Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 212 338 OLD DALANWALA DEHRADUN DEHRADUN UTTARAKHAND 248001 | DEHRADUN | UTTARAKHAND | 248001 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹98 L
EMD Value
₹2.0 L
Closing Date
12 Dec 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer (CED PD and EP)
Power Distribution, 2nd Floor, PD and Utility Building, Nuclear Fuel Complex, Hyderabad-500062
Servicing and Testing of Switch gear, Transformers, Capacitor banks and other equipment including retrofitting works at substations and load centers of NFC, Hyderabad
2025_NFC_879729_1
NFC/PD/5/2025
Open Tender
Electrical Works
Works
NFC Hyderabad
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹2.0 L
22 Oct 2025
30 Sept 2025
17 Dec 2025
3 Oct 2025
12 Dec 2025
9 Oct 2025
3 Oct 2025 - 8 Oct 2025
Amount
Testing & Servicing of following ratings of L&T make LT air circuit breakers with release and of model CNCS / C Power / U Power / Omega (cost of maintenance kit shall be included in the respective breaker servicing cost)
630Amps ACB
800 Amps ACB
1000 Amps ACB
1250 Amps ACB
2000 Amps ACB
2500 Amps ACB
3200 Amps ACB
4000 Amps ACB
Supply of spare L& T make LT ACBs and retrofit services
Supply and retrofit of 3200A C power ACB
Supply of CNCS 3200A, 65 kA 3 pole EDO type C power ACB with microprocessor based release SR18G
Retrofitting services of 3200A C power ACB in existing 3200A CNCS (old type) breaker cubicle with complete Busbarlinks and Hardware (modification of bus bar, supply of bus bar links included )
Retrofitting services of 2500A C power ACB in existing 2500A CNCS (old type) breaker cubicle with complete Busbarlinks and Hardware (modification of bus bar, supply of bus bar links included )
Installation of jaw contacts for 1 pole of 2500A ACB
Supply of spares for existing L&T make LT ACBs (model CNCS/C power)
Shunt release 240 V AC
Spring charge Motor 240 V AC
Closing coils 240 V AC
Safety shutters
Moving arcing contacts suitable for existing 630-1250A ACB(1 set consists of arcing contacts for 3 poles of breaker)
Fixed Arcing Contact suitable for existing 630-1250 A ACBs (1 set consists of arcing contacts for 3 poles of breaker)
Microprocessor based type SR18G Protection releases
Jaw contact Assy suitable for existing 630-1250 A ACB
Jaw contact Assy suitable for existing 2500C ACB
Cradle Terminal Assy suitable for existing 630 A to 1250 A ACBs
Cradle Terminal supports suitable for existing 630 A to 1250 A ACB
Arc chutes suitable for existing 630A to 1250A ACB
Testing & Servicing of following ratings of Schneider make LT air circuit breakers with release and of model MVS/NW/MTZ2/merlin gerlin
630 Amps ACB
800 Amps ACB
1000 Amps ACB
1250 Amps ACB
1600 Amps ACB
2000 Amps ACB
2500 Amps ACB
3200 Amps ACB
Supply of spares for existing Schneider make LT ACBs (model MVS/NW/MTZ2)
Supply of 3200A,66 kA 3 pole EDO ACB of type MTZ with microprocessor based release Micrologic 6.0X
Supply of 2500A,66 kA 3 pole EDO ACB of type MTZ with microprocessor based release Micrologic 6.0X
Supply of 3200A,65 kA 3 pole EDO ACB of type NW with microprocessor based release Micrologic 6.0E
Supply of 2000A,65 kA 4 pole EDO ACB of type NW with microprocessor based release Micrologic 6.0E
Supply of 2500A,50 kA 3 pole EDO ACB of type MVS with microprocessor based release ET6A
Supply of 800A,50 kA 4 pole EDO ACB of type MVS with microprocessor based release ET6A
Supply of closing release suitable for NW /MTZ
Supply of shunt release suitable for NW /MTZ
Supply of U/V coil suitable for NW /MTZ
Testing & Servicing of following ratings of Siemens make LT air circuit breakers with release and of model WL
2500 Amps ACB
2000 Amps ACB
1600 Amps ACB
1250 Amps ACB
1000 Amps ACB
800 Amps ACB
400 Amps MCCB
Supply of spares for existing Siemens make LT ACBs (model WL)
Closing release
Shunt release
Testing of Transformer oil as per IS 1866 as per Technical specifications which includes collection of sample, shipping of samples to labs and other associated works
Condition Assessment Tests of Power Transformers as per Technical Specifications which includes disconnections & connections of terminations
Condition Assessment Tests of 3-Pole gang operated Circuit Breakers as per Technical Specifications which includes disconnections & connections of terminations
Condition Assessment Tests of 3 core-Current Transformers as per Technical Specifications which includes disconnections & connections of terminations . One set of CTs means 3-Core CTS of R, Y B phases
Condition Assessment Tests of Potential Transformers as per Technical Specifications which includes disconnections & connections of terminations . One set of PTs means PTs of R, Y B phases
Condition Assessment Tests of 3-pole gang opertaed Isolators as per Technical Specifications which includes disconnections & connections of terminations.
Condition Assessment Tests of Lightning Arrestors as per Technical Specifications which includes disconnections & connections of terminations . One set of LAs means LAs of R, Y B phases
Condition Assessment Tests of Capacitor Banks including series reactor as per Technical Specifications which includes disconnections & connections of terminations . One three phase bank will have multiple numbers of rated capcitor connected in parellel in the form of star/ double star/ delta . Series reactor connected in series with the each phase of the Bank.
SKYLINE ELECTRICALS (BID ID -3319922)
stage.html
html • 0.01 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
corr1.pdf
PDF • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .