Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
31 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE YOL
HQ CWE YOL CANTT
PROVISION OF B/R WORKS AND CERTAIN E/M ALLIED SERVICES UNDER GE (KH) YOL
2021_MES_492565_1
CWE-Y/67/2021-22
Open Tender
Civil Works
Item Rate
550 days
YOL
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE (KH) YOL
₹56,000
Yes
10 Feb 2022
4 Dec 2021
8 Jan 2022
4 Dec 2021
31 Dec 2021
18 Dec 2021
60 days
Amount
Surface excavation not exceeding 30cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed.
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.
Hard core of broken stone or boulders of gauge not exc 63 mm deposited ,spread and leveled in layer not exc 15 cm thick complete all as specified and directed.
PCC 1:5:10 (nominal mix) type E-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
PCC 1:2:4 (nominal mix) type B-2 (using 40mm graded crushed stone aggregates) as in surface channel and drains complete all as specified and directed.
Brick work with old size fly ash bricks, class 7.5, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:6 all as specified & directed.
Rendering cement plaster 15mm thick in cement mortar 1:6 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.
Rendering cement plaster 15mm thick in cement mortar 1:4 on stone masonry or surface other than fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.
Plain cement concrete 1:2:4 ( nominal mix ) type B-0 (using 12.5mm graded crushed stone aggregates) as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar ands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork where required complete all as specified and directed.
Plain cement concrete 1:2:4 ( nominal mix ) type B-1 (using 20 mm graded crushed stone aggregates) as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar ands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork where required complete all as specified and directed.
100 mm thick, PCC 1:2:4, type B-2 (using 40 mm graded crushed stone aggregates) as in floor finish, surface finished even and smooth without using extra cement complete all as specified and directed.
100mm thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in sub base complete all as specified and directed. .
Plain cement concrete 1:3:6, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 50mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen and two parts of heated coarse sand (by volume), all as specified. Note:- The unit rate include for use of form work (straight or curved).
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 50mm thick sand cushioning, joints of tiles filled with dry sand and compacted with mechanical vibrator over and including 75mm thick PCC 1:4:8 (Nominal Mix) type D-2, using 40mm graded crushed stone aggregate complete all as specified and directed.
Machine cut kota stone slab flooring 20-25 mm thick of size not less than 550 mm X 550 mm as per sample kept in GE’s office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, as in floor etc, laid over and including 15mm screed layer in cement mortar 1:4 including cutting, rubbing, grinding and polishing to achieve mirror finish complete, all as specified.
Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed.
1.6mm thick mild steel plain black sheet in wall cladding ,steel gates and similar works ,cut to size ,holes punched, including round headed screws, clout nails or rivets and fixed to steel framing with plain 40mm lap joints with riveted or welded seams including bending or turning up, mitred angles etc as required all as specified and directed.
Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and as directed.
Rolled mild steel work as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to grade Fe 410 -W (Gde-E- 250) quality-A, complete all as specified and as directed.
Framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes framed guard bars including cutting, drilling, welding etc confirming to Fe-290 Gde E-165 all as specified and directed.
Welded steel wire fabric weight exceeding 4 Kg per Sqm, supplied and fixed complete to wood or steel members all as specified and directed.
Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc confirming to Fe-290 Gde E-165 all as specified and directed.
Expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members , weight of metal exc 4kg per sqm ,complete all as specified and as directed.
Preparation of steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Flame proof point wiring in and including concealed ERW rigid steel conduit (metallic) not less than 19mm dia with all MS conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc; using stranded copper conductor cable of size 1.5 Sqmm PVC insulated unsheathed FRLS (Multistrand) cable including PVC insulated unsheathed 1.5 Sqmm copper multistranded conductor FLRS as earth wire (green colour) connected to common earth dolly for one light point or one fan point or 5 Amp socket controlled by one way switch 5 Amp complete all as specified and directed.
Flame proof point wiring in and including concealed ERW rigid steel conduit (metallic) not less than 19mm dia with all MS conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc; using stranded copper conductor cable of size 2.5 Sqmm PVC insulated unsheathed FRLS (Multistrand) cable including PVC insulated unsheathed 2.5 Sqmm copper multistranded conductor FLRS as earth wire (green colour) connected to common earth dolly for one 15 Amp socket point controlled by one way switch 15 Amp complete all as specified and directed.
Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V, all as specified.
Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25A, 250V, 2P+earth all as specified.
Flame proof LED light fitting 1 x 16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as requried at site and directed.
LED flame proof bulk head fitting 30 Watt, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass including fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as requried at site and directed.
Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC, complete all as specified and directed. Note:- Earth work & excavation and PCC shall be measured and paid under respective Items of BOQ.
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
MCB SPN 40 Amp, 240 Volts, 10 KA including providing thimbles for cables all as specified.
MCB SP 6 to 32 Amp, 240 Volts, 10 KA including providing thimbles for cables all as specified.
Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 12 way, double door, 240 volts with 200 Amp rated copper bus bar completed all as specified.
Flame proof sub main wiring with four single core PVC insulated cable 1100 volts grade with copper stranded FRLS conductor of size 25Sqmm (4 single run) with one continuous FRLS copper earthing lead wire of size 16 Sqmm and drawn into and including concealed ERW rigid steel conduit (metallic) of suitable dia with all MS conduit accessories/ fittings such as flame proof junction boxes (1 to 4 way), bends, tee, elbow etc; cutting chases, making good in cement mortar (1:3), finishing surfaces to match with existing and connected to common earth dolly complete and as directed. Note :- Four run (each run of 1 RM) of 25 sqmm copper conductor and one RM of earth wire of 16 Sqmm, shall be measured as one RM).
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cms thick, complete all as specified and directed Note: Punned thickness shall be measured.
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick complete all as specified and directed.
GI pipe light grade of size 80 mm dia laid in trenches/ walls including clamps, screws etc, complete all as specified and directed.
GI pipe light grade of size 40 mm dia laid in trenches/ walls including clamps, screws etc, complete all as specified and directed.
XLPE insulated, armoured heavy duty, LT under ground, electric cable with aluminium conductor, 1100 volts grade, cross sectional area 95 Sqmm, 3.5 core laid in trenches, passing through pipe/ ducts/ surface of wall ceiling etc including testing complete all as specified. Note:- Excavation & Earth work, cable cover and sand cushioning shall be measured and paid separetly.
XLPE insulated, armoured heavy duty, LT under ground, electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm, 4 core laid in trenches, passing through pipe/ ducts/ surface of wall ceiling etc including testing complete all as specified. Note:- Excavation & Earth work, cable cover and sand cushioning shall be measured and paid separetly.
Supply, Installing, testing and commissioning voltage stabilizer for automatic operation, three phase naturally oil cooled type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 50 KVA consist of following specification:- (a) Rated frequency 50 Hz. (b) Conforming to BIS 9815 Part-I 1994( reaffirmed 2014). (c) No load losses less than 1.5% (d) Outdoor type IP 55 protection. (f) Auto/manual control for output voltage setting (by potential meter in auto mode and wish rise/ lower button in manual mode). (g) Inbuilt under voltage/over voltage protection. (h) Overload and short circuit protection. (j) Single phase prevention system. (k) Phase sequence and phase reversal protection (l) By pass arrangement. (m) Input/ output voltage indicators for each phase. (n) MCCB of adequate capacity. (o) First filling of transformer oil to appropriate level and testing on completion.
Supply and fixing aluminium strip of size 25x3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and as directed
Supply and fix MS Junction box outdoor type of size 300mm x 200mm x 100mm made from 16 guage MS Sheet with front openable hinged cover complete with four numbers aluminium bus bar mounted on porcelain insulator including clamps of MS Flat iron 25 x 3 mm with bolts and nuts and one MCB SP upto 10 Amp , 10 KA for on/off street light to fixed on pole complete all as specified and directed. Note : Box to be painted inside and outside with two coats of synthetic enamel paint over a coat red oxide primer.
Supply and fixing of on load change over switch of rating 125 Amps 4 pole (I - O - II) enclosed in sheet metal enclosure having handle front operated for operation including mounting arrangement all as requried at site and directed by Engr - in - Charge.
Supply, installation , Commissiong and Testing of totally enclosed LT panel box (Length = 1.50, Width 0.60 mtr, Height = 1.50 mtr) outddor type, CPRI type tested, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs of appropriate size and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed including taking out exiting LT Panel from site, LT Panel comprising of following
Incoming:- (a) Bus bar chamber comprising 4 Nos copper strip bus bars PVC insulated made of copper strip of size (50 x 10) mm. PVC sheathed with colour coding. "(b) MCCB having current rating 100 Amps with rupturing cap 36 KA , AC 415 Volts, adjustable type, four pole complete with spreader links. (Qty -01 No) " (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Frequency, Power factor, KW, KV etc. (Qty - 01 No). (d) Current transformer of ratio 500 / 5amps, current rating primary up to 500 amps and secondary 5 amps , accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice.(Qty - 1 No Set of three). (e) LED Phase Indicator Lamp (Qty - 01 Set of Three).
Outgoing:- (a) MCCB having current rating 40 Amps with rupturing cap 36 KA , AC 415 Volts, three pole, adjustable type complete with spreader links. (Qty -02 No) (b) MCCB having current rating 25 Amps with rupturing cap 36 KA , AC 415 Volts, three pole, adjustable type complete with spreader links. (Qty -04 Nos) (c ) MCB SPN 16 Amp 10 KA - 02
Supply, install, testing and commissioning of outdoor type factory assembled diesel driven generating set with silent (acoustic) enclosure with fully wired alternator AC for ambient conditionsto give output of 62.5 / 63 KVA (50 KW) continuous rating at power factor 0.8, 415 volts + 2.5% AC 3 phase, 4 wire, 50 Hz + 1 %, 1500 rpm directly coupled with diesel engine water cooled mounted on common base frame placed on & including PCC platform with floor mounted Fuel Tank of adequate capacity with fuel lines, anti vibration pads, standard control & AMF panels and other accessories etc complete all as specified & directed consisting of following :-
(A) Prime Mover (Diesel Engine) :- Adequate capacity diesel engine of standard design consist of direct injection type, turbo charged four stroke, liquid cooled technology conforming to BS 5514 and IS 10000 suitable for prime duty generating set 62.5 KVA / 50 KW of suitable BHP @ 1500 RPM with multi cylinders to drive independently alternator as per site condition after generating and reducing power consumed by accessories, directly coupled through coupling having overload capacity of 10% for one hour in every 12 Hrs continuous running mounted on base frame with following salient features and standard accessories for safe handling & operation of engine as under:-
(a) The gen set should have capacity to run continously in variable load condition for unlimited hours and should also have a 110% load capacity of 01 hour in every 12 hours of operation. (b) Air System - Inlet & Exhaust comprising (i) Dry-type paper element air Cleaner (ii) Restriction Indicator / Vacuum Indicator (iii) Optimised Turbocharger (iv) Intake Manifold (v) Exhaust Manifold (vi) Silencer muffler and (vii) Stainless steel Exhaust Flexible coupling (c) Cooling System comprising (i) Radiator to suit ambient conditions (ii) Cooling system piping (iii) Thermostat (iv) Pressure cap (v) Coolant Inhibitor and (vi) Engine Driven Fan (d) Fuel System comprising (i) Fuel pump -Low pressure type (ii) Injectors (iii) Cartridge paper filters primary and secondary for Fuel (e) Governor :- Engine Electronic Governor for A1 governing of engine speed from No load to full load. (f) Lub Oil System :- (i) Plate Type lub oil cooler (ii) filters-lubrication oil.
(g) Electric Starting system comprising (i) Electrical starter - 12 Volts (ii) Engine driven battery charging alternator (iii) Cut Out and (iv) One No of 12 volts of 150 AH maintenance free battery with suitable connection terminals and leads for proper battery connection (h) Engine Monitoring, Protection and Diagnostics relay suitable to display following (i) Lub oil Pressure (ii) Coolant Temperature (iii) Engine Speed (iv) Hours Run (v) Battery Voltage, Battery charging voltage (vi) Fuel level in percentage, (vii) AC Voltage 3 phase (viii) Current RYB 3 phase (ix) Power Factor (x) Frequency (xi) KVA (xii) Kilowatt and suitable for (i) Start and Stop (ii) Common Shutdown (iii) High coolant temp warning and shutdown (iv) Low tube oil pressure warning and shutdown (v) Low fuel level shutdown (vi) Overspeed shutdown (vii) Alternator Protection (viii) Over voltage (ix) Under voltage (x) Over and under frequency (xi) Over current (j) Engine fitted with low lube oil pressure (LLOP) & high water temperature (HWT) Safety devices and also fitted with requisite temperature and pressure gauges.
(B) ALTERNATOR :- Self excited, self regulated screen protected drip proof type with Class 'H' Insulation Salient pole revolving field and electronic Automatic Voltage Regulator for voltage regulation of + 0.5% from No load to full load, standard enclosure 415 Volt 50 HZ 4 pole 62.5 KVA cap complete as per IS-13364-2 and conf to IS-4722 or BS 2613-1970 all as required or recommended by manufactrurer.
(E) Acoustic Enclosure (CANOPY) :- Shall conform to Central Pollution Control Board (CPCB) norms of 75 dBA at one metre under free field conditions, having air inlet louvers specially designed to operate at rated load even at ambient conditions on air inlet temperature,powder coated for long lasting service life and superior finish with UV resistant powder coating to with stand extreme environments, designed to have minimum ease for unloading & shifting , i.e with central lifting facility, rust free hardware made of stainless steel, Insulation material to meet IS:8183 specifications. (F) Fuel Tank :- Draw out type integral fuel tank made of MS sheet (duly painted) of capacity min 200 ltrs or as recommended by manufacturer with level indicator in ltrs, provided with drain plug and air vent / breather and inlet and outlet connections.
(G) Foundation :- Size and type of PCC platform for mounting DG Set and AMF Panel required to be constructed as per manufacturer's specification or as recommeded by Engr - in - Charge. (H) Arrangement of POL for testing of DG Set done by the contractor and rates deemed to be included in quoted rate. J) Spares and tools will be supplied by contractor.
Annual Maintenance Contract for DG set of capacity 63 KVA for the period one year from the date of completion of work. AMC covers any type of repair and replacement of all the parts and accessories (such as filters, coolant, engine oil and hose pipes etc) which bacame unsv due to wear and tear of plant during running including all electrical parts of AMF Panel complete all as specified and directed by Engr - in - Charge. Notes :- (i) Parts and accessories replaced in AMC should be of genuine make or same make as present in ground. (ii) Parts and accessories should be replaced within 24 hours of complaint registered/given to you. (iii) Rate of Parts and accessories included in the quoted rate.
Supply, install, testing and commissioning of UPS for 30 min back up three phase AC input 300 to 450V and out put three phase AC out put Voltage 415 V ± 1% of capacity 30 KVA, suitable for providing uninterrupted power supply without any disturbance to equipment having suitable nos of battery modules for providing 30 minute backup with accessories etc complete all as specified & directed.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 32mm x 6mm (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
MM Constructions
surinder kumar jindal & bros.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .