Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.9 LAccepted-AOC | ₹68.9 L Quoted ₹69.5 L | L1 | Accepted-AOC L1 Agency for AOC |
| Sl No | Description | Qty | Unit | THE NEHLA SHRI GOPAL AND SONS COOPERATIVE MULTIPURPOSE SOCIETY LIMITED L1 |
|---|---|---|---|---|
| 1.00 | Providing and fixing waterproof LED rope light (Warm White / Yellow), 6
W per metre, IP65 rated, flexible strip type, approx. 400 lumens per metre with 72 LEDs per metre, suitable for indoor/outdoor decorative lighting, complete with transformer/power source, fixing clips, end-caps, installation and testing, of approved make such as Philips / Havells or equivalent, as per direction of Engineer-in-Charge. | 389 | Rmt. | 184 ₹71,576 |
| 2.00 | Supplying, fixing, testing, and commissioning of 18W Gem Trimless Square Surface Mount Downlight, energy-efficient LED ceiling light fixture suitable for surface mounting without false ceiling, with natural white color temperature 4000K, delivering uniform illumination with optimum brightness and low glare. The fixture shall have a slim, sleek square design with a high lumen output, integrated electronic driver with input voltage 220-240V AC, power factor )0.90, long rated life, and compliant with IS and relevant safety standards. Complete with all accessories, wiring, mounting hardware, and installation as per site requirements and as directed by the Engineer-in-charge.
Make: Reputed brands such as Jaquar / Philips / Havells / Panasonic / Crompton / Bajaj, subject to prior approval by the Engineer-in-Charge. | 46.68 | Each | 1,045 ₹48,780.60 |
| 3.00 | Providing and fixing 15 W LED outdoor long-throw spotlight (warm white), with rugged IP65-rated, powder-coated metal/aluminium housing, adjustable beam direction, suitable for highlighting facades or landscape features: inclusive of durable mounting bracket, connection wiring and testing-of approved make such as Philips, Panasonic, Havells, etc., or equivalent, as per direction of Engineer-in-Charge. | 24.9 | Each | 2,200 ₹54,780 |
| 4.00 | Providing and fixing 50 W LED flood light, IP65 rated and IK07 impact-resistant, rugged die-cast aluminium body for thermal management, emitting approximately 4,500-6,000 lumens (cool white / warm white), with a wide-angle waterproof beam, suitable for outdoor decorative lighting: inclusive of mounting bracket, surge protection = 4 kV, and connection wiring-of approved make such as Philips, Panasonic, Havells, etc., or equivalent, as per direction of Engineer-in-Charge. | 15.56 | Each | 2,750 ₹42,790 |
| 5.00 | Supplying, fixing, testing, and commissioning of 4-Watt Robo Oval 4-Way Up-Down Outdoor LED Light Fixture, warm white (approx. 3000K) colour temperature, with high-quality aluminum housing, IP65 waterproof rating suitable for outdoor wall and step lighting applications. The fixture shall provide uniform illumination in 4 directions (up-down, left-right) with energy-efficient LED modules, durable corrosion-resistant finish, and low maintenance. Complete with all necessary accessories, mounting hardware, weatherproof casing, wiring and connections, complying with relevant IS and IEC standards. | 23.34 | Each | 1,199 ₹27,984.66 |
| 6.00 | Providing, fabrication and installation of English and Hindi letters for Welcome Gate made of Stainless Steel 304 Grade, 1.0 mm thick golden finished sheet, laser-cut to required fonts and sizes as approved by Engineer-in-Charge. The letters shall be fixed on MS frame/structure with necessary welding, drilling, screws, supports, spacers, and adhesives to ensure proper alignment and durability. The text to be displayed shall include in English and Hindi. All complete in all respects as per design, drawings, and directions of Engineer-in-Charge. Letters shall be from reputed make and finished to achieve uniform golden shine.” Payment shall be made on the basis of actual visible surface area (in Sq.ft/Sq.m) of stainless steel letters measured in finished position. The front visible surface area of each letter is measured.Example: A letter “A” of 0.600 Mtr. height × 0.45 Mtr. average width = then total area 0.270 sqm. | 12.14 | Sqm | 13,450 ₹1.6 L |
| 7.00 | Providing and fixing 1.00 mm thick Stainless Steel 304 grade Golden Colour Sheet of approved make and shade, including necessary cutting, bending, curving, welding, grinding, polishing to mirror finish, edge moulding with SS beading/trim wherever required, fixing with stainless steel screws/adhesives/fasteners, complete in all respects including scaffolding, surface preparation and making good the damages etc. as per the direction of Engineer-in-Charge. | 155.6 | Sqm | 3,283 ₹5.1 L |
| 8.00 | Providing laser cutting of stainless steel of required thickness, as per approved pattern/design, including programming, setting, precision cutting with CNC laser cutting machine, smooth finishing of edges, handling, loading/unloading, complete as per drawings and instructions of Engineer-in-Charge. | 155.6 | Sqm | 335 ₹52,126 |
Tender Value
₹59.9 L
EMD Value
₹1.4 L
Closing Date
12 Feb 2026, 5:00 pmClosed
Rahul Poonia
Municipal Council Gohana
Construction of Kashyap Welcome Gate at Panipat Road in Ward No. 10 Municipal Council Gohana.
2026_HRY_500906_1
202600D28793 35B0 4980 A173 5F8893485D83320ULB
Open Tender
Civil Works
260 days
Gohana
Construction of Kashyap Welcome Gate at Panipat Road in Ward No. 10 Municipal Council Gohana
2 documents required · 2 mandatory
₹5,000
Yes
₹1.4 L
Yes
28 Apr 2026
5 Feb 2026
13 Feb 2026
5 Feb 2026
12 Feb 2026
5 Feb 2026
Providing and fixing waterproof LED rope light (Warm White / Yellow), 6 W per metre, IP65 rated, flexible strip type, approx. 400 lumens per metre with 72 LEDs per metre, suitable for indoor/outdoor decorative lighting, complete with transformer/power source, fixing clips, end-caps, installation and testing, of approved make such as Philips / Havells or equivalent, as per direction of Engineer-in-Charge.
Supplying, fixing, testing, and commissioning of 18W Gem Trimless Square Surface Mount Downlight, energy-efficient LED ceiling light fixture suitable for surface mounting without false ceiling, with natural white color temperature 4000K, delivering uniform illumination with optimum brightness and low glare. The fixture shall have a slim, sleek square design with a high lumen output, integrated electronic driver with input voltage 220-240V AC, power factor )0.90, long rated life, and compliant with IS and relevant safety standards. Complete with all accessories, wiring, mounting hardware, and installation as per site requirements and as directed by the Engineer-in-charge. Make: Reputed brands such as Jaquar / Philips / Havells / Panasonic / Crompton / Bajaj, subject to prior approval by the Engineer-in-Charge.
Providing and fixing 15 W LED outdoor long-throw spotlight (warm white), with rugged IP65-rated, powder-coated metal/aluminium housing, adjustable beam direction, suitable for highlighting facades or landscape features: inclusive of durable mounting bracket, connection wiring and testing-of approved make such as Philips, Panasonic, Havells, etc., or equivalent, as per direction of Engineer-in-Charge.
Providing and fixing 50 W LED flood light, IP65 rated and IK07 impact-resistant, rugged die-cast aluminium body for thermal management, emitting approximately 4,500-6,000 lumens (cool white / warm white), with a wide-angle waterproof beam, suitable for outdoor decorative lighting: inclusive of mounting bracket, surge protection = 4 kV, and connection wiring-of approved make such as Philips, Panasonic, Havells, etc., or equivalent, as per direction of Engineer-in-Charge.
Supplying, fixing, testing, and commissioning of 4-Watt Robo Oval 4-Way Up-Down Outdoor LED Light Fixture, warm white (approx. 3000K) colour temperature, with high-quality aluminum housing, IP65 waterproof rating suitable for outdoor wall and step lighting applications. The fixture shall provide uniform illumination in 4 directions (up-down, left-right) with energy-efficient LED modules, durable corrosion-resistant finish, and low maintenance. Complete with all necessary accessories, mounting hardware, weatherproof casing, wiring and connections, complying with relevant IS and IEC standards.
Providing, fabrication and installation of English and Hindi letters for Welcome Gate made of Stainless Steel 304 Grade, 1.0 mm thick golden finished sheet, laser-cut to required fonts and sizes as approved by Engineer-in-Charge. The letters shall be fixed on MS frame/structure with necessary welding, drilling, screws, supports, spacers, and adhesives to ensure proper alignment and durability. The text to be displayed shall include in English and Hindi. All complete in all respects as per design, drawings, and directions of Engineer-in-Charge. Letters shall be from reputed make and finished to achieve uniform golden shine.” Payment shall be made on the basis of actual visible surface area (in Sq.ft/Sq.m) of stainless steel letters measured in finished position. The front visible surface area of each letter is measured.Example: A letter “A” of 0.600 Mtr. height × 0.45 Mtr. average width = then total area 0.270 sqm.
Providing and fixing 1.00 mm thick Stainless Steel 304 grade Golden Colour Sheet of approved make and shade, including necessary cutting, bending, curving, welding, grinding, polishing to mirror finish, edge moulding with SS beading/trim wherever required, fixing with stainless steel screws/adhesives/fasteners, complete in all respects including scaffolding, surface preparation and making good the damages etc. as per the direction of Engineer-in-Charge.
Providing laser cutting of stainless steel of required thickness, as per approved pattern/design, including programming, setting, precision cutting with CNC laser cutting machine, smooth finishing of edges, handling, loading/unloading, complete as per drawings and instructions of Engineer-in-Charge.
Percentage BoQ
BoQ_Ver3.0
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
[10.50.1]Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. [Through Rate]
[10.51]Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. [Through Rate]
[11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) [Through Rate]
[13.29.2]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works [Through Rate]
[13.41]Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). [Through Rate]
[23.22.1.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.1. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. Double pole MCCB 16 to 63 Amp, 25 Ka [Through Rate]
[23.22.1.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.2. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. Double pole MCCB 100 to 125 Amp, 25 Ka [Through Rate]
[23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP [Through Rate]
[23.22.2.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.2. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 250 A FP [Through Rate]
[23.22.3.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 3.1. Supply and erection of sheet steel enclosures 1pole/2 pole/4 pole on wall/on existing pedestal complete as required. SP enclosure suitable for single pole MCB [Through Rate]
[23.22.3.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 3.2. Supply and erection of sheet steel enclosures 1pole/2 pole/4 pole on wall/on existing pedestal complete as required. S.P.N. or DP enclosure suitable for DP MCB [Through Rate]
[23.22.3.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 3.3. Supply and erection of sheet steel enclosures 1pole/2 pole/4 pole on wall/on existing pedestal complete as required. TPN enclosure suitable for TP , TPN or FP MCB [Through Rate]
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate]
[23.22.5.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.2. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Single Pole [Through Rate]
[23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE [Through Rate]
[23.22.5.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.4. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Double pole [Through Rate]
[23.22.5.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.5. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp MCBs TRIPLE POLE [Through Rate]
[23.22.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 7. Supply and erection of blanking sheet in existing distribution board. [Through Rate]
[23.22.8.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.1. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 63 amp 415 volts [Through Rate]
[23.23.1.1]MISCELLANEOUS 1.1. Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc. at both ends (Up to length of one metre):- Size 15 mm dia [Through Rate]
[23.23.1.2]MISCELLANEOUS 1.2. Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc. at both ends (Up to length of one metre):- Size 20 mm dia [Through Rate]
[23.23.1.3]MISCELLANEOUS 1.3. Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc. at both ends (Up to length of one metre):- Size 25 mm dia [Through Rate]
[23.23.2.1]MISCELLANEOUS 2.1. Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required. 15 mm dia [Through Rate]
[23.23.2.2]MISCELLANEOUS 2.2. Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required. 20 mm dia [Through Rate]
[23.3.6.1]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
[23.3.6.10]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.10. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 3 run of Size 2.50 Sqmm(1.1.80mm) [Through Rate]
[23.3.6.2]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) [Through Rate]
[23.3.6.3]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate]
[23.3.6.4]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.4. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm) [Through Rate]
[23.3.6.5]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) [Through Rate]
[23.3.6.6]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.6. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
[23.3.6.7]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.7. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 2.50 Sqmm(1.1.80mm) [Through Rate]
[23.3.6.8]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.8. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 4 Sqmm(1/2.24mm) [Through Rate]
[23.3.6.9]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.9. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 3 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
[23.4.1.2]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.2. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B [Through Rate]
[23.4.2.2]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 2.2. Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B [Through Rate]
[23.4.3.2]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 3.2. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group B [Through Rate]
[23.4.4.2]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.2. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group B [Through Rate]
[23.4.5.2]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.2. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B [Through Rate]
[23.7.6.1]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.1. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 20 mm dia. [Through Rate]
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
[23.7.6.3]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.3. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 32 mm dia. [Through Rate]
[23.7.6.4]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 40 mm dia. [Through Rate]
[24.1.16]EARTHING AND LIGHTENING ARRESTOR 16. Supply and erection of 25mm dia 1.5 metre long lightning GI. tube rod tapered into a point at the top with 16cm x 16cm x 3mm thick G.I. base plate and necessary nuts and bolts with washers. [Through Rate]
[24.1.17]EARTHING AND LIGHTENING ARRESTOR 17. Providing and fixing testing joints made of 20mm x 3mm thick G.I. strips 125 mm long with 4 nos. G.I. bolts and nuts with washers complete. [Through Rate]
[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. [Through Rate]
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate]
[24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. [Through Rate]
[3.1.2]By Mechanical Transport including loading, unloading and stacking 2. Earth [Beyond 5km up to 10km per KM]
[4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate]
[4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. [Through Rate]
[6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) [Through Rate]
[6.25.1]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 1. All works up to plinth level [Through Rate]
[6.25.2]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 2. All works above plinth level up to floor IV level [Through Rate]
[6.30.1]Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete [Through Rate]
[6.30.2]Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. [Through Rate]
[6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate]
[6.30.6]Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts [Through Rate]
[6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more [Through Rate]
[6.34.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. [Through Rate]
[7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate]
[7.28.2]Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand) [Through Rate]
[8.9.2.1]Stone work (machine cut edges) for wall lining etc. (veneer work) up to 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 2.1. Red sand stone - Exposed face machine cut and table rubbed with rough backing.70 mm thick [Through Rate]
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
BOQ_579524.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid