| 1 | L1₹9.9 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹11.2 L+₹1.2 L (12.4%)Rejected-Finance | L2 | Rejected-Finance HIGHEST | |
| 3 | L3₹12.9 L+₹2.9 L (28.6%)Rejected-Finance | L3 | Rejected-Finance HIGHEST | |
| 4 | L4₹13.0 L+₹3.0 L (29.7%)Rejected-Finance 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 | AJMER | RAJASTHAN | 305001 | L4 | Rejected-Finance HIGHEST | |
| 5 | L5₹13.7 L+₹3.7 L (37.0%)Rejected-Finance BOOTH NO 56 MAIN MARKET SECTOR 40 C CHANDIGARH U T 160036 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160036 | L5 | Rejected-Finance HIGHEST |
Tender Value
₹13.5 L
EMD Value
₹27,000
Closing Date
14 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI T C SHISHODIYA, DCWE(C)
MULTAN LINE ARMY AREA JODHPUR-342010 (RAJ)
Provn of upgradation of special power supply for NFS Node to meet the power requirement at Ralawas under AGE(I) Nagtalao
2020_MES_359999_1
CWE (A) JODH/NAG-42 OF 2020-21
Open Tender
Civil Works
Item Rate
120 days
ARMY AREA JODHPUR
4 documents required · 4 mandatory
₹500
AGE(I) Nagtalao
₹27,000
Yes
18 Feb 2021
11 Jul 2020
15 Aug 2020
11 Jul 2020
14 Aug 2020
31 Jul 2020
60 days
Amount
Taking out old Unservicebale cable from the trench of any size. Complete all as specified and directed by EIC.
M & L for Laying jointing and testing electric under ground LT cable XLPE insulated armoured aluminium conductor cable 1100 volts grade of size 150 Sqmm 3.5 core in trenches, ducts, pipe on walls, poles allas directed by Engr-in-charge.
M & L for Laying jointing and testing electric under ground LT cable XLPE insulated armoured aluminium conductor cable 1100 volts grade of size 95 Sqmm 3.5 core in trenches, ducts, pipe on walls, poles allas directed by Engr-in-charge
Excavating in trenches n.exc 1.5 m width and n.exc 1.5m in depth for taking out cable and cable cover and getting out in any type of soil Complete all as specified and directed by EIC.
Returning, filling in, soil including spreading levelling, watering and well ramming in layers n.exc 25 Cm Complete all as specified and directed by EIC.
Removing excavated materials soil n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point Complete all as specified and directed by EIC.
M&L for sand cushioning to PVC/ XLPE cables with tibba sand and punning to provide required cover to UG cables Complete all as specified and directed by EIC. Note :- For the purpose of payment only punned thickness will be measured
Laying only old retrieved stone patty/brick/PCC cover on the cable abutting each other for the cable protection gap between two adjacent patties n.exc 10mm complete all as specified and as directed by Engineer in charge.
Material and labour for laying 40 to 50 mm thick quarry faced stone slab 25 to 30 cm wide and not exceeding 60 cm long laid dry abutting each other with gap between adjacent patties n.exc 10 mm for cable protection complete all as specified and as directed by Engineer in charge.
Supply and fix GI Tubing 40 mm bore light grade (ISI Marked) with all fittings (ISI marked) and fixed complete to wall and ceiling or laid in trench. Complete all as specified and as directed by Engineer in charge.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 5 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Supply and fix UPS of three phase AC input 300 to 450V and out put 415 V ± 1% of capacity 10 KVA alongwith 30 Nos maintenance free battries of 12 V, 65 AH capacity to provide one hour power back up including suitable size of stand and battery connector. Complete all as specified and directed by EIC.
Supply and fix SMPS of three phase AC input 300 to 450V and output 48 V DC, 150 Amp (FCBC) alongwith 24 Nos maintenance free battries of 2 V, 400 AH (SMF) capacity to provide one hour power back up including suitable size of battery bank rack battery connector. Complete all as specified and directed by EIC.
M&L for point wiring with 4 Sq mm single core multi-stranded copper conductor PVC (FRLS) insulated, sheated cable 1100 volt grade in PVC casing capping 25 mm wide (ISI marked) with accessories fixed to surface of wall/ceiling with PVC sleeves as per relevant IS excluding pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 4 Sqmm single core, multi stranded copper conductor, PVC insulated, unsheated cable for common earth and connecting for earth dolly for 5 PIN 15 Amp Socket outlet on independent board.
S&F switch flush type 15 Amp single pole one way (ISI marked)
S&F socket outlet 2 in 1, 3 pin , 5 and 15 Amp 240 volts flush type (ISI marked)
M&L for sub main wiring and M&L for sub main wiring with Two runs of 4 Sqmm size main cable and one run of 4 Sqmm size earth continuty conductor of single core PVC insulated but unsheathed FRLS cable with multi standed copper conductors, 1100 volts grade, IS-694 marked all drawn through casing & caping of all fixed to the surface of wall/ceiling complete all as specefied. Note : Two runs of 4 Sqmm and one run of 4 Sqmm of single core cables conductors shall be measured as one runs length.
Supply and fix single pole and neutral enclousure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amp complete all as directed by engineer in Charge
S & F VTPN distribution board, 4 way, 415 volts suitable for flush and surface mounting should have 200 Amps copper bus bar for each phase, 2 Neutralbar , 2 earthbar and cable ties for cable management, fully insulated bus bar & shrouded neutral bars including provision for 100/ 63 Amps MCCB as incomer and SP/TP MCB as outgoing and electrically connecting up complete all as specified and directed.
S&F MCCB 4 Pole, thermal magnetic relase type, 100 Amps, 16 KA 415 Volt AC 50 Hz, Ics=Icu 100%. Complete all as directed by engineer in Charge.
S & F MCB's C curve including necessary incoming and out going electric connection with suitable size of copper lugs etc. (a) TP, 63 Amp 10 KA, 'C' curve 415 volts.
All as per item No 22 but SP 6-32 Amps, 10 KA, 'C' curve 240 volts.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4 mm dia GI wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 5 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Nvimal Engineer and Contractor
vinayandsons
M/S JAGDAMBA ENTERPRISES
L-7 Primewave Communications
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .