Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 LAdmitted-Finance BHAGWATI NAGAR JAMMU | ₹2.2 L | L1 | Admitted-Finance |
| 2 | L2₹2.2 LAdmitted-Finance BHAGWATI NAGAR JAMMU | ₹2.2 L | L2 | Admitted-Finance |
| 3 | L3₹2.2 LAdmitted-Finance 25 PRATAP COMPLEX GULAB SINGH MARG JAMMU | ₹2.2 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | NATIONAL ELECTRO-MECH COMPANY L3 | PERFECT ELECTRICAL WORKS L2 | BEE AAR ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Repair of 33 TR (2X16.5 TR) Package Air conditioning unit and allied works installed at Recovery ward of New Emergency of GMCH, Jammu by way of disconnecting of electrical connections. The job includes replacement of damaged Copper cable 4 core 2.5 sq mm approximately-20 mtrs between inner and outer unit. The job further includes replacement of leaking/damaged copper pipe 1.0 mm by providing and fixing of new copper pipe of same dia and then pressure testing of copper piping by Freon mixed with nitrogen at a pressure of 20 kg per sq cm. high side and 10 kg per sq cm low side. The pressure shall be maintained on the system for 72 hours and if there is no pressure drop then the system is vaccumised and eco friendly Refrigerant gas 40 Kg approximately is charged in the unit. The job further includes replacement of damaged expansion valve by providing and fitting of new as per sample and then making electrical connections testing of Package unit on no load and on full load. Complete job includes cost of materiai, labour, transportation and all types of taxes etc. | 1 | job | 0.02 ₹1.4 L | 0.02 ₹1.4 L | 0.02 ₹1.4 L |
| 2.00 | Repairing the damaged 75 KVA oil cooled automatic voltage controlled Servo stabilizer installed for Recovery ward of New emergency block of GMCH Jammu by way of disconnecting of all incoming and outgoing electric connections and draining out all the T- OIL and storing it properly in barrels. Job includes dragging out the Servo manually/mechanically using tools & tackles. Dismantling of Stabilizer by way of unfastening Nuts & Bolts of top cover and extracting out the damaged coils along with core by means of chain pulley block and tripod stand. Job includes shifting of Servo assembly to workshop and then replacement of damaged dimmer coils (variac assembly) 01No’s with new ones, repairing to other dimmer coils by way of polishing with emery paper and proper varnishing, replacement of control cards 03 No’s, moving arms 02 No’s with carbon holders and carbon brushes with holder 32 No’s, voltmeter 02 No’s and phase indicator set and replacement of panel wiring and internal wirings etc and lubricating of all the gears of servo motors. The job also includes cleaning, servicing of oil chamber by checking of leakage and plugging it by way of welding and assembling of stabilizer. Job includes shifting back of Servo assembly to the site and dragging the servo to its installed position & then Topping up with stored T oil from top layer of barrel and then with fresh T-OIL 100 ltrs so that all coils are fully immersed in the oil. Making connections of voltage stabilizers input and output side by connecting the cable. Job also includes thimbling to end terminals by crimping process and charging the stabilizer on no load for 6 hours, then testing the stabilizer on full load. The job includes cost of material, labour charges, hire charges of tools and tackles and all the taxes as applicable | 1 | job | 0.02 ₹85,505 | 0.02 ₹84,770 | 0.02 ₹84,280 |
Tender Value
₹2.3 L
EMD Value
₹5,000
Closing Date
17 Feb 2026, 4:00 pmClosed
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
Repair of 33 TR 2X16.5 TR Package Air conditioning unit and allied works installed at Recovery ward of New Emergency of GMCH, Jammu
2026_PWDJK_302680_1
MHDJ/e-NIT 353 of 2025-26
Open Tender
Repair and Maintenance Services
10 days
GMCH JAMMU
as per e nit
2 documents required · 2 mandatory
₹200
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
₹5,000
17 Apr 2026
9 Feb 2026
18 Feb 2026
9 Feb 2026
17 Feb 2026
10 Feb 2026
9 Feb 2026 - 17 Feb 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division GMCH Jammu.
Repair of 33 TR (2X16.5 TR) Package Air conditioning unit and allied works installed at Recovery ward of New Emergency of GMCH, Jammu
MHDJ/e-NIT 353 of 2025-26 Dated: 09.02.2026 Due : 17.02.2026
Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate including GST to be quoted by the bidder Rs. P Currency Convertion against each Item Quoted Currency in INR / Other Currency Rebate on old parts in Percentage (%) if any Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Net Cost of item Rs. P
1 Repair of 33 TR (2X16.5 TR) Package Air conditioning unit and allied works installed at Recovery ward of New Emergency of GMCH, Jammu by way of disconnecting of electrical connections. The job includes replacement of damaged Copper cable 4 core 2.5 sq mm approximately-20 mtrs between inner and outer unit. The job further includes replacement of leaking/damaged copper pipe 1.0 mm by providing and fixing of new copper pipe of same dia and then pressure testing of copper piping by Freon mixed with nitrogen at a pressure of 20 kg per sq cm. high side and 10 kg per sq cm low side. The pressure shall be maintained on the system for 72 hours and if there is no pressure drop then the system is vaccumised and eco friendly Refrigerant gas 40 Kg approximately is charged in the unit. The job further includes replacement of damaged expansion valve by providing and fitting of new as per sample and then making electrical connections testing of Package unit on no load and on full load. Complete job includes cost of materiai, labour, transportation and all types of taxes etc. job Excess(+) Full Conversion INR
2 Repairing the damaged 75 KVA oil cooled automatic voltage controlled Servo stabilizer installed for Recovery ward of New emergency block of GMCH Jammu by way of disconnecting of all incoming and outgoing electric connections and draining out all the T- OIL and storing it properly in barrels. Job includes dragging out the Servo manually/mechanically using tools & tackles. Dismantling of Stabilizer by way of unfastening Nuts & Bolts of top cover and extracting out the damaged coils along with core by means of chain pulley block and tripod stand. Job includes shifting of Servo assembly to workshop and then replacement of damaged dimmer coils (variac assembly) 01No’s with new ones, repairing to other dimmer coils by way of polishing with emery paper and proper varnishing, replacement of control cards 03 No’s, moving arms 02 No’s with carbon holders and carbon brushes with holder 32 No’s, voltmeter 02 No’s and phase indicator set and replacement of panel wiring and internal wirings etc and lubricating of all the gears of servo motors. The job also includes cleaning, servicing of oil chamber by checking of leakage and plugging it by way of welding and assembling of stabilizer. Job includes shifting back of Servo assembly to the site and dragging the servo to its installed position & then Topping up with stored T oil from top layer of barrel and then with fresh T-OIL 100 ltrs so that all coils are fully immersed in the oil. Making connections of voltage stabilizers input and output side by connecting the cable. Job also includes thimbling to end terminals by crimping process and charging the stabilizer on no load for 6 hours, then testing the stabilizer on full load. The job includes cost of material, labour charges, hire charges of tools and tackles and all the taxes as applicable job Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
techsummary_982425.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
BOQ_982425.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid