Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 CrAccepted-AOC | ₹6.4 Cr | L1 | Accepted-AOC Being L1 bidder |
| 2 | L2₹6.5 Cr+₹7.4 L (1.15%)Rejected-Finance | ₹6.5 Cr+₹7.4 L (1.15%) | L2 | Rejected-Finance Not being L1 bidder |
| 3 | L3₹7.0 Cr+₹56.0 L (8.72%)Rejected-Finance | ₹7.0 Cr+₹56.0 L (8.72%) | L3 | Rejected-Finance Not being L1 bidder |
| 4 | L4₹7.8 Cr+₹1.4 Cr (21.1%)Rejected-Finance | ₹7.8 Cr+₹1.4 Cr (21.1%) | L4 | Rejected-Finance Not being L1 bidder |
| 5 | L5₹9.2 Cr+₹2.8 Cr (43.1%)Rejected-Finance 300 GOPAL NIWAS 3 A ROAD SARDARPURA JODHPUR CITY RAJASTHAN 342003 | JODHPUR | RAJASTHAN | 342003 | ₹9.2 Cr+₹2.8 Cr (43.1%) | L5 | Rejected-Finance Not being L1 bidder |
Tender Value
₹7.1 Cr
EMD Value
₹6.8 L
Closing Date
27 Jun 2025, 6:00 pmClosed
Chief Engineer (RnD) Delhi
HQ CE (RnD) Delhi Probyn Road Delhi-54
PROVISION OF BLDG FOR PROCESSING CUM TESTING FACILITY AND LASER ABALATION RESISTIVE COATINGS AT DEFENCE LABORATORY JODHPUR UNDER AGE (I) RnD JODHPUR
2025_MES_707090_1
CE RnD/DLI-01/JODH/2025-26
Open Tender
Civil Works
Lump-sum
330 days
Jodhpur
As per tender documents
8 documents required · 8 mandatory
₹3,000
AGE (I) RnD Jodhpur
₹6.8 L
Yes
29 Jul 2025
8 May 2025
4 Jul 2025
8 May 2025
27 Jun 2025
13 Jun 2025
Amount
Schedule 'A' Section-I to X are under Ser No. 2.00 to 12.00 are prepriced by MES on SSR (Pt-II)-2020
Lump sum price worked out by the Contractor for "BUILDING WORK" as listed in Schedule 'A' Section-I
Lump sum price worked out by the Contractor for “EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’ Section-II
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Section-III
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Section-IV
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Section-V
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Section-VI
Lump sum price worked out by the Contractor for “ROAD/PCC PATH/HARDSTANDING” as listed in Schedule ‘A’ Section-VII
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Section-VIII
Lump sum price worked out by the Contractor for “AIR CONDITIONING & REFRIGERATION” as listed in Schedule ‘A’ Section-IX
Lump sum price worked out by the Contractor for “FIRE ALARM SYSTEM” as listed in Schedule ‘A’ Section-X
Lump sum price worked out by the Contractor for “TRANSFORMER FENCING &STAGING” as listed in Schedule ‘A’ Section- XI
SCHEDULE `A' SECTION - XII MISC ITEMS (To be quoted by the tenderer)
SITE CLEARANCE Clearing jungle including uprooting of rank vegetation, grass, brush wood,trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish outside the periphery of the area cleared. by JCB making good the surface and disposal of rubbish out of DLJ area complete all as directed
INTERNAL WATER SUPPLY M&L for providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes
M&L for providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes
M&L for providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
EXTERNAL WATER SUPPLY M&L for cutting existing GI pipe line of 80 mm and inserting Tee of size 80 x 80 x 50 mm for tapping including fitting of joints complete all as specified and directed by Engineer-in-charge.
M & L for Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design complete all as specified and directed by Engr-in-charge.
Supply and Fixing monoblock pump set of 2.0 HP Single Phase, 230 volt, outlet 50 mm, and 50 mm suction head range minimum 20 mtr, discharge 184 LPM minimum, star rated pump, top suction and including suitable size of copper cable as required complete all as specified and directed.
Supply and Fixing DOL Starter, three Phase suitable for 2.0 HP openwell submersible pump complete all as specified and directed.
INTERNAL ELECTRIFICATION S & F modular blanking plate
Supply and fixing of LED ceiling Mounting Light 36 Watt Consumption 600 MM X 600 MM, having CRCA Sheet Metal Body housing in white powder coated Finish with high translucent diffuser for uniformed Glare Free Light, Elegant Design, IP 20 Protection. Minimum Lumens output of the fitting shall be 5000 Lumens With Efficacy of >100 lm/W, CCT 5700 – 6500K, Surge Protector 4 KV, PF>= 0.95 , Necessary mounting arrangements with all accessories complete all as specified and directed by Engr-in-charge.
Supply and fixing of LED ceiling Mounting Light 24 Watt Consumption 600 MM X 600 MM, having CRCA Sheet Metal Body housing in white powder coated Finish with high translucent diffuser for uniformed Glare Free Light, Elegant Design, IP 20 Protection. Minimum Lumens output of the fitting shall be 5000 Lumens With Efficacy of >100 lm/W, CCT 5700 – 6500K, Surge Protector 4 KV, PF>= 0.95 , Necessary mounting arrangements with all accessories complete all as specified and directed by Engr-in-charge.
Supply and fixing of LED 80 watt downlighter industrial type having PDC housing and toughened glass suitable for industrial application Glare Free Light, Elegant Design, IP 66 Protection. Minimum Lumens output of the fitting shall be 5000 Lumens With Efficacy of >100 lm/W, Surge Protector 10 KV, PF>= 0.95 , Necessary mounting arrangements with all accessories complete all as specified and directed by Engr-in-charge.
Supply and fix Telephone/LAN/WAN socket outlet modular type complete all as specified.
Supply and fix Industrial Socket 3 Phase + 1 Neutral, enclosure with a three pin earth, plug and socket 32 amps complete with one Triple pole and neutral MCB 32 amps complete all as directed by Enge-in-Charge
Supply and fix Industrial Socket 3 Phase, 415 V 50 HZ enclosure with a three pin earth, plug and socket 100/125/160 amps complete all as directed by Enge-in-Charge
M&L for PVC flat submersible cable for water pump at pump house of 6 sqmm 3.0 core FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn ISI marked fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge.
M&L for sub main wiring with four runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 4X16 Sqmm and two run of 10 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size suitable mm dia with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge.NOTE: four runs of cable with two run of earth wire and PVC conduit shall be measured & paid for as one unit.
M&L for sub main wiring with four runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 4X25 Sqmm and two run of 16 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size suitable mm dia with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: four runs of cable with two run of earth wire and PVC conduit shall be measured & paid for as one unit.
Supply, fixing and connecting up complete DB VTPN 4 way suitable for upto 160 Amp MCCB as incomer, double door 415 V AC, 50 Hz, with a provn to mount MCB TP as outgoing 40 Amp to 100 Amp with highly reliable and tested as per IEC 61439-2, degree of protection IP-54, concealed in wall , islolated neutral bus bar and easy to install complete all as specified and directed by Engr-in-Charge.
M&L MCCB 4 Pole, 415 volts, fixed type 100 Amps with breaking capacity 25 KA ,confirming to IEC-60947-II with adjustable overload settings, adjustable short circuit settings, adjustable thermal setting, suitable for VTPN DB including connecting up complete all as specified and directed by Engr-in-Charge.
M&L MCCB 4 Pole, 415 volts, fixed type 125 Amps with breaking capacity 25 KA ,confirming to IEC-60947-II with adjustable overload settings, adjustable short circuit settings, adjustable thermal setting, suitable for VTPN DB including connecting up complete all as specified and directed by Engr-in-Charge.
M&L MCCB 4 Pole, 415 volts, fixed type 160 Amps with breaking capacity 25 KA ,confirming to IEC-60947-II with adjustable overload settings, adjustable short circuit settings, adjustable thermal setting, suitable for VTPN DB including connecting up complete all as specified and directed by Engr-in-Charge.
M&L MCCB 4 Pole, 415 volts, fixed type 100 Amps with breaking capacity 25 KA ,confirming to IEC-60947-II with adjustable overload settings, adjustable short circuit settings, adjustable thermal setting, suitable for VTPN DB including connecting up complete all as specified and directed by Engr-in-Charge.(I/c for FF RHS MDB)
M&L MCB 4 Pole, 415 volts, fixed type 40-100 Amps with breaking capacity 16 KA , thermal class ‘C’ confirming to IEC-60947-II with adjustable overload settings, adjustable short circuit settings suitable for TPN DB including connecting up complete all as specified and directed by Engr-in-Charge.
M&L MCB 4 Pole, 415 volts, fixed type 16-32 Amps with breaking capacity 16 KA , thermal class ‘C’ confirming to IEC-60947-II with adjustable overload settings, adjustable short circuit settings suitable for VTPN DB including connecting up complete all as specified and directed by Engr-in-Charge.
Supply installation testing and commissioning of online UPS for 30 min back up three phase AC input and three phase output, 415 Volt (3P+N) microprocessor controlled generator compitable auto bypass and emergency power off, pure sign wave with following specifications of capacity 40 KVA complete all as specified and directed by Engr-in-Charge.Voltage regulation - 1% (battery mode)Frequency at battery ode - 50+/-0.25HZ Harmonic distortion less than or equal to 2% THD (linear load)Harmonic distortion less than or equal to 5% THD (Non linear load)Efficiency nt less than 95% on AC mode and not less than 93% on battery mode Battery type - 75 AH batteryIron rack for battery with battery interlinks of copper with lugsLED indicators - Load lev, battery level, AC mode, battery mode, by pass mode, fault indicatorAlarm - battery mode/Low bttery/Overload/fault Noise level- 65 dba @1 mtrCommunication - Smart USB port/RS- 232, SNMP card slot Transfer time from AC mode to battery mode- Zero Transfer time from inverter mode to bypass mode- Zero
Supply installation testing and commissioning of online UPS for 30 min back up three phase AC input and three phase output, 415 Volt (3P+N) microprocessor controlled generator compitable auto bypass and emergency power off, pure sign wave with following specifications of capacity 30 KVA complete all as specified and directed by Engr-in-Charge.Voltage regulation - 1% (battery mode) Frequency at battery ode - 50+/-0.25HZ Harmonic distortion less than or equal to 2% THD (linear load) Harmonic distortion less than or equal to 5% THD (Non linear load) Efficiency nt less than 95% on AC mode and not less than 93% on battery mode Battery type - 75 AH battery Iron rack for battery with battery interlinks of copper with lugs LED indicators - Load lev, battery level, AC mode, battery mode, by pass mode, fault indicator Alarm - battery mode/Low bttery/Overload/fault Noise level- 65 dba @1 mtr Communication - Smart USB port/RS- 232, SNMP card slot Transfer time from AC mode to battery mode- Zero Transfer time from inverter mode to bypass mode- Zero
Notes to Item No 18.00 : (i) The contractor shall submit a preliminary drawing showing arrangement of panels, type of Relays etc for approval of Accepting Officer. (ii) The Equipment shall be tested in the presence of representative of Accepting Officer for successful Routine tests as per IS before receipt at site at OEM premises. (iii) Commissioning tests will be carried out in the presence of Engr-in-Charge and Electrical Inspector of the Department. (iv) Panel manufacturer shall be OEM not their vender/system Houses. (v) The make of the relays shall be of AREVA/SCHNEIDER. (vi) Width of the panel shall not be more than 540mm. (vii) VCB shall be complying to "M1" & "E1" category of latest IEC. (viii) VCB shall confirm to IEC : 62271-100 & panel shall be confirm to IEC 62271. (ix) One No PT's and one No. power Pack shall be provided on VCB. (x) All busbars and incoming/outgoing terminals will be of tinned copper. (xi) Cost for Excavation, earth work, PCC,brick work and plastring etc shall be included in the quoted rate by the contractor. (xii) Cost of any arrangement as required at site for installation of new VCB shall be deemed to be included in the quoted rate
Supplying, installation and testing with proper foundation of 11 KV, 630A, 26 KA for 3 Sec SF6 insulated, outdoor type 4 way Ring main unit, extensible motorised and manual operated, in combination of 2 No. VCB modules (As a incomer) & 4 No VCB modules (As a outgoing) consisting of copper busbar in SF6 insulated Grade) stainless steel enclosure of thickness 3.15 mm with manometer. Fixed on the tank. Both the incomer should be interlocked with each other. The Breaker shall have mechanical ON/OFF indicator with hand trip device and spring chagrining, spring release coil, auxiliary switch of 2 NO +2NC. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62272-200-2003 & IEC-60694-1996. The RUM gas tank should be internal arc tested for 26 KA for 1 second with IAC-AFL classification for gas tank. The complete RMU and cable chamber should be covered by minimum two doors to have ingress protection of minimum IP54. The RMU design should support site replaceable HT cable bushing and vacuum interrupter of VCB should be RMU manufacture’s. (a) RMU should have microprocessor with self powered numerical relay with over current, earth fault, short circuit protection, voltmeter and amp meter with each VCB.(b) Protection CT shall be of Burden 2.5VA, ration 100-1A class of accuracy class 5P10 for O/C and E/F protection for each VCB-03 Nos. (c) CT ration is indicative and may vary during detailed engineering, (d) Manometer for each tank -01 No (e) Voltage passage indicator for each feeder -01 No (f) Fault passage indicator for each feeder -01 No (g) Right angle boots for all the feeder modules. (h) Basic insulation level for complete system shall be 28 KV (RMS)/75 KV (Peak) Note: (i) RMU shall be placed on PCC platform, size recomended by OEM /Engr-in-Charge. (ii) Cost for Excavation, earth work, PCC,brick work and plastring etc of PCC plateform shall be included in the quoted rate by the contractor.
Supplying, installing, testing & commissioning of factory assembled Diesel Engine driven generating set including acoustic enclosure as per current CPCB-IV norms automatic mains faillure panel fully wired alternator AC to give an output of 320 KVA/256KW ,continuously rating at a PF of 0.8 lagging, 415 volts , AC 3 phase 4 wire 50 HZ ,1500 RPM, directly coupled with diesel engine water cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads & other accessories etc comprising of following:-
Diesel engine : Water cooled turbocharger of suitable BHP at 1500 RPM confirming to BS 5514 & ISO 3046 with an overload capacity of 10 % for one hour in any 12 continuous hours operation and designed and tested for 50°C ambient temperature with standard fittings.
Alternator : 320 KVA alternator, 3 phase, Power factor:- 0.8, Rated generating voltage:- 230/415V, screened protected, revolving field, self excited, self regulated through an AVR, the alternator has following features:-(i) 'H' class insulation (ii) IP23 protection with insulation class H (iii) +/- 1.0% voltage regulation (maximum) in static condition (iv) permissible overload of 10% for one hour in 12 hours of operations
Control Panel : Control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. including the following:- PowerCommand Controller, Aluminum bus bars with suitable capacity with incoming/ outgoing terminals, Indicating lamps for ‘Load ON’ and ‘Set Running, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections
AMF panel AMF Panel outdoor type, 320 KVA DG Set with alluminium busbar of capacity 500 Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3.15 mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of 400Amps consisting the following:-
INCOMING from 320 KVA (i) MCCB 400 Amp FP 35 KA - 01 No (ii) Spreaders 400 Amps FP - 01 Set (iii) Extended Rotary handle 400 Amps FP - 01 No (iv) Earth fault module - 01 No (v) Power Contactor 400 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No (vi) C.T. 250/5A CL-1.0 10 VA - 03 Nos (vii) Digital MF meter 96 x 96 mm with 485 Port CL 1.0 - 01 No (viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve (x) VMR - 01 No (xi) In built on load change over switch 400 A for bypassing of AMF panel - 01 No
Outgoing (i) MCCB 400 Amp FP 35 KA - 01 No (ii) Power Contactor 400 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (iiI) AMF relay (iv) SMPS 12V, DC, 10A - 01 No (v) Emergency stop P.B - 01 No (vi) Digital Amp meter 12, DC - 01 No (vii) Digital Volt meter 12V, DC - 01 No (viii) Control MCB 6A SP 10 KA C Curve (ix) Hooter - 01 No (x) PROCOM UNIT (DGC6D) FOR control - 01 No
Acoustic Enclosure : Powder coated weather proof canopy. Engine and alternator mounted on AVM mounts, with silencer and SS exhaust below optimised to meet stringent CPCB norms for sound and emission, Baserail with drawout type fuel tank, drain plug, inlet and outlet connections, airvent, level gauge etc
PCC Plateform : size as per OEM recommendation
Batteries : Volts and AH as per OEM.
Supply and fix pole mounting type junction box factory made of size 333x233x155 mm of RP sheet, shockproof and rustproof, fire retardant as per IS:11731 with front openable hinged door, locking arrangement with 4 Nos aluminium bus bas 40 Amp rating mounted on porecelian insulator, cable gland, lugs consisting DIN type rails for fixing MCB SP including one No MCB SP 20 AMP, mild steel plat iron clamp made out of 40x4 mm FI and nut, bolts & wahsers duly painted clamps, nuts and bolts with two coat of synthetic enamel paint over a coat of red oxide primer comopletye all as specified and directed.
M&L for wiring 3 core 2.5 sqmm FRLS PVC insulated copper conductor cable in surface/ recessed including PVC/Steel conduit of 20 mm dia as required complete all as specified and directed by Engineer-in-charge.
M&L sand cushioning to PVC cable with river/tibba sand and punning to provide required cover complete all as directed by Engineer-in-Charge. (Note :- For the purpose of payment only punned thickness will be measured).
M & L for boring in any type of soil under road 1.5 mtr below the top surface of road by conventional method complete for passing through 40 mm to 150 mm dia GI pipe and filling earth after laying of pipe including disposal of surplus soil complete all as specified and directed. Note :- Pipe will be paid and measured seperately. Any damage to existing cale/ pipe line of ant type will made good by the contractor without any extra cost.
M&L for cable path indicator 15cm dia circular type, made out of cast Iron duly embedded with size , voltage and type of HT cable with arrow mark indicting direction of the cable in brown colour fixed on ISA 40x40x6mm angle iron support embedded including in PCC 1:2:4 type B1 (300x300x400mm) and steel surface painted with two coats of anti corrosive paint over a coat of red oxide primer including necessary earth work all as specified and directed.
M&L for cable path indicator 15cm dia circular type, made out of cast Iron duly embedded with size , voltage and type of LT cable with arrow mark indicting direction of the cable in blue colour fixed on ISA 40x40x6mm angle iron support embedded including in PCC 1:2:4 type B1 (300x300x400mm) and steel surface painted with two coats of anti corrosive paint over a coat of red oxide primer including necessary earth work all as specified and directed.
PCC PATH Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
M&L for laying, spreading and compacting stone aggregate as in hardcore of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/ vibratory roller 8-10 tonne capacity in stages to proper grade and camber,applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .
M&L for providing and laying Cement concrete prepared with batch mixing machine design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie barswherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately
M&L for providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 25 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge 60 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners,all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillersshall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.)
M&L for providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction ofthe Engineer-in-Charge.Using grade 'A' sealing compound conforming to IS: 1834
SEWAGE DISPOSAL M&L for DWCPE (SN8) 180 (OD)/163(ID) mm diameter Pipes laid in trenches complete all specified and directed.
M&L for on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 30 users.
M&L for construction of sokage wells excavation, in any type of soil, foundaton in PCC 1:3:6, walls of honey combled masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3 M dia X 3.0 M effective depth
AIR CONDITIONING & REFRIGERATION Supplying, installation, testing and comissioning of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity upto 5 KVA
Supplying, installation, testing and comissioning of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity upto 4 KVA
Supply and fix Desert cooler electric driven single phase having nominal Air flow capacity 4000 Cum per Hrs including front panel with show grill Iron made out of GI sheet 22 SWG complete including front show plate with ON/OFF switch for pump & four speed regulator ISI marked, fan 18" ISI marked , 4 mfd capacitor, submersible pump ISI marked ,wood wool pad (Set of three) heavy duty including interconnecting water and electric witing complete all as specified as directed.
Supply and fix water purifier wall mounted of capacity 50-60 ltrs with automatic operation with max water recovery rate electric driven complete all as specified and directed.
Supplying and laying of 2x1.5 sqmm fire survival armoured cable 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable ethylene propylene rubber (EPR) insulation and LSZH inner bedding steel wire armouring & LSZH outer sheath complete as required.
TRANSFORMER FENCING & STAGING M&L for providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
M&L for providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm welded to angle iron frame includigng priming coat with approved steel primer all complete.
Supplying , stacking , spreading and levelling at site 63 mm to 45 mm size stone aggregate as directed by Engineer-in-charge.
Jeet Construction (BID ID -3330377)
KARNI BUILDERS (BID ID -3329987)
M/s Mohata Buildcon (BID ID -3329793)
UTSAV INDIA LIMITED (BID ID -3339228)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ_792125.xls
BOQ • 0.48 MB
170010763.pdf
Tender Documents • 0.47 MB
170010765.html
Tender Documents • 0.06 MB
172206883.pdf
Tender Documents • 0.36 MB
172769640.pdf
Tender Documents • 1.75 MB
Drg.pdf
Tender Documents • 26.25 MB
Tdr.pdf
Tender Documents • 7.00 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .