| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹8.6 LAccepted-AOC | L-1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L-2₹9.0 L+₹39,704 (4.61%)Rejected-Finance 94 D POCKET J AND K DILSHAD GARDEN DELHI DELHI 110095 UDYAM DL 02 0018675 07AHCPD1811D1Z7 B R | SHAHDARA | DELHI | 110095 | L-2 | Rejected-Finance NOT THE LOWEST BIDDER | |
| 3 | L-3₹9.0 L+₹43,571 (5.06%)Rejected-Finance | L-3 | Rejected-Finance NOT THE LOWEST BIDDER | |
| 4 | L-4₹9.2 L+₹57,154 (6.64%)Rejected-Finance | L-4 | Rejected-Finance NOT THE LOWEST BIDDER | |
| 5 | L-5₹9.6 L+₹1.0 L (11.9%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L-5 | Rejected-Finance NOT THE LOWEST BIDDER |
Tender Value
₹9.2 L
Closing Date
23 Aug 2021, 6:00 pmClosed
AGME(E)-II, IMU
ROOM NO. 148, 1ST FLOOR, C BLOCK, R G BHAWAN, NEW DELHI
Annual Maintenance Contract of Fire Alarm and Detection System at Operational Office Complex, New Hanger Building, ASM Directorate and ER Building at Safdarjung Airport, New Delhi for Two years (2021-22, 2022-23)
2021_AAI_84887_1
AAI/IMU/AGME(E)II/ENIT01/21-22
Open Tender
Fire & Safety
Item Rate
730 days
SAFDARJUNG AIRPORT NEW DELHI
Please refer Tender documents.
17 documents required · 17 mandatory
₹1,120
Exempted
22 Sept 2021
13 Aug 2021
25 Aug 2021
14 Aug 2021
23 Aug 2021
14 Aug 2021
14 Aug 2021 - 19 Aug 2021
Amount
Maintenance of Conventional & Addressable fire alarm and detection system at following locations involving repairs & maintenance, faults finding, attending breakdowns and taking rectification action, ensuring serviceability, satifactory working condition of the system, including providing minor consumables, tools & tackle, carrying out preventive maintenance on daily, weekly, fortnightly, monthly, quarterly basis and maintenance of records/documentation etc. on all days by deploying adequate skilled and unskilled manpower as per special conditions of contract complete as required. Locations: (i) Operational Office Complex (Agni, 8 Zone Fire Alarm Panel with connected detectors, MCPs, RI, hooters, wiring and all other associated devices). (ii) New Hanger Building (Firelite-Honeywell, 04 loop Fire Alarm Panel with connected detectors, MCPs, RI, hooters, wiring and all other associated devices). (iii) ASM Directorate (Simplex, 01 loop Fire Alarm Panel with connected detectors, MCPs, RI, hooters, wiring and all other associated devices). (iv) ER Building (Morley IAS-Honeywell 02 loop Fire Alarm Panel with connected detectors, MCPs, RI, hooters, wiring and all other associated devices).
Supplying of following Materials/ Spares as per list of approved makes in compatible with panels located at above sites as and when required
Intellegent microprocessor intellegent soft addressable smoke detectors; (make: Honeywell Firelite)
Intellegent microprocessor intellegent soft addressable smoke detectors; (make: Honeywell Morley)
Addressable type multi criteria sensor type detector (Make -Honeywell Firelite)
Addressable type multi criteria sensor detector (Make -Honeywell Morley)
Adressable type Manual Call Point; (make: Honeywell)
Adressable type hooter/ sounder; (make: Honeywell)
Addresssable type Smoke Detector (make: Simplex)
Conventional type Smoke Detector (Make: Apollo)
Conventional Manual Call Point (Make: Agni)
Conventional type Hooter/ sounder (Make: Agni)
Conventional type Response Indicator (make: Agni)
Zonal card for 8 zones conventional fire Control Panel (Make: Agni)
Loop card for Addressable Panel (Firelite-Honeywell, 04 loop panel / Simplex, 01 loop panel/ Morley IAS-Honeywell 2 loop Panel )
Motherboard for Agni 8 Zone Panel
7AH, 12V maintenance free battery for fire Alarm panels
Supplying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supplying 1.5 sqmm dia FRLS PVC insulated copper conductor, single core cable
Supplying and fixing of following sizes of ISI marked steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supply, Installation, Testing,commissioning and programming of of 2 loop Morley IAS Fire Alarm Panel compatible to existing detectors and accessories at ER Building, Safdarjung airport, complete etc. as required.
Laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable EPR insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete saddles, screws as required on surface or in recess.
Visit of Specialized Authorized Engineer for any of the (Make: - Firelite-Honeywell 4 loop panel/ Morley IAS 2 loop panel/ Simplex One loop Panel) addressable fire detection alarm panels (both hardaware & software) with connected accessories to attend critical complaints or breakdowns on need basis which also includes, programming of devices (if required) and reporting faults/ deficiencies to E-I-C, and submitting the report to E-I-C.
Visit of Specialized Authorized Engineer for Agni make 8 Zone Conventional fire detection and alarm panel (both hardaware & software) with connected accessories to attend critical complaints or breakdowns on need basis which also includes, programming of devices (if required) and reporting faults/ deficiencies to E-I-C, and submitting the report to E-I-C.
NATIONAL SAFETY ENGINEERS
COSMOS SYSTEMS
PRUDENT EPC PRIVATE LIMITED
Manish Electricals
REIMER TECHNOLOGIES PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .