120-240 volt supply using the same driver. Ambient temperature at LED should not be more that 70 degree centigrade. (iii) Power factor of the electronic driver should be at least 0.90 abd efficiency of the luminaire to be more than 85%. (iv) The fixture should be dark sky complaint. The fixture should use aluminium, MCPCB printed circuit boards for better thermal management. (v) The luminaire should throw the perfect amount of uniform lught with exactly the desired intensity, and best pole spacing, along with better light control. (vi) The luminaire shall employ indivdual optical lens for the each of the LED's to ensure better uniformity of light distribution. (vii) The fixute should be vibration resistance, if the fixture is also to be used in vibration prone areas like flyovers/bridges. (viii) Heat dissipation should be managed through a built in external heat sink. (ix) Colour rendering index of minimum 65 with color temprature of 4000K.Make : Orient or equivalent of C&S/Bajaj/Havells/Crompton Graves
All as per Item No 60 above but 35 W light
Supply and fix only driver of LED light suitable for model-30/60W NEO K completed all as specified and directed. Make : crompton graves
M & L for repairing the Existing LED Streeet light drivers for light Model 30 / 60 W NEO K by taking down the unserviceable LED street light drivers from the street light and repairing/replacing the unserviceable parts of drivers like internal wiring etc and refitting the same with all connection after making serviceable completed all as specified and directed. Note : Drivers to be paid saperately.
Supply and fix in repair PVC insulated FRLS copper conductor wire of 2 core 1.5 sqmm from existing syntex box to light fitting completed all as specified and directed.
Taking down of unserviceable High mast street light fittings of any type, any description and of any capacity upto 16 metre high steel tubular high mast electric pole completed all as specified and directed.
Supply and laying in repair XLPE insulated PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor 1100 volt grade of size 10 Sqmm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing completed all as specified and directed. Note:-Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.
Material and labour for preparation of old painted surface of electrical panel inner and outer surface complete of size length (0.5 m to 1 m), Height (1 m to 2 m) and Breadth (upto 0.5 m) by scrubbing with iron brush and applying two coats of synthetic enamal paint with spray machine completed all as specified and directed.
Material and labour for preparation of old painted surface of electrical panel inner and outer surface complete of size length (1 m to 2 m), Height (1 m to 2 m) and Breadth (upto 0.5 m) by scrubbing with iron brush and applying two coats of synthetic enamal paint with spray machine completed all as specified and directed.
S&F Glow sign board of size 1.5 m x 0.9 m x 0.20 m made out of 1.0 mm thick tin sheet all side except front side aluminium beading "L" shape at all boarder exterier and interier side, front should be acrylic cover 2.0 mm thick of blue colour and written the subject matter as given by the Engr-in-charge in english capital letter in white colour with twin tubelight fitting 1x28 watt (2 nos) including all electrical connection with surface conduit wiring 1.5 Sqmm (length not exceeding 8 meter) copper wire with drilling and necessary required arrangement for fixing of board including testing completed all as specified and directed.
S&F in repair cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 120 Sqmm 3.5 core completed all as specified and directed.
S&F in repair cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 95 Sqmm 3.5 core completed all as specified and directed.
S&F in repair cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 70 Sqmm 3.5 core completed all as specified and directed.
S&F in repair cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 50 Sqmm 3.5 core completed all as specified and directed.
S&F in repair cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 35 Sqmm 3.5 core completed all as specified and directed.
S&F in repair cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 25 Sqmm 4 core completed all as specified and directed.
S&F in repair cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 10 Sqmm 2 core completed all as specified and directed.
M&L for colour coding of earthing pit cover with the following colors: Red for chemical earth pit & yellow for conventional earth pit.The numbering/marking of earth pit will be in capital black colour & is to be done completed all as specified and directed.
M&L for construction of earthing chamber internal size 600 x 600 x 600 mm in repairs and making coping for funnel with PCC 1:2:4 type B1 using 20mm graded stone aggregate all with MS Angle 40x40x4mm frame work duly painted with all corrosive bituminous paint and including RCC slab 50 mm thick in cement concrete (1:2:4) type B1 reinforced with XPM (weight not less than 3 Kg per Sqm) having lifting arrangement including dismantling old earthing chamber completed all as specified and directed.
Supply and erect in true vertical position Prestressed concrete pole, 9.0 metres long. of size 102mm x 152mm at top and 102 mm x 289mm at bottom class 10 completed all as specified and directed. Note: (i) PCC foundation & coping shall be measured & paid separately.(ii) Excavation earth work and PCC will be measured and paid for seperately under respective item of schedule "A".
M&L for plain cement concrete 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete in foundation of poles completed all as specified and directed.
M&L for cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in benching, coping, including weathering slightly rounded or chamfered angles completed all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 (using 20mm graded crushed stone aggregate) as in foundation, filling and mass concrete in foundation of stay assembly complete all as specified.
Disconnecting the existing Unserviceable MCCB of 63 A Capacity, taking out from the panel board and supply and fix new MCCB four pole of 63 Amps, 25 KA breaking capacity as per site requrement ,exiting capacity suitable for 415 Volt, 50 Hz, 4 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc completed all as specified and directed. Make- C&S or equivelent
Disconnecting the existing Unserviceable MCCB of 100 A Capacity, taking out from the panel board and supply and fix new MCCB four pole of 100 Amps, 25 KA breaking capacity as per site requrement ,exiting capacity suitable for 415 Volt, 50 Hz, 4 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc completed all as specified and directed. Make- C&S or equivelent
Disconnecting the existing Unserviceable MCCB of 125 A Capacity , taking out from the panel board and supply and fix new MCCB four pole of 125 Amps, 25 KA breaking capacity as per site requrement,exiting capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc completed all as specified and directed. Make- C&S or equivelent
Disconnecting the existing Unserviceable MCCB of 200 Capacity , taking out from the panel board and supply and fix new MCCB four pole of160 Amps, 35 KA breaking capacity as per site requrement,exiting capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc completed all as specified and directed. Make- C&S or equivelent
SURESH ELECTRICALS
M/s Shivan Enterprise
Sukhi Electricals
Dara Paras.D
suvidhiconstruction
rajengineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .