| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.2 LAccepted-AOC | 1 | Accepted-AOC ACCEPTED BEING THE LOWEST TENDERER | |
| 2 | 2₹6.0 L+₹80,898.10 (15.7%)Rejected-Finance D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹6.2 L+₹1.0 L (19.9%)Rejected-Finance | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹6.9 L+₹1.7 L (33.0%)Rejected-Finance | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹6.6 L
EMD Value
₹13,200
Closing Date
12 May 2020, 6:00 pmClosed
AGE I CG VIZAG
AGE I CG Military Engineer Services CGWO Building C o Fleet Mail Office Visakhapatnam 530 014 Ph 0891 2743118
PROVISION OF AIR CONDITIONERS AT ANTEE ROOM AT CG OFFICERS MESS AND FOR CCTV EQUIPMENT AT MAIN DUTY ROOM AT ICGS VISAKHAPATNAM UNDER AGE I CG VIZAG
2020_MES_333024_2
AGE(I)CG/VIZ/TOKEN 41 OF 2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
VISAKHAPATNAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I CG VIZAG
₹13,200
Yes
8 Jul 2020
15 Apr 2020
14 May 2020
15 Apr 2020
12 May 2020
20 Apr 2020
Amount
Supply, Installation, connecting, testing and commissioning split type AC of capacity 1.5 TR ( 4500 KCal / hr) Inverter type 5 Star single phase 230 Volt AC with hermetically sealed rotary type compressor, Air flow not less than 425 CFM, Fan speed in three step, high quality powder coated / high quality paint finish, dust and bacteria filter, wireless remote with LCD display,refrigerant as per current industry standard, complete all as specified and as directed and comprising of following :- (a) Supply & fixing refrigerant pipe, refrigerant gas, copper tubing for suction & discharge of suitable size duly insulated & protected by suitable size of flexible PVC conduit with control valve & safety accessories all as directed by Engineer-in-Charge. (b) Supply & fixing wiring for evaporator and condensing unit with suitable size of copper wire in PVC conduit all as directed by Engineer-in-Charge. (c) Refrigerant pipe discharge suction and liquid line copper tubing of suitable size (3/8” & 5/8”) with insulated and properly protected by suitable size of PVC flexible conduit as specified by manufacturer with control valve and safety accessories refrigerant pipe not exceeding 10 meter complete all as directed by Engineer-in-Charge. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc. all as directed by Engineer-in-Charge. (e) Connection of evaporating and condensing unit with suitable size of copper wire PVC insulated all as directed by Engineer-in-Charge. (f) Requisite gas for charging alongwith copper tubing and insulating materials all as directed by Engineer-in-Charge. (g) Out door unit to be fixed on wall/floor with support of MS stand duly painted with enamel paint over a coat of primer. Make : LG / HITACHI / BLUE STAR or equivalent in any of the makes as per list of makes specified in Particular Specifications.
Supply,Installation,connecting, testing and commissioning split type AC of capacity 2.0 TR ( 6000K Cal /hr) Inverter type 5 Star single phase 230 Volt AC with hermetically sealed rotay type compressure,Air flow not less than 425 CFM, Fan speed in three step,high quality powder coated /high quality paint finish, dust and bacteria filter, wireless remote with LCD display,refregerant as per current industry standard, complete all as specified & comprising of following :- (a) Supply & fixing refrigerant pipe, refrigerant gas, copper tubing for suction & discharge of suitable size duly insulated & protected by suitable size of flexible PVC conduit with control valve & safety accessories all as directed. (b) Supply & fixing wiring for evaporator and condensing unit with suitable size of copper wire in PVC conduit. (c) Refrigerant pipe discharge suction and liquid line copper tubing of suitable size (3/8” & 5/8”) with insulated and properly protected by suitable size of PVC flexible conduit as specified by manufacturer with control valve and safety accessories refrigerant pipe not exceeding 10 m complete. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc . (e) Connection of evaporating and condensing unit with suitable size of copper wire PVC insulated. (f) Requisite gas for charging alongwith copper tubing and insulating materials. (g) out door unit to be fixed on wall/floor with support of MS stand duly painted on enalmelled paint over a coat of primer. Make : LG / HITACHI / BLUE STAR or equivalent in any of the makes as per list of makes specified in Particular Specifications.
Supply and fixing Modular AC Box, plug and play, all in one type, Single pole and neutral box with one single pole MCB 25 Amp 230 Volts complete all as specified at site. Make : Havells Cat No DHDDCDP0252025030 or equivalent in any of the makes as per list of makes specified in Particular Specifications.
M&L for Sub Main wiring with two single core 4 Sqmm PVC insulated FR multistranded flexible copper conductor cable 660/1100 volts grade drawn in, through flexible non metallic PVC Concealed conduit/Surface conduit with and including PVC insulated 2.5 Sqmm single core single strand copper conductor as continuous earth wire in green colour connected to common earth dolly complete all as specified and as directed.
S&F Voltage stabilizer, wall mounted, automatic transformer for low & high voltage correction equipped with electronic transistorized relay suitable for correction on single phase 50 cycles AC supply complete with voltmeter and designed for input voltage of 110 V to 280 V & output voltage stabilized between 215 V to 240 V of capacity 20 Amp (5 KVA). Make: V-guard or equivalent in any of the makes as per list of makes specified in Particular Specifications.
Supply, laying and testing of 10 sq mm 2 Core. LT UG cable XLPE with aluminum conductor, Screened bedded multistranded 1100 volts grade in Galvanised steel strip or wire armored, heavy duty electric power cables with stranded aluminium conductor complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for taking out/laying cable and getting out, in Soft/Loose Soil complete all as specified and as directed.
Returning, filling including spreading leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and as directed.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Supply spreading in trenches fine dry crushed stone sand for cable protection and punning down gently by hand complete all as specified and as directed.
Supply and lay cable cover for LT Cable Class LV,type 1 , flat size 250 mm x 150 mm x 40 mm complete all as specified and as directed.
Supplying & Laying, connecting and testing GI Pipe 40 mm bore light grade including necessary fittings for Cable protection all as specified and as directed.
S&F double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and as directed. Make : Legrand/ Schiender/Siemens or equivalent in any of the makes as per list of makes specified in Particular Specifications.
S&F testing and commissioning of MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having B-curve characteristics connected with suitable lugs complete all as specified and as directed. Make : Legrand/ Schiender/Siemens or equivalent in any of the makes as per list of makes specified in Particular Specifications.
S&F testing and commissioning of MCB SPN 240 volt 40 Amp 10 KA capacity having B-curve characteristics connected with suitable lugs complete all as specified and as directed. Make : Legrand/ Schiender/Siemens or equivalent in any of the makes as per list of makes specified in Particular Specifications.
ANAND ENTERPRISES AND ENGINEERS
LAKSHMI SAI CONSTRUCTIONS
pavantejaklimmaat enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .