| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.5 CrAdmitted-Finance 1ST FLOOR SAI COMPLEX BESIDES ADITYA VIP ENCLAVE NEAR GANESH MANDAP CHHAK JHARPADA BHUBANEWAR 751006 | KHORDHA | ODISHA | 751006 | -25.01% | ₹1.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.7 CrAdmitted-Finance AT NAYAK SAHI PO DEVIDWAR JAJPUR TOWN ODISHA 755007 | BHADRAK | ODISHA | 755007 | -15.35% | ₹1.7 Cr | L2 | Admitted-Finance |
| 3 | L3₹1.7 CrAdmitted-Finance 1ST FLOOR PARAMA PARASA AT CHANDESWAR PO DEBIDWAR JAJPUR 755007 | BHADRAK | ODISHA | 755007 | -13.60% | ₹1.7 Cr | L3 | Admitted-Finance |
| 4 | L4₹2.0 CrAdmitted-Finance AT CUTTACK ODISHA | +0.00% | ₹2.0 Cr | L4 | Admitted-Finance |
| 5 | L4₹2.0 CrAdmitted-Finance KHORDHA ODISHA 751003 INDIA UDYAM OD 19 0012505 | KHORDHA | ODISHA | 751003 | +0.00% | ₹2.0 Cr | L4 | Admitted-Finance |
Tender Value
₹2.0 Cr
EMD Value
₹2.0 L
Closing Date
12 May 2026, 5:00 pmClosed
S.E. Electrical Circle (RandB) Bhubaneswar
S.E. Electrical Circle (RandB) Bhubaneswar, Nirman Soudha, Unit-V, 751001.
Provision of Conventional Street Light for PWD Road from Jamunalia to Mandua on NH 215 from Jamunalia to Dhrupada (Bypass Portion) from Ch.0/000 Km to Ch.5/500 under DMF for the year 2025-26
2026_EICCL_128492_4
Bid Identification No.S.E.E.C (RandB) 05/2026-27
National Competitive Bid
Electrical Works
180 days
Keonjhar
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹2.0 L
12 Jun 2026
27 Apr 2026
13 May 2026
27 Apr 2026
12 May 2026
27 Apr 2026
27 Apr 2026 - 4 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Supply of 11 mtr high PU Painted octagonal galvanised GI steet light pole with made out from 3mm thick steel sheet (grade of steel S-355) Top dia 90mm & Bottom dia 210 mm single sharp welding with base plate dimension 300x300x16 mm, 4 nos. of M24X750 long 'J' type EN 8 grade foundation Bolts,PCD 300mm. and wind speed of 180 km/hr.The door opening of the pole should be reinforced,water proofed & with locking arrangement hinged type (special for theft control) &Supply of junction box with 1nos 6Amp SP MCB & terminal box with provision for connection of earth & nutral on 5mm thick fiber plate which will be kept in side the pole for termination of cable & wire. .Provision should be made for fixing of junction box inside the pole door copmpartment,4nos foundation bolts (galvanised)should be supplied with pole. (galvanization of the pole is as per BSEN ISO 1461 & minimum galvanization thickness is 75micron) (To be given on one side only with approximate spacing of 30 mtr)(Make-RR Ispat /BAJAJ/Valmont/Utkarsh/Vakrangee/Transrail )
NB: The structural design of the pole foundation shall be approved by concerned civil wing( SE, Keonjhar (R&B) Division)/competant authority. | 201 | Nos | 30,886 | ₹62,08,086 | BI01010001010000000000000515BI0100001152 |
| 2 | Supply and fixing of PU Painted GI decorative double tappered single arm 2000mm bracket with decorative FRP canopy & Frp decorative knobs, the arm design should reflect heritage of Keonjhar as per the direction of Engineer-in-charge. The contractor should submit various combinations of Arm & Pole design to the Engineer-in-Charge after award of contract and before procurement for approval. | 201 | nos. | 4,063 | ₹8,16,663 | BI01010001010000000000000515BI0100001153 |
| 3 | Supply of LED Design based BIS approved LED Street Light with system power of 220W, CCT in 5700K as per ANSI) ,CRI>70, SDCM<3 , LEDs used should have a life of 50,000 burning hrs. & Lumen maintenance as per L70. The Luminaire System lumens should be >34100 Lumens @5700K. The fixture housing must be Made of ADC 12 PDC Aluminium housing for rapid thermal healing & Powder coated by Corrosion resistant Nano coating technology. Luminaire must have a Ingress protection of IP66 and Impact Resistance of IK08. The light engine should use Metal Core PCB with high grade aluminium (AL5052) and should have a thermal conductivity of >2W/mK. The fixture should have an UV stabilized Injection moulded special PC lens optics(Glass not allowed) ensuring low glare & best in class uniformity. The light engine and the driver compartment should be thermally isolated by a natural airgap. Luminaire housing and optical compartment both should carry OEM's logo embossed / engraved (no stickering is allowed). The luminaire must have Integral encapsulated high efficiency electronic thermally isolated driver having a Aluminium extrusion construction with rated voltage of 100-300V, power factor > 0.95, THD < 10%, with Inbuilt surge protection of min 6KV and upgraded with integrated IP67 protected SPD of 20KV/10KA surge protection with all necessary safety protection like mis-wiring, Over voltage, Short circuit, Reverse Polarity protection. . The compartment should be bottom openable for ease of maintenance at site. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015. Following documents to be submitted after award of contract: Luminaire and Driver TDS, Photometry report, Type test certificate, IP, IK, Vibration and salt spray test certificates from NABL accredited Laboratory, LM80 from LED OEM., CE Certification, ROHS compliant, BIS Certificate for Luminaires & Drivers. The warranty on light fixture shall be 5 years. (Make: PHILIPS/WIPRO/BAJAJ/Crompton/PANASONIC/LT/HAVELLS)
NB: LM79 reports of the light fixture from third party/central/state govt accredited NABL lab is to be submitted and duly approved from SE(Electrical circle) R&B. Alongwith the above said reports, the LUX design report, LUX level design for road carraigeway to be done as per following specifications: average lighting level shall be >=41 LUX , Uniformity >=0.6 , Maintenance factor of 0.85 to be considered, LUX level design for pedestrian side-1 to be done as per following specifications: average lighting level shall be >=25 LUX , Uniformity >=0.6 , Maintenance factor of 0.85 to be considered, LUX level design for pedestrian side-2 to be done as per following specifications: average lighting level shall be >=36 LUX , Uniformity >=0.6 , Maintenance factor of 0.85 to be considered, the lighting level should be uniform and there should be no dark patches. Accordingly, the optics of luminaire and pole should be designed ,Technical data sheet of light are also to be submitted for approval from SE(Electrical circle) R&B. After supply of material, a random sample will be chosen and will be sent to Govt. NABL approved lab for destructive test for verification of genuinity of all the reports.If the product does not comply with the reports submitted, the whole lot will be rejected.Cost of the testing shall be borne by the contractor. | 201 | Nos | 23,125 | ₹46,48,125 | BI01010001010000000000000515BI0100001154 |
| 4 | Supply of 1.1 KV, AYFY 4C x 16sqmm Aluminium Armoured XLPE Cable through clamping /HDPE pipe in complete as per the direction of Engineer-in-charge. Make-Havells/KEI/Finolex/Polycab/Gloster/RR Kabel | 6,732 | MTR | 305 | ₹20,53,260 | BI01010001010000000000000515BI0100001155 |
| 5 | Supply and laying of 63mm HDPE PN16 pipe at a depth of 1m (underground) required for cable laying in complete as per the direction of Engineer-in-charge. | 6,732 | MTR | 90 | ₹6,05,880 | BI01010001010000000000000515BI0100001156 |
| 6 | supply and laying of class-C GI pipe 100mm dia (required for road crossing of main cable) in complete as per the direction of Engineer-in-charge. | 200 | MTR | 2,700 | ₹5,40,000 | BI01010001010000000000000515BI0100001157 |
| 7 | Supply of 1.1 KV, AYFY 3.5C x 35 sqmm Aluminium Armoured XLPE Cable through cable trench/HDPE pipe in complete as per the direction of Engineer-in-charge. Make-Havells/KEI/Finolex/Polycab/Gloster/RR Kabel (transformer to control feeder pillar) | 600 | MTR | 425 | ₹2,55,000 | BI01010001010000000000000515BI0100001158 |
| 8 | Foundation & erection of 11mtr long street light pole and the foundation drawing is to be designed so as to sustain wind speed of 180km/hr and the same shall be duly approved by SE(R&B) Division, Keonjhar. | 201 | Nos | 11,500 | ₹23,11,500 | BI01010001010000000000000515BI0100001159 |
| 9 | Wiring of make 3 core 1.50 mm2 round flexible copper cable from junction box to light fitting in complete as per the direction of Engineer-in-charge. Make-Havells/KEI/Finolex/Polycab/Gloster/RR Kabel | 3,107 | MTR | 95 | ₹2,95,165 | BI01010001010000000000000515BI0100001160 |
| 10 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground in the existing RCC/HUME/STONEWARE/METAL pipe as required. | 6,732 | MTR | 58 | ₹3,90,456 | BI01010001010000000000000515BI0100001161 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.44 MB
DTCN.pdf
Tender Documents • 1.95 MB
BOQ_588838.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid