CIVIL WORKS
WTP works
Survey, Investigation, Soil Testing, Planning, Design and Drawing construction, commissioning etc. as per design and drawing provided by the contractor all in accordance with the relevant latest I.S. Codes and approved by the Engineer as per conditions of the bid documents. The design and drawings provided by the contractor should be Vetted by any IIT Institute or Government Engineering College approved by the Engineer, on contractor's cost. For construction of 20 MLD WTP on latest technology, Admin Building with Command Control Room, and fire fighting arrangements, first aid arrangements Cascading Aerator, Inlet chamber, alum dosing, pre-sedimentation Tank/Rapid Mix/Vertical Flow Clarifloculator/Rapid Gravity Filter with Back Wash Arrangement/Proper Sludge Disposal and Backwash water disposal arrangements to nearest drain/low laying area& Appurtenant Works of the above-mentioned capacity, automated through PLC with outputs to SCADA, walkway in between WTP components with railing, Guard Room, Chemical Store House, Gaseous Chlorination Plant, Development of WTP area with adequate plantation, Rainwater harvesting unit. Lean concrete to be used of grade not less than M-15 and other structures in minimum M-30 grade of concrete. Cement and steel should be as per approved by the Engineer/IS code. Collapsible MS steel doors and aluminum windows to be provided including of three-coat whitewashing, internal two coat white cement painting, external painting with apex ultima/equivalent paint, all steelwork must be painted with red oxide paint and two coat of anticorrosive paint etc. and internal and external electrification with adequate LED lights for the compound, including automation, instrumentation & SCADA, wireless telemetry (voice & data), including Water Testing Kits, Lab Building and essential lab equipment as mentioned in the related Items Including of supply of all materials, labor T&P etc required for proper completion of works as per direction of the Engineer. All works complete as per design and drawing approved by engineer incharge. contractor will have to provide four wheelers, two wheelers, with fuel & driver for supervision of work and computer/laptop with operator as mentioned in tender document. (Only Civil Work)
INTAKE WELL WORKS
Survey, Investigation, Soil Testing, Planning, Design and Drawing, construction, commissioning etc. as per design and drawing provided by the contractor all in accordance with the relevent latest I.S. Codes and approved by the Engineer as per conditions of the bid documents. The design and drawings provided by the contractor should be vetted by any IIT Institute or Government Engineering College approved by the Engineer, on contractor's cost. For construction of Intake Well (for Hamirpur Npp & Kurara Np) of minimum internal size of 10.00M Dia & required Height with required length & 3.5 M width foot bridge , water inlet opening having minimum intake capacity to meetout the raw water required for WTP by different inlet points, construction of stair case, Pump house, Balcony, stair case post column beams etc. Such that to fix required nos. of VT Pump mention in item number 267. Power Control Panels, starters, intrumentation and SCADA & wireless telemetry (Voice & Data), internal and external electrification with adequate LED lightings including Excavation in soil i.e. Kankar mixed morrom/soft/hard rock and lean concrete of minimum grade of M-15 and R.C.C. in grade M-30 or above, in raft/ pile foundation, Intake R.C.C wall with supply of all type of steel bars of approved quality and cement OPC 53/43 grade of any make approved by the Employer as per design and drawings and binding the same including binding materials, diversion arrangement of flow during construction by making bundh across the dam supply gunny bags, sand, their filling suitable size of steel garder, with chain puli arrangement, dismantling and refixing etc. and also supply and fixing of collapsible gate, collapsible door, almunium window as per relevent specifications also including of three coat white washing, internal two coat snowcem painting, external painting with appex ultima or equivalent paint, all steel work must be painted with red oxide paint and two coat of anticorrosive paint etc. and internal and external electrification of intake well, supply and fixing of three-row of 20 mm dia G (Midium) pipe railing with 65X65X6 mm M.S. Angle iron posts. Supply and fixing of aniet opening of required capacity as per requirements including of supply of all materials, labour, T&P etc. required for proper completion of works as per direction of the Engineer. Cost of VT Pumps, panels, SCADA panel board, pipe manifolds etc. are not covered in this item.
Rising Main & By Pass arrangement
Supply of following sizes of DI pipes, class K-9 with rubber gasket, conforming to IS: 8329/2000 (reaffirmed year 2020) or its latest amendments, F.O.R. destination including insurance etc. complete
600 mm dia D.I. Class K-9
600 mm dia D.I. Class K-7
500 mm dia D.I. Class K-7
400 mm dia D.I. Class K-7
400 mm dia D.I. Class K-9
300 mm dia D.I. Class K-9
250 mm dia D.I. Class K-9
200 mm dia D.I. Class K-9
100 mm dia D.I. Class K-9
Supply of Specials for above pipe F.O.R destination including all Taxes and insurance.
Carting of the following sizes of D.I. Pipes (class K-9) and specials to the site of work, lowering them in to trenches and laying true to alignment and gradient including testing of pipeline (but excluding cost of trenching and cuttling of pipes etc. for making of lengths but including making joints)
600 mm dia D.I. Class K-9
600 mm dia D.I. Class K-7
500 mm dia D.I. Class K-7
400 mm dia D.I. Class K-7
400 mm dia D.I. Class K-9
300 mm dia D.I. Class K-9
250 mm dia D.I. Class K-9
200 mm dia D.I. Class K-9
100 mm dia D.I. Class K-9
Excavation for pipeline trenches including lift upto 1.5 m and lead upto 50 m and refilling, watering, ramming of excavated, earth in to the trenches and disposal of surplus earth upto 50 m from the center of the trenches
In soil mixed with moorum/ shingle/ kankar/rock
Supply & fixing of following sizes of C.I. Double flanged sluice valves as per IS 14846: 2000 (Reaffirmed Year: 2020) or its lastest amendment, class - 1 F.O.R. destination including insurance.
600 mm dia
500 mm dia
400 mm dia
300 mm dia
250 mm dia
200 mm dia
Carting of D/F Sluice valves of following sizes to the site of works lowering them into already prepared trenches and fixing them In position including supply of jointing materials such as bolt nut, rubber insertion white lead complete with excluding values and specials required but including the testing etc. complete .
600 mm dia
500 mm dia
400 mm dia
300 mm dia
250 mm dia
200 mm dia
Supply & fixing of C.I. Air valve
Carting of air valve of 50mm to the site of works lowering them into already prepared trenches and fixing them In position including supply of jointing materials such as bolt nut, rubber insertion white lead complete with excluding values and specials required but including the testing etc. complete .
Supply and fixing of 100 mm dia. size of C.I. Double flanged scour valve as per IS: 780 class 1 F.O.R. destination including all taxes and insurance.
Carting of scour valve of 100mm to the site of works lowering them into already prepared trenches and fixing them In position including supply of jointing materials such as bolt nut, rubber insertion white lead complete with excluding values and specials required but including the testing etc. complete .
Supply of Swing Check Type NRV Valve including all Taxes and insurance etc.Complete(500mm) as per IS: 780 class 1 F.O.R. destination including all taxes and insurance.
Supply of all materials, labour, T&P and construction of following chambers as per type design including supply and materials, labour and T&P, testing etc. complete.
Masonry Type
Air Valve chamber
Scour Valve chamber
Dismantling of following type of road surfaces for lying of pipe line including sorting out of serviceable materials and disposal of unserviceable materials.
Bituminous Road
Reinstatement of following type of road surfaces for laying of pipe line including sorting out of serviceable materials and disposal of unserviceable materials.
Bituminous Road
Supply of all materials, labour, and T & P etc. and construct R.C.C. thrust blocks at bends and below valves as required.
R.C.C. work in 1:1.5:3 with mild steel work
Provision for Large crossing of nala,raod & culverts including shiftijng of telephone cabel etc.along the alignment of pipe line including supply of C.I Tyton pipe and special and also jointing material their laying and jointing testing etc,complite.(FOR 7.0 M WIDE )
NOC for Forest Depatment of Clear Water 500mm Dia
Distribution System
Supply of the following D.I. pipes (K-7) conforming to 1.8 -8329/2000 (reaffirmed year 2020) or its latest amendment(s). Including F.O.R. destinations rate per metre in Rs., anywhere in U.P. including cost of one Rubber Gasket per pipe length & inclusive of Third Party Inspection Charges, Packing & Forwarding Charges, Transit Insurance Charges, Road Transportation Charges etc.
400 mm dia D.I. Class K-7
350 mm dia D.I. Class K-7
300 mm dia D.I. Class K-7
250 mm dia D.I. Class K-7
200 mm dia D.I. Class K-7
Supply of Specials for above pipe F.O.R destination including all Taxes and insurance.
Supply of the following HDPE Pipes as per I.S. 4984/2016 or its latest amendment inclusive of 3rd party inspection charges, packing and forwarding charges, trasnit insurance charges, road transportation charges etc. F.O.R. destination etc. complete.
HDPE Pipe PN 6: class PE 100
110 mm dia
140 mm dia
160 mm dia
Supply of Specials for above pipe F.O.R destination including all Taxes and insurance.
Excavation for pipe line trenches in Ordinary soil,(lime, clay or sand Including lift up to 1.5m and lead up To 50m and refilling, watering, Ramming of excavated earth in to trenches and disposal of surplus earth up to 50 m from the center of the foundation trenches.
In soil mixed with moorum/ shingle/ kankar/rock
Carting of following pipes, specials and fittings to site of work, lowering them into trenches, laying true to alignment and gradient, laying and jointing of pipe line including cutting of pipe for making up lengths as required for proper completion of work. HDPE pipes shall be joined by electrfusion welding fittings and welding equipement, ensuring proper surface preparation,alignment and cooling time.
HDPE Pipe PN 6: class PE 100
110 mm dia
140 mm dia
160 mm dia
DI Pipe K-7
200 mm dia
250 mm dia
300 mm dia
350 mm dia
400 mm dia
Supply & fixing of following sizes of C.I. Double flanged sluice valves as per IS 14846: 2000 (Reaffirmed Year: 2020) or its lastest amendment, class - 1 F.O.R. destination including insurance.
Sluice Valves
350 mm dia
300 mm dia
250 mm dia
200 mm dia
150 mm dia
125 mm dia
100 mm dia
Scour Valves
100 mm dia
Air Valves
40 mm dia
Fire Hydrants
80 mm dia
Carting of valves of following sizes to the site of works lowering them into already prepared trenches and fixing them In position including supply of jointing materials such as bolt nut, rubber insertion white lead complete with excluding values and specials required but including the testing etc. complete .
Sluice Valves
350 mm dia
300 mm dia
250 mm dia
200 mm dia
150 mm dia
125 mm dia
100 mm dia
Scour Valves
100 mm dia
Air Valves
40 mm dia
Fire Hydrants
80 mm dia
Supply construction of following chambers as per type design including supply and materials labour, T&P etc. complete.
Surface Box Type
Masonry Type
Air Valves
Fire Hydrants
Dismantling of following type of surface including sorting out and staking of serviceable materials and disposal of unserviceable material up to a distance of 50m.
BOE Road
Bituminous Road
CC Road
Inter locking Road
Reinstatment of following type of road including supply of all material, labour etc complete. All works complete as per design and drawing approved by engineer incharge
BOE Road
Bituminous Road
CC Road
Inter locking Road
Provision for Large crossing of nala,raod & culverts including shiftijng of telephone cabel etc.along the alignment of pipe line including supply of C.I Tyton pipe and special and also jointing material their laying and jointing testing etc,complite.(FOR 7.0 M WIDE )
Provision for Small crossing of nala,raod & culverts including shiftijng of telephone cabel etc.along the alignment of pipe line including supply of C.I Tyton pipe and special and also jointing material their laying and jointing testing etc,complite.(FOR 3.5 M WIDE )
Trenchless Crossing For Rising Main Distribution
Supply of MS pipe (As per IS:3589 made from steel confirming to IS:2062), with anti corrosive treatment with P.U. coating and Installation of product pipe by HDD method including preparing and setting up the plants and equipement, preparing new pipe work material, installation new pipe-work and commissioning system or making the system ready for commissioning by HDD operation including, all related civil and mechanical works like excavation, shoring/strutting, etc. drilling, stringing, reaming, and pulling back the new pip-work on the designed bore path alignment, proper disposal of drilling fluid, and back fill of site after completion all inclusive as per IndSTT:101:2018: Code of prectice of HDD Technique Suiting Indian Conditions.
200mm dia to 300mm dia pipe, 10mm Pipe Wall Thickness
350mm dia to 450mm dia pipe, 10mm Pipe Wall Thickness
500mm dia to 600mm dia pipe, 10mm Pipe Wall Thickness
650mm dia to 900mm dia pipe, 12mm Pipe Wall Thickness
House connection on New Pipeline
Provision of House connection including Supply of all materials, labours T&P etc required for proper completion of work. (as following)
Making House Connection with distribution main including dismantling of road, supply, carting of specials, Lowering them into trances, fixing them in proper alignment and jointing including bailing out to water, necessary excavation for connection including all labour, T&P etc. required for proper completion of the work. All works complete as per design and drawing approved by engineer incharge
In BOE Road
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm to 250 mm dia
In C. C. Roads
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm to 250 mm dia
In Bituminous Roads
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm to 250 mm dia
In Interlocking Roads
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm to 250 mm dia
In Earthen Roads
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm to 250 mm dia
Converting existing house connections to new distribution pipelines of various sizes, including supply and carting of specials, trenching, pipe laying and jointing (using existing serviceable and new materials such as 20mm HDPE, 20mm GI, saddles, couplers, elbows, bib cocks, etc.), alignment, dewatering, excavation, barricading, road dismantling and road reinstatement. Includes all labor, T&P, materials, and incidentals for completion in all road types.
In BOE Road
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm to 250 mm dia
For 300 mm dia
In C. C. Roads
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm to 250 mm dia
For 300 mm dia
In Bituminous Roads
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm to 250 mm dia
For 300 mm dia
In Interlocking Roads
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm to 250 mm dia
For 300 mm dia
In Earthen Roads
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm to 250 mm dia
For 300 mm dia
RCC OHT
Supply of all materials, labour, T&P etc, and construct an RCC over head tank of following capacity with RCC staircase and 1m wide balcony, G.I. Pipe and angle iron posts around the balcony and at the dome periphery, M.S. ladder from the balcony to the top of tank and inside the tank, supply and fixing M.H. cover with locking device, ventilator; lightening conductor, water level indicator, fixing of puddle collars and bell mouths, supply and fixing M.S. clamps with RCC coloumn, 25 mm thick PCC 1:2:4 floor over 80 mm PCC 1:4:8 in appron, 150 mm semicircular drain around the tank, escape channel of 20m length, box type enclosure at the entrance of the staircase having locking arrangements, three coat cement paont & three coat apex ultima and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary CI D/F pipes and valves etc. all complete including site clearance and other unforeseen items for following zones. All Components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S. 456. Minimum depth of foundation below original ground level will be 2.0 M. Seismic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure. The assumed bearing capacity of soil has been taken as 8 M.T. sqm.1m wide two column RCC stair case from ground lavel to balcony. M.S. ladder made of 50 X 50 X 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony to top dome resting on an RCC platform (75 X 75 cm and 10 cm thick) projecting from top ring beam and one aluminum ladder inside the tank body ( from manhole in top dome to bottom dome). 1 m wide R.C.C. balcony around the tank at the junction point of vertical wall and conical wall. Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, around the balcony at each landing from landing with top ring beam upto manhole on the top dome and at the periphery. The G.I. pipes will be supported on R.C.C. posts of 100 mm dia or on the posts made of 50 X 50 X 6 mm M.S. angle section, spaced at intervals not more than 1.5 m. Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50 m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia. The space between top dome and R.C.C. cover should be covered with mosquito net of slandered quality along with expended mantled. Electro Magnetic Flow Meter. Lightening conductor as per I.S.S. 2309 of its latest amendments of latest electricity rules. It should consist proper elevation rod with 5 or more fork points proper down conductors of prescribed mental of proper size prescribed by ISS 2309-1969 and ISS 3013-1966. D.I. manhole of min 60 X 60 cm size made of M.S. channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking arrangement. This manhole should be fixe at top dome at proper place. Supply, fixing, jointing of following size of D.I. D/F Pipes with D.I. D/F specials conforming to IS 8329/2000 as vertical pipes for inlet, outlet, over flow and washout as per latest / relevant I.S. specifications with all jointing materials for proper completion of work including other appurtenant works and excavation in all types of soil. Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each duck foot bend to support the vertical pipes. These bed blocks should supported on the raft not on the soil. Construction of surface box type Sluice valve chamber for above sluice valve (3 No.) as per departmental type design and drawing including supply and fixing of 150 mm x 150 mm size C.I. surface box including locking arrangement. Construction of washout/ overflow chamber as per departmental type design and drawing. Construction of P. C. C. Floor & Drain and all other necessary work as per departmental type drawing and design. Painting of all concrete surface and steel pipe works with three coats of approved cement paint and anticorrosive paints. Testing & Commission etc. all complete work.
Zone-1 Hamirpur
900 KL with 25 m Staging ( inlet 300mm, outlet 300mm, overflow 300mm, wash out 100mm)
Zone-1 A Hamirpur
1000 KL with 24 m Staging ( inlet 250mm, outlet 350mm, overflow 250mm, wash out 100mm)
Zone-3 Hamirpur
900 KL with 24 m Staging ( inlet 200mm, outlet 350mm, overflow 350mm, wash out 100mm)
Zone-4 Hamirpur
1800 KL with 24 m Staging ( inlet 300mm, outlet 400mm, overflow 300mm, wash out 100mm)
Zone-5 Hamirpur
900 KL with 24 m Staging ( inlet 200mm, outlet 350mm, overflow 200mm, wash out 100mm)
Zone-6 Hamirpur
350 KL with 24 m Staging ( inlet 125mm, outlet 250mm, overflow 150mm, wash out 100mm)
Zone-3 Kurara
600 KL with 24 m Staging ( inlet 200mm, outlet 250mm, overflow 200mm, wash out 100mm)
CPT at WTP
150 KL with 20 m Staging ( inlet as pumping plant design, outlet 500mm, overflow 200mm, wash out 100mm)
Testing of bearing capacity of soil from a reorganized Govt. Engineering College or as directed by department.
RCC CWR
Supply of all materials, labour, T&P etc. and construct an RCC CWR of following capacity with RCC structures G.I. Pipe and angle iron posts around the top of sump. M.S. ladder inside the tank, supply and fixing M.H. cover with locking device, ventilator, lightening conductor, water level indicator, fixing of puddle collars and bell mouths, supply and fixing M.S. clamps with RCC coloumn, 25 mm thick PCC 1:2:4 floor over 80 mm PCC 1:4:8 in appron, 150 mm semicircular drain around the sump, escape channel of 20m length and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary CI D/F pipes and valves etc. all complete including testing of bearing capacity of soil and site clearance and other unforeseen items for following zones/sub zones.
MCWR at WTP
CCWR at Zone 1 Hamirpur
CWR at Zone 3 Hamirpur
CWR at Zone 3 Kurara
Cost for testing of bearing capacity of soil for various sites for proposed water works.
STAFF QUARTER
Construction of Staff Quarter including all materials, labour, T&P Complete as per departmetal type & design drawing.
At CWR full room set Zone 02/Zone06 for Devision office
At CCWR Zone 01 Half set
At CWR Zone 04 Half set
At CWR Zone 06 Half set
At CWR Kurara Half set
ESTIMATE OF MASTER CONTROL ROOM, HT, LT PANEL & METER ROOM
Construction of Room including all materials, labour, T&P Complete as per departmetal type & design drawing.
Master Control Room (5x4.5x4 M)
HT Room (5x4.5x4M)
LT Room (5x4.5x4M)
Meter Room (4x3x3M)
BOUNDARY WALL, GATE SITE DEVELOPMENT & APPROACH ROAD
Provide all materials, labour T&P etc. required for proper completion of work and construct Boundary wall.
Provide all materials, labour T&P etc. required for proper completion of work and construct pillars as per type design and fixing of gate 3.6 m wide gate and 1 m wide wicket gate.
3.60 m wide gate & 1m. Wicket Gate
Provide all materials, labour T&P etc. required for proper completion of work and construct Interlocking approach road in water works campous.
Provide all materials, labour T&P etc. required for proper completion of work including levelling, dressing excavation and filling of earth where necessary for develop of water works site including carriage of earth.
Construction of 300x300 mm size drain at W/W sites
At WTP Site
At w/w Site Zone-I, II,IV,V and VI and Kurara Zone-3
Estimate of Repairing of 500 KL/18.0M,600 KL/ 20M AND 1000KL/20M Staging Over Head Tank
Providing and erection of scaffolding and shuttering material like challi, gurra, nail, bans, ballia, patra etc. required for complete of work on all surface area of OHT from top dome to G.L. so as to give strong and safe platform to workers to work on all part of OHT for repair and strengthening as per direction of engineer in-charge.
Repairing of OHT and Plastering.
Provide semi circular drain of 200 mm dia all around the O.H.T. flooring consisting of cement concrete with 20mm gauge approved stone grit, coarse sand, cement in proportion of 1:2:4 including supply of all material, labour, T&P etc. required for proper completion of the work as per direction and satisfaction of Engineer In charge.
Supply and fixing ventilator jali at O.H.T. including repairing of the ventilator and fixing the same properly including supply of all material, labour, T&P etc. required for proper completion of the work.
Supply and fixing of fabricated M.S. angle iron ladder consisting of 50x50x6mm angle iron and 20mm dia plain M.S. bar of 45 cm wide for a required length and painted with anti corrosive paint and fixing the same in the tank body including supply of all materials, labour, T&P etc. required for proper completion of the work as per direction of Engineer Incharge.
Supply and fixing of 20mm dia medium quality of G.I. pipe railing with M.S. angle iron post of section 50x50x6mm and 1.00 M height including grouting the angle iron post properly and fixing the pipe railing including supply of all material, labour, T&P etc. required for proper completion of the work as per direction of Engineer Incharge.
New Pipe Railing ¾" (20mm) dia medium quality.
Repair of Old Railing.
M.S. iron for single raw post 50x50x6x1.00m height
Supply and fixing of following devices of the O.H.T. including cutting of hole for cleats to fix the same properly and including supply of all material, labour, T&P etc. and fixing the appliances in the cleats with screw or nails etc.
Water level indicator complete with marked scale.
Lightening Conductor.
Injection grouting in vertical surface/wall placing and fixing nozzle by drilling machine in tank wall having minimum dia of nozzle 15mm and provide on a regular interval not exceeding 1m including construction joints. Injection of pidicrete AM (Polymer based on shrinkage high strength grout) admixed with cement through nozzle under pressure by sump @ 250gms per bag of cement sealing the nozzle after fronting with Polymer product mixed with cement, making tank body in working and seepage free condition.
Painting the iron work in small area with one coat of anti corrosive primer coat and two coat of approved enamel paint including supply of all material, labour, T&P etc. required for proper completion of the work as per satisfaction of Engineer Incharge.
Railing of stair case and balcony with iron post and two rows of G.I. pipe 20mm dia.
Painting with approved quality Black Japan paint, inlet, outlet, washout pipe, over flow, pipe 100mm dia to 350mm dia.
Painting of outer surface of OHT with weather proof paint (like apex etc.) as per direction of engineer in-charge.
Construction of masonry type chamber for Sluice Valve with R.C.C. Cover.
E/M Works
INTAKE WELL AT BETWA RIVER
PUMPING PLANTS:
Supply, installation, testing and commissioning of Oil lubricated Vertical Turbine Raw water pump alongwith all necessary arrangements to complete with 23 m column assembly ,TEFC motor B class insulation with reversible ratchet, chuck nut and top shaft locking arrangement suitable to operate on 415 volt, 3 Phase 50 HZ AC supply. (Synchronous Speed 1450 RPM)
7650 LPM, 100 HP, 36 m Head, 1450 RPM ( Head ,discharge & hp may vary as per site condition)
SITC of 75 Kw or more as per site condition with best engineering manner digital Soft Starter with RS485 port - 400 V class for INTAKE Motors
Supply and laying of 3 core 50 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc. in 02 runs with all material labour t&P
A) MAIN PIPING- Supply of CIDF/DIDF 300 mm Main piping required for delivery side, 500 mm common Header upto 1 m outside with 3 Nos 500x300x500 mm size Tee and 1 Nos 500x300x500 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer . complete in all respect as per site conditions . ( size of delivery & common header may increase as per site condition)
Nut , bolt & rubber packing
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 300 mm size( Size may increase as per site condition with best engineering manner)
ii) 500 mm size( Size may increase as per site condition with best engineering manner)
b) SITC of following size DIDF/CIDF Non Return Valves
i) 300 mm size( Size may increase as per site condition with best engineering manner)
ii) 500 mm size( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 500 mm( Size may increase as per site condition with best engineering manner)
ELECTRICAL ITEMS:
Supply & laying of 3.5 core 185 Sq.mm. Armoured Aluminum Conductor Cable From 02 nos of Transformer to LT panel with lugs etc. in 02 runs with all material,labour T&P
SITC of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of followint rating:
(i) 630 Amp or more as per site condition
SITC of dust and vermin proof LT Pannel with electrically and mechanically interlocked 02 nos. incoming of 800 Amp ACB for 02 nos transformer and 3 Nos. (2+1) 250 Amp , 2 Nos 63 amp and 2 nos 32 amp outgoing MCCB Mirco processor based complete suitable to operate on 415±6 % volt , 3 phase , 50 Hz, AC supply with CT'S, PT, AVF meter, PF meter, Relays , protective device and have sufficient space for soft starters of pumping plant complete in all respect. individual motors In cubical type pannel fabricated in compartmentalised (as per instructions of Enginer incharge) from CRC sheet of 2 mm thick for frame work ,2.5 mm thick for cover and 3mm for gland plates with 7 tank process for Powder coating in approved shade
SITC of 125 kvar APFC panel suitable for above LT panel with all necessary metering and protective devices complete in all respect.
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
SITC of CE/UL Certified Radar type Level Transmiter for Intake well.
SITC of CE/UL Certified Surge protector for control panel
Double Plate Earthing of complete Pumping Station (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
SITC of 5Ton capacity hand operated overhead travelling (HOT) crane suitable for span up to 6 mtrs and travelling length upto 10 mtrs with clear lift up to 6 mtrs including gear type chain pulley block and geared travelling trolley complete with all accessories including girder.
Tools
10 mm Thickness Electrical resistance sheet
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
Fire fighting equipments such as four nos. fire extinguishers CO2/ ABC type.
Internal & External electrification and lighting (illumination) and ventillation (including bird guard /exhaust fan if required) of pumping station including concealed conduit or duct wiring with any electrical item required for proper completion of work
Lightining of INTAKEWELL campus
S/F of Ms Tubular poles SP36 9.5 m height with junction box
S/f of @x40 w LED Green Grace light lumen 120w colour warm white as per required illumination level
S/f of unarmoud aluminium cable 6sq mm 2 core for connection of above light through junction box
Painting of pumping plant and all other E/m equipment with all labour & T& P
Installation, Testing and Commissioning of all equipments and pumping plants etc complete in all respect.
WTP 20 MLD
EPC contract for a 20.0 MLD Water Treatment Plant at Betwa river, including detailed design and drawings; SITC of all electro-mechanical works with latest SCADA-based automation; integration with approved civil structures; all materials, labour, and T&P; wetted-parts design subject to Engineer-in-Charge approval; adequate standby units and spares; and complete gaseous chlorination system (1W + 1S) for pre- and post-treatment with chlorine analyzers, leak detection and absorption system with full safety tools, complete in all respects.
PUMPING PLANTS:
SITC of Vertical Turbine water lubricated Clear Water Pump with 4.5 mt column assembly along withVHS,TEFC,IE-3 Electric motor complete with ratchet arragment chucknut and top shaft locking arragment with following specifications.
7350 LPM, 100 HP, 33 m Head, 1450 RPM (head,discharge 7 hp may vary as per site condition)
SITC of 75 Kw or more as per site condition with best enginnering manner digital Soft Starter with RS485 port - 400 V class for MCWR Motors
Supply and laying of 3 core 50 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc. in 02 runswith all material ,labour T&P
A) MAIN PIPING- SITC of CIDF/DIDF 300 mm Main piping required for delivery side, 500 mm common Header upto 1 m outside with 3 Nos 500x300x500 mm size Tee and 1 Nos 500x250x500 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer nuts, bolts, rubber packing etc. complete in all respect as per site conditions . ( Size may increase as per site condition with best engineering manner)
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 300 mm size( Size may increase as per site condition with best engineering manner)
ii) 500 mm size( Size may increase as per site condition with best engineering manner)
b) SITC of following size DIDF /CIDF Non Return Valves
i) 300 mm size( Size may increase as per site condition with best engineering manner)
ii) 500 mm size( Size may increase as per site condition with best engineering manner)
SITC ofCE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 500 mm for MCWR outlet( Size may increase as per site condition with best engineering manner)
SITC of Flow Control Valve
300 mm dia( Size may increase as per site condition with best engineering manner)
500 mm dia( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
SITC of CE/UL Certified level transmitter for CCWR
Electrical Item
Supply and laying of 3.5 core 300 Sq.mm. Armoured Aluminum Conductor Cable from Transformer to Lt Panel with lugs etc. in 02 runs with all material,labour T&P
Supply & laying of 3.5 core 120 Sq.mm. Armoured Aluminum Conductor Cable from LT Panel to WTP Panel with lugs etc. in 02 runs with all material,labour, T&P
SITC of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of followint rating:
(i) 630 Amp. Or more as per site condition
SITC of dust and vermin proof Lt Panel with electrically and mechanically interlocked consisting of 2 Nos incoming Mirco processor based ACB of 800 Amp( 02 for transformer ) , 3 Nos. outgoing Mirco processor based MCCB of 250 Amp for 03 nos for pumping plant ,320 amp Mirco processor based MCCB for 02 nos for WTP, 4 No 63 Amp MCCB Mirco processor and 04 nos 32 amp MCCB microprossor based for Lighting /Spare complete or suitable capacity to operate on 415±10 % volt , 3 phase , 50 Hz, AC supply with power wiring, Ampere meter, Voltmeter ,CT'S, PT, AVF meter, PF meter, Relays, protective device and have sufficient space for soft starters of pumping plant complete in all respect. etc. wiring, CT'S, PT, AVF meter, PF meter, Relays and protective device , Ampere meter, Voltmeter etccomplete in all respect. In cubical type pannel fabricated in compartmentalised (as per instructions of Enginer incharge) from CRC sheet of 2 mm thick for frame work ,2.5 mm thick for cover and 3mm for gland plates with 7 tank process for Powder coating in approved shade
SITC of CE/UL Certified Surge protector for control panel
SITC of 125 kvar APFC panel suitable for above LT panel with all necessary metering and protective devices complete in all respect.
SITC of CE/UL Certified Radar type Level Transmiter for MCWR
Double Plate Earthing of complete Pumping Station (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
SITC of 5Ton capacity hand operated overhead travelling (HOT) crane suitable for span up to 6 mtrs and travelling length upto 10 mtrs with clear lift up to 6 mtrs including gear type chain pulley block and geared travelling trolley complete with all accessories including girder.
10 mm Thickness Electrical resistance sheet
Tools
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type .
Internal & External electrification and lighting (illumination) of pumping station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
Painting of pumping plant and all other E/m equipment with all labour & T& P
Installation, Testing and Commissioning of all above equipments and pumping plants etc complete in all respect.
CWR (KAURARA)
PUMPING PLANTS: (for Zone 1)
SITC of Vertical Turbine water lubricated Clear Water Pump with 4.5 mt column assembly along with VHS,TEFC,IE -3 Electric motor complete with ratchet arragment chucknut and top shaft locking arragment with following specifications.
700 LPM, 10 HP, 32 m Head, 1450 RPM (head,discharge & Hp may vary as per site condition)
SITC of 7.5 Kw or more as per site condition with best enginnering manner digital Soft Starter with RS485 port - 400 V class for CWR Motors
Supply and laying of 3 core 16 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc.
A) MAIN PIPING- SITC of CIDF/DIDF 100 mm Main piping required for delivery side, 150 mm common Header upto 1 m outside with 3 Nos150x100x150 mm size Tee and 1 Nos 150x100x150 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer nuts, bolts, rubber packing etc. complete in all respect as per site conditions .( Size may increase as per site condition with best engineering manner)
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 100 mm size( Size may increase as per site condition with best engineering manner)
ii) 150 mm size( Size may increase as per site condition with best engineering manner)
b) SITC of following size DIDF/CIDF Non Return Valves
i) 100 mm size( Size may increase as per site condition with best engineering manner)
ii)150 mm size( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 150 mm for CWR common header( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
SITC of CE/UL Certified level transmitter for CCWR
PUMPING PLANTS: (For Zone 2)
SITC of Vertical Turbine water lubricated Clear Water Pump with 5 mt column assembly along with VHS,TEFC,IE3 Electric motor complete with ratchet arragment chucknut and top shaft locking arragment with following specifications.
700 LPM, 15 HP, 34 m Head, 1450 RPM ( head, discharge & Hp may vary as per site condition)
SITC of 15 Kw or more as per site condition with best engineering manner digital Soft Starter with RS485 port - 400 V class for CWR Motors
Supply and laying of 3 core 16 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc.
A) MAIN PIPING- SITC of CIDF/DIDF 100 mm Main piping required for delivery side, 150 mm common Header upto 1 m outside with 3 Nos 150x100x150 mm size Tee and 1 Nos 150x100x150 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer nuts, bolts, rubber packing etc. complete in all respect as per site conditions .( Size may increase as per site condition with best engineering manner)
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 100 mm size( Size may increase as per site condition with best engineering manner)
ii) 150 mm size( Size may increase as per site condition with best engineering manner)
b) SITC of following size DIDF/CIDF Non Return Valves
i) 100 mm size( Size may increase as per site condition with best engineering manner)
ii)150 mm size( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 150 mm for CWR common header( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
SITC of CE/UL Certified level transmitter for CCWR
PUMPING PLANTS:( For Zone 3)
SITC of Vertical Turbine water lubricated Clear Water Pump with 5 mt column assembly along with VHS,TEFC,IE3 Electric motor complete with ratchet arragment chucknut and top shaft locking arragment with following specifications.
750 LPM, 15 HP, 38 m Head, 1450 RPM ( head ,discharge & hp may vary as per site condition)
SITC of 15 Kw or more as per site condition with best enginnering mannerdigital Soft Starter with RS485 port - 400 V class for CWR Motors
Supply and laying of 3 core 16 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc. in 02 runs
A) MAIN PIPING- SITC of CIDF/DIDF 100 mm Main piping required for delivery side, 150 mm common Header upto 1 m outside with 3 Nos 150x100x150 mm size Tee and 1 Nos 150x100x150 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer nuts, bolts, rubber packing etc. complete in all respect as per site conditions .( Size may increase as per site condition with best engineering manner)
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 100 mm size( Size may increase as per site condition with best engineering manner)
ii) 150 mm size( Size may increase as per site condition with best engineering manner)
b) SITC of following size DIDF/CIDF Non Return Valves
i) 100 mm size( Size may increase as per site condition with best engineering manner)
ii)150 mm size( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 150 mm for CWR common header( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
SITC of CE/UL Certified level transmitter for CCWR
Electrical Item
Supply and laying of 3.5 core 120 Sq.mm. Armoured Aluminum Conductor Cable from TRANSFORMER TO LT Panel with lugs etc. in 02 runs
SITC of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of followint rating:
(i) 250 Amp. Or more as per required
SITC of dust and vermin proof Lt Panel with electrically and mechanically interlocked consisting of 2 Nos incoming Mirco processor based MCCB of 320 Amp( 02 for transformer ) , 03 Nos. outgoing Mirco processor based MCCB of 32 Amp for 03 nos of zone 1 pumping plant, 06 nos of 63 Amp MCCB Mirco processor for zone 2& 3 pumping plants and 06 nos 32 amp and 04 nos 63 amp MCCB microprossor based for Lighting /Spare complete or suitable capacity to operate on 415±10 % volt , 3 phase , 50 Hz, AC supply with power wiring, Ampere meter, Voltmeter ,CT'S, PT, AVF meter, PF meter, Relays, protective device and have sufficient space for soft starters of pumping plant complete in all respect. etc. wiring, CT'S, PT, AVF meter, PF meter, Relays and protective device , Ampere meter, Voltmeter etccomplete in all respect. In cubical type pannel fabricated in compartmentalised (as per instructions of Enginer incharge) from CRC sheet of 2 mm thick for frame work ,2.5 mm thick for cover and 3mm for gland plates with 7 tank process for Powder coating in approved shade
SITC of CE/UL Certified three phase Surge protector for control panel at main switch
SITC of 75 kvar APFC panel suitable for above LT panel with all necessary metering and protective devices complete in all respect.
SITC of CE/UL Certified Radar type Level Transmiter for CWR
Double Plate Earthing of complete Pumping Station (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
SITC of 3Ton capacity hand operated overhead travelling (HOT) crane suitable for span up to 6 mtrs and travelling length upto 10 mtrs with clear lift up to 6 mtrs including gear type chain pulley block and geared travelling trolley complete with all accessories including girder.
10 mm Thickness Electrical resistance sheet
Tools
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type .
Internal & External electrification and lighting (illumination) of pumping station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
Painting of pumping plant and all other E/m equipment with all labour & T& P
Installation, Testing and Commissioning of all above equipments and pumping plants etc complete in all respect.
CCWR (HAMIRPUR)
PUMPING PLANTS: (for Zone 1)
SITC of Vertical Turbine water lubricated Clear Water Pump with 5 mt column assembly along with VHS,TEFC,IE -3 Electric motor complete with ratchet arragment chucknut and top shaft locking arragment with following specifications.
1100 LPM, 20 HP, 39 m Head, 1450 RPM (Head,discharge & hp may vary as per site condition)
SITC of 15 Kw or more as per site condition with best enginnering manner digital Soft Starter with RS485 port - 400 V class for CWR Motors
Supply and laying of 3 core 10 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc in 02 runs with all material,labour,T&P.
A) MAIN PIPING- SITC of CIDF/DIDF 150 mm Main piping required for delivery side, 200 mm common Header upto 1 m outside with 3 Nos200x150x200 mm size Tee and 1 Nos 200x150x200 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer nuts, bolts, rubber packing etc. complete in all respect as per site conditions .( Size may increase as per site condition with best engineering manner)
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 150 mm size( Size may increase as per site condition with best engineering manner)
ii) 200 mm size( Size may increase as per site condition with best engineering manner)
b) SITC of following size DIDF/CIDF Non Return Valves
i) 150 mm size( Size may increase as per site condition with best engineering manner)
ii)200 mm size( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 200 mm for CWR common header( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
SITC of CE/UL Certified level transmitter for CCWR
PUMPING PLANTS: (For Zone 1A)
SITC of Vertical Turbine water lubricated Clear Water Pump with 5 mt column assembly along with VHS,TEFC,IE3 Electric motor complete with ratchet arragment chucknut and top shaft locking arragment with following specifications.
1250 LPM, 20 HP, 39 m Head, 1450 RPM ( head ,discharge & hp may vary as per site condition)
SITC of 15 Kw or more as per site condition with best enginnering manner digital Soft Starter with RS485 port - 400 V class for CWR Motors
Supply and laying of 3 core 10 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc. in 02 runs with all material,labour ,T&P
A) MAIN PIPING- SITC of CIDF/DIDF 150 mm Main piping required for delivery side, 200 mm common Header upto 1 m outside with 3 Nos200x150x200 mm size Tee and 1 Nos 200x150x200 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer nuts, bolts, rubber packing etc. complete in all respect as per site conditions .( Size may increase as per site condition with best engineering manner)
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 150 mm size( Size may increase as per site condition with best engineering manner)
ii) 200 mm size( Size may increase as per site condition with best engineering manner)
b) SITC of following size DIDF/CIDF Non Return Valves
i) 150 mm size( Size may increase as per site condition with best engineering manner)
ii)200 mm size( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 200 mm for CWR common header( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
PUMPING PLANTS:( For Zone 2)
SITC of Vertical Turbine water lubricated Clear Water Pump with 5 mt column assembly along with VHS,TEFC,IE3 Electric motor complete with ratchet arragment chucknut and top shaft locking arragment with following specifications.
1200 LPM, 20 HP, 35 m Head, 1450 RPM ( head ,discharge & hp may vary as per site condition)
SITC of 15 Kw or more as per site condition with best engineering manner digital Soft Starter with RS485 port - 400 V class for CWR Motors
Supply and laying of 3 core 10 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc. in 02 runs
A) MAIN PIPING- SITC of CIDF/DIDF 150 mm Main piping required for delivery side, 200 mm common Header upto 1 m outside with 3 Nos200x150x200 mm size Tee and 1 Nos 200x150x200 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer nuts, bolts, rubber packing etc. complete in all respect as per site conditions .( Size may increase as per site condition with best engineering manner)
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 150 mm size( Size may increase as per site condition with best engineering manner)
ii) 200 mm size( Size may increase as per site condition with best engineering manner)
b) SITC of following size DIDF/CIDF Non Return Valves
i) 150 mm size( Size may increase as per site condition with best engineering manner)
ii)200 mm size( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 200 mm for CWR common header( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
PUMPING PLANTS:( For Zone 3 & OHT of Zone 4)
SITC of Vertical Turbine water lubricated Clear Water Pump with 5 mt column assembly along with VHS,TEFC,IE3 Electric motor complete with ratchet arragment chucknut and top shaft locking arragment with following specifications.
4500 LPM, 100 HP, 58 m Head, 1450 RPM ( head ,discharge & hp may vary as per site condition)
SITC of 75 Kw digital Soft Starter with RS485 port - 400 V class for CWR Motors
Supply and laying of 3 core 50 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc. in 02 runs with all material labour t&P
A) MAIN PIPING- SITC of CIDF/DIDF 250 mm Main piping required for delivery side, 400 mm common Header upto 1 m outside with 3 Nos 400x250x400 mm size Tee and 1 Nos 400x250x400 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer nuts, bolts, rubber packing etc. complete in all respect as per site conditions .( Size may increase as per site condition with best engineering manner)
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 250 mm size( Size may increase as per site condition with best engineering manner)
ii) 400 mm size( Size may increase as per site condition with best engineering manner)
b) SITC of following size DIDF/CIDF Non Return Valves
i) 250 mm size( Size may increase as per site condition with best engineering manner)
ii)400 mm size( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 400 mm for CWR common header( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
SITC of epoxy coated Flow control valve
300 mm dia( Size may increase as per site condition with best engineering manner)
Electrical Item
Supply and laying of 3.5 core 300 Sq.mm. Armoured Aluminum Conductor Cable from TRANSFORMER TO LT Panel with lugs etc. in 02 runs with all material labour, T&P
SITC of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of followint rating:
(i) 630 Amp. Or more as per required condition
SITC of dust and vermin proof Lt Panel with electrically and mechanically interlocked consisting of 2 Nos incoming Mirco processor based ACB of 800 Amp( 02 for transformer ) , 09 Nos. outgoing Mirco processor based MCCB of 63 Amp for zone 1,1A &2 pumping plant, 03 nos of 320 Amp MCCB Mirco processor for zone 3& 4 pumping plants and 04 nos 32 amp and 04 nos 63 amp MCCB microprossor based for Lighting /Spare complete or suitable capacity to operate on 415±10 % volt , 3 phase , 50 Hz, AC supply with power wiring, Ampere meter, Voltmeter ,CT'S, PT, AVF meter, PF meter, Relays , protective device and have sufficient space for soft starters of pumping plant complete in all respect. etc. wiring, CT'S, PT, AVF meter, PF meter, Relays and protective device , Ampere meter, Voltmeter etccomplete in all respect. In cubical type pannel fabricated in compartmentalised (as per instructions of Enginer incharge) from CRC sheet of 2 mm thick for frame work ,2.5 mm thick for cover and 3mm for gland plates with 7 tank process for Powder coating in approved shade
SITC of CE/UL Certified three phase Surge protector for control panel at main switch
SITC of 225 kvar APFC panel suitable for above LT panel with all necessary metering and protective devices complete in all respect.
SITC of CE/UL Certified Radar type Level Transmiter for CWR
Double Plate Earthing of complete Pumping Station (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
SITC of 5Ton capacity hand operated overhead travelling (HOT) crane suitable for span up to 6 mtrs and travelling length upto 10 mtrs with clear lift up to 6 mtrs including gear type chain pulley block and geared travelling trolley complete with all accessories including girder.
10 mm Thickness Electrical resistance sheet
Tools
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type .
Internal & External electrification and lighting (illumination) of pumping station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
Painting of pumping plant and all other E/m equipment with all labour & T& P
Installation, Testing and Commissioning of all above equipments and pumping plants etc complete in all respect.
CWR (HAMIPUR)
PUMPING PLANTS: (for Zone 3)
SITC of Vertical Turbine water lubricated Clear Water Pump with 5 mt column assembly along with VHS,TEFC,IE -3 Electric motor complete with ratchet arragment chucknut and top shaft locking arragment with following specifications.
1100 LPM, 20 HP, 38 m Head, 1450 RPM ( head ,discharge & hp may vary as per site condition)
SITC of 15 Kw or more as per site condition with best enginnering manner digital Soft Starter with RS485 port - 400 V class for CWR Motors
Supply and laying of 3 core 10 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc.in 02 runs with all material,labour,T&P
A) MAIN PIPING- SITC of CIDF/DIDF 150 mm Main piping required for delivery side, 200 mm common Header upto 1 m outside with 3 Nos200x150x200 mm size Tee and 1 Nos 200x150x200 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer nuts, bolts, rubber packing etc. complete in all respect as per site conditions .( Size may increase as per site condition with best engineering manner)
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 150 mm size( Size may increase as per site condition with best engineering manner)
ii) 200 mm size( Size may increase as per site condition with best engineering manner)
b) SITC of following size DIDF/CIDF Non Return Valves
i) 150 mm size( Size may increase as per site condition with best engineering manner)
ii)200 mm size( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 200 mm for CWR common header( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
SITC of CE/UL Certified level transmitter for CCWR
PUMPING PLANTS: (For Zone 5)
SITC of Vertical Turbine water lubricated Clear Water Pump with 5 mt column assembly along with VHS,TEFC,IE3 Electric motor complete with ratchet arragment chucknut and top shaft locking arragment with following specifications.
1150 LPM, 25 HP, 55 m Head, 1450 RPM (head,discharge & hp may vary as per site condition)
SITC of 22 Kw or more as per site condition with best enginnering manner digital Soft Starter with RS485 port - 400 V class for CWR Motors
Supply and laying of 3 core 16 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc. in 02 runs with material labour t&p
A) MAIN PIPING- SITC of CIDF/DIDF 150 mm Main piping required for delivery side, 200 mm common Header upto 1 m outside with 3 Nos200x150x200 mm size Tee and 1 Nos 200x150x200 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer nuts, bolts, rubber packing etc. complete in all respect as per site conditions .( Size may increase as per site condition with best engineering manner)
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 150 mm size( Size may increase as per site condition with best engineering manner)
ii) 200 mm size( Size may increase as per site condition with best engineering manner)
b) SITC of following size DIDF/CIDF Non Return Valves
i) 150 mm size( Size may increase as per site condition with best engineering manner)
ii)200 mm size( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 200 mm for CWR common header( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
Electrical Item
Supply and laying of 3.5 core 95 Sq.mm. Armoured Aluminum Conductor Cable from TRANSFORMER TO LT Panel with lugs etc. in 02 runs with all material,labour T&P
SITC of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of followint rating:
(i) 315 Amp. Or more as per site requirement
SITC of dust and vermin proof Lt Panel with electrically and mechanically interlocked consisting of 2 Nos incoming Mirco processor based MCCB of 320 Amp( 02 for transformer ) , 06 Nos. outgoing Mirco processor based MCCB of 63 Amp for zone 3& 5 pumping plant, and 04 nos 32 amp and 04 nos 63 amp MCCB microprossor based for Lighting /Spare complete or suitable capacity to operate on 415±10 % volt , 3 phase , 50 Hz, AC supply with power wiring, Ampere meter, Voltmeter ,CT'S, PT, AVF meter, PF meter, Relays and protective device complete in all respect. etc. wiring, CT'S, PT, AVF meter, PF meter, Relays, protective device and have sufficient space for soft starters of pumping plant etc complete in all respect. In cubical type pannel fabricated in compartmentalised (as per instructions of Enginer incharge) from CRC sheet of 2 mm thick for frame work ,2.5 mm thick for cover and 3mm for gland plates with 7 tank process for Powder coating in approved shade
SITC of CE/UL Certified three phase Surge protector for control panel at main switch
SITC of 75 kvar APFC panel suitable for above LT panel with all necessary metering and protective devices complete in all respect.
SITC of CE/UL Certified Radar type Level Transmiter for CWR
Double Plate Earthing of complete Pumping Station (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
SITC of 3Ton capacity hand operated overhead travelling (HOT) crane suitable for span up to 6 mtrs and travelling length upto 10 mtrs with clear lift up to 6 mtrs including gear type chain pulley block and geared travelling trolley complete with all accessories including girder.
10 mm Thickness Electrical resistance sheet
Tools
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type .
Internal & External electrification and lighting (illumination) of pumping station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
Painting of pumping plant and all other E/m equipment with all labour & T& P
Installation, Testing and Commissioning of all above equipments and pumping plants etc complete in all respect.
Tubewell BY D.C./RC Rig Machine (200X150 size) Of Zone 6 (Hamirpur)
Drilling of borehole for Tubewell contruction by RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc.
Transportation, Erection and Dismantling of Rig Machine
Drilling by RC/DC/DTH Rig Machine 500 mm dia with all consumables
0 to 100 mtr. deep (2x100M)
100 to 120 mtr. deep 500 mm dia (2x20M)
Zone Testing in water quality area including Chemical and Bacterological test of water sample from depaprtmental/ approved lab and all required material labour T&P etc complete in all respect (2x3 Job)
Tubewell Assembly for 02 nos Tw's
M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structer etc. As required & as per typed design complete in all respect.
200 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm.
150 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm.
Supply of pea gravel of Size 1.6 to 4.8 mm
Logging of bore hole by departmental /department approved electric logger. (2x1 Job)
Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect.
Shrouding of pea gravel & Lowering of 200mm dia pipe from GL to 54m deep BGL.
Shrouding of Pea gravel & Lowering of 150mm dia pipe from 54 to 100m deep BGL.
Shrouding of Pea Gravel & Lowering of 150mm dia pipe from 100 to 110m deep BGL.
Development of Tubewell by compressor
Transportation, Installation and Dismantling of 250 PSI Compressor (2x1 Job)
Development of Tubewell by Adequate Capacity Air compressor (2x40 Hrs)
Development of Tubewell by O.P. Unit
Transportation, Installation and Dismantling of 1 Cusec O.P. Unit & Yield Test.
Development of Tubewell by Adequate Capacity by O.P. Unit (2x80Hrs)
Chemical and Bacterological test of water sample from depaprtmental/ approved lab.(2x1 Job)
Baricading/ fencing of the site during the construction of T.W. to ensure that site is not exposed to risk of accident. 2x1 Job)
Extra Provision for failed attempts of tubewell construction (Payment only in case lowering completed and abundant by competent authority as per departmental rules )
Zone 6 Tw 1&2
SITC of Submersible pump set with 24m column pipe and suitable size submersible cable NRV,CI D/F Bend 90 ,CI A/F Tee, D/F pipe (1.5 m long 2 nos and 1.0 m long 1 no) Earthing, 03 No Kit Kat mounted on board ,Painting ,Toolset, Power wiring of pump house internal and external, Chain pulley block, and all Pumping plant accessories with nut bolts and rubber packing etc.(All other items for pumping plant item not included in SCADA Automation pumping plant items).
15H.P.or more as per site condition
3 Mtr. long heavy duty size 100mm dia column pipe same as above spare (for 18 mtr length ) (1 set = 02 nos)
Copper cable size 2x3cx4 sq mm. flat for 18 m extra column pipe. (2x36 M)
supply and laying of al cable from transformer to kit kat 3.5 x 25 sq. mm Al. cable with all labour material t&p for 02 nos tw (2x50 M)
SITC of Soft starter including its Pannel with RS-485 port-400V Class 15 Kw rating Or more as per site requirement (2x1 No)
SITC of Servo Stablizer 25 KVA OR more as per site requirement (2x1 No)
SITC of Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) (2x1 No)
SITC of Motor operated actuator with sluice valve upto 150mm Sluice Valve (2x2 No)
SITC of SCADA compacitable Chlorinator Plant (2x1 No)
SITC of CE & UL certified Inteligent Smart Energy Meter (2x1 No)
SITC of CE & UL certified Electro magnatice flow Meter 150mm size (2x1 No)
SITC of CE & UL certified hydro static type sub soil water level transmitter for tubewell. (2x1 No)
SITC of CE & UL certified pressure transmitter (2x1 No)
SITC of CE & UL certified 03 phase Surge protector at main switch (2x1 No)
Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT 2X1 set)
Installation, commissioning & testing for one tubewell / OHT 2x1 Job)
SUB STATION OF INTAKE (315 KVA)
SITC of factory wired dust and vermin proof cubical and floor mounting type control panel comprising of 1 No. incoming V.C.B.(630 Amp) and 2 Nos. outgoing V.C.B. panel with suitable size copper busbar all accessories and protective devices suitable for 315 KVA 2 Nos.11/0.4 KV transformers. In cubical type pannel fabricated in compartmentalised (as per instructions of Enginer incharge) from CRC sheet of 2 mm thick for frame work ,2.5 mm thick for cover and 3mm for gland plates with 7 tank process for Powder coating in approved shade
Supply and laying of 35 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel to transformer. In 02 runwith all material labour T&P
Supply Installation Testing and Commissioning of 315 KVA 11/0.433 KV 50 Hz Copper wound oil cooled Transformer with off load tap changer from +7.5% to -15% LV side @ 2.5 % step vectore group Dy11 as per IS 1180, 2014 Part 1 Level 2 effecient with neccessory saefty devices .
Double Plate Earthing (copper material) of Transformer (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
Installation testing and commissioning of 11 KV/0.4 KV substations including Transformers, HT Panels and L.T. main control panel including all labor T&P complete in all respect.
Supply and making indoor/outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs of 35 sq mm size 3 core XLPE aluminium conductor cable of 11 kv grade.
Provision for routine testing of equipments such as transformer, HT Panels and Main LT Panel at manufacturer’s works.
19 mm Thickness Electrical resistance sheet
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type .
Internal & External electrification and lighting (illumination) of Sub station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
NOC from Electrical safety department for all field installations such as Transformer,pumping plants, substation etc as required for completion of work.
SUB STATION OF WTP + MCWR (400 KVA)
SITC of factory wired dust and vermin proof cubical and floor mounting type control panel comprising of 1 No. incoming V.C.B.(630 Amp) and 2 Nos. outgoing V.C.B. panel with suitable size copper busbar all accessories and protective devices suitable for 400 KVA OR more as per site requirement with best engineering manner 02 Nos.11/0.4 KV transformers. In cubical type pannel fabricated in compartmentalised (as per instructions of Enginer incharge) from CRC sheet of 2 mm thick for frame work ,2.5 mm thick for cover and 3mm for gland plates with 7 tank process for Powder coating in approved shade
Supply and laying of 35 Sq.mm size OR more as per side requirement XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel to transformer. With all material labour T&P
Supply Installation Testing and Commissioning of 400 KVA OR more as per site requirement 11/0.433 KV 50 Hz Copper wound oil cooled Transformer with off load tap changer from +7.5% to -15% LV side @ 2.5 % step vectore group Dy11 as per IS 1180, 2014 Part 1 Level 2 effecient with neccessory saefty devices .
Double Plate Earthing( Copper material) of Transformer (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
Installation testing and commissioning of 11 KV/0.4 KV substations including Transformers, HT Panels and L.T. main control panel including all labor T&P complete in all respect.
Supply and making indoor /outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs of 35 sq mm size 3 core XLPE aluminium conductor cable of 11 kv grade.
Provision for routine testing of equipments such as transformer, HT Panels and Main LT Panel at manufacturer’s works.
19 mm Thickness Electrical resistance sheet
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type .
Internal & External electrification and lighting (illumination) of Sub station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
NOC from Electrical safety department for all field installations such as Transformer,pumping plants, substation etc as required for completion of work.
CWR SUB STATION (160 KVA) (Kaurara)
SITC of factory wired dust and vermin proof cubical and floor mounting type control panel comprising of 1 No. incoming V.C.B.(630 Amp) and 2 Nos. outgoing V.C.B. panel with suitable size copper busbar all accessories and protective devices suitable for 160 KVA 2 Nos.11/0.4 KV transformers. In cubical type pannel fabricated in compartmentalised (as per instructions of Enginer incharge) from CRC sheet of 2 mm thick for frame work ,2.5 mm thick for cover and 3mm for gland plates with 7 tank process for Powder coating in approved shade
Supply and layingof 35 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel to transformer.with all material labour t&p
Supply Installation Testing and Commissioning of 160 KVA 11/0.433 KV 50 Hz Copper wound oil cooled Transformer with off load tap changer from +7.5% to -15% LV side @ 2.5 % step vectore group Dy11 as per IS 1180, 2014 Part 1 Level 2 effecient with neccessory saefty devices .
Double Plate Earthing(copper material) of transformer (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
Installation testing and commissioning of 11 KV/0.4 KV substations including Transformers, HT Panels and L.T. main control panel including all labor T&P complete in all respect.
Supply and making indoor /outdoorcable end termination with heat shrinkable jointing kit complete with all accessories including lugs of 35 sq mm size 3 core XLPE aluminium conductor cable of 11 kv grade.
Provision for routine testing of equipments such as transformer, HT Panels and Main LT Panel at manufacturer’s works.
19 mm Thickness Electrical resistance sheet
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type .
Internal & External electrification and lighting (illumination) of Sub station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
NOC from Electrical safety department for all field installations such as Transformer's ,pumping plants, substation etc for propper completion of works.
SUB STATION OF CCWR (500 KVA)
SITC of factory wired dust and vermin proof cubical and floor mounting type control panel comprising of 1 No. incoming V.C.B.(630 Amp) and 2 Nos. outgoing V.C.B. panel with suitable size copper busbar all accessories and protective devices suitable for 500 KVA 2 Nos.11/0.4 KV transformers. In cubical type pannel fabricated in compartmentalised (as per instructions of Enginer incharge) from CRC sheet of 2 mm thick for frame work ,2.5 mm thick for cover and 3mm for gland plates with 7 tank process for Powder coating in approved shade
Supply AND LAYING of 35 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel to transformer.with material labour T&P
Supply Installation Testing and Commissioning of 500 KVA 11/0.433 KV 50 Hz Copper wound oil cooled Transformer with off load tap changer from +7.5% to -15% LV side @ 2.5 % step vectore group Dy11 as per IS 1180, 2014 Part 1 Level 2 effecient with neccessory saefty devices .
Double Plate Earthing (copper material) of transformer (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
Installation testing and commissioning of 11 KV/0.4 KV substations including Transformers, HT Panels and L.T. main control panel including all labor T&P complete in all respect.
Supply and making indoor /ourdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs of 35 sq mm size 3 core XLPE aluminium conductor cable of 11 kv grade.
Provision for routine testing of equipments such as transformer, HT Panels and Main LT Panel at manufacturer’s works.
19 mm Thickness Electrical resistance sheet
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type .
Internal & External electrification and lighting (illumination) of Sub station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
NOC from Electrical safety department for all field installations such as Transformer,pumping plants, substation etc as required for completion of work.
CWR SUB STATION (160 KVA)
SITC of factory wired dust and vermin proof cubical and floor mounting type control panel comprising of 1 No. incoming V.C.B.(630 Amp) and 2 Nos. outgoing V.C.B. panel with suitable size copper busbar all accessories and protective devices suitable for 160 KVA 2 Nos.11/0.4 KV transformers. In cubical type pannel fabricated in compartmentalised (as per instructions of Enginer incharge) from CRC sheet of 2 mm thick for frame work ,2.5 mm thick for cover and 3mm for gland plates with 7 tank process for Powder coating in approved shade
Supply and layingof 35 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel to transformer with all material labour ,T&P.
Supply Installation Testing and Commissioning of 160 KVA 11/0.433 KV 50 Hz Copper wound oil cooled Transformer with off load tap changer from +7.5% to -15% LV side @ 2.5 % step vectore group Dy11 as per IS 1180, 2014 Part 1 Level 2 effecient with neccessory saefty devices .
Double Plate Earthing (copper material) of transformer (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
Installation testing and commissioning of 11 KV/0.4 KV substations including Transformers, HT Panels and L.T. main control panel including all labor T&P complete in all respect.
Supply and making indoor /outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs of 35 sq mm size 3 core XLPE aluminium conductor cable of 11 kv grade.
Provision for routine testing of equipments such as transformer, HT Panels and Main LT Panel at manufacturer’s works.
19 mm Thickness Electrical resistance sheet
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type .
Internal & External electrification and lighting (illumination) of Sub station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
NOC from Electrical safety department for all field installations such as Transformer's ,pumping plants, substation etc for propper completion of works.
Automation of Intake Well,MCWR,CWR(Kaurara),CCWR &CWR Z3&5
For Intake Well
SITC of CE & UL Certified PLC/RTU with redundantCPU & Power supplyin IP 54 enclose suitable to Communicate with GSM based modem unit with redundant CPU & Power supply with annlog & digital parameter & featuers as specified, for each Intakewell to store and transmit data on GSM backbone, RTU/PLC desgined with logic to transfer data at multiple stations with control panel as specified in tender technical specifications.
SITC of G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories include with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification .
SITC of Intelligent energy meters
SITC of Control Panel with IP 54 Protection, Industrial Grade for all equipment. (Separate for control (24 V) and power equipments.) upto 3 pumps.
SITC of CE/ UL Certified 7" HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters.
Cabling
Complete Cabling for Intake well including all power & control cable of all equipments .
SITC of Security Survelliance IP Camera with recorder
Automation of TW
SCADA Automation Items
SITC of CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations
SITC of G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges
CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter.
SITC of Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments)
Trial run for 03 months period for one tubewell through SCADA
E/M WORKS ON OHT TANK
SITC of Motor operated actuator with sluice valve on OHT of 250 mm size of Zone 3 (Kaurara) and Zone 6 of Hamirpur.
SITC of Flow Meter on OHT delivery line of size 250 mm dia of Zone 1(Kaurara) &Zone 6 of hamirpur.
SITC of Motor operated actuator with sluice valve on OHT of 300 mm size of Zone 1&2 (Kaurara)
Flow Meter on OHT delivery line of size 250 mm dia of Zone 1 &2 (Kaurara)
SITC of Motor operated actuator with sluice valve on OHT of 350 mm size of Zone 2,3&5.
SITC of Flow Meter on OHT delivery line of size 350 mm dia of Zone 2,3&5.
SITC of Motor operated actuator with sluice valve on OHT of 400 mm size of Zone 1 &4 of Hamirpur.
SITC of Flow Meter on OHT delivery line of size 400 mm dia of Zone 1 &4 of Hamirpur.
SITC of CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations ( Payment only for each stand alone OHT OR As per instructions of Engineer Incharge)
SITC of G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant with internet charges ( Payment only for each stand alone OHT OR As per instructions of Engineer Incharge)
SITC of Chlorine Analyzer rnge 0-5 ppm (electrolyte with membrane cap; Type- Amperometric.
SITC of CE/UL certified Radar type Level Transmitter for Over haead Tank for OHT
Master Control Station (MCS)
SCADA DISPLAY
SITC of CE/UL & BIS Certified industrial grade LED MONITOR with latest configrutation as per specification
Desktop/PC with i7 processor for as per specification mentioned in technical bid documents.
SITC of CE/UL Certified 5KVA UPS with batteries as per specification mentioned in technical bid document.
Full development version of required TAGS SCADA Software with coustomisation of software for MCS as per requirement
SITC of CE/UL Certified master control room PLC with redundant CPU & power supply at MCS in IP54 - enclouser as spec mentioned in technical bid documents.
SITC of CE/UL Certified Field gateway agent for transfering data from MCS to Central control room.
SITC of GSM based wireless /Broadband/Equipment communication system for PLC capable to transfer & received data & gather dat from remote sites to control station,All accessories included signal enhancer antenna along with running expenses till DLP.
SITC of CE/UL Certified Firewall for network protection.
SITC of SURGE PROTECTOR FOR ETHERNET Communication protection.
SITC of CE/UL certified industrial grade Ethernet Switch.
Mobile App Facility system architecture(Industries internet based & viewed through mobile apps for increased local & Remote Visibility).
Canon/HP or equivalent Laser Printer 1018 or equivement.
Security Surveillance IP camera with recorder (optional)
Installation, Commissioning & testing including required furniture AC etc.
Trial run for 3 month period for MCS
Trial and Run for whole E&M equipment including gaseous chlorine, PAC and 1 No. supervisior, 1 no. electrician, 1 no. fitter/helper, 2 no. watchman and 3 no. SCADA Operaor each month for 3 months
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.61 MB
HamirpurkuraraTD.pdf
Tender Documents • 12.73 MB
BOQ_2049461.xls
BOQ • 1.16 MB
Download all tender documents and submit your bid