Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAdmitted-Finance MALBASSA WEST DALAK AMARPUR GOMATI TRIPURA 799104 | GOMATI | TRIPURA | 799104 | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SAJAL DAS L1 |
|---|---|---|---|---|
| 1.00SCHEDULE - A | ||||
| 2.00 | Supply of febricated clamps of assorted size of MS flat ( 50X 6 MM ) with double coat of red Oxide primer coating | 20 | No. | 80 ₹1,888 Lowest |
| 3.00 | Supply of M.S Nuts & Bolts i/c Washer of assorted size ISI Marked machine made. | 40 | No | 15 ₹708 Lowest |
| 4.00 | Design, engineering, Manufacturing, Supply, installation & Pre-Commissioning testing at site by Manufacturer Engineers of 11KV, 1250Amps, 25KA for 3sec, 350 MVA rupturing capacity Indoor Vaccum Circuit Breaker for outgoing feeder complete with 1Set of CT of ratio 300/1-1Control & Relay Pannel Simplex type with 110 Volt DC actuated electrical closing/ tripping mechanism and internal wiring 2-Over current & 1-earth fault combined Micom digital nos electromechanical relay, 1 AREVA masterTrip Relay, Auxiliary relays as required, 1 Nos L&T / SECURE make (Tri-Vector) Meter (SCADA compatible with communication facility), 3-Ammeter, 1-Volt Meter, 1-CT operated Static KW Meter, with pannel Bus mounted CT & integral earthing facility in/c internal arc tested pannel conforming to relevant ISS/IEC as required in/c standard indication facilities as per requirement detailed in the bid documents. | 1 | No | 5,30,000 ₹6,25,400 Lowest |
| 5.00 | Erection of 9 mtrs. length of Galvanised Steel Tubular Pole at any kind of soil upto a depth of 1/6th of pole height including excavation of earth refilling the pit with soil upto the ground level rammng and making complete in all respect. | 4 | Each | 300 ₹1,416 Lowest |
| 6.00 | Erection of Galvanised Channel Cross-Arm. 100x50x50x6 mm ( 0.6 to 2.8mtr long ) for S/S bkt. | 4 | No. | 10 ₹47.2 Lowest |
| 7.00 | Erection of Galvanised Channel 75x40x40x6 mm mm. for GOS, DOF, Line bkt,Tapping (1.3 to 2.8 mtr long ) | 8 | No. | 10 ₹94.4 Lowest |
| 8.00 | Erection of Galvanised Angle 65x65x6 mm for Guard Bkt ( 1.0 to 2.5 mtr long ) | 8 | No. | 10 ₹94.4 Lowest |
| 9.00 | Erection of 11 KV 200 Amp GOS unit set of 3 nos including necessary connection complete as per technical specification (Excluding the cost of back clamp, Nuts & Bolts). | 3 | Set | 500 ₹1,770 Lowest |
| 10.00 | Erection of 11 KV Single Disc insulator set along with necessary fittings | 12 | No | 5 ₹70.8 Lowest |
Tender Value
₹6.9 L
EMD Value
₹13,719
Closing Date
25 Sept 2026, 5:00 pmClosed
DGM, ED-Jirania, TSECL
O/o the DGM, ED-Jirania, TSECL
Extension of 11 KV new dedicated Feeder by UG cable from Khayerpur 33 /11 KV Sub-Station Breaker to Busbar for feeding power to Balaji Parking ( Royal Industries ) at Old Agartala under ESD-Khayerpur
2026_POWER_76974_1
DGM/ED-JRN/2026-27/06
Open Tender
Electrical Works
Turn-key
90 days
within the jurisdiction of ESD Khayerpur
As per BID Document
3 documents required · 3 mandatory
₹2,500
₹13,719
O/o the DGM, ED-Jirania, TSECL
9 Oct 2026
18 Sept 2026
28 Sept 2026
18 Sept 2026
25 Sept 2026
19 Sept 2026
18 Sept 2026 - 19 Sept 2026
19 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SCHEDULE - A | - | - | - | - |
| 2 | Supply of febricated clamps of assorted size of MS flat ( 50X 6 MM ) with double coat of red Oxide primer coating | 20 | No. | - | - |
| 3 | Supply of M.S Nuts & Bolts i/c Washer of assorted size ISI Marked machine made. | 40 | No | - | - |
| 4 | Design, engineering, Manufacturing, Supply, installation & Pre-Commissioning testing at site by Manufacturer Engineers of 11KV, 1250Amps, 25KA for 3sec, 350 MVA rupturing capacity Indoor Vaccum Circuit Breaker for outgoing feeder complete with 1Set of CT of ratio 300/1-1Control & Relay Pannel Simplex type with 110 Volt DC actuated electrical closing/ tripping mechanism and internal wiring 2-Over current & 1-earth fault combined Micom digital nos electromechanical relay, 1 AREVA masterTrip Relay, Auxiliary relays as required, 1 Nos L&T / SECURE make (Tri-Vector) Meter (SCADA compatible with communication facility), 3-Ammeter, 1-Volt Meter, 1-CT operated Static KW Meter, with pannel Bus mounted CT & integral earthing facility in/c internal arc tested pannel conforming to relevant ISS/IEC as required in/c standard indication facilities as per requirement detailed in the bid documents. | 1 | No | - | - |
| 5 | Erection of 9 mtrs. length of Galvanised Steel Tubular Pole at any kind of soil upto a depth of 1/6th of pole height including excavation of earth refilling the pit with soil upto the ground level rammng and making complete in all respect. | 4 | Each | - | - |
| 6 | Erection of Galvanised Channel Cross-Arm. 100x50x50x6 mm ( 0.6 to 2.8mtr long ) for S/S bkt. | 4 | No. | - | - |
| 7 | Erection of Galvanised Channel 75x40x40x6 mm mm. for GOS, DOF, Line bkt,Tapping (1.3 to 2.8 mtr long ) | 8 | No. | - | - |
| 8 | Erection of Galvanised Angle 65x65x6 mm for Guard Bkt ( 1.0 to 2.5 mtr long ) | 8 | No. | - | - |
| 9 | Erection of 11 KV 200 Amp GOS unit set of 3 nos including necessary connection complete as per technical specification (Excluding the cost of back clamp, Nuts & Bolts). | 3 | Set | - | - |
| 10 | Erection of 11 KV Single Disc insulator set along with necessary fittings | 12 | No | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.96 MB
Tendernotice_2.pdf
PDF • 2.00 MB
BIDDOCUMENT.pdf
Tender Documents • 1.98 MB
BOQ_78355.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .