Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹12.3 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹12.4 L+₹424.76 (0.03%)Admitted-Finance | L2 | Admitted-Finance |
Tender Value
₹14.2 L
EMD Value
₹28,400
Closing Date
25 May 2026, 6:00 pmClosed
EXECUTIVE ENGINEER
KDA KOTA
Providing and Installation of air conditioners in various offices and sections of Kota Development Authority
2026_UITKo_560617_1
03/2026-27 (21)
Open Tender
Electrical Works
Percentage
30 days
KOTA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
Online Through SSO Portal
₹28,400
Yes
26 May 2026
19 May 2026
26 May 2026
19 May 2026
25 May 2026
19 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, installation, testing and comissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | |||||
| 1.1 | 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) | 92 | Mtr. | 728 | ₹66,976 |
| 1.2 | 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) | 92 | Mtr. | 383 | ₹35,236 |
| 2Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | |||||
| 2.1 | 20 mm | 65 | Mtr. | 189 | ₹12,285 |
| 3 | Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | 18 | Each | 580 | ₹10,440 |
| 4 | Dismentling of split air conditioner of any capacity/any type including existing indoor unit & outdoor unit , refrigerant piping , connecting cables , drain pipe etc. including shifting of dismentaled material to store complete as required | 5 | Job | 936 | ₹4,680 |
| 5Supply , Installation, Testing and Comissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | |||||
| 5.1 | 1.5 TR ISEER not less then 3.8 | 16 | Each | 48,875 | ₹7,82,000 |
| 5.2 | 2.0 TR ISEER not less then 3.8 | 6 | Each | 63,731 | ₹3,82,386 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.73 MB
CONDITIONS_E_03_21.pdf
Tender Documents • 0.47 MB
BOQ_997857.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .