| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 163 B 2 CHOWDHURY ROAD BARDDHAMAN | BARDDHAMAN | BARDDHAMAN | WEST BENGAL | Admitted-Finance |
Tender Value
₹3.5 L
EMD Value
₹7,100
Closing Date
22 Sept 2023, 5:00 pmClosed
AEE (C), IWD on behalf of IISER Kolkata
IISER Kolkata, IWD Section, Mohanpur 741246 Dist. Nadia, West Bengal
Tissue Culture room partition and anti-fungal paint in room no W227 of AJC Bose Research Complex
2023_IISER_769021_1
IISER-K/Civil/23-24/09
Open Tender
Civil Works
Item Rate
30 days
IISER Kolkata, Mohanpur
As per tender document
9 documents required · 9 mandatory
₹500
IISER KOLKATA
₹7,100
10 Nov 2023
29 Aug 2023
25 Sept 2023
29 Aug 2023
22 Sept 2023
29 Aug 2023
Amount
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
In cement mortar
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).
Providing and fixing colour anodised aluminium work for partition made up with 1.5 mm thick aluminium tubular section. 2.5" x 1.5"as frame, fixed with rawl plugs and screws etc. including cleat angle, aluminium snap beading for glazing/ panelling, panel to be covered with 9 mm thick both side laminated particle board and 5 mm thick Glass including rubber and taper clip etc. all complete as per direction of Engineer-in-Charge.
Standard walls are a composite construction of two skins of High Pressure Laminated over aluminium framework with a sealed and insulated interior. Standard panel chargable heights are 1220 mm wide with an overall length of 2500, 2800, 3100 mm. Standard panels have an overall thickness of 50mm. the semi monocoque construction is self supporting. the self supporting, insulated walls are constructed with an interior aluminium framework. A 70 mm floor track is used to level and support the wall system. Panel to panel connections are maintained with precision by aluminium profiles that create uniform (4 mm) seams. The panel seams are selaed by silicone with a perfectly flush finishing. Insulation materials are sandwiched between the two skin layers and sealed from the exterior by the aluminium framework. The standard insulation material for the wall system is polyurethene. W45 HPL-HDPU-HPL (walls) 45 mm self supporting wall provided in modular units consisting of external skins in High Pressure Laminated, 4 mm thick on both sides, with protective film to prevent surface damage during shipping and insulation. Movable wall includes: * HDPU - 37 mm. High Density Expanded Polyurethene (40 kg/m3) * H aluminium profile between wall sections provide the precision 4 mm seal gap * A 70 mm aluminium floor trail for panel support * Silicon sealant
Covings and wall connections
(a) Horizontal/vertical coving
(b) 3D corners
Providing and fixing anodised aluminium work for door shutter, frame made up with 1.5 mm thick aluminium tubular section 45 mm x 45 mm as vertical member, top and middle section - 50 mm x 45 mm, bottom section 100 mm x 45 mm and panel covered with 9 mm thick both side laminated particle board including rubber gasket, aluminium snap bidding and taper clip, with decorative aluminium handle, hydraulic door closer, neoprene gasket including locking arrangement, stainless steel hinge, screw etc all complete.
i) Door shutter (sliding/hinged).
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.
New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T 2430 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall bysteel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 6 mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Standard Ceiling Board (Density > 1300 Kg/m3) of size 595 mm X 595 mm, conforming IS 14862 & Type B Category III of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge. In ground floor.
False Ceiling (with 6mm thick Fibre Cement Designer Board and E-Grid T-2430).
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .