Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹40.6 L
EMD Value
₹1.2 L
Closing Date
2 Mar 2026, 6:00 pmClosed
EXEN REW BARAMULLA
BARAMULLA
C/O 3-KLD FAECAL SLUDGE TREATMENT PLANT AT KOHLINA DANDMOOH. BLOCK WAGOORA
2026_RDPR_303648_2
237/Xen/Rew/Bla/2025-2026 Dated 17/02/2026
Open Tender
Civil Works
Percentage
45 days
BARAMULLA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,600
Rural Development and Panchayati Raj
₹1.2 L
3 Mar 2026
17 Feb 2026
3 Mar 2026
17 Feb 2026
2 Mar 2026
17 Feb 2026
Earth work for lowering and levelling the ground other than foundation works by mechanical means upto 3.00m depth , including providing shoring, strutting,and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, filling back the excavated earth to the extent required and utilising/transporting the remaining earth upto 1.00 KM lead including the cost of Labour & HOM of Machineries, as per drawing and technical specification
Providing and Filling in foundation with granite / trap broken metal 100mm. And down size, with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift. complete as per specifications including Frequency of Cube Test, Slump test to be performed at site as per MORTH specifications and to be tested for strength parameters from BIS/NABL approved labs at the cost of contractor
Carriage by Mechanical means.
Providing and laying in position plain cement concrete of grade M 10 with OPC cement @ 220kgs, with 20mm and down size graded granite metal coarse aggregates @0.84cum and fine aggregtes @ 0.56cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick,well compacted, in foundation,plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications.incl. carriage by M.T lead 1 km including Frequency of Cube Test, Slump test to be performed at site as per MORTH specifications and to be tested for strength parameters from BIS/NABL approved labs at the cost of contractor
Carriage by Mechanical means.
Carriage of Cement by MT
Providing and laying in position plain cement concrete of grade M 15 with cement @ 240kgs, with 20mm and down size graded granite metal coarse aggregates @0.878cum and fine aggregtes @ 0.53cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM of machinery, curing complete as per specifications.ncl. carriage by M.T lead 1 km
Carriage of material By MT
Carriage of cement By MT
Providing and laying in position reinforced cement concrete of Design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.460 cum, with super plasticisers @ 3 liters confirming to IS 9103-1999 reafirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick,vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, walls (any thickness ) including attached pilasters, columnspillars, posts, struts, buttresses, bed blocks,anchor blocks & plinths etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications..ncl. carriage by M.T lead 1 km.base slab for percolate channel.
Base Slab for PDB
Wall at Percolate channel (type raft Fold)
Long wall near screening Chamber
long wall at outlet
Short walls
Screening chamber long walls
Screening chamber short walls
Tie Beam
Carriage of material By MT
Carriage of Cement by MT
Extra for use of water proofing compound in cement concrete grade of M20 at one kg of compound per bag of cement.
Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) including for OHT & reservoier, cost of materials, labour, HOM of machinery complete as per specifications. .ncl. carriage by M.T lead 1 km steel allowed of SAIL, TATA STEEL, JSW STEEL, Jindal steel having clear brand marks, ISI/BIS certification,embossing of the manufacturer's name
Carriage of steel by MT
Providing and constructing burnt brick Massonary for basement and superstructure with approved quality of non-modular bricks of standard size of class designation 3.5 Newton per sqm with cement mortar (1:6)mix complete job.
Carriage of Bricks By MT
Carriage of cement By MT
Centering and shuttering including strutting,propping and removal of same.
Centering and shuttering including strutting,propping and removal of same.
P/A 20mm thick cement sand plaster in (1:4)mix all complete.
Carriage of material By MT
P/F unplasticised PVC pipes with working pressure 10kg/sq.cm with pipe fittings clips making good the floor including cost of all materials labour charges HOM and testing complete as per specifications. 110 mm dia.,110mm dia vent pipe.,110mm dia PBB outlet.,outlet pipe,PDB TO ISAF.
110mm dia.tees.
110mm dia.elbow
110mm dia.end cap
160mm dia.pipes for support.
P/L of coarse aggregates size as below after washing and sieving to make it free from fines and dust.53 mm nominal size.
20mm nominal size
10mm nominal size
sand/Artificial sand/Manufactured sand
Supplying/Casting and fixing Precast Reinforced Cement Concrete perforated slabs (2" dia hole) of following thickness in RCC 1:2:4, using following HBGS jelly including cost of reinforcement steel in position, cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed. Percolate channel perforated slabs (670*500*75)mm.
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: 2.9.1 All kinds of soil :
P/L dry stone dry stone solling (100)size consolidated rammed filling the voids compacting all including including all carriages.
P / L( 1:3:6)mix cement concrete of specified grade using crushed stone aggregates 20mm size. Granite metal coarse aggregates @.84 cum @.56cum including all carriages
Providing and laying in position reinforced cement concrete of Design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.460 cum, with super plasticisers @ 3 liters confirming to IS 9103-1999 reafirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick,vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, walls (any thickness ) including attached pilasters, columnspillars, posts, struts, buttresses, bed blocks,anchor blocks & plinths etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications..ncl. carriage by M.T lead 1 km.ISAF Base SLAB
ISAF long wall
ISAF short wall
Extra for use of water proofing compound in cement concrete grade of M20 at one kg of compound per bag of cement.
Reinforcement for RCC work including cutting bending binding and placing in position etc wherever required complete job.TMT bars Fe 500.
Formwork of ordinary timber planks for in situ concrete work including removal and all complete.
Formwork of ordinary timber planks for in situ concrete work including removal and all complete.
Formwork of ordinary timber planks for in situ concrete work including removal and all complete.
Brick work with common burnt clay (non-Modular) bricks of class designation 7.5 in (1:6)mix all complete and of approved [email protected] Newton per Sqm.
P/A 12mm thick cement sand plaster in (1:4)mix all complete.
P/F unplasticised PVC pipes with working pressure 10kg/sq.cm with pipe fittings clips making good the floor including cost of all materials labour charges HOM and testing complete as per specifications. 110 mm settler inlet pipes.including vent
160 mm dia (AF Pipes)
110mm dia tees
110mm dia elbows
110mm dia end cap
P/L of 120mm-150mm size free from derbis and dust includes procuring transportation and laying into the anerobic filter as per instructions of Engineer incharge.
Supplying /Casting and fixing precast Reinforced cement concrete perforated slabs (2" Dia hole)of following thickness in RCC (1:2:4) including cost of reinforcement steel in position cost of moulding charges casting of slab finishing curing and fixing in .Maintenance covers 600mm*60mm*50mm
Preforated slabs 480mm*580mm*75mm
Carriage of Sand aggregate by MT 20 km
Carriage of Coarse aggregate by MT 20 km
Carriage of Stones average lead of 5 km
Carriage of Bricks by 35 km
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: 2.9.1 All kinds of soil :
P/L dry stone dry stone solling (100)size consolidated rammed filling the voids compacting all including including all carriages.
P / L( 1:3:6)mix cement concrete of specified grade using crushed stone aggregates 20mm size.granite metal coarse aggregates @.84cum and fine @.56cum machine mixed including all carriages
Providing and laying in position reinforced cement concrete of Design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.460 cum, with super plasticisers @ 3 liters confirming to IS 9103-1999 reafirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick,vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, walls (any thickness ) including attached pilasters, columnspillars, posts, struts, buttresses, bed blocks,anchor blocks & plinths etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications..ncl. carriage by M.T lead 1 km.RCC Base SLAB.
Long Wall
short Wall
Extra for use of water proofing compound in cement concrete grade of M20 at one kg of compound per bag of cement.
Reinforcement for RCC work including cutting bending binding and placing in position etc wherever required complete job.TMT bars Fe 500.
Formwork of ordinary timber planks for in situ concrete work including removal and all complete.
Formwork of ordinary timber planks for in situ concrete work including removal and all complete.
P/A 12mm thick cement sand plaster in (1:4)mix all complete.
Extra for use of water proofing compound in cement plaster for brick work at one kg per bag or in the proportion recommended by the manufacturers for cement mortar (1:4) 20mm thick cost of material complete as per specifications.
P/F unplasticised PVC pipes with working pressure 10kg/SQ.cm with pipe fittings ,clips making good the floor including cost of all materials labour charges HOM and testing complete asper specifications.110mm Dia.(DC inlet),110mm Dia out let,110mm dia pipe to SP.including all tees ,elbows and caps complete.110mm Dia (DC inlet and outlet).
110mm dia Tees
110mm dia elbows
110mm dia end cap
110mm dia perforated sampling pipe
110mm dia perforated pipe
P/L of coarse aggregates size as below after washing and sieving to make it free from fines and dust.120mm nominal size.(at inlet and at center)
120mm nominal size (at outlet).
20mm nominal size
20mm nominal size
12mm nominal size
Carriage of Sand aggregate by MT 8 km
Carriage of Coarse aggregate by MT 8 km
Carriage of Stones average lead of 5 km
Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil :
Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material :All kinds of soil :
Random Rubble masonry with hard stone in foundation and plinthincluding leveling up with cement concrete 1:6:12 (1 Cement : 6coarse sand : 12 graded stone aggregate 20mm nominal size) uptoplinth level and curing complete with Cement mortar 1:6 (1 Cement : 6 coarse sand) Quarry
Dry random rubble masonry with hard stone in foundation and With bond stone. Quarry
Reinforced cement concrete work in well-steining including curing but excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for:Well steining
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete
Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110mm nominal dia (inlet and outlet)
Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain waterpipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.110 mm dia tee
Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain waterpipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.110mm dia elbow
Carriage of Coarse aggregate by MT 20 km
Carriage of Stones average lead of 15 km
Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil :
Filling available excavated earth in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Hand-packing stones /Dumping stone in Horizontal on level
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) PCC bed for registers
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.PCC bed for Registers
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand)
20mm Cement plaster of mix:1 : 4 ( 1 cement : 4 fine sand)
Supplying/Casting and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two sand and four aggregates), using following HBGS jelly including cost of reinforcement steel in position, cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and 750 mm x 750 mm x 50 mm
Carriage of Sand aggregate by MT 8 km
Carriage of Coarse aggregate by MT 8 km
Carriage of Stones average lead of 5 km
Carriage of Bricks by 5 km
Providing, fabricating,fixing of SS Screens using SS 304 bars, 20 mm spacing of 4 mm thick with handle (7.5kg) including cost of material, transportation, labour charges etc complete as per direction of Engineer in incharge.Including GST.
Supplying and fixing of CI openable cover with frame and hinges,coat of epoxy coating transportation labour charges etc all complete.At screen chamber (600*600)mm.including GST
Pocuring and planting rhizomes such as canna indica water lilly vertiver etc at an interval of 0.5 m including transportation and planting.At PDB(4 Plants per sqm) and AT PGF (4 Plants per sqm).including GST.
110mm nominal dia vent cowl premium with wire mesh including GST.
Earth work in rough excavation, banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and lift upto 1.5 m in all kinds of soil: Carraige upto 5 kms
P/L of Granular sub-base (GSB) by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achievethe desired density, complete as per specifications and directions ofEngineer-in-Charge With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30. and carriage mt 5 kms
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
carriage of sand/agg for 20kms lead
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Mild steel and medium tensile steel bars
Photograph charges /SiGNBOARD Engraved granite stone
stage.html
html • 0.02 MB
finance_986091.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.92 MB
BOQ_986091.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .