Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.2 LAccepted-AOC 5 KHANAURI MANDI TEHSIL MOONAK MOONAK SANGRUR PUNJAB 148027 | SANGRUR | PUNJAB | 148027 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹44.6 L+₹54,451.18 (1.23%)Rejected-Finance | L2 | Rejected-Finance Rejected being higher than L1 | |
| 3 | L3₹44.9 L+₹78,383.86 (1.78%)Rejected-Finance 99 C PIPE ROAD CHINIAMORE PO BARRACKPORE PS TITAGARH DIST 24 PARGANAS N KOLKATA 700120 WB | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L3 | Rejected-Finance Rejected being higher than L1 | |
| 4 | L4₹45.0 L+₹91,797.82 (2.08%)Rejected-Finance 14 4A KALI PRASAD C HAKRABORTY ST CAL KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | L4 | Rejected-Finance Rejected being higher than L1 | |
| 5 | L5₹46.1 L+₹2.1 L (4.65%)Rejected-Finance | L5 | Rejected-Finance Rejected being higher than L1 |
Tender Value
₹40.5 L
EMD Value
₹81,000
Closing Date
15 May 2025, 6:00 pmClosed
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
PROVISION OF CERTAIN WORK SERVICES AT 72 RMU AT AF STN BARRACKPORE
2025_MES_704036_1
8617/BKP/AF OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
GE AF Barrackpore
Class-D,
Category-a(i)
2 documents required · 2 mandatory
₹500
GE AF Barrackpore
₹81,000
Yes
16 Jun 2025
9 Apr 2025
17 May 2025
9 Apr 2025
15 May 2025
23 Apr 2025
Amount
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down chowkats or frames with shutters exc. 1.50 Sqm but n.exc. 4.00 Sqm each (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkats or frames with shutters n.exc. 1.50 sqm each (without taking off shutters from the frames) complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position including removing debris from site of work complete all as specified and directed.
Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc. and removal of rubbish from the site complete all as specified and directed.
Material and labour for 15mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces with using water proofing coumpound (WPC) @ 200 ml/ bag (50 Kg) of cement or as per manufacturers instruction and finish the surfaces even and smooth without using extra cement as in wall complete all as specified and directed. Note : WPC will be measured and paid separately under respective item.
Material and labour for 10mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar (1:6) and finish the surfaces even and smooth without using extra cement as in wall complete all as specified and directed.
Material and labour for complete removal of existing treatment on walls and applying two coats of acrylic washable distemper over a coat of alkali resistance primer complete all as specified and directed.
Material and labour for preparation of new plastered surfaces of walls and applying two coats of acrylic washable distemper over a coat of alkali resistance primer complete all as specified and directed.
Materials and labour for applying 2mm thick wall care putty complete all as specified and directed.
Material and labour for preparation of new plastered surfaces of walls and applying two coats of 100% premium acrylic emulsion paint (Camouflage pattern) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming one coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed.
Material and labour for preparation of old decorated surfaces of walls and applying one coat of 100% premium acrylic emulsion paint (Camouflage pattern) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 0.715 litre/ 10 sqm complete all as specified and directed.
Supply and fix powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified and directed.
Supply and fix anodised powder coated (minimum thickness of powder coating 50 micron) aluminium frames for door, window , ventilators with one or more rebates including joining cleats for fixing etc complete all as specified and directed.
Supply and fix 18/19mm thick block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber framework complete all as specified and directed.
Supply and fix 5.50 mm thick sheet glass, ordinary quality and glazing with oil putty or rubber beadings, clips, aluminium beadings in aluminium frame in square/rectangle exc 0.5 sqm in each pane complete all as specified and directed.
Supply and fix 12 mm thick frameless toughened glass door shutter (single or double leaf) of approved brand and manufacture, including providing and fixing top & bottom pivot, floor door spring fixing and arrangement and making necessary holes etc and fixing required door fittings( fancy type handle, locking arrangement complete all as specified and directed.
Supply and fix mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work etc. conforming to Fe.290.Gde-E-165 complete all as specified and directed.
Supply and fix 4.00 mm thick frosted sheet glass, ordinary quality and glazing with oil putty or rubber beadings, clips, aluminium beadings in aluminium frame in square/rectangle n. exc 0.5 sqm in each pane complete all as specified and directed.
Supply and fix SS Butt hinges medium weight 100mm size complete all as specified and directed.
Supply and fix SS Butt hinges medium weight 75mm size complete all as specified and directed.
Supply and fix 150mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and as directed.
Supply and fix 125mm size aluminium alloy handles, fabricated type extruded section complete all as specified and directed.
Supply and fix 75mm size aluminium alloy handles, fabricated type extruded section complete all as specified and directed.
Supply and fix 100 mm brass mortice lock, vertical type, 4 levers complete all as specified and directed.
Supply and fix double action floor spring heavy duty hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel complete all as specified and directed.
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 m in depth for foundation etc or for cess well cess pits man holes pier holes etc n.exc 10 sqm on plan n.exc 1.5 m in depth and getting out soft/loose soil complete all as specified and directed.
Material and labour for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate ) as in foundation, filling and mass concrete complete all as specified and directed.
Materials and labour for river sand filling under floors including watering and consolidation complete all as specified and directed.
Material and labour for brick work with fly ash brick, modular size, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
Material and labour for providing 40 mm thick Damp proof course in cement concrete 1:2:4 type B-0 (using 12.50 mm graded stone aggregate) to horizontal or vertical surfaces including necessary formwork and applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cum per sqm complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Material and labour for glazed ceramic tiles of size 450x300x7mm (premium quality) coloured in vertical surfaces such as riser of steps, skirting, dado and pillar set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10mm thick cement plaster in cement mortar (1:4) complete all as specified and directed.
Material and labour for vitrified ceramic tiles (premium quality) 8 to 10mm thick, light shade as approved, polished area of each tiles n. exc. 0.36 Sqm (square/ rectangular) in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
Material and labour for ceramic, non skid coloured tiles (premium quality) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not exc. 0.18sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
Supply and fix PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls or laid in trenches or in floors complete all as specified and directed .
Supply and fix 75 mm bore PVC (SWR) bends of any radius with access door complete all as speified and directed.
Supply and fix PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls or laid on floors complete all as specified and directed .
Supply and fix 110 mm bore PVC (SWR) bends of any radius with access door complete all as speified and directed.
Supply and fix health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
Supply and fix gun-metal globe or gate valves 20 mm dia with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
Cutting chases, pinning in existing brick wall and making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
Supply and fix 20 mm bore steel tubes medium grade, galvanised, with all fitting and fixed to walls, ceilings, roofs or laid in floors complete all as specified and directed.
Supply and fix 15 mm bore steel tubes medium grade, galvanised, with all fitting and fixed to walls, ceilings, roofs or laid in floors complete all as specified and directed.
Supply and fix 15 mm bore CP fancy type stop valves, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both,ends for iron pipe or for unions and fixed complete all as specified and directed.
Supply and fix vitreous china wash hand basin, white, flat back, size 550x400mm excluding taps, waste pipe, chain & plug and porcelain stopper but with brackets, including cutting for and pinning in and including 32mm dia waste fitings cast copper alloy chromium plated with long screwed shanks and flynuts flange and beded in red lead cement, 32mm dia PVC waste pipe 800mm long including 15mm bore dia fancy type CP finish pillar tap, cast copper alloy with capstan heads, screwed down high presuure, with or without lettered hot or cold with long screwed shanks and fly nuts, screwed for iron pipe/fittings complete all as specified and directed.
Supply and fix 15mm bore fancy type pillar tap long body (swan neck type) cast copper alloy with capstan heads, chromium plated, screwed down, high pressure with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and directed.
Supply and fix cast Iron floor trap with grating of 75 mm dia outlet including jointing to waste pipe fixed in cement concrete type (1:2:4) B-1 (using 20mm graded stone aggregate) complete all as specified and directed.
Supply and fix 75mm dia cast iron nahani trap with gratings including joining to waste pipe fixed in cement concrete type B1 (1:2:4) (using 20 mm graded stone aggregate) complete all as specified and directed.
Supply and fix vitreous china white wash down water closet pan (pedestal pattern) with ‘P’ or ‘S’ trap, front or back inlet, fixing bolts and making all necessary connections including plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete as specified and directed.
Supply and fix 10 litre PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets including flushing pipe complete all as specified and directed.
Supply and fix 15mm bore fancy type, chromium plated, bib tap, cast copper alloy with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specified and directed.
Supply and fix 15 mm bore CP fancy type angle cock, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both,ends for iron pipe or for unions and fixed complete all as specified and directed.
Supply and fix PVC connection pipe 15 mm size with PTMT nuts at both ends of length 600 mm complete all as specified and directed.
Supply and fix 100mm dia stainless steel grating doom with hole fixed with cement complete all as specified and directed.
Supply and fix 100mm dia stainless steel grating doom without hole fixed with cement complete all as specified and directed.
Supply and fix soap dish, brass chromium plated, fancy type, fixed to plugs with chromium plated fixed with brass screws complete all as specified and directed.
Supply and fix solid PVC door frame of size 50 mm X 47 mm made out of 5 mm plain coloured PVC sheet reinforced with mild steel square tube as per specification and drawing given on MES schedule Part–II (2020) complete all as specified and directed.
Supply and fix factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as specified and directed.
Supply and fix rolled mild steel in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) of Fe 410 -W (Gde-E- 250) quality-A including one shop coat of red oxide zinc chrome primer complete all as specified and directed.
Supply and fix 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based corrugated / semi corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and directed.
Material and labour for hardcore of broken stone or boulder of gauge n.exc 63mm, deposited, spread and leveled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
Material and labour 75mm thick PCC (1:4:8), type D-2 (using 40 mm graded stone aggregate) as in sub-base or base course of floor complete all as specified and directed.
Material and labour for joint free anti skid outdoor pavement coloured tiles (good grip series) of size 300 x 300 x 12mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 20mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
Material and labour for 75mm thick PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) as in plinth protection, laid in panels including finishing the concrete surface even and smooth without using extra cement including forming costruction joint 30mm deep x 10mm wide filled with sealing compound of group 'A' complete all as specified and directed.
Material and labour for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Material and labour for PCC (1:2:4) type B-10 (using 12.50 mm grade stone aggregate) as in kerb/ benching/ coping including form work complete all as specified and directed
Material and labour for RCC (1:2:4) (nominal mix) type B-1 (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Form work to sides and soffits of floor or roof beams, slab, girders, bres-summers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. with rough finished flat surfaces of concrete complete all as specified and directed.
Cutting into existing manholes for connecting new drain pipe of dia 150mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) smooth finished, and reforming benching as required complete all as specified and directed.
Supply and fix false ceiling with powder coated exposed GI grid suspension system (E-grid T-2430 or equivalent load carrying capacity- 12.50 Kg/sqm with mid span deflection n. exc. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long of size- 24x38mm x 0.25mm thick, cross tee of section size- 24x27mm x 0.25mm thick 1200mm/600mm long and wall angle of section size 22x22mm x 0.4mm thick. The wall angle shall be fixed on PVC dash fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The main runners to be placed @ 1200mm, The cross tee 1200mm will be inserted in pre-cut slots of main runner at a regular interval of 600mm to form a modular grid of 1200mmx600mm. Additional cross tee of 600mm shall be placed perpendicular to the cross tee1200mm long to finally form a grid of 600mm x 600mm shall be supported by 4mm dia G.I. wire from perlins/soffits. 6mm thick high pressure steam cured Everest non Asbestos fibre cement designer ceiling board (density> 1200kg/cum, modules of rupture (M.O.R)-15.85 Mpa, thermal conductivity (k)-0.0872 W/mk) of size 595mm x 595mm, confirming to IS 14862 & type B catagory III of ISO 8336-1993, (Reaction of fire-A2 -s1-d0) tested as per EN 13501 Part-I & BS-476 part-4, 5, 6 & 7, should be placed in the grid module to form a false ceiling complete all as specified and directed. Note: Work shall be executed through authorised applicator of OEM as approved by GE. Make: Armstrong/ Saint Gobain/ Lafarge/ Everest.
Supply and fix solid PVC wall lining consisting of 5 mm thick wood grain printed colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed.
Supply and fix 5mm thick PVC sheet fillet of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame complete all as specified and directed.
Material and labour for 25mm thick PCC (1:2:4) type B-0 (using 12.50mm graded stone aggregate) as in floor and finished the surface even and smooth without using extra cement complete all as specified and directed.
Material and labour for applying 5.00 mm thick Nitoflor SL Conductive system, anti-static self-smoothening (ESD) flooring on concrete surface having moisture content less than 5%, Electrical resistance of floor surface to earth between 50 kilo ohms to 2 mega ohms measured with wet electrode. Surface preparation includes grinding of concrete surface, proper cleaning, removing of loose mortar, paint residuals, curing compound residues and existing joints shall be open & joint edges shall be repaired by epoxy putty followed by application of Nitoprime 25 - epoxy resin based primer for concrete surface using brush or roller, and allow curing for 8-10 hours (depending upon temperature). Mixing of base, hardener and filler components of Nitofloor EU5 - high strength self smoothening epoxy underlay using slow speed drill and poured on prepared surface at 1.5mm DFT all as specified over copper strip grid of 1mX1m work made out of using 20mmX0.2mm thick copper strips forming one square meter grid jointly of surface by pasting suitable adhesive and connect the same to the earthing point complete all as specified and directed. Note:- (a) The work shall be executed by authorised applicator of the manufactures as approved by GE. (b) Make: Fosroc/ Asian Paints Ltd/ Sika/ Fosroc
Material and labour for cutting down vegetation growths like plants / trees of girth n exc 15cm from roof top / sides, external walls of bldgs, chajjas, wall juctions/ at junction of rain water / CI waste water pipe junctions including removal of roots and taking out carefully possible quality of concrete in roofs embedded in walls / slab surfaces making good affected locations and applying approved chemical (herbal medicine) to arrest further growth and making good the distrubed surfaces with PCC (1:2:4) type B-1 or CM (1:2) complete all as specified and directed. Note : The quoted rate shall be deemed to include the cost of scaffoloding / staging upto four storey bldgs.
Complete removal of existing roof treatment in any layers and disposal of debris from site complete all as specified and directed. Notes: - (a) The rates are inclusive of removal for any type of old water proofing treatement over main RCC slab. (b) Bidders are advised to visit the site and esure about site condition before quoting their rates. (c) Demolition of PCC/ taking down plaster if any shall be measured and paid saparately under respective items.
Material and labour for 15mm thick rendering in cement mortar (1:4) with using water proofing coumpound (WPC) @ 200 ml per bag of cement or as per manufacturers instruction on roof top and finish the surfaces even and smooth without using extra cement including taking down existing cement plaster and disposal of debris from site complete all as specified and directed. Note : WPC will be measured and paid separately under respective item.
Supply only liquid water proofing compound (WPC) complete all as specified and directed.
Material and labour for water proofing treatment to RCC roof surface comprising with the following course of treatment/specifications from bottom to top :- (a) Applying cold bituminous primer @ 0.30 liters per sqm confirming to IS 3384 over plastered surfaces of roof. (b) One layer of APP based polymeric membrane 3mm thick, weight not less than 3.50 kgs per sqm, reinforced with non woven polyester matt central core fabric (weight not less than 160 GSM) and coated on both side with and including layer of APP modified bitumen and finished with and including micro-prefabricated heat fusible polythene film on both surfaces. (c) Applying one coats of hot bitumen 85/25 grade @ 1.20 kg per sqm over membrane surface. (d) Finally applying two coats of aluminum paint @ 0.10 ltrs per sqm per coat on top surface. Contd...
Note:- (i) The work shall be executed only through authorised applicator of manufacturer as approved by GE. (i) Laying of APP based polymeric membrane shall be done by torch on method or as per manufacturers instructions. (ii) A minimum overlap of 150mm and 100mm should be made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturers instructions. Make of APP membrane:- Super Thermolay of M/s STP Ltd, Hyperplas of M/s IWL India Ltd, Hydrostop of M/s Tiki Tar Danosa (India) pvt ltd, , M/s FOSROC Chemicals, Smartcare APP membranes of M/s Asian Paints Ltd.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Material and labour for light/fan point wiring (concealed type) with single core PVC insulated unsheathed multistranded FRLSH copper conductor cable of 1100 volts grade size 1.5 sqmm (nominal area) in and including heavy duty rigid non metalic 20mm dia PVC conduit with accessories including modular flush metal boxes for housing switches, sockets and regulators with all fittings and fixing materials with one single core PVC insulated unsheathed 1.5 sqmm (nominal area) multistranded FRLSH copper conductor as earth continuity wire and connected to earth dully complete all as specified and directed. Note:- (a) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (b) Quoted rate shall be included for cuttings /chasing the wall and making good disturbed surfaces to fix PVC conduit and modular flush metal boxes. (c) Accessories like inner and outer modular cover plates and modular flush metal boxes shall be measured and paid under respective items.
All as per item No. 85.00 here-in-before but for one five pins 5 Amps switch socket outlet point on independent board and -ditto-.
All as per item No. 85.00 here-in-before but for one five pins 5 Amps socket outlet point on same board and -ditto-.
All as per item No. 85.00 here-in-before but for 15 amps socket outlet on independent board with 2.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade including 2.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade as earth continuity conductor and connecting to common earth dolly and -ditto-.
Supply and fix modular switch 1 way 6 amps, 1 module complete all as specified and directed
Supply and fix modular switch 1 way 16 amps, 1module complete all as specified and directed.
Supply and fix modular shuttered sockets 6 amps, 2/3 pin combined two module complete all as specified and directed.
Supply and fix modular shuttered sockets 6/16 amps, 2/3 pin combined two module complete all as specified and directed.
Supply and fix modular white cover plate with frame of 3 module complete all as specified and directed.
Supply and fix modular white cover plate with frame of 4 module complete all as specified and directed.
Supply and fix modular white cover plate with frame of 8 module complete all as specified and directed.
Supply and fix modular flush metal box 3 module complete all as specified and directed.
Supply and fix modular flush metal box 4 module complete all as specified and directed.
Supply and fix modular flush metal box 8 module complete all as specified and directed.
Supply and fix rigid non-metallic PVC conduit of 25mm dia including all fittings such as tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed.
Material and labour for concealed sub-main wiring comprising single core , 2 runs of 6 sqmm nominal cross sectional area, FRLSH multistranded copper conductor cable, PVC insulated unsheathed 1100 volts grade drawing in and including appropriate dia of PVC conduit and its fittings complete including provision of 1x6 sqmm nominal cross sectional area, single core FRLSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire including taking down old unserviciable existing sub- main wiring complete all as specified and directed. Note :- (i) Extra length of cables/ wire required for connection to MCBs/DB's shall be included in quoted rate. (ii) Cuttings /chasing of wall etc and making good the disturbed surface shall be measured and paid seperately under respective items.
Material and labour for concealed sub-main wiring comprising single core , 4 runs of 10 sqmm nominal cross sectional area, FRLSH multistranded copper conductor cable, PVC insulated unsheathed 1100 volts grade drawing in and including appropriate dia of PVC conduit and its fittings complete including provision of 1x10 sqmm nominal cross sectional area, single core FRLSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire including taking down old unserviciable existing sub- main wiring complete all as specified and directed. Note :- (i) Extra length of cables/ wire required for connection to MCBs/DB's shall be included in quoted rate. (ii) Cuttings /chasing of wall etc and making good the disturbed surface shall be measured and paid seperately under respective items.
Supply and fix in repair 36 W LED recessed ceiling light with glare free uniform illumination, white powder coated CRCA housing, with transulcent frosted diffuser and driver inbuilt 4KV surge protection, efficacy > 100 lm/W, CRI ≥80, 5700K suitable for 600 x 600 mm (2 feet x 2 feet) grid ceiling complete with all accessories including internally prewired connecting upto flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix in repair LED tube light fitting 1 x 20W (+/- 5%), 220V, AC with extruded strip in thermally conductive material & extruded housing in optically efficient material milky white with system lumen efficacy > 120 lumen per watt minimum system 2300 - 2400 and chip, Integrated electronic driver, SMD based LED constant current supply with double sided connection to avoid short circuit and surge protection greater than 2.5 KV, IP 20 protection and CRI>80, Power factor > 0.95, THD less than 15%, correlated Colour temperature (CCT) of 6500K, Operating Voltage of 140 V to 270 V, frequency of 50Hz burning hours 50000 hours with comprises of CRCA pre coated metal housing complete all as specified and directed
Supply and fix air circulation wall mounted fan, metal body AC single phase. 230V, 50 Hz, oscillating type of size 450 mm sweep with pull botton regulator type complete all as specified and directed. Make:- Crompton Greaves/Havells/ Bajaj/ Orient /Usha.
Supply and fix in repair sheet metal enclosure SPN DB 8 ways double door having facility to fix MCB in incomer and MCBs in outgoing, metal door IP-43 type complete fitted with bus bars, neutral links, blanking plates complete all as specified and directed.
Supply and fix in repair sheet metal enclouser SPN DB 4 ways double door having facility to fix MCB in incomer and MCBs in outgoing, IP-43 type complete fitted with bus bars, neutral links, blanking plates complete all as specified and directed.
Supply and fix sheet metal enclouser VTPN DB 4 ways double door having facility to fix MCCB in incomer and MCBs in outgoing, IP-43 type complete fitted with bus bars, neutral links, blanking plates complete all as specified and directed.
Supply and fix MCCB 100 Amps current capacity, 415V, 25 KA, 4 Pole, with adjustable thermal and magnetic type complete all as specified and directed.
Supply and fix MCCB enclsure G frame four pole suitable for MCCB 100 Amp including necessary connection complete all as specified and directed. Make- LEGRAND /HAVELLS /L & T/ SCHNEIDER
Supply and fix MCB TP, 240 Volts, 63 amps, "C" series, breaking capacity 10 KA complete all as specified and directed.
Supply and fix in repair MCB SPN, 240 Volts, 40 amps, "C" series, breaking capacity 10 KA complete all as specified and directed.
Supply and fix in repair MCB SP, 240 Volts, of 6 to 32 amps current rating, 10 KA breaking capacity "C" series complete all as specified and directed.
Supply and installation of advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgraded (zinc & alloy coated), zinc coating ( 80-100) microns with pure zinc (99.9%) & alloy coating (200-250)microns. Earthing system conforming to IS-3034, ASEEL-39. The outer and inner pipe should be 76.2 mm & 41.9 mm, 3mtrs length, zinc coated with additional special alloy coating 300mm on the top side for additional corrosion protection of the terminal. The annular space between the pipes being filled up with COMPACT FILL(CF) (Crystalline Conductive Compound). The COMPACT FILL (CF) mixture which is machine pressed in the pipes should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity. The job includes digging the pits of dimension 60cm X 60cm up to depth of 3.1m and replace the soil with low resistive soil as approved by Engr-in-Charge, then make a bore of dia 200mm of depth 3.1m and refilling the same by conductolite back fill compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material / metal having RoHS Certification from NABL accredited lab. Good earth is to be arranged to fill the excavated pits by mixing the same with BFC 2 bags (conductolite) including FRP (Fiber reinforced plastic) light weight, high mechanical strength, chemical resistance with detachable easy locking lid of size 250mm X 250mm of thickness 2mm and the earthing should be installed by applicator of the manufacturer / authorised dealer complete all as specified and directed. Make- ASHLOK / MACKMET/CAPE
Material and labour for earthing continuity conductor or main earthing lead fixed to wall or recess or chases with 20 x 3.15 mm copper strip fixed on porcelin insulator at distance 100 cm including nut bolt drilling hole etc complete all as specified and directed. Note : Joining of copper strip shall be made by brazing after fixing of nuts & bolts.
Supply, installation, testing and commissioning of energy rating 5 star, inverter split Air Conditioner capacity 2 Ton with indoor and outdoor unit comprising of the following:- (a) Multi-stranded copper conductor wire 4 core, 2.50 Sqmm not less than 3.0 mtrs with copper lugs. (b) Incoming and outgoing high quality copper pipe with foam insulation duly white taped of each size not less than 3.0 mtrs. (c) Key features: - (i) Multi adjustable mode. (ii) High ambient cooling. (iii) Super dry. (iv) Turbo cooling. (v) Anti microbial air filteration. (vi) Eco-friendly refrigerant R-32/ R-410A. (vii) 100% copper. (viii) Sleep mode. (ix) Wide voltage range operation. (x) The ISEER vlaue of Air Conditioner shall be 4.5 (minimum). (xi) Cordless remote - 01 No.
Notes: - (i). Extra copper pipe and multistranded copper conductor wire required for Air Conditioner to be installed on parapet wall of building roof top shall deemed to be included in quoted rate. (ii). Rate for scaffolding/ladder/tools and plants required to install Air Conditioner i.e. for making holes to wall, drilling, making good disturbed surfaces and matching with the existing colour shall deemed to be included in quoted rate. (iii) Outdoor unit should be kept above the level of Indoor unit. For installaiton of ground floor ACs oudoor should be on wall surfaces and for first floor ACs should be on parapet wall of roof top of the building with out extra cost to the Govt all as directed by Engr-in-chrg. (iv) The MES No should be painted on indoor and outdoor unit with navy blue colour letters of size not less than 15 mm height. Drain pipe should be clamped up to plinth protection. No extra claim should be allowed for drain pipe from indoor unit to plinth protection of outside the building. (v) The quoted rates are also inclusive of making holes in brick/stone wall for installation of Air Conditioner and making good to the exisitng surface with putty and paint in as specified and directed by Engr-in-charge.
Supply and fix AC outdoor wall mounted bracket of mild steel suitable for 2 ton split AC with nut & bolts complete all as specified and directed
Supply, install, commissioning and testing of commercial Air curtain unit for prevention of dust and conditioned air losses, single phase, 220 V, 50 Hz, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with one coat of red oxide primer over two coats of synthetic enamel paint (oven baked) with MS - CRC 18 gauge square perforated suction grills, aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 1-1.5 m/sec air velocity at floor level for door opening size of 46" x 84" complete all as specified and directed. Make:- ALMONARD/ CROMPTON GREAVES/ AIRCON
Material and labour for concealed sub-main wiring comprising single core , 2 runs of 4 sqmm nominal cross sectional area, FRLSH multistranded copper conductor cable, PVC insulated unsheathed 1100 volts grade drawing in and including appropriate dia of PVC conduit and its fittings complete including provision of 1x4 sqmm nominal cross sectional area, single core FRLSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire including taking down old unserviciable existing sub- main wiring complete all as specified and directed. Note :- (i) Extra length of cables/ wire required for connection to MCBs/DB's shall be included in quoted rate. (ii) Cuttings /chasing of wall etc and making good the disturbed surface shall be measured and paid seperately under respective items.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240 V, 20 Amps "C" series complete all as specified and directed. Make:- LEGRAND / SCHNEIDER / SEIMENS / HAGER / L&T / C&S
Material and labour for earthing complete with copper earth plate electrode of size 600 x 600 x 3.15mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to copper strip of size 20 x 3mm earth lead by means brazing after fixing of nuts, bolts, check nuts, washers of galvanised iron steel, protected by HDPE pipe 40mm dia of pressure rating 6 kgf/cm2 all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 40 x 40 x 6cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion including taking down old existing unserviciable earthing set complete all as specified and directed. Note:- Strip upto 7.5m length including testing shall be included in quoted rates.
Material and labour for earthing continuity conductor or main earthing lead fixed to wall or recess or chases with 20 x 3.15 mm copper strip fixed on porcelin insulator at distance 100 cm including nut bolt drilling hole etc ncluding taking down old existing unserviciable earthing strip complete all as specified and directed. Note : Joining of copper strip shall be made by brazing after fixing of nuts & bolts.
Taking down old unserviceable copper rod air termination, from exisiting pole from 6 mtr height and refixing the pole on same location after roof treatment including necessary fixing arrangement using clamp, nuts and bolts complete all as specified and directed
Material and labour for air termination single pointed copper rod, 12mm dia and 300mm long including necessary fixing arrangment using clamps,nuts and nuts complete all as specified and directed.
Material and labour for test point termination box made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos, 8 mm dia, 25mm long hexagonal heads screw for lighting conductors complete all as specified and directed.
Supply and fix HDPE pipe of 25mm dia, 6Kgf/cm2 pressure fixed on wall/laid in trenches for earth strip protection including ceramic saddles and nut bolts complete all as specified and directed.
Material and labour for cutting, bending, welding of MS flat iron of size 30mm x 3mm for making of clamps as required size and shape including nut/bolts and painting with two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
M/S. B. N. CHATTERJEE (BID ID -3297435)
Renuka Fero Products (BID ID -3297585)
ROY CONSTRUCTION (BID ID -3297901)
SARKAR AND COM (BID ID -3297753)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .