GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
EPAIR /ROUTINE MAINTENANCE OF PACKAGE ACS, DUCTABLE ACS AT INS VENDURUTHY AREA, INHS SANJIVANI, INS GARUDA, MO K AND NAY AREA AN PREVENTIVE/ROUTINE MAINTENANCE OF VRF ACS AT CRL, DIVING SCHOOL AND DEHUMIDIFIER AT SEAKING SIMULATORS AT INS GARUDA
2023_MES_623487_1
8284/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Kochi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹96,000
Yes
18 Jan 2024
16 Oct 2023
22 Nov 2023
16 Oct 2023
20 Nov 2023
31 Oct 2023
16 Oct 2023 - 30 Oct 2023
Amount
Preventive Monthly maintenance of screw air compressor 600 CFM capacity ELGI 50 single stage Model EL06150 FAB No : 202432 with 110 HP motor, air and oil separator, cooling tower and connected items installed at PEGASUS NAY including the following all as directed and specified by Engineer in Charge for once in every 1 months( 30 days interval):- (a) Oil check/change. (b) Pressure switches setting, Tips condition checking. (c) Blow down valve functioning and repair. (d) Setting and checking of safety valves. (e) Electrical current measurement in full & no load. (f) Leakage test in joints. (g) Oil leak checking. (h) Oil filters check. (j) Functioning and repair of control systems. (k) Testing of condition of coupling element. (l) Functioning and repair of mechanical valves. (m) Checking and repair PLC/Gauges. (n) Checking of separator or pre separator and repair (o) Servicing of LT electric panel board of compressor. Note: - Major spares for replacement will be measured and paid separately under relevant items here in after but cost of labour for replacement shall be deemed included in quoted rate.
Supply only Oil filter element 220411509 or equivalent.
Supply only Min Oil filter element 220446019 or equivalent.
Supply only Air filter element 220419499 or equivalent.
Supply only Air lube Plus oil 20 L 000998114 or equivalent.
Supply only Separator element 220413270 or equivalent.
Supply only Separator element 220413261 or equivalent.
Supply only Kit Mpv 220371399 or equivalent.
Supply only Blow down valve assay A010029 or equivalent.
Supply only Solenoid valve 220411610 or equivalent.
Supply only Solenoid valve 220470590 or equivalent.
Supply only Kit Pressure Regulator valve 220317599 or equivalent.
Supply only Oil site glass A010018 or equivalent.
Supply only Kit Actuator 220271439 or equivalent.
Supply only Actuator Hose 22047645B or equivalent
Supply only Gasket tank ST1 20S 220428780 or equivalent
Supply only Gasket tank ST2 20S 220428790 or equivalent
Supply and replacement of capacitor for package type of capacity 5.5 to 17.5TR as suitable for existing plant complete all as specified.
Supply and fixing in replacement of digital microprocessor control panels for package AC Units as suitable and fitting for existing model of VLRP type range 6/5/4 Make: Blue star/Soft hard or equivalent.
Supply and replacement scroll type sealed compressor of capacity up to 5.5 TR 3 phase 415 Volt including removing the existing unserviceable compressor with alteration to existing connections including refrigerant charging of suitable refrigerant up to working pressure as required complete all as directed.
Supply and replacement scroll type sealed compressor of capacity above 5.5 TR to 8.75 TR 3 phase 415 Volt including removing the existing unserviceable compressor with alteration to existing connections including refrigerant charging of suitable refrigerant up to working pressure as required complete all as directed.
Material & Labour for monthly servicing the ODU + IDU of Package type /Ductable AC (24 hours Plant) of capacity up to 5.5 TR for AC condenser including cleaning of filter cleaning, air blower cleaning, condenser coil and fins clean with solvent material by using pressure water pump, greasing of blowers, servicing fan motors, checking of gas pressure, dismantling, cleaning and refixing of air diffusers etc complete and all as specified and directed. Note:- Servicing of Each AC in a month shall be considered as One Job.
All as per Item No 22 but capacity of Package type /Ductable AC 7.5 TR to 8.75 TR complete all as specified and directed by Engineer-In-Charge.
All as per Item No 22 but capacity of Package type /Ductable AC 10.00 TR and above complete all as specified and directed by Engineer-In-Charge.
Material & Labour for Bi-Monthly servicing the ODU + IDU of Package type /Ductable AC of capacity up to 5.5 TR for AC condenser including cleaning of filter cleaning, air blower cleaning, condenser coil and fins clean with solvent material by using pressure water pump, greasing of blowers, servicing fan motors, checking of gas pressure, dismantling, cleaning and refixing of air diffusers etc complete and all as specified and directed. Note:- Servicing of Each AC in a month shall be considered as One Job.
All as per Item No 25 but capacity of Package type /Ductable AC 7.5 TR to 8.75 TR complete all as specified and directed by Engineer-In-Charge.
All as per Item No 25 but capacity of Package type /Ductable AC 10.00 TR and above complete all as specified and directed by Engineer-In-Charge.
Supply and fixing of Hard PVC drain piping 40 mm up to drain disposal area with nitrile rubber insulation suitable for chilled water drainage complete all as specified and directed.
Supply and replacing of drier filter suitable for package/ductable AC of capacity 5.5 TR to 8.75 TR complete all as specified and directed. Make: CatchAll/Indfoss/Danfoss
Supply and replacement of drier filter suitable for package/ductable AC of capacity above 8.75 TR to 16.5 TR and above complete all as specified and directed. Make : CatchAll/Indfoss/Danfoss
Material & Labour for replacement of motor bearing, pillow block bearing, blower shaft re-metaling, polishing and reassembling up to capacity of Air blower 6600 CFM complete all as specified and as directed.
Supply and replacement of blower unit complete assembly (excluding fan motor) with base frame, belts etc, suitable for package/ductable AC of capacity up to 16.5 TR complete all as specified and directed.
Supply and replacement of expansion valves in indoor units of capacity not less than 7.5 TR complete all as specified and directed.
Supply and replacement of pre filters suitable for package units of capacity upto 16.5 TR complete all as specified and directed.
Supply and replacement of canvas cloth for connection between indoor unit to plenum duct projection branches for existing indoor units complete all as specified and directed.
Supply and replacement of V belt A series suitable for existing Package AC indoor units complete all as specified and directed. Make: Fenner.
Supply and replacement of V belt B series suitable for existing Package AC indoor units complete all as specified and directed. Make: Fenner.
Material and labour for leak testing of Package type AC plant of capacity up to 16.5 TR including flushing out old moisturised gas and pressuring with nitrogen gas and kept for 24 hours as per OEM specifications, vaccumising nitrogen and refilling of refrigerant gas complete all as specified and as directed. Notes:- 1. Supply and charging of Nitrogen and refrigerant gas will be measured and paid separately. 2.Empty cylinder will returned to contractor after usage.
Material and labour for brazing/welding work at refrigerant copper pipe lines (suction/discharge) and rectify the fault and recharge the refrigerant as desired level in AC units complete all as specified and as directed. Notes:- (i) Welding material, copper pipe material, welding gas cylinder shall be provided by contractor with his own transport up to near the Package AC plants inside Naval Base. (ii) Supply and charging of refrigerant gas will be measured and paid separately.
Supply and charging Refrigerant Gas R-22 in sealed cylinder all as specified and directed by Engineer in Charge.
Supply and charging Refrigerant Gas R-407C in sealed cylinder all as specified and directed by Engineer in Charge.
Supply and charging Refrigerant Gas R-410 in sealed cylinder all as specified and directed by Engineer in Charge.
Supply and replace fan blade for condenser motor suitable for package/ductable AC up to capacity 16.5 TR as per existing at site complete all as specified and directed by Engineer in Charge.
Material & Labour for dismantling of Package AC (capacity up to 16.5 TR) condenser fan motor single phase 240 Volt up to capacity 1 HP taking out of bearing re-metaling the bearing housing, grinding, turning to the required size, cleaning of stator, including rewinding with same gauge copper insulated wire, varnishing, drying, re-assembling the motor to bring in original state including fixing on the foundation complete all as directed by Engineer-In-Charge.
Material & Labour for dismantling of Package AC (capacity up to 16.5 TR) condenser fan motor three phase 415 V up to capacity 1 HP taking out of bearing re-metaling the bearing housing, grinding, turning to the required size, cleaning of stator, including rewinding with same gauge copper insulated wire, varnishing, drying, re-assembling the motor to bring in original state including fixing on the foundation all as directed by Engineer-In-Charge.
Material & Labour for dismantling of Package AC (capacity up to 16.5 TR) blower motor three phase 415 V up to capacity 3 HP taking out of bearing re-metaling the bearing housing, grinding, turning to the required size, cleaning of stator, including rewinding with same gauge copper insulated wire, varnishing, drying, re-assembling the motor to bring in original state including fixing on the foundation all as directed by Engineer-In-Charge.
Material & Labour for attending day to day complaints pertains to various package AC plant of any capacity up to 8.75 TR as and when required by Ref-Mechanic /Electrician and helper , with necessary T&P for checking the equipment at existing location, find out the faults to the equipments (including replacement of minor parts such as decarbonizing, tightening of control cable terminations, cable glands, and end termination, repairing of defective contactors ,push switches, MCBs or any other defective spares crimping of lugs, fuses, wires, nuts ,bolts, washers etc) complete and rectification of minor problems to make the plant functional in all respect all as directed by the Engineer- in-Charge. Notes: (i) Any major work identified while attending the above job shall be measured and paid separately under relevant item below as supply and fix. (ii) Any breakdown/complaints shall be attend and rectify within 6 hours. If the complaint is not attended and repaired within 12 hours, penalty of Rs 2000/- per day will be charged. (iii) Attending of Each Complaint shall be considered as One Job.
All as per Item No 47 but capacity of Package AC Units shall be above 8.75 TR to 16 TR.
Repair to thermal insulation of duct complete with skilled labour and necessary equipments complete all as specified and as directed. Notes: - (i) The cost for replacement of nitrile rubber up to 1 Sqm to be included in the above item. (ii) Any additional nitrile rubber required beyond 1 Sqm for the repair work, the item will be measured and paid separately. (iii) The quoted rate should be included for necessary T&P and Labour. (iv) Repair to each duct shall be considered as One Job.
Taking down any type of false ceiling for AC duct repair work and refix after repair/arresting of water leaking including all required accessories and make it good complete all as specified and as directed. Notes: (i) Any damages made to false ceiling during execution of the above, the same may be repaired/replaced by the contractor without any additional cost. (ii) Cost of additional materials required for making it good as per existing surface deemed to include in the quoted rate.
Material and labour for checking of existing condition of air ducts making the arrangement of visualization and the process for disinfection for indoor air quality of AC ducts of inside, connection in between plenum and branches and main plenum with mechanical/Manual procedures with using air compressor, various type of air nozzles for maintain standard indoor air quality complete all as specified and as directed.
Supply, laying of GI Pipes including welding, connecting and painting two coat of synthetic enamel paint complete of medium grade with all fittings and fixtures laid in trenches/floors or fixed to walls and ceilings etc. of size 50mm dia complete all as specified and as directed.
Preventive maintenance and check up of Dehumidifier Installed at FATS Garuda, capacity of 4850/5000 CFM including complete accessories and controls, The entire system to be checked and servicing by OEM or authorised service agency throughout CA duration and incase of any breakdown occurs at any time, The tenderer shall be attend the complaint and made serviceable within 48 hours time including minor spares such as fuses, wires, nut, bolts etc. for above mentioned all as specified and directed by Engineer-in-charge. Notes:- (i) Dehumidifier Model No FLI 7300, Serial No. 2013-BAC-18620 Make: Bry-Air. (ii) Maintenance carried out in a month shall be considered as One Job.
All as above item No 53 but Dehumidifier Model No FLI 7300, Ser No. 2018-BAC-28982 Make: Bry-Air Notes for item No-53 and 54:- Major spare parts are measured and paid separately under relevant item in BOQ and labour charges for replacement shall be deemed to include in the quoted rate above.
Supply only React filter Air inlet pre-filter. Make:- Recommended by OEM (Bry- Air)
Supply only SSR (Solid state relay), working capacity 90-250V AC. Make:- Recommended by OEM (Bry- Air)
Supply only Thermostat 50-300 DEC. Make:- Recommended by OEM (Bry- Air)
Supply only Limit Switch. Make:- Recommended by OEM (Bry- Air)
Supply only Process filter Air inlet Pre Filter. Make:- Recommended by OEM (Bry- Air)
Supply only Pressure Switch. Make:- Recommended by OEM (Bry- Air)
Supply only Locking device sensor. Make:- Recommended by OEM (Bry- Air)
Supply only suitable panel door handle. Make:- Recommended by OEM (Bry- Air)
Supply and fix Suitable Air volume control damper at common suction entry for dehumidifiers at FATS as per requirement at site.
Supply only heater 9.5 kw. Make:- Recommended by OEM (Bry- Air)
Supply only Bed delay timer. Make:- Recommended by OEM (Bry- Air)
Supply only bed spring socket. Make:- Recommended by OEM (Bry- Air)
Supply only bed react heater wire. Make:- Recommended by OEM (Bry- Air)
Supply only Vacuum seal suitable for existing Dehumidifier, Model No. FLI 7300, Part No 43115. Make:- Recommended by OEM (Bry- Air)
Preventive maintenance and routine checkup of the outdoor VRF unit of capacity 12HP to18 HP having 02 Inverter Compressors, installed at 06 nos at Diving school, 02 nos at CRL including clean with Air blower of condensing coil, outdoor fan motors , replace the communication cables and sensor if found defective, all kind of repair cost of replacement of spare parts. Make :LG
Preventive maintenance and routine checkup of the indoor VRF cassette unit of capacity 4TR Ceiling Suspended units, 04 Nos at Diving school, 06 Nos at CRL, clean with mild Air blower in the coil side and remove the inside fine filter, cleaned with Soap solution after cleaning process fix in proper place, check the drainage water tank and cleaned, replace the communication cables and sensor if found defective including all kind of replacement of spare parts. Make: LG/voltas Note: contractor shall be responsible for replacement of false ceiling, if damage occurred while servicing of Ceiling suspended units.
Preventive maintenance and routine checkup of the indoor VRF AHUs of capacity 8 TR Ceiling suspended units installed at Diving school, clean with mild Air blower in the coil side and remove the inside fine filter, cleaned with Soap solution after cleaning process fix in proper place, check the drainage water tank and cleaned, replace the communication cables and sensor if found defective including all kind of replacement of spare parts. Make: LG Note: contractor shall be responsible for replacement of false ceiling, if damage occurred while servicing of Ceiling suspended units.
Supply & fixing of replacement of 13 mm thickness Thermal Insulation of exposed area of ducting covering on ducts using Class “O” Nitrile Rubber outer side of existing pipelines using manufacturer's recommended Rubber based Adhesive in a blend of solvents complete as per specifications. Make:superlone/aerocell/ K flex/Aeoroflex
Supply and fixing of Thermal insulation class "O" nitrile rubber insulation density 45-55 kg/m3, for suction/discharge piping of VRF pipe lines suitable size of dia as per site, complete all as specified and directed.
Supply and fix in replacement of suitable inverter type fan motor of 18 TR/16TR outdoor unit complete all as specified and directed. Make: Recommended by OEM LG
Supply and fix in replacement of suitable inverter type fan motor of 12 TR outdoor unit complete all as specified and directed. Make: Recommended by OEM LG
Supply and fix in replacement of indoor inverter fan motor for cassette type indoor unit complete all as specified and directed. Make: Recommended by OEM LG
Supply and fix in replacement of Ceiling suspended AHU's Fan Blower with connected items complete all as specified and directed. Make: Recommended by OEM LG.
Material & Labour for servicing of existing AHU motor of capacity up to 8HP including fan after disconnecting electric connection from motor terminal and opening the motor cover, re-metalling the bearing housing shaft, replacing with new bearings of existing size, cleaning , re assembling including transportation from existing location to workshop and back, refixing of electrical connections, testing after repair, refixing of blower belt, alignment with blower with motor structural frame work and complete painting, recommissioning all as specified and directed by Engineer-in-charge.
Supply and fix suitable belt AHU suitable for make LG VRF unit at Diving School. Make: Recommended by OEM LG model No. JRUN160LLS4
Supply and fix indoor PCB for cassette type Unit of 4TR capacity. Make: Recommended by OEM LG model No. JRUN160LLS4
Supply and fix indoor sub PCB for cassette type Unit of 4TR capacity. Make: Recommended by OEM LG model No. JRUN160LLS4
Supply and fixing inverter PCB For VRF outdoor capacity of 10 to 18 HP suitable for existing LG make out door units complete all as specified and directed. LG Model No. JRNU48GTMA2
Supply and fixing main PCB For VRF outdoor capacity of 10 to 18 HP suitable for existing LG make out door units complete all as specified and directed. LG Model No. JRNU48GTMA2
Supply and fixing fan PCB For VRF outdoor capacity of 10 to 18 HP suitable for existing LG make out door units complete all as specified and directed. LG Model No. JRNU48GTMA2
Supply and fixing noise filter For VRF outdoor capacity of 10 to 18 HP suitable for existing LG make out door units complete all as specified and directed. LG Model No. JRNU48GTMA2
Supply and fixing Power PCB For VRF indoor capacity of 10 to 18 HP suitable for existing LG make out door units complete all as specified and directed. LG Model No. JRNU48GTMA2
Material & Labour for leak testing of Condenser coil, for Outdoor units of VRF Unit up to capacity 18 HP including pressure test by using nitrogen, brazing/ arresting the leaks all as per OEM recommendation and directed by Engineer in charge.
Supply and fix in replacement of remote Control for cassette type Indoor unit at VRF system. Make: Recommended by OEM LG/Voltas
Material & Labour for servicing to the outdoor unit and indoor unit of Precision air conditioning system, cleaning of filters & condenser by using pressure water, clean with mild Air blower in the cooling coil side and servicing the entire unit including repairing, check gas pressure/leakage and rectify if any all as specified and directed by Engineer in charge.Make :Bluestar/Uniflair
Supply and fix outdoor motor PAC existing make outdoor unit complete all as specified and as directed. Make :Bluestar/Uniflair
Supply and fix air filter for PAC at INMAC complete all as specified and as directed. Make:Bluestar/ Uniflare
Supply and Fix HP & LP cutout switch for PAC unit at INMAC complete all as specified and as directed. Make:Bluestar/ Uniflare
Supply and Fix temperature controller for PAC unit at INMAC complete all as specified and as directed. Make:Bluestar/ Uniflare
Supply and Fix contactor and overload relay for PAC unit at INMAC complete all as specified and as directed. Make:Bluestar/ Uniflare
Supply and Fix evaporator fan motor for PAC unit at INMAC complete all as specified and as directed. Make:Bluestar/ Uniflare
Supply and Fix indoor pcb for PAC unit at INMAC complete all as specified and as directed. Make:Bluestar/ Uniflare
Supply and Fix expansion valve for PAC unit at INMAC complete all as specified and as directed. Make:Bluestar/ Uniflare
Supply and Fix Solenoid valve for PAC unit at INMAC complete all as specified and as directed. Make:Bluestar/ Uniflare
Supply and Fill R-32 gas complete all as specified and as directed
Supply and replacement of catch all core as suitable in existing pipe line for VRF suction/discharge line complete all as specified and directed
Supply and fix in replacement of Liquid line solenoid valve for VRF system complete all as specified and directed. Make: Blue star/LG
Supply and fix in replacement of Fan blades suitable for existing outdoor units VRF system complete all as specified and directed
Supply and fix Drain Pump for four way cassette/CSU units indoor units of VRF Unit up to 16 HP including testing all as directed
Material & Labour for servicing of outdoor unit and indoor unit of cassette type air conditioning system of capacity 2 TR, installed at SFNA, including cleaning of filters & condenser coil using pressure water pump and indoor to be serviced by keeping waterproof cover bag with drain outlet and support plates to ensure hygienity of room, indoor unit shall be cleaned by best foam less AC coil cleaner in the cooling coil side and servicing the outer unit with water jet pump, removing the drain pipe and flushing out the drain particles including repairing, checking of gas pressure/leakage and all as directed by Engineer in charge.Make :Lloyd
Material & Labour for servicing to the outdoor unit and indoor unit of cassette type air conditioning system of capacity 4 TR installed at SFNA, including cleaning of filters & condenser coil using pressure water pump and indoor to be serviced by keeping waterproof cover bag with drain outlet and support plates to ensure hygienity of room, indoor unit shall be cleaned by best foam less AC coil cleaner in the cooling coil side and servicing the outer unit with water jet pump, removing the drain pipe and flushing out the drain particles including repairing, checking of gas pressure/leakage and all as directed by Engineer in charge.Make :Lloyd
Material & Labour for servicing to the outdoor unit and indoor unit of cassette type air conditioning system of capacity 2 TR installed at ATC Garuda, including cleaning of filters & condenser coil using pressure water pump and indoor to be serviced by keeping waterproof cover bag with drain outlet and support plates to ensure hygienity of room, indoor unit shall be cleaned by best foam less AC coil cleaner in the cooling coil side and servicing the outer unit with water jet pump, removing the drain pipe and flushing out the drain particles including repairing, checking of gas pressure/leakage and all as directed by Engineer in charge.Make :LG
Amount of credit schedule will be dected to arraive the contract Sum.
AISWARYA ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .