Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC | L1 | Accepted-AOC Quoted L1 | |
| 2 | L2₹17.2 L+₹20,423.68 (1.21%)Rejected-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L2 | Rejected-AOC Quoted L2 | |
| 3 | L3₹17.2 L+₹22,385.51 (1.32%)Rejected-AOC 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L3 | Rejected-AOC Quoted L3 | |
| 4 | L4₹18.3 L+₹1.4 L (8.24%)Rejected-AOC SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | L4 | Rejected-AOC Quoted L4 | |
| 5 | L5₹21.6 L+₹4.6 L (27.3%)Rejected-AOC HYDERABAD TELANGANA 500076 INDIA UDYAM TS 02 0009467 | MEDCHAL MALKAJGIRI | TELANGANA | 500076 | L5 | Rejected-AOC Quoted L5 |
Tender Value
₹21.9 L
EMD Value
₹43,800
Closing Date
3 Mar 2022, 6:00 pmClosed
GE(AF) Chandigarh
GE(AF) Chandigarh PIN-160003
REPAIR TO WATER SUPPLY LINE, ELECTRIC VABLE, AC, DG STE ETC AND COOLING APPLIANCES AT AF STN BARWALA
2022_MES_505970_1
GE(AF)/CHD/T-53/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Barwala
All as per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE(AF) Chandigarh
₹43,800
Yes
2 May 2022
4 Feb 2022
5 Mar 2022
4 Feb 2022
3 Mar 2022
18 Feb 2022
4 Feb 2022 - 10 Feb 2022
Amount
EXTERNAL ELECTRIFICATION
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles etc. and getting out, complete all as specified and directed.
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Material and labour, locally available, sub class `B’ bricks (old size), laid flat and dry perpendicular to the direction of cable adjacent to each other, in trenches over the cable for protection, complete all as specified and directed.
Relaying only well burnt brick sub class 'B' old size brick laid dry in trenches with width equal to the length of the brick , complete all as specified and directed. Note:- Bricks are to be reused retrived during the cable taking out
Taking out / down old existing LT 1100volt grade cables, size 2x10Sqmm, aluminium conductor 2core, XLPE/ PLCA/ PVC, armoured, laid in trenches, including bricks for protection, sand cushioning and stacking, removal to store for re-use or for credit, complete all as specified and directed Note : Excavation shall be measured and paid for separately
All as per Serial Item No. 1.07 here-in-before but 16Sqmm 2Core size
All as per Serial Item No. 1.07 here-in-before but 16Sqmm 4Core size
All as per Serial Item No. 1.07 here-in-before but 25Sqmm 3.5Core size
All as per Serial Item No.1.07 here-in-before but 35Sqmm 3.5Core size
All as per Serial Item No. 1.07 here-in-before but 50 Sqmm 3.5Core size
All as per Serial Item No. 1.07 here-in-before but 70 Sqmm 3.5Core size
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated and armoured, heavy duty, electric power cable, cross sectional area 10Sqmm 2 core aluminum conductor 1100volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: Returning filling & removal of earth, sand cushioning and bricks for protection of cable shall be measured and paid separately.
All as per Serial Item No. 1.14 here-in-before but 16Sqmm 2Core size
All as per Serial Item No. 1.14 here-in-before but 16Sqmm 4Core size
All as per Serial Item No. 1.14 here-in-before but 25 Sqmm 3.5Core size
All as per Serial Item No. 1.14 here-in-before but 35Sqmm 3.5Core size
All as per Serial Item No. 1.14 here-in-before but 50Sqmm 3.5Core size
All as per Serial Item No. 1.14 here-in-before but 70Sqmm 3.5Core size
Supply, jointing & testing, indoor end termination joint kit (Heat shrinkable) complete with jointing material and accessories suitable for 3wire, 11KV (Earthed) grade, HT, underground XLPE insulated armoured aluminium conductor cable, 3core, 95Sqmm size cable, complete all as specified and directed
Supply, jointing & testing, outdoor end termination joint kit (Heat shrinkable) complete with jointing material and accessories suitable for 3wire, 11KV (Earthed) grade, HT, underground XLPE insulated armored aluminium conductor cable, 3core, 95Sqmm size cable, complete all as specified and directed
Supply, jointing & testing, straight through joint kit (Heat shrinkable) complete with jointing material and accessories suitable for 3wire, 11KV (Earthed) grade, HT, underground XLPE insulated armoured aluminium conductor, 3core, 95Sqmm size cable, complete all as specified and directed
Supply and laying / fixing , GI pipe light grade 100mm dia bore for cable protection fixed to pole/wall or laid under floor/road /pavement, including flat iron clamp, nut, bolt, washer etc of required size and taking out old & removal, complete all as specified and directed. Note: Boring of holes under road etc. shall be measured and paid separately.
All as per item No 1.24 here - in before but GI pipe 80mm dia bore complete all as specified and directed.
All as per item No 1.24 here - in before but GI pipe 50mm dia bore complete all as specified and directed.
Material and labour for switch air break, gang operated triple pole ,mechanically operated, mounted on 12 insulators including drop out insulators including 3 nos barrel type drop out fuses and steel frame with operating mechanism worked from ground level with 25mm light grade GI tubing for current rating upto 400 amps,11000 volt including taking down old and removal complete all as specified and directed.
Material and labour for lightning arresters high tension ,expulsion type complete with all fittings, transmission class ,discharge capacity 65 kilo amp ,suitable for 11000 volt grade system fixed in position including disconnecting and taking down old and removal complete all as specified and direced
Supply and filling of transformer oil of superior quality having di-electric strength not less than 40 KV at 4.0mm gap, ISI marked and filling into transformers and other equipments installed at various locations, after taking out old unserviceable oil, complete all as specified and directed. Note:- (i) Transformer oil will be supplied in duly filled in sealed drums. (ii) Necessary test certificate provided from authorised lab or state electricity board test lab.
Supply and fixing in replacement the under mentioned spare/parts of transformer capacity from 50 KVA to 200KVA, complete all as specified and directed.
Air breather assembly with silica gel
HT side procelain bush 11KV (Set of 03) with brass studs, nuts & washers, rubber gasket etc
LT side procelain bush 415V upto 100KVA transformer (Set of 04) with brass studs, nuts & washers, rubber gasket etc
LT side procelain bush 415V upto 200KVA transformer (Set of 04) with brass studs, nuts & washers, rubber gasket etc
Dismantling/Strip opening of the HT VCB 11KV 400 Amps for calibration, repairing, preventative maintenance, servicing including replacement of worn out parts to make it fully functional, reassembling the same after repair, installation to its original position, connection input/output supply, testing to its full load capacity and all other relevant tests as per IE/IS rules, complete all as specified and directed. Note: Spare parts required for repair/replacement shall be maeasured and paid separately.
Supply and fixing in replacement under mentioned spare/parts 11KV, 400 Amps HT VCB, any model/type of make :- Kirloskar/Crompton complete all as specified and directed.
Supply only Potenional Transformer (PT) of 11KV/110V , totally enclosed, sealed and stamped, epxoy filled, heavy duty, suitable for 11 KV 400 Amps HT VCB, complete all as specified and directed.
Supply only, Micro process based relay heavy duty, suitable for 11 KV 400 Amps HT VCB, complete all as specified and directed.
Supply only, vaccum interruptor for VCB, complete all as specified and directed.
Supply only, trolly insulator for mounting vaccum interruptor for VCB, complete all as specified and directed.
Supply only, epoxy fibre base plate for interruptor, complete all as specified and directed.
Supply only, epoxy insulator for bus bar supports, complete all as specified and directed.
Supply and fix, finger moving contact (Made up of six, each male and female, fingers), spring loaded, heavy duty, suitable for 11KV, 400Amp, HT VCB, complete all as specified and directed.
Supply only, Current Transformer (CTs) of CTR 50-25 / 5Amps, totally enclosed, sealed and stamped, epxoy filled, heavy duty, suitable for 11 KV 400 Amps HT VCB, complete all as specified and directed.
Supply and fix, in replacement MCCB, four pole, 400Amps, 415 volts, 50 KA, 50Hz , with adjustable thermal and magnetic release, complete with extension links and making connection in panel board, complete all as specified and directed.
Supply and fix, in replacement MCCB, four pole, 250Amps, 415 volts, 35 KA, 50Hz , with adjustable thermal and magnetic release, complete with extension links and making connection in panel board, complete all as specified and directed.
Supply and fix, in replacement MCCB, four pole, 200Amps, 415 volts, 35 KA, 50Hz , with adjustable thermal and magnetic release, complete with extension links and making connection in panel board, complete all as specified and directed.
Supply and fix, in replacement MCCB, four pole, 160Amps, 415 volts, 25 KA, 50Hz , with adjustable thermal and magnetic release, complete with extension links and making connection in panel board, complete all as specified and directed.
Supply and fix, in replacement MCCB, three pole, 200Amps, 415 volts, 25 KA, 50Hz , with adjustable thermal and magnetic release, complete with extension links and making connection in panel board, complete all as specified and directed.
Supply and fix, in replacement MCCB, three pole, 160Amps, 415 volts, 25 KA, 50Hz , with adjustable thermal and magnetic release, complete with extension links and making connection in panel board, complete all as specified and directed.
Supply and fix, in replacement MCCB, three pole, 125Amps, 415 volts, 25 KA, 50Hz , with adjustable thermal and magnetic release, complete with extension links and making connection in panel board, complete all as specified and directed.
Supply and fix, in replacement MCCB, three pole, 63Amps, 415 volts, 16 KA, 50Hz , with adjustable thermal and magnetic release, complete with extension links and making connection in panel board, complete all as specified and directed.
supply and fixing timer digital 24 hr single phase with contactor rating(A) 65/TP and MCB rating 63/SPN sap code IHXSS03120
Demolition of cement concrete (unreinforcement) as in coping /foundation of poles and other similar work including removal of rubbish outside MOD land complete all as specified
Suply and fixing/erecting true vertical position ,Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31, 9 MTR Long complete all as specified and directed. Note: Earth work and pcc shall be measured and paid seperately.
Material and Labour for PCC 1:2:4 type B-1 using 20mm graded stone aggregate for coping incuding necessary form work, complete all as specified and directed.
Material and Labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate for foundation and mass concrete filling, complete all as specified and directed.
Demolition of concrete foundation and taking out existing pcc poles and removal of pole to store for reuse or credit and disposal of dibris outside MOD land, including disconnecting and taking down oldstreet light fittings, complete all as specified and directed..
Material and Labour for Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections Fe-290 grade E-165 quality including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size including two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Dismantling and taking down ,cross arms of ms channel or angel channel or angle section ,including clamps bolt washers etc , and removal ,complete all as specified and directed.
Material and labour, painting two coats of aluminium paint to steel tubular poles of any description (external surface only) including MS cross arms etc making of 5 strips of width 300mm each (03 Nos Sky blue and 2 No. white) writing pole No. with black paint with letters/figures in girth 3 inch, including preparation of old painted surface, complete all as specified and directed.
Material and labour for painting two coats of cement base paint to old painted surfaces PCC poles 9 meter long any description (external surface only) and including painting 6 strips of height 0.3 mtr with synthetic enamel paint each (three nos sky blue & three nos white), writing pole no with black paint with letters /figures 7.5cm high including preparing of old painted surface complete all as specified and directed by Engineer-in-charge
M & L cable jointing kit for 1100 Volts (Earthed) grade cable for straight through joint complete with jointing materials and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 Sqmm to 50 Sqmm complete all as specified.
M & L cable jointing kit for 1100 Volts (Earthed) grade cable for straight through joint complete with jointing materials and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 Sqmm to 95 Sqmm complete all as specified.
Finding out the fault in LT 1100 Volts grade underground cable laid in less than 100 cm deep in trenches and its rectification, complete all as specified and directed. Note: The fault should be rectified within six hours from received message from AGE/JE. If the fault not rectified with in six hours the penalty per hour Rs. 500/- to be made from the contractor.
Finding out the fault in HT 11000 Volts grade underground cable laid in more than 100 cm deep in trenches and its rectification, complete all as specified and directed. Note: The fault should be rectified within six hours from received message from AGE/JE. If the fault not rectified with in six hours the penalty per hour Rs. 500/- to be made from the contractor.
Material and labour, earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron strip of size 32mmx6mm thick (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm dia bore, and watering pipe 20mm dia bore GI medium grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete all as specified and directed.
Material & labour, Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete all as specified and directed.
Material and labour for GI strip 32x6mm as in earth continuity conductor , complete all as specified and directed.
Material and labour for copper strip 20x3.15mm as in earth continuity conductor , complete all as specified and directed.
Material and labour for test point made out of copper strips 32x6mm, 200mm long - 02 Nos and 12mm dia brass nuts bolts 40mm long - 03 Nos , complete all as specified and directed.
Material and labour for test point made out of GI strips 50x6mm, 200mm long - 02 Nos and 12mm dia GI nuts bolts 40mm long - 03 Nos , complete all as specified and directed.
DG SET REPAIRS
Maintenance of DG set of any make, type, model as per set norms of the original manufacturer set and by the authorised rep of the company after unscrewing nut, bolts, screws etc. for servicing, maintenance, tigthtening, adjustment & cleaning of all moving and stationary parts of DG set, complete and segregating the parts for repair/ refixing/ replacing of capacity 40KVA installed at Pump house No.3,sub stn No.3&4, & AFNET(02 no,s) , complete all as specified and directed. Make of DG sets :- kirloskar/Crompton Greaves/Mahindra & Mahindra Note: The quoted rate includes the following: (a) Taking down of unserviceable parts. (b) Any minor repair, replacement of minor parts such as screws, gasket, nuts, bolts, washers, cleaning & greasing etc. of DG set parts. (c) Defective parts/ engine oil to be replaced will be measured & paid separately under supply only item as apended below.
All as per Serial Item No. 1 here-in-before but capacity 63 KVA installed at sub stn No.1 power house
Supply and fix only under mentioned spare/parts suitable for the DG set complete all as specified and directed:-
Primary fuel filter element for DG set capacity 40KVA
Primary fuel filter element for DG set capacity 63KVA
Secondry fuel filter element for DG set capacity 40KVA
Secondry fuel filter element for DG set capacity 63KVA
Air filter element for DG set capacity 40KVA
Air filter element for DG set capacity 63KVA
Oil filter element for DG set capacity 40KVA
Oil filter element for DG set capacity 63KVA
Water hose pipe set complete for DG set capacity 40KVA
Fuel and oil hose pipe set complete for DG set capacity 40KVA
Fuel and oil hose pipe set complete for DG set capacity 63KVA
Material and labour for taking out radiator and repairing/brazing to make it leakage free, cleaning and re-fixing the radiator including testing for DG set capacity 10KVA to 40KVA, complete all as specified and directed.
Material and labour for taking out radiator and repairing/brazing to make it leakage free, cleaning and re-fixing the radiator including testing for DG set capacity 63KVA, complete all as specified and directed.
Supply only lubricant oil (Engine oil) SAE30 (Make as recommended by the manufacturer of DG set and as approved)
Supply, install, connecting and testing in replacement maintenance free batteries, 12 Volts, 180AH, complete all as specified and directed.
Supply, install, connecting and testing in replacement maintenance free batteries, 12 Volts, 130AH, complete all as specified and directed.
Supply and fix, battery lead not less than 1.5mtr long, made out of 50Sqmm copper cable with terminal of brass with marking (+)/(-) and fixing in position and testing, including taking down and removal, complete all as specified and directed.
Supply and filling, engine coolant in radiators of DG sets as per DG set manufacturer's recommendations at different locations, brought at site in sealed packets, complete all as specified and directed.
Maintenance, repair, servicing and calibration of automatic mains failure panel, DC & 415/440 volt AC supply operated system by locating faults and replacement of unserviceable parts and components for DG set 30KVA to 40KVA and testing on completion , complete all as specified and directed. Make of DG sets:- Kirloskar/Crompton Greaves/Ruston/Ashok Leyland Note: The quoted rate includes the following: (a) Taking down of unserviceable parts. (b) Any minor repair, replacement of minor parts such as screws, gasket, nuts, bolts, washers, cleaning & greasing etc. of DG set parts. (c) Defective parts/ engine oil to be replaced will be measured & paid separately under supply only
Repair of faulty worn out control wiring DC/AC for engine starting and off, with adequate and suitable size copper conductor wire, connected with proper copper lugs & terminals through protection pipe/casing, complete all as specified and directed.
Repair of worn out/faulty internal wiring of controls and timers, indicating/measuring instruments through various control fuses and relays with suitable and adequate size of copper conductor wire, connected with suitable copper lugs and terminals, complete all as specified and directed.
Replacement of worn out small control fuses, indicating lamps, various type of copper lugs, thimbles terminals all as deemed necessary or directed including minor spare parts and components in order to make system serviceable and perfectly in working order , complete all as specified and directed.
M & L for replacing the unserviciable AVR of DG sets up to the capacity of 15 to 63 KVA and testing complete all as specified and directed by Engineer in charge
Supply and Fix in repair, Power contractor 3 pole 63 Amps 415 volts operating coil , complete all as specified and directed.
M & L repairs to unserviceable street/security lights fittings of LED, of any wattage and size by taking down from poles/buildings after disconnecting the electric connection, replace the unserviceable drive ,PVC connector etc, cleaninng, refixing the light fittings at its original position after rectifying the defects and connecting to street light feeder including testing complete all as specified and directed. Note :- (i) Replacement of parts like drive , will be measured and paid seperatily as supply only (ii) The cost of labour ,tools and minor spares required for replacement of parts shall deem to include in the unit rate quoted by the contractor.
PVC insulated stranded aluminium conductor, 1100 volts grade heavy duty cable of size 2.5Sqmm 2 core (from junction box to street light fitting mounted on steel tubular/PCC pole) including taking down existing unserviceable cable, complete all as specified and directed.
Supply and fixing electronic drive suitable for LED street light /Flood light of capcity up to 90W all as specified and and directed by Engineer in charge
Supply and fix in replacement of LED street light fitting 60W AC 230V 50 Hz powder coated pressure die cast alluminum housing power LED with heat resistant toughned glass IP 66 complete all as specified and diredted by Engineer in charge
Supply and fix in replacement of LED street light fitting 45W AC 230V 50 Hz powder coated pressure die cast alluminum housing power LED with heat resistant toughned glass IP 66 complete all as specified and diredted by Engineer in charge
Open construction ballast copper wounded for 70 watts HPSV/MH lamps
Metal halide lamp 70 watts, 230 volts, single/double ended tubular/ballon type
Ignitor suitable for 400/250/150/70 watts HPSV/MH lamp
Lamp holder procelain suitable for 400/250/150/70 watts HPSV/MH lamp
Supply and fix junction box of size 30CMx20CMx15CM made out of mild steel CRCA sheet 2mm thick duly painted with synthatic enamal paint (internally and externally) over a coat of red oxide primer and provision of hinged door with locking arrangements and fixing with steel tubular poles with two nos MS flat iron clamps 25mmx3mm made to shape with nuts ,bolts,washers etc and provision of alluminum bus bar 100A four nos & MCB SPN 6Amps ,10 KA 240Volts complete all as specified and directd by Engineer in charge
Supply and fix junction box of size 30CMx20CMx15CM made out of mild steel CRCA sheet 2mm thick duly painted with synthatic enamal paint (internally and externally) over a coat of red oxide primer and provision of hinged door with locking arrangements and fixing with steel tubular poles with two nos MS flat iron clamps 25mmx3mm made to shape with nuts ,bolts,washers etc and provision of alluminum bus bar 100A two nos & MCB SPN 6Amps ,10 KA 240Volts complete all as specified and directd by Engineer in charge
S & F in repair on-load change over switch four pole, 100A, in sheet steel enclousure complete all as specified.
S & F in repair on-load change over switch four pole, 200A, in sheet steel enclousure complete all as specified.
WATER SUPPLY AND SEWAGE INSTALLATION
Taking out defective submersible pump & motor set 6 to 8 stage, 700-900 LPM at 112mtr head of any dia upto 150mm from bore well with the help of chain pulley after disconnecting electrical connections from motor starter, disconnecting the column pipe from supply pipe line, opening each column pipe by unscrewing nut bolt, rubber packing of each column pipe, submersible cable and keeping a side for reuse the number of column pipe to be taken out upto 24-28 Nos. alongwith submersible cable, for repair / replacement of parts to make it fully functional, reassembling the same after repair, lowering/ installation to its original position, electric connection of input/ output electric supply, connecting the column pipe to supply pipe line testing to its full load capacity at least for 4 hours and all other relevant tests including any minor repair, replacement of rubber gasket for column pipe etc. transportation to workshop and vice-versa, complete all as specified and directed by the Engineer-in-Charge.
Dismantling of submersible motor 25 to 35 HP 415 volts 50 Hz 3 phase AC electric supply, taking out the burnt winding of stator, removal of burnt insulation material from the slots, cleaning the stator slots and preparation for rewinding the same and material and labour for winding the stator of motor with PVC insulated copper wire of standard size and superior quality copper winding wire as per the existing gauge including the F class insulation materials, turning, balancing & alignment of rotor etc. to get the proper RPM and torque & tested to its full load capacity complete all as specified and directed Note :- Spare parts required to be replaced shall be measured and paid separately as 'Supply only'.
Opening of pump set 6 to 8 stage, 700-900LPM at 112mtr head for repair and replacement of unserviceable parts, reassembling the same after repair, machining work of impeller housing, remetaling of pump shaft, grinding, scraping, cleaning and balancing the same to make it fully functional at the full load capacity including turning, balancing & alignment of shaft etc. reassembling of complete Pump & Motor set and testing on completion for the entire satisfaction of Engineer – in - Charge all as directed. Note:- Spare parts required to be replaced shall be measured and paid separately as 'Supply only'.
Supply only of motor housing rotor bush for 25 to 35 HP submersible motor complete all as specified and directed.
Supply only of water seal for 25 to 35 HP submersible motor complete all as specified and directed.
Supply only of thrust bearing set for 25 to 35 HP submersible pump complete all as specified and directed.
Supply only bush Gun metal for 700-900LPM submersible motor complete all as specified and directed.
Supply only impeller Gun metal for 700-900LPM submersible pump complete all as specified and directed.
Supply only impeller neckring for 700-900LPM submersible pump complete all as specified and directed.
Supply only impeller bush for 700-900LPM submersible pump complete all as specified and directed.
Supply only impeller locknut for 700-900LPM submersible pump complete all as specified and directed.
Supply only stainless steel shaft for 700-900LPM submersible pump complete all as specified and directed.
Supply only of Coupling set including key and MS nut bolt suitable for submersible pump sets, complete all as specified and directed.
Supply and fixing/laying in replacement cable submersible PVC insulated water proof with copper conductor cable 3x16sqmm ,1100 volt grade after taking out old unserviceable cable confirming to IS complete all as specified and directed by Engineer-in-charge.
Taking out self priming non clog pump set after removal of electrical connections, disconnecting suction/ delivery pipeline connection, from sewage well upto 6m depth and transportation to workshop for repair & vice versa. Refixing after carrying out repair /rewinding of non clog pump set electrically driven by 3phase 415volts capacity 5HP complete all as specified and directed by Engineer-in-charge. NOTE:- Repair / spare parts shall be measured & paid for separately
Taking out the burnt winding of stator of submersible/squirrel cage/TFT motor, removal of burnt insulation material from the slots, cleaning the stator slots and preparation for rewinding the same. Material and labour for winding the stator of motor 5HP with PVC insulated copper wire of standard size and superior quality as per the existing turns & gauge including 'F' class insulation materials to get the proper RPM and torque. Turning, balancing & alignment of rotor etc. Complete all as specified and directed. NOTE:- Repair / spare parts shall be measured & paid for separately
Supply only spares/parts suitable for pump and motors complete all as specified and directed for the followig:-
Terminal block of motor of capacity upto 5HP 415volts.
Bearing any type for motor of capacity upto 5HP 415volts.
Remettaling of motor & pump shaft including polishing and balancing.
Impeller including bush, lock nut etc. any type / capacity
Gland cup
Misc items i.e. stud, MS nut, bolts, keys etc..
Supply only sodium Hypo chlorite( NaOCL) chemical solution conforming to IS-1673/86 having chloride content 10 % by weight (bleach liquid solution) complete all as specified and directed by Engineer-in Charge. Note : Chemical solution shall be supplied by the contractor as on requirement basis through out the currency of the contract .Therefore the contractor shall procure the chemical solution in piecemeal as per requirement .The material shall be deposited with AGE E/M-1 (A/F) High ground and RV shall be prepared accordingly. Contractor shall also arrange independent testing of chemical from Govt authorized laboratory at his own expense. The cost of testing shall be deemed to be included in the quoted rate. Payment of supply of Sodium chlorite solution shall only be made on production of test report.
Supply and fix in repair electronic metering dozing pump with following technical specification, complete all as specified :- Item : Dosing Pump Model : TJ - MD 8 Capacity (lph) : 0 – 6 Back Pressure (kg/cm2) : 10 Drive : Solenoid Capacity adjustment :- 1. Adjustable stroke frequency between 0 to 100 strokes/min 2. Adjustable stroke length between 0 to 100% MOC of wetted parts : PP MOC of diaphragm : PTFE coated EPDM Power (W) : 30 Power supply : Single phase 230V, 50 Hz Accessories : Foot Valve, Injection Fitting and 3 mtrs Hose pipe Make : Toshcon Jesco or equivalent in Appx `B'
Taking up/down old GI pipe 20mm dia bore with fittings, laid in trenches, under floors or on roof, along walls etc, stacking serviceable and removal of unserviceable pipe, complete all as specified and directed. Note : Excavation & earthwork shall be measured and paid separately.
All as per item No 3.26 but GI pipe 25mm bore complete all as specified and directed by Engineer-in-charge.
All as per item No 3.26 but GI pipe 40mm bore complete all as specified and directed by Engineer-in-charge.
All as per item No 3.26 but GI pipe 50mm bore complete all as specified and directed by Engineer-in-charge.
Supply and laying GI pipe medium grade 20mm dia with all fittings laid in trenches/fixed along with walls or laid under floors, complete all as specified and directed. Note :- Excavation & earthwork shall be measured and paid separately.
All as per item No 3.30 but GI pipe 25mm bore, complete all as specified and directed .
All as per item No 3.30 but GI pipe 40mm bore, complete all as specified and directed .
All as per item No 3.30 but GI pipe 50mm bore, complete all as specified and directed .
Supply and fix, Gun Metal gate valve with iron wheel head, screwed both ends for 20mm dia bore pipe, including taking down old and removal, complete all as specified and directed.
All as per item No 3.34 but Gun metal gate valve 25mm bore complete all as specified and directed .
All as per item No 3.34 but Gun metal gate valve 40mm bore complete all as specified and directed .
All as per item No 3.34 but Gun metal gate valve 50mm bore complete all as specified and directed .
Supply and fix, cast iron sluice valve for 100mm dia bore pipe, with flanged and drilled ends, any pattern, heavy duty, class PN 1.6, ISI marked & of specified make, Cast iron wheel, including joints and jointing materials as rubber washers/gaskets, bolts and nuts, etc, also taking down old and removal, complete all as specified and directed.
All as per item No 3.38 but 150mm bore complete all as specified and directed by Engineer-in-charge.
All as per item No 3.38 but 200mm bore complete all as specified and directed by Engineer-in-charge.
Material and labour, run lead joint for 100mm dia bore CI pipe and fittings, complete all as specified and directed.
Material and labour, run lead joint for 150mm dia bore CI pipe and fittings, complete all as specified and directed.
Material and labour, run lead joint for 200mm dia bore CI pipe and fittings, complete all as specified and directed.
Draining out water completely from RCC over head Reservoir of capacity 50000 gallons in two parts at 50 feet staging and material and labour for desludging of RCC over head reservoir manually ,cleaning the inner portion of RCC tank by brooming with fine brush ,removing complete silt,sludge,vegetations unwanted foreign materials etc manually under artificial pressure from the tank, filling of cracks with pidilite /Dr fixit non shrink compound suitable to potable water to make tank leak proof. Plastering in CM 1:4, 15mm thick to the internal & external surfaces of the damaged portions of the reservoir and staging and applying two coats of cement base paint to the external surface of the reservoir and staging. Painting with black synthetic enamel paint to the all CI pipe line and other MS work etc fitted with the RCC OH reservoir and staging including making a block in Synthetic enamel paint 1mtr in height black base and writing in 100mmx100mm size letters with white synthetic enamel paint, DATE OF TANK CLEANING complete all as specified and as directed.
Excavation & earth work in any type soil for locating the leakage in existing cast iron water mains any type/size 100mm bore (including all fittings) and rectifying the leakage complete all as specified and directed. Note: Any CI fittings/specials, joint & jointing material etc required for the rectification of leakage shall be measured & paid for separately.
All as per Serial Item No 3.45 here-in-before but CI pipe of 150mm bore complete all as specified and directed.
All as per Serial Item No 3.45 here-in-before but GI pipe up to 25mm bore complete all as specified and directed.
All as per Serial Item No 3.45 here-in-before but GI pipe up to 40/50mm bore complete all as specified and directed. Note for item No. 3.45 to 3.48:- Cost of all GI fittings/special required deemed to be included in the rate quoted and nothing extra shall be admissible on this account.
Collection of the water sample from the borewell duly sealed by the Engineer- in - Charge, carrying to the PHE UT Chandigarh/ Govt lab for testing, depositing it and collecting the test report from the lab & deposited with the department complete all as specified and directed.
Supply and fix fully automatic star - Delta Starter suitable for 30HP Submersible motor 415 volts 50 HZ AC including over load relay, range and power contactor, single phase preventer with volt meter and ammeter and MCB TP etc complete all accessories pre-wired /connected with suitable size copper conductor. complete all as specified and directed.
Supply only DOL starter in sheet steel enclosure suitable for 5 HP monoblock centrifugal pump set 415 volt 50 Hz complete including Power contactor, over load relay range 7 to 10 Amp, single phase preventer, pre-wired, complete all as specified and directed.
AIR CONDITIONING
Material and labour for servicing to Split type AC operated on 240 volts single phase AC electric supply of any make/type capacity 1.5/2.0 Ton, both internal / external units of AC, dry cleaning with blower / vacuum cleaner, washing with soap solution and cleaning with water pressure through jet, make it fully serviceable , complete all as specified and as directed by Engineer-in-Charge.
All as per item No 1.00 here - in- before but for window type AC unit of any make /model and capacity 1.5 ton, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing sealed unit Hermatic Compressor operated on "R-22 refrigerant" Company replaced only suitable for split/window type AC 1.5 Ton capacity of existing make and model duly filled of gas, compressor oil including taking out old/US compressor complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing sealed unit Rotary Compressor operated on "R-22 refrigerant" Company replaced only suitable for split / window type AC 1.5 Ton capacity of existing make and model duly filled of gas, compressor oil including taking out old US compressor complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing the following spares/parts for split /window type AC unit including taking out old /US spares/parts complete all as specified and as directed.
Copper tube 5/8 inch bore including necessary insulation.
Copper tube 3/8 inch bore including necessary insulation.
Blade only for blower outdoor motor split unit any type.
Blade only for blower indoor motor split unit any type.
Blade only for blower window type unit any type.
Starting relay Make:Renutral/Indfoss/Denfoss
Over Load Protector Make:Renutral/Indfoss/Denfoss
Thermostat switch Make:Renutral/Indfoss/Denfoss
Starting Capacitor 100-120MFD any capacity Make:Epcos/Usha/Tesla
Running Capacitor 36MFD any capacity Make:Epcos/Usha/Tesla
Blower motor for outdoor unit. Make:AUE/Cool Home/Universal
Blower motor for indoor unit. Make:AUE/Cool Home/Universal
Blower motor double shaft for Window AC unit. Make:AUE/Cool Home/Universal
Liquid line strainer
Capacitor 4MFD 230Volts. Make:Epcos/Usha/Tesla
Material and labour for Internal wiring for split unit of any capacity with single core copper conductor FRLS cable as per existing size only complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Internal wiring for window unit of any capacity with single core copper conductor FRLS cable as per existing size only complete all as specified and as directed by Engineer-in-Charge.
Supply & filling/charging of gas refrigerant R-22 to split type AC 1.5 Ton capacity of any make and model including detection of gas leakage, brazing and welding etc., restore the gas pressure and creating vacuum complete all as specified and as directed by Engineer-in-Charge.
All as per item No 23 here in - before but for Window type AC 1.5 Ton cap complete all as specified and as directed
Removal for servicing to Water cooler operated on 240 volts single phase AC electric supply of any make/type 40/80Ltrs or 150Ltrs capacity, dry cleaning with blower / vacuum cleaner, washing with soap solution, under clean water pressure through jet, make it fully serviceable Cleaning of water storage tank, detection of water leakage, brazing / welding to restore the leakage and vice-versa, complete all as specified and as directed by Engineer-in-Charge. Note:- If any minor part/spare is required replacement at site, or any addition / alteration required deemed to be included in quoted unit rate and nothing extra shall be admissible on this account.
Supply and fixing sealed unit Hermatic Compressor Company replaced only suitable for Water Cooler 40/80Ltrs capacity of existing make and model duly filled of gas, compressor oil including taking out old/US compressor complete all as specified and as directed by Engineer-in-Charge.Make:Kirloskar or equivalent as approved by GE.
All as per item No 4.26 here in - before but for Water Cooler 150Ltrs capacity complete all as specified and as directed by Engineer-in-Charge.Make:Kirloskar
Supply and filling/charging of gas refrigerant R-22 for Water Cooler 40/80Ltrs capacity of any make and model including detection of gas leakage, brazing and welding etc., restore the gas pressure and creating vacuum complete all as specified and as directed by Engineer-in-Charge.
All as per item No 28 here in - before but for Water Cooler 150Ltrs capacity complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement the following items of existing make and model suitable for refrigerator 165/320 ltr capacity including taking out old /US spares / parts complete all as specified and as directed by Engineer-in-Charge.
Steel Shelves PVC coated 165 -180Ltrs. capacity
Starting Relay Box 165 - 180Ltrs. capacity. Make:Renutral/Indfoss/Denfoss
Overload Protection Box 165 - 180Ltrs. capacity. Make:Renutral/Indfoss/Denfoss
Running Capacitor 10MFD 230volts.
Thermostat switch any capacity.
Vegetable Tray with glass cover165 - 180Ltrs. capacity.
Rubber door gasket magnetic type 165 - 180Ltrs. capacity.
Crisper tray 165 - 180Ltrs. capacity. .
Pigmy lamp 10watts 230 volts.
Ice Tray PVC
Capillary tubes copper 1/60"
Liquid line stainer
Internal wiring of refrigerator of any capacity
Supply and fixing for replaced to the following items in lieu of provided with new of existing make and model suitable for water cooler any capacity including taking out old /US spares/parts complete all as specified and as directed by Engineer-in-Charge.
Over Load Protector 40/80 Ltrs capacity.Make:Renutral/Indfoss/Denfoss
Liquid line stainer any Capacity.
Blade only for condensor motor any capacity
Starting relay Kit 40/80 Ltrs capacity.Make:Renutral/Indfoss/Denfoss
Thermostat switch any capacity.Make:Renutral/Indfoss/Denfoss
Starting Capacitor 40-60MFD 230Volts.Make:Epcos/Usha/Tesla
Running Capacitor 20MFD 230Volts.Make:Epcos/Usha/Tesla
Condensor motor only
Push Cock CP 15mm.
Magnetic Rubber gasket for top cover any capacity.
PVC Drain pipe 32mm bore not less than 1mtr in length.
Internal wiring of refrigerator/deep freezer/water cooler etc of any capacity
Taking down carefully the following accessories /parts from existing desert cooler in lieu of providing new accessories /parts in desert cooler details as given in below complete all as specified and as directed by Engineer-in-Charge:-
Fan motor 350Watts 230Volts 3Speed copper winding single phase complete. Make: KHAITAN/Crompton/Universal
Submersible type Tulu pump 230Volts single phase 1750LPH at 1.5 mtr head complete Make : KHAITAN/Crompton/Universal
Fan blade only
Switch piano type 5 Amp , single pole 230 volts.
Front girl of M S /PVC complete with slides operation and indicator lamps.
Wood wool pad set of three of best quality including fixed wth bamboo stick any size.
PVC pipe heavy duty 15mm bore ISI Marked.
PVC Distribution Tee, Elbows and other minor items (heavy duty) 15mm bore ISI Marked.E101
Internal wiring of desert cooler of any capacity
Material and labour for providing in replacement MS Sheet tank of 20 SWG for desert cooler complete all as specified and as directed by Engineer-in-Charge. Note – The cost of welding/revieting, finishing, primer (Red Oxide) two coats of spray painting with synthetic enamel paint, inner portion of bottom and sides painted with black Japan bituminous paint shall also be deemed to included under the unit rate of item.
Taking down to desert cooler of any make/capacity carefully without damaging, scraping old paint, completely and painted with 2 coats of synthetic enamel paint over a coat of red oxide primer after filling the cavities of MS Sheet with filler to external surface and inner surface of bottom & sides painted with 2 - coat of black Japan paint completed all as specified and as directed by Engineer-in-Charge. Note : Taking down and re-fixing in the same position after painting work shall be deemed to include in the unit rate of this item.
Material and labour for taking up/down the Split type AC operated on 240 volts single phase AC electric supply of any make/type capacity 1.5/2.0 Ton, both internal / external units of AC, dry cleaning with blower / vacuum cleaner, washing with soap solution and cleaning with water pressure through jet, make it fully serviceable. Transportation to the other location, fixing including necessary hold fastners etc & testing complete all as specified and as directed by Engineer-in-Charge. NOTE:- Any material required to make it fully functional shall be measured & paid separately.
All as per item No 4.70 but AC window type complete all as specified and as directed by Engineer-in-Charge.
Note:- Amount of credit of Rs. 93403.00 for retrieved materials is mentioned in Schedule of Credit Page No 114 to118 of tender documents in pdf form which will be deducted offline while acceptance of tender.
GS Engineers
The Rahul Vig
M/s Friends Engineering Works
POWER TECH ENGINEERS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .