Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹13.1 L+₹2.7 L (25.9%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹14.0 L+₹3.6 L (34.2%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
10 May 2025, 6:00 pmClosed
GE SAMBA
GE SAMBA PIN 184121
REPAIRS AND MAINT TO DESERT COOLERS AIR CONDITIONERS AND REFRIGERATORS LAUNDRY PLANT AND CONNECTED ACCESSORIES OF ALL UNITS UNDER GE SAMBA
2025_MES_703969_1
GE/SMB/T-02/2025-26
Open Tender
Miscellaneous Works
Item Rate
180 days
GE SAMBA
CLASS E CATEGORY b i
8 documents required · 8 mandatory
₹500
GE SAMBA
₹40,000
Yes
2 Jul 2025
9 Apr 2025
12 May 2025
9 Apr 2025
10 May 2025
23 Apr 2025
Amount
Opening up of existing water cooler for Inspection by MES rep to ascertain due repair/replacement , of any size any type, at the site/ fixed in position and incl cleaning the tank, and testing after required repair /replacement including making necessary connection to the power point complete all as specified and directed. Notes (i) Repair / Replacement of old defective spare parts/ items shall be measured and paid separately under respective items.if orederd by MES Rep (ii) Cost of transportation of water cooler/ spare parts of water cooler required being repair/replaced, from site to workshop for repair and workshop to site after repair shall be deemed to be included in quoted rates of respective item
M and L for Replacement of old unserviceable/ damaged hermatic sealed unit(Compressor) with new hermatic sealed unit, for water cooler of 40 liters capacity, complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged hermatic sealed unit (Compressor)with new hematic sealed unit, for water cooler of 80 liters capacity, complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged hermatic sealed unit (Compressor)with new hermatic sealed unit, for water cooler of 120 liters capacity, complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged hermatic sealed unit with new hermatic sealed unit (Compressor), for water cooler of 150 liters capacity, complete all as specified and directed.
M and L for Replacement/ filling of refrigerant gas (R-134a), suitable for water cooler of up to 80 liters capacity including testing against any leakage, complete all as specified and directed.
All as per serial item No-6 above but for water cooler of 120 liters capacity.
All as per serial item No-6 above but for water cooler of 150 liters capacity.
M & L for Replacement of old unserviceable condensing coil of water cooler for 40 to 150 lts of capacity complete all as specified and directed
M and L for Replacement of old unserviceable/ damaged starting relay with new starting relay for water cooler of 40, 60 120 and 150 liters capacity, complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged over load protection relay with new over load protection relay for water cooler of any capacity, complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged starting condenser with new starting condenser of 40-60mfd, for water cooler, complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged starting condenser with new starting condenser of 60-80mfd for water cooler, complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged starting condenser with new starting condenser of 80-100mfd for water cooler, complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged starting condenser with new starting condenser of 100-120mfd for water cooler, complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged running condenser with new running condenser of water cooler 10mfd, complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged running condenser with new running condenser of water cooler 25mfd complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged running condenser with new running condenser of water cooler 36mfd complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged thermostat of any size for water cooler complete all as specified and directed.
M and L for Replacement of fan motor 1/35 HP for water coolers any capacity complete all as specified and directed.
M and L for Replacement of fan motor 1/10 HP for water coolers any capacity complete all as specified and directed
M and L for Replacement old damaged/ unserviceable PVC hose pipe with new PVC hose pipe, suitable for water cooler of any type and any capacity, complete all as specified and directed
M and L for Replacement old damaged/ unserviceable push cock with new push cock, chromium plated, for 15mm bore pipe, suitable for water cooler of any type and any capacity, complete all as specified and directed
M and L for Replacement of old unserviceable/ damaged ball valve with new ball brass valves, high pressure, with polythene float and flynut, screwed for iron pipe or brass ferrule and fixed for 15mm bore pipe, complete all as specified and directed
Opening up of existing Refrigerator for Inspection by MES rep to ascertain due repair/replacement , of any size any type, at the site/ fixed in position and incl cleaning tinside and outside , and testing after required repair /replacement including making necessary connection to the power point complete all as specified and directed. Notes (i) Repair / Replacement of old defective spare parts/ items shall be measured and paid separately under respective items.if orederd by MES Rep (ii) Cost of transportation of water cooler/ spare parts of water cooler required being repair/replaced, from site to workshop for repair and workshop to site after repair shall be deemed to be included in quoted rates of respective item
M & L for Replacement of old unserviceable/ damaged hermetic sealed unit with new hermatic sealed unit of 1/8 HP (Compressor), for refrigerator of 165-175 liters and 180-200 liters capacity, complete all as specified and directed.
M & L for Replacement of old unserviceable/ damaged hermetic sealed unit with new hermatic sealed unit of 1/6 HP (Compressor), for refrigerator of 210-320 liters capacity, complete all as specified and directed.
M and L for Replacement/ filling of refrigerant gas (R-134a), suitable for refrigerator of 165-175 litres capacity including testing against any leakage, complete all as specified and directed.
M and L for Replacement/ filling of refrigerant gas (R-134a), suitable for refrigerator of 210-320 litres capacity including testing against any leakage, complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged over load protection relay with new over load protection relay, 1/8 HP for refrigerator of 165 to 320 liters capacity, complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged starting relay with new starting relay for refrigerator of 1/8 HP and 1/6 HP, complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged thermostate with new thermostate for refrigerator of any size and any descriptions, complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged freezer door with new freezer door including proper insulation and rubber seal, for refrigerator of 165/175 liters capacity, complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged freezer door with new freezer door including proper insulation and rubber seal, for refrigerator of 210/320 liters capacity, complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged PCB with new PCB for refrigerator of any capacity and any description, complete all as specified and directed.
M and L for Replacement of old unserviceable evaporator of referigerator of any capacity complete all as specified and directed
M and L for Replacement of old unserviceable condensing coil of referigerator of any capacity complete all as specified and directed
Rewinding for desert cooler motor with super enameled copper winding wire of same guage and weight including varnishing and heating, inter connection etc complete all as directed ( Cooler of iron body , standard size )
M and L for Replacement of old unserviceable/ damaged wooden wool pad with new wooden wool pad for three sides, for desert cooler of required specifications, complete all as specified and as directed( Cooler of iron body , standard size )
M and L for Replacement of old unserviceable/ damaged submersible water pump with new submersible water pump, AC operated, single phase, capacity 1/20 HP, 240 volts suitable for desert cooler,complete all as specified and directed.( Cooler of iron body , standard size )
M and L for Replacement of old unserviceable/ damaged Capacitors, 4.0 mfd, 50Hz, 230 Volts complete all as specified and directed. ( Cooler of iron body , standard size )
M and L for Replacement of old unserviceable/ damaged fan motor with new fan motor, AC operated, single phase, capacity 1.70 HP, 240 volts suitable for desert cooler and making necessary connection to power supply,complete all as specified and directed.( Cooler of iron body , standard size )
Taking out unserviceable /leakage/rusted bottom plate from the desert cooler and supply and fixing the new bottom plate of the fabricating with a 3 mm sheet as per sample ,complete all as specified and directed. ( Cooler of iron body , standard size )
M and L for Replacement of old unserviceable/ damaged front grill with new front grill for desert cooler of any descriptions, complete all as specified and directed. ( Cooler of iron body , standard size )
M and L for Replacement of old unserviceable/ damaged desert cooler body complete with 3mm sheet as per sample complete all as specified and directed.( Cooler of iron body , standard size )
M and L for Replacement of old unserviceable/ damaged exhast fan with motor,frame complete with new , AC operated, single phase, capacity 1.70 HP, 240 volts suitable for desert cooler and making necessary connection to power supply, complete all as specified and directed.( Cooler of iron body , standard size )
Opening up of existing deep freezer for Inspection by MES rep to ascertain due repair/replacement , of any size any type, at the site/ fixed in position and incl cleaning tinside and outside , and testing after required repair /replacement including making necessary connection to the power point complete all as specified and directed. Notes (i) Repair / Replacement of old defective spare parts/ items shall be measured and paid separately under respective items.if orederd by MES Rep (ii) Cost of transportation of water cooler/ spare parts of water cooler required being repair/replaced, from site to workshop for repair and workshop to site after repair shall be deemed to be included in quoted rates of respective item
M and L for Replacement of old unserviceable/ damaged hermatic sealed unit with new hermatic sealed unit for deep freezer 120 to 600 liters capacity, complete all as specified and directed.
M and L for Replacement/ filling of refrigerant gas (R-134a), suitable for deep freezer 320 liters capacity including testing against any leakage, complete all as specified and directed.
Inspection of air conditioner window type 1.5/ 2.0 T cap , at the site and complete servicing as per manufacturers instructions incl , cleaning/ removing the dust and filter, blower, fan motor, washing/ cleaning the outer surface and testing including making necessary connection to the power point and presenting before MES rep to ascertain repair/replacement if any , complete all as specified and directed. Notes (i) Repair / Replacement of old defective spare parts/ items shall be measured and paid separately under respective items.if orederd by MES Rep (ii) Cost of transportation of water cooler/ spare parts of water cooler required being repair/replaced, from site to workshop for repair and workshop to site after repair shall be deemed to be included in quoted rates of respective item
Inspection of air conditioner spilt type1.5/ 2.0 T cap , at the site and complete servicing as per manufacturers instructions incl , cleaning/ removing the dust and filter, blower, fan motor, washing/ cleaning the outer surface and testing including making necessary connection to the power point and presenting before MES rep to ascertain repair/replacement if any , complete all as specified and directed. Notes (i) Repair / Replacement of old defective spare parts/ items shall be measured and paid separately under respective items.if orederd by MES Rep (ii) Cost of transportation of water cooler/ spare parts of water cooler required being repair/replaced, from site to workshop for repair and workshop to site after repair shall be deemed to be included in quoted rates of respective item
M and L for Replacement of old unserviceable/ damaged hermatic sealed unit with new hermatic sealed unit (Compressor), for air conditioner window/split 1.5 T, complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged hermatic sealed unit with new hermatic sealed unit (Compressor), for air conditioner window/ split 2 T, complete all as specified and directed.
M and L for Replacement/ filling of refrigerant (R-32), suitable for air conditioner 1.5 T window type and any specifications including testing against any leakage, complete all as specified and directed.
M and L for Replacement/ filling of refrigerant (R-32), suitable for air conditioner spilt type 2.0 T and any specifications including testing against any leakage, complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged condensing coil with new condensing coil for air conditioner of 1.50 Ton capacity, window type complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged blower motor with new blower motor for air conditioner of 1.50 Ton capacity, window type, complete all as specified and directed.
M and L for Replacement of old unserviceable/ damaged PCB with new PCB, for split air conditioner of any capacity as per sample and any specifications, complete all as specified and directed.
M & L for remote controll device for window/split air conditioners size of 1.5/2.0 Ton as per sample complete all as specified and directed.
M and L for Replacement old damaged/ unserviceable connection wire with new PVC insulated, multi-stranded, copper wire, 1.50 Sqmm, 3 core, FRLS, complete all as specified and directed
M and L for Replacement old damaged/ unserviceable connection wire with new PVC insulated, multi-stranded, copper wire, 2.50 Sqmm, 3 core, FRLS, complete all as specified and directed.
Supply and replacement of box type relay type Model Sr-1622 for Air Conditioner 1.5 Ton/2 Ton capacity as per sample approved by department complete all as specified and directed.
Repair to voltage stabilizer of 5 KVA capacity, 240 Volts, single phase including M and L for Replacement of old burnt transformer winding with new copper winding wire of existing specifications for air conditioner of any capacity, complete all as specified and directed.
All as per serial item No 64 above but for voltage stabilizer 4.0 KVA capacity complete all as specified and directed.
All as per serial item No-64 above but for voltage stabilizer 2.0 to 3.0 KVA capacity.complete all as specified and directed.
All as per serial item No-64 above but for voltage stabilizer 0.50 to 1.0 KVA capacity.complete all as specified and directed.
M & L for Copper pipe of size 1/4" for 1.5 / 2 Ton split with insulation complete all as specified and directed.
M & L for repair and servicing of washing machine of cap 30 kgs front loading incl replacement of defective parts (if needed) complete all as specified and directed. Note:-cost for replacement of defective parts has been measured and paid under relevent items.
3'' Motor pulley
16'' motor bush pulley
Bearing-22210
Bearing-22310
Bearing-22215
Bearing slip-22315
Glen dori,oil seal
Door gaskit
Inner basket repair
M & L for repair and servicing of Tubler drier of 25kgs capacity incl replacement of defective parts (if needed) complete all as specified and directed. Note:-cost for replacement of defective parts has been measured and paid under relevent items.
Rubber Buffer
Hydro spring
Limit switch
Push botton with NC 0-15 Min timer.
Brake plate
1 KVA transformer
Delay off timer
SS Lock
Material and labour for rewinding of motor 2HP cap,3phase, alongwith taking out old winding wire, cleaning the slots and rewinding with superenamelled copper winding wire of existing gauge and coils and replacement of ball bearings and making electric connections complete all as specified and directed.
Material and labour for rewinding of motor 3HP cap,3phase, alongwith taking out old winding wire, cleaning the slots and rewinding with superenamelled copper winding wire of existing gauge and coils and replacement of ball bearings and making electric connections complete all as specified and directed.
Material and labour for rewinding of motor 5HP cap,3phase, alongwith taking out old winding wire, cleaning the slots and rewinding with superenamelled copper winding wire of existing gauge and coils and replacement of ball bearings and making electric connections complete all as specified and directed.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
M/S NILESH ENTERPRISES (BID ID -3292615)
M/S PRAJAPATI ENGINEERS (BID ID -3289267)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .