Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC MOHANPURA MAHAMMADPUR SOUTH CIVIL LINES PO MILAP NAGAR ROORKEE 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹28.5 L+₹1.9 L (6.96%)Rejected-AOC 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L2 | Rejected-AOC Rejected not being L1 |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
10 Aug 2021, 6:00 pmClosed
G E ROORKEE
G E ROORKEE
REPAIR MAINT OF CI GI WATER PIPE LINES AND RISING MAINS INCLUDING SLUICE VALVE NON RETURN VALVE VALVE CHAMBERS FIRE FIGHTING SYSTEM ETC AND THEIR CONNECTED MISC ITEMS IN POCKET 5 TO 8 AT ROORKEE AND PURKAZI UNDER GE ROORKEE
2021_MES_451583_2
8392/52/E8
Open Tender
Civil Works
Item Rate
180 days
ROORKEE CANTT AND PURKAZI
AS PER NIT
6 documents required · 6 mandatory
₹500
G E ROORKEE
₹58,000
Yes
4 Dec 2021
20 Jul 2021
12 Aug 2021
20 Jul 2021
10 Aug 2021
27 Jul 2021
Amount
Taking up cast iron water mains of the following bore sizes including all fittings with spigot and socket ends and lead joints including burning out old joints and recovering lead complete all as directed by Engineer-in-Charge. Note:- Excavation & earth work shall be measured and paid for separately.
80 mm dia bore
100 mm dia bore
150 mm dia bore
Supply and laying in trenches of the following bore sizes cast iron pipes class LA spigot and socketed ends, centrifugally cast suitable for tyton joint in lengths as per site requirement complete all as directed.
80 mm dia bore
100 mm dia bore
150 mm dia bore
S&F rubber gasket joint 'tyton joint' for the following bore sizes of cast iron pipes complete all as specified and directed.
80 mm dia bore
100 mm dia bore
150 mm dia bore
M&L for run lead joint for jointing of the following bore sizes of cast iron pipes complete all as directed by Engineer-In-Charge.
80 mm dia bore
100 mm dia bore
150 mm dia bore
S&F in replacement, cast iron fittings such as bends (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing, or double socketed etc), tee pieces, single branch, Y junction, double branch, cross (all socketed or socket and spigot), collars, caps etc suitable for water mains upto 150mm dia bore complete all as specified and directed by Engineer-in-Charge.
S&F in replacement, tail pieces, flange and plugs or dummy flange plate, connecting pieces one end flanged and other socketed or spigot and bell mouth pieces one end flanged and other end tapering as bell mouth suitable for water mains upto 150mm dia bore complete all as specified and directed by Engineer-in-Charge.
S&F "D" joints with nut, bolt & washers for the following bore sizes of water mains complete all as specified and directed by Engineer-in-Charge.
80 mm dia bore
100 mm dia bore
150 mm dia bore
M&L for cutting of the following bore sizes cast iron water mains in position for repair/branch connections or as directed by Engineer-in-Charge.
80 mm dia bore
100 mm dia bore
150 mm dia bore
M&L for drilling and tapping cast iron water mains in position for branch connections of 20mm internal dia complete all as specified and directed by Engineer-in-Charge.
S&F 20mm dia bore straight plain brass ferrule (or connecting screw) screwed both ends and fixed to cast iron pipes complete all as specified and directed by Engineer-in-Charge.
Taking up steel tubing of the following bore sizess from trenches / floors or fixed to walls/ceiling including cleaning for re-fixing or removal from site complete all as specified and directed by Engineer-in-charge. Note:- Excavation & earth work shall be measured and paid for separately.
15mm dia bore
20 mm dia bore
25 mm dia bore
40 mm dia bore
50 mm dia bore
80 mm dia bore
S&F GI tubing of the following bore sizes, medium grade with all fittings and fixed to wall/ceiling or laid in floor/trenches complete al as specified and directed by Engineer-in-Charge.
15mm dia bore
20 mm dia bore
25 mm dia bore
40 mm dia bore
50 mm dia bore
80 mm dia bore
M&L for refixing of old GI pipes of the following bore sizess with all fittings (old or new as per site requirement), laid in trenches/ floors or fixed to wall/ceiling complete al as specified and directed by Engineer-in-Charge.
15mm dia bore
20 mm dia bore
25 mm dia bore
40 mm dia bore
50 mm dia bore
80 mm dia bore
S&F in replacement, gun metal globe or gate valve of the following bore sizess with iron wheel hand screwed both ends for iron pipe complete al as specified and directed by Engineer-in-Charge.
15mm dia bore
20 mm dia bore
25 mm dia bore
40 mm dia bore
50 mm dia bore
M&L for cutting & screwing existing GI Pipe of the following bore sizess for alterations or additions complete al as specified and directed by Engineer-in-Charge.
15mm dia bore
20 mm dia bore
25 mm dia bore
40 mm dia bore
50 mm dia bore
Taking out old unserviceable sluice valves of the following bore sizes and S&F new cast iron body sluice valves with flanged ends conforming to IS-14846, class PN 1.6 with gun metal wedge nut and stainless steel spindle, hand wheel operated including all joints with rubber or fiber board, nuts & bolts, washers, connecting and testing complete all as specified and directed.
80 mm dia bore
100 mm dia bore
150 mm dia bore
200 mm dia bore
M&L for construction of valve chamber of size 1.00m x 1.00m x 1.00m (internal dimensions) with and including excavation in trenches of size 1.66m x 1.66m x 1.10m in soft/loose soil, RFR and removal of surplus soil within 50m, 100mm thick PCC (14:8) type D2 in foundation, one brick thick masonry walls in cement mortar (1:6), 75mm thick coping in PCC (1:3:6) type C1 on top of brick walls, 15 mm thick plastering in cement mortar (1:4) on internal surfaces and on exposed external surfaces, MS cover made of 6.0 mm thick MS sheet welded to angle iron 40mm x40mm x6mm frame of size 1.05mx1.05m fixed in PCC coping with hold fasts made of flat iron 40X5mm, 100mm size MS butt hinges- 2 Nos, MS handle150mm size-1 No made of 10mm dia MS round bar with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and two coats of white wash on plastered / concrete surfaces complete all as specified and directed.
Taking out old unserviceable non-return valves of following bore sizes and S&F new cast iron non-return valves, horizontal flow, flanged at both ends, conforming to IS: 5312, Class PN 1.6 including all necessary rubber gaskets, nuts & bolts, washers, connecting and testing etc complete all as specified and directed.
100mm dia bore
150mm dia bore
Excavation in trenches not exc 1.5mtr wide and not exc 1.5 mtr in depth for laying GI pipe/ CI Pipe etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in soft/ loose soil obtained from excavation including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
Removing excavated surplus soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
M&L for servicing of Joky pump 12.5 HP used in fire fighting system and separate the pump & motor including rewinding of motor, replacement of unserviceable parts such as motor bearings as per existing size & shape, coupling, motor & pump shaft, pump bearings, gland packing, pump impeller etc including transportation to & fro civil workshop for winding as well as any type of lathe machine work etc, installtion and testing of Jocky pump to the satisfactory level complete all as directed by Engineer-in-Charge.
M&L for servicing of centrifugal motor pump set 60 HP (Main Pump for fire fighting system) including rewinding of motor, replacement of unserviceable motor bearings as per existing sizes & shape, coupling, motor shaft, pump bearings, gland packing, impeller, pump shaft etc including transportation to & fro civil workshop for winding as well as any type of lathe machine work etc and testing of the motor pump upto the satisfactory level complete all as directed by Engineer-in-Charge.
M&L for servicing of Diesel Engine driven water pump set (Engine & Pump both) used in fire fighting system including transportaion to & fro civil workshop for lathe machine work and calibratin of FIP, replacement of unserviceable Diesel filter, Engine Oil, Oil filter, gasket kit, coollant, bearings, Pump shaft bearings, gland packing, servicing of alternator etc complete all as directed by Engineer-in-Charge.
M&L for servicing of centrifugal motor pump set 7.5 HP AC, 3 phase, 430 Volt 50 Hz Presssure Pump for fire fighting system including rewinding of motor, replacement of unserviceable motor bearings as per existing size & shape, coupling, motor shaft, pump bearings, gland packing, impeller, pump shaft including transportation to & fro civil workshop for winding as well as any type of lathe machine work etc and testing the motor pump upto the satisfactory level complete all as directed by Engineer-in-Charge. Note for Item Nos 22 to 25:- The rate quoted by the contractor shall be deemed including the cost of transportation to civil workshop & back, any type of lathe machine work, testing & calibration, setting of injectors (for engine only), opening of engine head / complete engine, replacement of unserviceable spare parts, re-assembling, testing and commissioning complete.
Supply and laying/ fixing in replacement, 80mm dia bore MS ERW pipe, heavy duty for water used in fire fighting system, laid in floors or fixed to wall / ceiling including necessary bending, enlarging or reducing as per existing degree and connected with existing pipe by means of welding including two coats of synthetic enamelled paint of red colour over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge
S&F in replacement, battery secondary lead acid, 12 Volt 150 AH, heavy duty, maintenance free, electrolyte filled and initially fully charged including making connections with the battery terminal to the alternator of DG Set complete all as directed by Engineer-in-Charge. Make: Exide heavy duty or other equal and approved
M&L for repair of fire alarming system panel public addressy type and testing & commisisoning after repair by replacing the burnt communication card, display card, CPU card, dry alkaline batery of 12 Volts - 02 Nos of approved make, internal circuit, re-mounted on wall, connecting to the existing ciruit of smoke detector and tesing complete all as directed by Engineer-in-Charge.
Day to day maintaince / repair/ rectification of water supply complaints against any kind of fault in water pipe line of any size and type or No water supply complaint from building mounted OHT or any other complaint all as directed time to time by digging / tightening of fittings / colking of lead in CI pipe joints / replacing of GI fittings etc including necessary excavation, returning filling and removing surplus soil (if required) and rectification of complaint to ensure satisfatory serviceability of the water supply with the help of providing the one plumber with one helper on daily basis complete all as directed by Engineer-in-Charge. Note:- (i) The items required to replace shall be measured & paid for seperately under relevant item of BOQ at 'Supply only' rates. (ii) The Contractor shall be fully responsible to provide necessary transportaion, T&P and safety equipment to his labour to prevent any type of accidents and department will not responsible to provide any type of compensation to the contractor or his labour in case of any type of accidents / miss-happening or any type of casuality to his labour/ plumber. (iii) In case any maintenance / complaint informed to the contractor telephonically or verbally or on complaint slip is not rectified within 48 hours, the contractor shall be penalised @ Rs 200/- per complaint per day and shall be recovered from the contractor's dues. (v) The contractor or his representative will report to the concered JE E/M daily in the morning at 9.30 AM to collect the complaints and shall deposite the same to this office after rectification duly signed by the concerned user / occupant of affected accn or area.
Supply only following materials for replacement in day to day maintenance of water supply system by the contractor :- Note:- The materials supplied by the contractor, to be taken on charge by the department in Stores In Hand Ledger through RV duly verified by the Audit Authorities and then to be issued to the contractor through proper Indent to incorporate in the day to day maintenance works.
GI Tee reducer 40 x 40 x 25 mm
GI Tee reducer 50 x 50 x 25 mm
GI Tee equal 25x25x20 mm
GI Tee reducer 20 x 20 x 15 mm
GI Tee equal 25x25x25 mm
GI Tee equal 20x20x20 mm
GI Union 50 mm
GI Union 40 mm
GI Union 25 mm
GI Union 20 mm
GI Union 15 mm
GI Nut nipple 15 mm
GI Nut nipple 20 mm
GI Nut nipple 25 mm
GI barrel nipple 15 mm 6 inches long, screwed at both ends
GI barrel nipple 15 mm 4 inches long screwed at both ends
GI barrel nipple 20 mm 6 inches long screwed at both ends
GI barrel nipple 20 mm 4 inches long screwed at both ends
GI barrel nipple 25 mm 6 inches long screwed at both ends
GI barrel nipple 25 mm 4 inches long screwed at both ends
GI screwed plug 15 mm
GI screwed plug 20 mm
GI screwed plug 25 mm
GI elbow 15 mm
GI elbow 20 mm
GI elbow 25 mm
GI socket 15 mm
GI socket 20 mm
GI socket 25 mm
MS machine made nuts, bolts & washers of any size and type as per sample
PTMT bib tap 15mm dia bore of any colour, high pressure, standard quality of approved make.
VIJAY ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .