Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹35.1 LAccepted-AOC WZ 1391 31 B NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹35.1 L Quoted ₹36.6 L | 1 | Accepted-AOC accepted amt |
| 2 | 2₹38.9 L+₹2.3 L (6.36%)Rejected-Finance MOHANPURA MAHAMMADPUR SOUTH CIVIL LINES PO MILAP NAGAR ROORKEE 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | ₹38.9 L+₹2.3 L (6.36%) | 2 | Rejected-Finance other than L1 bid |
| 3 | 3₹39.4 L+₹2.9 L (7.87%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹39.4 L+₹2.9 L (7.87%) | 3 | Rejected-Finance other than L1 bid |
| 4 | 4₹40.0 L+₹3.4 L (9.35%)Rejected-Finance VILLAGE POST KORUWA CHAKRATA DEHRADUN | DEHRADUN | DEHRADUN | UTTARAKHAND | ₹40.0 L+₹3.4 L (9.35%) | 4 | Rejected-Finance other than L1 bid |
| 5 | 5₹41.1 L+₹4.6 L (12.5%)Rejected-Finance FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹41.1 L+₹4.6 L (12.5%) | 5 | Rejected-Finance other than L1 bid |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
4 Oct 2023, 6:00 pmClosed
GE P DDN
GE P DDN
REPAIR/MAINT OF EXTERNAL WATER SUPPLY LINE FROM JADDI LINE KANDHAR LINE IN CHAKRATA AT AGE B/R (P) CHAKRATA UNDER GE (P) DEHRADUN
2023_MES_616499_1
GE P/ DDN/T-33 OF 23-24
Open Tender
Civil Works
Item Rate
180 days
Chakrata
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE P DDN
₹90,000
Yes
1 Dec 2023
31 Aug 2023
6 Oct 2023
31 Aug 2023
4 Oct 2023
14 Sept 2023
Amount
Supply and Laying Pipes galvanized, “Medium class”, supplied and laid complete including fittings 100 mm dia, complete all as specified and directed.
Supply and Laying Pipes galvanized, “Medium class”, supplied and laid complete including fittings 150 mm dia complete all as specified and directed.
Supply and Laying Pipes galvanized, “Medium class”, supplied and laid complete including fittings 80 mm dia complete all as specified and directed.
Supply and Laying Pipes galvanized, “Medium class”, supplied and laid complete including fittings 50 mm dia complete all as specified and directed.
Supply and Laying Pipes galvanized, “Medium class”, supplied and laid complete including fittings 25 mm dia complete all as specified and directed.
Supply and Laying Pipes galvanized, “Medium class”, supplied and laid complete including fittings 20 mm dia complete all as specified and directed.
Supply and fix in replacement of flanged type Sluice valve hand wheel operated CI Body with SS spindle PN-1.6 rating, with nut bolts and washer of suitable size as per IS-14846 / as per existing site including taking down complete all as specified and directed. of following sizes:- (a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
Supply and Fix Valve, stop, screwed, supplied and installed complete for size 50 mm dia pipe complete all as specified and directed.
Supply and Fix Valve, stop, screwed, supplied and installed complete for size 25 mm dia pipe complete all as specified and directed.
S&F in repair 20 mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete, all as specified & directed.
S&F in repair 25 mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete, all as specified & directed.
S&F in repair 50 mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete, all as specified & directed.
Electrically driven horizontal end Suction, centrifugal type confirming to IS- 12469 :1988 with CI Casing , bronze impeller and Stainless steel shaft mounted on heavy duty bearings Suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 230 V , 3 Phase. 50 Hz capacity 1 HP.
Electrically driven horizontal end Suction, centrifugal type confirming to IS- 12469 :1988 with CI Casing , bronze impeller and Stainless steel shaft mounted on heavy duty bearings Suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 230 V , 3 Phase. 50 Hz capacity 0.75 HP.
M & L for CI/DI fitting for spigot & socket end pipes such as Bends (any type, radius and angle), up to 150 mm bore all as specified and directed.
M & L for drilling and tapping water mains in position for making branch connections complete all as specified and directed.
S&F in 1000 Litre Double Black Water Tank, CCWS - 2500.1 complete, all as specified & directed.
M&L for Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for laying of underground cable, foundation of pole and getting out in soft/loose soil complete all as specified and directed.
M&L for Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
M&L for Removing of excavated soil to a distance n. exc. 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for PCC for mass concreting in bends, pathways, socket etc type C-2 (1:3:6) complete all as specified & directed.
M&L for PCC for mass concreting in bends, pathways, socket etc type 1:3:6 complete all as specified & directed.
M & L for Plain Cement concrete 1 : 4 : 8 type D2 using 40 mm graded stone aggregate for water Tank foundation, filling and mass concrete all as specified.
M & L for Plain cement concrete 1:2:4 type B1 using 20mm graded aggregate for coping to pole foundation including necessary form work with fair finished surface all as directed.
Supply of stable bleaching powder Grade – I conforming to IS-1065/1989 (IInd Revision) as amended up to date having available chlorine contents minimum 34% by mass and packed in 25 Kg polythene bag having double fold complete all as specified and directed and as per following specifications:- Bleaching powder (Calcium Hypo Chloride), Chlorine formula : Ca (OCl)2 Molecular weight : 142.96, Physical Appearance : white fine powder, Chlorine content :- 30 % ± 1%, Moisture : 0.5 % Max On heating at 10 ± 2°C it dose not lose more than 1/15 of available chlorine Passing through 1.7mm sieve : 99%
Supply of Alum Ferric Sulphate (Grade-4) (best quality as per sample) for purification of water (containing lead (as PB) 30 ppm max and arsenic 6ppm max) confirming to IS-299/2012 (Revised) as amended up-to-date complete all as specified and directed and as per IS specifications.
M&L for Brick masonry valve pit of size 600mmx 600mmx 600mm internal dimensions of the chamber including brick masonry with cement mortar 1.6 and flush pointing externally as the work proceeds 23 cm thick wall complete with the following specification and as directed. (i) 10mm thick plaster in CM 1:6 internally. (ii) PCC (1:3:6) type C-2 100 mm thick in foundation. (iii) Flooring 40mm thick in PCC (1:2:4) type B1, over 75mm thick hard core of gauge exc 63mm. (iii) Angle iron frame 40X40X6mm thick and cover of mild steel 3mm thick sheet double door type minimum one side continuation hinges on each side. (iv) Two coats of synthetic enamel paint to cover internally and externally over a coat of red oxide primmer.
M&L for Brick masonry valve pit of size 1050mmx 1050mmx 1050mm internal dimensions of the chamber including brick masonry with cement mortar 1.6 and flush pointing externally as the work proceeds 23 cm thick wall complete with the following specification and as directed. (i) 10mm thick plaster in CM 1:6 internally. (ii) PCC (1:3:6) type C-2 100 mm thick in foundation. (iii) Flooring 40mm thick in PCC (1:2:4) type B1, over 75mm thick hard core of gauge exc 63mm. (iii) Angle iron frame 40X40X6mm thick and cover of mild steel 3mm thick sheet double door type minimum one side continuation hinges on each side. (iv) Two coats of synthetic enamel paint to cover internally and externally over a coat of red oxide primmer.
M&L for Brick masonry valve pit of size 750mmx 750mmx 750mm internal dimensions of the chamber including brick masonry with cement mortar 1.6 and flush pointing externally as the work proceeds 23 cm thick wall complete with the following specification and as directed. (i) 10mm thick plaster in CM 1:6 internally. (ii) PCC (1:3:6) type C-2 100 mm thick in foundation. (iii) Flooring 40mm thick in PCC (1:2:4) type B1, over 75mm thick hard core of gauge exc 63mm. (iii) Angle iron frame 40X40X6mm thick and cover of mild steel 3mm thick sheet double door type minimum one side continuation hinges on each side. (iv) Two coats of synthetic enamel paint to cover internally and externally over a coat of red oxide primmer.
A ONE BUILDERS AND ENGINEERS
P S TRADERS
J P CONSTRUCTION
Ansh Enterprises
PAWAN KUMAR
BARAF SINGH CHAUHAN
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .