The Gujarat Cancer and Research Institute
: Proposed New Construction of Cyclotron and Nuclear Medicine Building for GCRI at Asrawa, Ahmedabad
308179
2025-26
Open
Civil Works
Ahmedabad
7 documents required · 6 mandatory · 1 optional
₹30,000
THE GUJARAT CANCER AND RESEARCH INSTITUTE
₹88.9 L
25 May 2026
25 May 2026
25 May 2026
15 Jun 2026
25 May 2026
Description Total Amount (In Rs.)
C Grand Total Rs.
SOR Item of Description Unit Rate Total Amount
(i) R.C.C. work
Chapter 20 Demolition of Brick work and stone masonry including stacking of serviceable materilas and disposal of unserviceable materials with all lead
2 20003B 140.00 and lift. Cum 550.40
Page - 149 (ii) In Cement Mortar.
Chapter 20 Dismentaling of sheet roofing including ridges, Hips, Valleys, Gutters etc. stacking of serviceable materilas and disposal of unserviceable
3 20007A 190.00 materials with all lead and lift. Sqm 47.72
Page - 149 (i) G.I.sheet roofing.
Chapter 20 Dismentaling of sheet roofing including ridges, Hips, Valleys, Gutters etc. stacking of serviceable materilas and disposal of unserviceable
4 20007B 190.00 materials with all lead and lift. Sqm 54.09
Page - 149 (ii) A.C. sheet roofing.
5 20012 4732.00 Dismentling steel work including distempering and stacking the materials with all lead and lift. Kg 3.67
Dismentling doors, windows, ventilators etc. (wood or steel) shutters including chowkhats architraves, holdfasts and other attachment etc.
complete and stacking them within all lead and lift.(i) Not exceeding 3 Sq.M. in area.
Dismentling doors, windows, ventilators etc. (wood or steel) shutters including chowkhats architraves, holdfasts and other attachment etc.
complete and stacking them within all lead and lift.(ii) Exceeding 3 Sq.M. in area.
Chapter 026 Clearing and grubbing road land includding uprooting Trunk vegetation, grass, bushes, shrubs, saplings and trees girth upto 300mm removal of
8 26117C 3297.00 stumps of tress cut earlier and disposal of unserviceable materials. Sqm 2.85
Page - 213 A) By Mechanical means in area of light jungle.
Excavation for foundation including shoring & shruting upto 1.5 mt.depth All kind of Soil. including sorting out and stacking of unuseful
materials and disposing off the excavated stuff upto all lead and lift.(Excavated earth / Stuff to be stacked and surplus earth disposed at non
objectinable place to be found by the Contractor and necessary permision to be obtained by contractor from local authority/ Government with
royalty certification if applicable)
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Excavation for foundation including shoring & shruting for 1.5 mt. to 3.0 mt. All kind of Soil. including sorting out and stacking of useful
materials and disposing off the excavated stuff upto all lead and lift (Excavated earth / Stuff to be stacked and surplus earth disposed at non
objectinable place to be found by the Contractor and necessary permision to be obtained by contractor from local authority/ Government with
royalty certification if applicable )
Excavation for foundation including shoring & shruting for 3.0 mt. to 5.0 mt. All kind of Soil. including sorting out and stacking of useful
materials and disposing off the excavated stuff upto all lead and lift.(Excavated earth / Stuff to be stacked and surplus earth disposed at non
objectinable place to be found by the Contractor and necessary permision to be obtained by contractor from local authority/ Government with
royalty certification if applicable)
Chapter 04 Extra for additional depth more than 5.0 m for excavation for foundation including sorting out and stacking of useful materials and disposing off
12 04003B & 04004B 0.00 the excavated stuff upto 50 m lead. (Excavated earth / Stuff to be stacked and surplus earth disposed at non objectinable place to be found by Cum 195.34 -
Page - 48 the Contractor and necessary permision to be obtained by contractor from local authority/ Government with royalty certification if applicable)
Chapter 04 Filling available selected / approved stacked excavated earth (excluding rock) (Earth which is stacked at any location outside the campus non-
13 4006 12319.00 objectionable place shall be found by the contractor) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth Cum 130.39
Page - 48 consolidating each deposited layer by ramming and watering
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing etc. complete. (Royalty shall be paid by
contractor and supporting document submitted to client for verification.)
Filling in foundation and plinth with murrum or selected soil in layers of 20cm. thickness including watering, ramming and consolidating etc.
Providing and laying rubble soling, 23 cm thick, in a compact manner, foudation, road, footpath etc. using 200 to 230 mm. cut size stones,
16 RA - 1 1490.00 covering and levelling the surface with a layer of murrum after filling the voids with smaller sized stones or stone chips, including watering, Cum 2,716.52
ramming well and consolidating each layer, As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and filling with styrofoam/cinder (good quality) in sunks in layers of 15 cm thk including watering placing ramming well etc. As per
drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and laying cement concrete 1:2:4 (1Cement : 2- Coarse sand : 4- graded stone aggregates 20 mm nominal size) and curing complete
18 RA - 3 1101.00 including cost of formwork in Cum 4,084.44
(A) Foundation and Plinth
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(B) Plinth Beam
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(B) Plinth Beam
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
22 23.00 charge and approved , rates includes all levels , heights as upto 4.50 m , excluding reinforcement . Cum 6,697.60
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in
(i) Basement-1 & Up to Plinth
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights as upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) Column up to Ground Floor Slab lvl.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights as upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) Column up to First Floor Slab lvl.
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights as upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) Column up to Second Floor Slab lvl.
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights as upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) Column up to Third Floor Slab lvl.
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights as upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) Column up to Fourth Floor Slab lvl.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
28 RA - 6 219.00 charge and approved , rates includes all levels , heights as upto 4.50 m , excluding reinforcement . Cum 6,795.86
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in
(i) Up to Plinth
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights as upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) Column up to Ground Floor Slab lvl.
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights as upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) Column up to First Floor Slab lvl.
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) Column up to Second Floor Slab lvl.
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) Column up to Third Floor Slab lvl.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) Column up to Fourth Floor Slab lvl.
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) Column up to Fifth Floor Slab lvl.
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) Column up to Sixth Floor Slab lvl. (Terrace Floor Slab lvl.)
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
36 11.00 charge and approved , rates includes all levels , heights as upto 4.50 m, excluding reinforcement . Cum 6,735.33
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
i) Basement-1 & Up to Plinth
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(D) RCC Wall up to Ground Floor Slab lvl .
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(D) RCC Wall up to First Floor Slab lvl .
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(D) RCC Wall up to Second Floor Slab lvl .
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(D) RCC Wall up to Third Floor Slab lvl .
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(D) RCC Wall up to Fourth Floor Slab lvl .
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
42 RA - 8 78.00 charge and approved , rates includes all levels , heights as upto 4.50 m, excluding reinforcement . Cum 6,833.58
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(D) RCC Wall up to Ground Floor Slab lvl .
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 to accelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(D) RCC Wall up to First Floor Slab lvl .
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 to accelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(D) RCC Wall up to Second Floor slab lvl .
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(D) RCC Wall up to Third Floor Slab lvl .
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(D) RCC Wall up to Fourth Floor Slab lvl .
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(D) RCC Wall up to Fifth Floor Slab lvl .
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(D) RCC Wall up to Sixth Floor Slab lvl .
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
50 39.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,646.67
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Floor Beam
i) Ground Floor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
51 39.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,686.92
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Floor Beam
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
52 39.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,727.17
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Floor Beam
i) Second Floor
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
53 11.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,767.41
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Floor Beam
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
54 0.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,807.66 -
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Floor Beam
i) Fourth Floor
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
55 RA - 10 408.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,744.92
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Floor Beam
i) Ground Floor
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
56 RA - 10 405.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,785.17
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Floor Beam
ii) First Floor
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
57 RA - 10 405.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,825.42
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Floor Beam
iii) Second Floor
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
58 RA - 10 405.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,865.67
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Floor Beam
iv) Third Floor
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
59 RA - 10 405.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,905.92
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Floor Beam
v) Fourth Floor .
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
60 RA - 10 405.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,946.16
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Floor Beam
vi) Fifth Floor .
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
61 RA - 10 164.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,986.41
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Floor Beam
vii) SixthFloor .
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
62 RA - 11 75.00 charge and approved , rates includes for any level, any floor and any height, excluding reinforcement. Cum 5,834.84
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Lintel, sill and Mullians Bands
i) Ground Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
63 RA - 11 70.00 charge and approved , rates includes for any level, any floor and any height, excluding reinforcement. Cum 5,875.09
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Lintel, sill and Mullians Bands
ii) First Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
64 RA - 11 65.00 charge and approved , rates includes for any level, any floor and any height, excluding reinforcement. Cum 5,915.34
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Lintel, sill and Mullians Bands
iii) Second Floor
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
65 RA - 11 75.00 charge and approved , rates includes for any level, any floor and any height, excluding reinforcement. Cum 5,955.59
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Lintel, sill and Mullians Bands
iv) Third Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
66 RA - 11 54.00 charge and approved , rates includes for any level, any floor and any height, excluding reinforcement. Cum 5,995.83
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Lintel, sill and Mullians Bands
v) Fourth Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
67 RA - 11 106.00 charge and approved , rates includes for any level, any floor and any height, excluding reinforcement. Cum 6,036.08
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Lintel, sill and Mullians Bands
vi) Fifth Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
68 RA - 11 22.00 charge and approved , rates includes for any level, any floor and any height, excluding reinforcement. Cum 6,076.33
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Lintel, sill and Mullians Bands
vii) Sixth Floor
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
69 RA - 12 73.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 5,883.64
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Weathershed
i) Ground Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
70 RA - 12 65.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 5,923.89
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Weathershed
ii) First Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
71 RA - 12 65.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 5,964.14
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Weathershed
iii) Second Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
72 RA - 12 65.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,004.39
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Weathershed
iv) Third Floor
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
73 RA - 12 53.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,044.64
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Weathershed
v) Fourth Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
74 RA - 12 53.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,084.89
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Weathershed
vi) Fifth Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
75 RA - 12 23.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,125.13
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Weathershed
vii) SixthFloor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
77 34.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,033.49
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
i) Ground Floor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
78 34.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,073.74
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
79 34.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,113.98
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
i) Second Floor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
80 8.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,154.23
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
81 RA - 14 380.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,131.74
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
i) Ground Floor
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
82 RA - 14 372.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,171.99
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
ii) First Floor
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
83 RA - 14 372.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,212.24
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
iii) Second Floor
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
84 RA - 14 372.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,252.49
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
iv) Third Floor
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
85 RA - 14 298.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,292.73
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
v) Fourth Floor
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
86 RA - 14 298.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,332.98
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
vi) Fifth Floor
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
87 RA - 14 36.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,373.23
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
vii) Sixth Floor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
88 6.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 5,914.95
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Stair Case
i) Ground Floor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
89 6.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 5,955.20
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Stair Case
ii) First Floor
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
90 6.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 5,995.45
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Stair Case
iii) Second Floor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
91 6.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,035.70
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Stair Case
iv) Third Floor
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
92 RA - 15 15.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,013.21
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Stair Case
i) Ground Floor
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
93 RA - 15 15.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,053.46
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Stair Case
ii) First Floor
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
94 RA - 15 15.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,093.70
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Stair Case
iii) Second Floor
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
95 RA - 15 15.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,133.95
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Stair Case
iv) Third Floor
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
96 RA - 15 15.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,174.20
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Stair Case
v) Fourth Floor
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work , using cement content as per
approved design mix including pumping of concrete to site of laying, cost of Centering , shutterings, finishing, grouting if required , admixture
in recommended proposition as per IS:9103 toaccelerated , retard, setting of concrete, improve workability as per direction of engineer in
97 RA - 15 15.00 charge and approved , rates includes all levels , heights upto 4.50m , excluding reinforcement . Cum 6,214.45
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced concrete work in:
(C) RCC Stair Case
vi) Fifth Floor
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and
98 R.A-16 257.00 finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush including The panel Cum 8,360.33
shuttering work etc. complete As per drawings and design supplied by architect and instruction given by authority and E.I.C.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying High Density Reinforced Cement Concrete (HDRCC) of minimum density 2.5 g/cc or as specified in approved radiation
shielding design, using approved heavy aggregates such as using approved cold water, special category of sand (density: 4500 to 4800 Kg/m3),
Barytes / Magnetite and incorporating boron carbide where required for neutron attenuation, in cyclotron bunker walls of any thickness, height
and level, including design mix minimum M40, mix design submission and approval, trial mixes to achieve required strength and density,
controlled weigh batching, mechanical mixing, transporting, placing in layers not exceeding 500 mm lift, continuous vibration to achieve void-
free homogeneous mass, finishing and curing complete. The work shall be executed strictly using reusable heavy duty modular Table Form /
Column Form / Wall Form System (Outinord or Equivalent approved) with comprising factory engineered steel formwork panels with
approximately 4 mm thick steel facing plates stiffened with vertical omega profiles and horizontal walers, modular table forms with telescopic
lyre-type adjustable legs, back-to-back U-profile deck frames and shuttering grade plywood decking, modular column forms with adjustable
steel panels and locking clamps, and wall form systems with integrated connecting levers, tie rod assemblies, push–pull props, working
99 RA - 17 1151.00 platforms and bracing arrangements; including provision for lifting hooks for crane handling, slab stop ends, guard rails, filler panels, leveling Cum 32,787.15
jacks and all necessary accessories to achieve required alignment, rigidity and dimensional accuracy; designed for concrete pressure as per
CIRIA Report 108 and manufacturer’s guidelines, ensuring maximum admissible live load 4500 daN per stability calliper and lifting angle
limits as specified in manufacturer’s manual including assembling, alignment within ±1 mm tolerance, controlled concreting speed to limit
lateral pressure below 8 t/m², provision of magnetic stop-ends, cones, ties, and sacrificial lining where required, safe cranage with minimum 4 m
slings and 45° maximum sling angle, complete stripping, cleaning and oiling of panels after each pour. The rate shall include continuous density
testing, cube testing, radiation shielding compliance testing, shuttering with Table Form/Column Form/Wall Form System formwork only,
making and sealing of all openings, penetrations and recesses to prevent radiation streaming, refilling and reinstatement with matching high-
density concrete, smooth internal finish suitable for epoxy coating, all leads and lifts, labour, plant and machinery, safety systems, annual
inspection and certified use of stability callipers, complete as per approved structural drawings, approved radiation shielding design, IS 456, IS
10262, IS 1199, and AERB Safety Guide (latest 2025 edition), and as directed by Engineer-in-Charge. for RCC Wall
Providing and laying High Density Reinforced Cement Concrete (HDRCC) of minimum density 2.5 g/cc or as specified in approved radiation
shielding design, using approved heavy aggregates such as using approved cold water, special category of sand (density: 4500 to 4800 Kg/m3),
Barytes / Magnetite and incorporating boron carbide where required for neutron attenuation, in cyclotron bunker walls of any thickness, height
and level, including design mix minimum M40, mix design submission and approval, trial mixes to achieve required strength and density,
controlled weigh batching, mechanical mixing, transporting, placing in layers not exceeding 500 mm lift, continuous vibration to achieve void-
free homogeneous mass, finishing and curing complete. The work shall be executed strictly using reusable heavy duty modular Table Form /
Column Form / Wall Form System (Outinord or Equivalent approved) with comprising factory engineered steel formwork panels with
approximately 4 mm thick steel facing plates stiffened with vertical omega profiles and horizontal walers, modular table forms with telescopic
lyre-type adjustable legs, back-to-back U-profile deck frames and shuttering grade plywood decking, modular column forms with adjustable
steel panels and locking clamps, and wall form systems with integrated connecting levers, tie rod assemblies, push–pull props, working
100 RA - 17A 404.00 platforms and bracing arrangements; including provision for lifting hooks for crane handling, slab stop ends, guard rails, filler panels, leveling Cum 32,787.15
jacks and all necessary accessories to achieve required alignment, rigidity and dimensional accuracy; designed for concrete pressure as per
CIRIA Report 108 and manufacturer’s guidelines, ensuring maximum admissible live load 4500 daN per stability calliper and lifting angle
limits as specified in manufacturer’s manual including assembling, alignment within ±1 mm tolerance, controlled concreting speed to limit
lateral pressure below 8 t/m², provision of magnetic stop-ends, cones, ties, and sacrificial lining where required, safe cranage with minimum 4 m
slings and 45° maximum sling angle, complete stripping, cleaning and oiling of panels after each pour. The rate shall include continuous density
testing, cube testing, radiation shielding compliance testing, shuttering with Table Form/Column Form/Wall Form System formwork only,
making and sealing of all openings, penetrations and recesses to prevent radiation streaming, refilling and reinstatement with matching high-
density concrete, smooth internal finish suitable for epoxy coating, all leads and lifts, labour, plant and machinery, safety systems, annual
inspection and certified use of stability callipers, complete as per approved structural drawings, approved radiation shielding design, IS 456, IS
10262, IS 1199, and AERB Safety Guide (latest 2025 edition), and as directed by Engineer-in-Charge. for RCC Slab
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying High Density Reinforced Cement Concrete (HDRCC) of minimum density 2.5 g/cc or as specified in approved radiation
shielding design, using approved heavy aggregates such as using approved cold water, special category of sand (density: 4500 to 4800 Kg/m3),
Barytes / Magnetite and incorporating boron carbide where required for neutron attenuation, in cyclotron bunker walls of any thickness, height
and level, including design mix minimum M40, mix design submission and approval, trial mixes to achieve required strength and density,
controlled weigh batching, mechanical mixing, transporting, placing in layers not exceeding 500 mm lift, continuous vibration to achieve void-
free homogeneous mass, finishing and curing complete. The work shall be executed strictly using reusable heavy duty modular Table Form /
Column Form / Wall Form System (Outinord or Equivalent approved) with comprising factory engineered steel formwork panels with
approximately 4 mm thick steel facing plates stiffened with vertical omega profiles and horizontal walers, modular table forms with telescopic
lyre-type adjustable legs, back-to-back U-profile deck frames and shuttering grade plywood decking, modular column forms with adjustable
steel panels and locking clamps, and wall form systems with integrated connecting levers, tie rod assemblies, push–pull props, working
101 RA - 17 270.00 platforms and bracing arrangements; including provision for lifting hooks for crane handling, slab stop ends, guard rails, filler panels, leveling Cum 32,787.15
jacks and all necessary accessories to achieve required alignment, rigidity and dimensional accuracy; designed for concrete pressure as per
CIRIA Report 108 and manufacturer’s guidelines, ensuring maximum admissible live load 4500 daN per stability calliper and lifting angle
limits as specified in manufacturer’s manual including assembling, alignment within ±1 mm tolerance, controlled concreting speed to limit
lateral pressure below 8 t/m², provision of magnetic stop-ends, cones, ties, and sacrificial lining where required, safe cranage with minimum 4 m
slings and 45° maximum sling angle, complete stripping, cleaning and oiling of panels after each pour. The rate shall include continuous density
testing, cube testing, radiation shielding compliance testing, shuttering with Table Form/Column Form/Wall Form System formwork only,
making and sealing of all openings, penetrations and recesses to prevent radiation streaming, refilling and reinstatement with matching high-
density concrete, smooth internal finish suitable for epoxy coating, all leads and lifts, labour, plant and machinery, safety systems, annual
inspection and certified use of stability callipers, complete as per approved structural drawings, approved radiation shielding design, IS 456, IS
10262, IS 1199, and AERB Safety Guide (latest 2025 edition), and as directed by Engineer-in-Charge. for RCC Floor
Chapter 05 Providing and laying TMT Bar FE-500D reinforcement for R.C.C. work and straightening, cutting, bending, binding & placing in position
102 05014C 1932480.00 completed upto all floor all level as per I.S. Standard. complete. As per drawings and design supplied by architect and instruction given by Kg 76.21
Page - 54 authority and E.I.C.
103 RA 17 A 100.00 Shifting of exisitng line electrical, elv, drainage etc. Rmt 505.00
Providing and position PVC Sleeves in RCC elements like walls slabs beams etc. of 6 Kg/cm2 UPVC Pipes and diameter of taking out service
pipelines cables road infrasturcture work etc. upto 0.5 mtr. length for all floors/ all levels / all heights. a) 50mm dia.
Chapter 06 Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement
107 06002BA 688.00 Mortar 1:6 (1- Cement : 6 -fine sand) cum 4,021.02
Page - 71 (B) Conventional
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying autoclave aerated concrete blocks as per drawing in single or multiple layers with approved block laying polymer
modified adhesive mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm, minimum density in oven dry
condition between 651 to 750 KG/CUM, thermal conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb
and cleaning the surface with necessary tool tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and
percent for Grade 2 blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, racking / flush jointing etc
complete, as per drawing / specification etc, complete As per drawings and design supplied by architect and instruction given by authority and
E.I.C. For all civil, plumbing, electrical & infrastructure works.
a) Ground Floor
Providing and laying autoclave aerated concrete blocks as per drawing in single or multiple layers with approved block laying polymer
modified adhesive mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm, minimum density in oven dry
condition between 651 to 750 KG/CUM, thermal conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb
and cleaning the surface with necessary tool tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and
percent for Grade 2 blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, racking / flush jointing etc
complete, as per drawing / specification etc, complete As per drawings and design supplied by architect and instruction given by authority and
E.I.C. For all civil, plumbing, electrical & infrastructure works.
Providing and laying autoclave aerated concrete blocks as per drawing in single or multiple layers with approved block laying polymer
modified adhesive mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm, minimum density in oven dry
condition between 651 to 750 KG/CUM, thermal conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb
and cleaning the surface with necessary tool tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and
percent for Grade 2 blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, racking / flush jointing etc
complete, as per drawing / specification etc, complete As per drawings and design supplied by architect and instruction given by authority and
E.I.C. For all civil, plumbing, electrical & infrastructure works.
c) Second Floor
Providing and laying autoclave aerated concrete blocks as per drawing in single or multiple layers with approved block laying polymer
modified adhesive mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm, minimum density in oven dry
condition between 651 to 750 KG/CUM, thermal conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb
and cleaning the surface with necessary tool tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and
percent for Grade 2 blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, racking / flush jointing etc
complete, as per drawing / specification etc, complete As per drawings and design supplied by architect and instruction given by authority and
E.I.C. For all civil, plumbing, electrical & infrastructure works.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying autoclave aerated concrete blocks as per drawing in single or multiple layers with approved block laying polymer
modified adhesive mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm, minimum density in oven dry
condition between 651 to 750 KG/CUM, thermal conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb
and cleaning the surface with necessary tool tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and
percent for Grade 2 blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, racking / flush jointing etc
complete, as per drawing / specification etc, complete As per drawings and design supplied by architect and instruction given by authority and
E.I.C. For all civil, plumbing, electrical & infrastructure works.
e) Fourth Floor
Providing and laying autoclave aerated concrete blocks as per drawing in single or multiple layers with approved block laying polymer
modified adhesive mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm, minimum density in oven dry
condition between 651 to 750 KG/CUM, thermal conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb
and cleaning the surface with necessary tool tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and
percent for Grade 2 blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, racking / flush jointing etc
complete, as per drawing / specification etc, complete As per drawings and design supplied by architect and instruction given by authority and
E.I.C. For all civil, plumbing, electrical & infrastructure works.
Providing and laying autoclave aerated concrete blocks as per drawing in single or multiple layers with approved block laying polymer
modified adhesive mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm, minimum density in oven dry
condition between 651 to 750 KG/CUM, thermal conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb
and cleaning the surface with necessary tool tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and
percent for Grade 2 blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, racking / flush jointing etc
complete, as per drawing / specification etc, complete As per drawings and design supplied by architect and instruction given by authority and
E.I.C. For all civil, plumbing, electrical & infrastructure works.
Providing and laying Solid Concrete Blocks (400 x 230/300 x 150/200 mm) or as per drawing in single or multiple layers with approved Solid
block laying polymer modified adhesive mortar. , minimum density in oven dry condition between 2350 to 2450 KG/CUM, fire resistant
hours, in true line level and plumb and cleaning the surface with necessary tool tackles including curing, scaffolding, racking / flush jointing etc
complete, as per drawing / specification etc, complete As per drawings and design supplied by architect and instruction given by authority and
E.I.C. For all civil, plumbing, electrical & infrastructure works.
a) Ground Floor
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying Solid Concrete Blocks (400 x 230/300 x 150/200 mm) or as per drawing in single or multiple layers with approved Solid
block laying polymer modified adhesive mortar. , minimum density in oven dry condition between 2350 to 2450 KG/CUM, fire resistant
hours, in true line level and plumb and cleaning the surface with necessary tool tackles including curing, scaffolding, racking / flush jointing etc
complete, as per drawing / specification etc, complete As per drawings and design supplied by architect and instruction given by authority and
E.I.C. For all civil, plumbing, electrical & infrastructure works.
Providing and laying Solid Concrete Blocks (400 x 230/300 x 150/200 mm) or as per drawing in single or multiple layers with approved Solid
block laying polymer modified adhesive mortar. , minimum density in oven dry condition between 2350 to 2450 KG/CUM, fire resistant
hours, in true line level and plumb and cleaning the surface with necessary tool tackles including curing, scaffolding, racking / flush jointing etc
complete, as per drawing / specification etc, complete As per drawings and design supplied by architect and instruction given by authority and
E.I.C. For all civil, plumbing, electrical & infrastructure works.
c) Second Floor
Providing and laying Solid Concrete Blocks (400 x 230/300 x 150/200 mm) or as per drawing in single or multiple layers with approved Solid
block laying polymer modified adhesive mortar. , minimum density in oven dry condition between 2350 to 2450 KG/CUM, fire resistant
hours, in true line level and plumb and cleaning the surface with necessary tool tackles including curing, scaffolding, racking / flush jointing etc
complete, as per drawing / specification etc, complete As per drawings and design supplied by architect and instruction given by authority and
E.I.C. For all civil, plumbing, electrical & infrastructure works.
Providing and laying Solid Concrete Blocks (400 x 230/300 x 150/200 mm) or as per drawing in single or multiple layers with approved Solid
block laying polymer modified adhesive mortar. , minimum density in oven dry condition between 2350 to 2450 KG/CUM, fire resistant
hours, in true line level and plumb and cleaning the surface with necessary tool tackles including curing, scaffolding, racking / flush jointing etc
complete, as per drawing / specification etc, complete As per drawings and design supplied by architect and instruction given by authority and
E.I.C. For all civil, plumbing, electrical & infrastructure works.
e) Fourth Floor
Providing and laying Solid Concrete Blocks (400 x 230/300 x 150/200 mm) or as per drawing in single or multiple layers with approved Solid
block laying polymer modified adhesive mortar. , minimum density in oven dry condition between 2350 to 2450 KG/CUM, fire resistant
hours, in true line level and plumb and cleaning the surface with necessary tool tackles including curing, scaffolding, racking / flush jointing etc
complete, as per drawing / specification etc, complete As per drawings and design supplied by architect and instruction given by authority and
E.I.C. For all civil, plumbing, electrical & infrastructure works.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying autoclave aerated concrete blocks as per drawing (Thickness 100 mm ) in single or multiple layers with approved block
laying polymer modified adhesive mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm, minimum density in
oven dry condition between 651 to 750 KG/CUM, thermal conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and
plumb and cleaning the surface with necessary tool tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and
0.10 percent for Grade 2 blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, racking / flush
jointing etc complete, as per drawing / specification etc, complete As per drawings and design supplied by architect and instruction given by
authority and E.I.C. For all civil, plumbing, electrical & infrastructure works.
a) Ground Floor
Providing and laying autoclave aerated concrete blocks as per drawing (Thickness 100 mm ) in single or multiple layers with approved block
laying polymer modified adhesive mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm, minimum density in
oven dry condition between 651 to 750 KG/CUM, thermal conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and
plumb and cleaning the surface with necessary tool tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and
0.10 percent for Grade 2 blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, racking / flush
jointing etc complete, as per drawing / specification etc, complete As per drawings and design supplied by architect and instruction given by
authority and E.I.C. For all civil, plumbing, electrical & infrastructure works.
Providing and laying autoclave aerated concrete blocks as per drawing (Thickness 100 mm ) in single or multiple layers with approved block
laying polymer modified adhesive mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm, minimum density in
oven dry condition between 651 to 750 KG/CUM, thermal conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and
plumb and cleaning the surface with necessary tool tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and
0.10 percent for Grade 2 blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, racking / flush
jointing etc complete, as per drawing / specification etc, complete As per drawings and design supplied by architect and instruction given by
authority and E.I.C. For all civil, plumbing, electrical & infrastructure works.
c) Second Floor
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying autoclave aerated concrete blocks as per drawing (Thickness 100 mm ) in single or multiple layers with approved block
laying polymer modified adhesive mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm, minimum density in
oven dry condition between 651 to 750 KG/CUM, thermal conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and
plumb and cleaning the surface with necessary tool tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and
0.10 percent for Grade 2 blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, racking / flush
jointing etc complete, as per drawing / specification etc, complete As per drawings and design supplied by architect and instruction given by
authority and E.I.C. For all civil, plumbing, electrical & infrastructure works.
Providing and laying autoclave aerated concrete blocks as per drawing (Thickness 100 mm ) in single or multiple layers with Ready mix
joining mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm, minimum density in oven dry condition between
651 to 750 KG/CUM, thermal conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb and cleaning the
surface with necessary tool tackles, The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and 0.10 percent for Grade
blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. at all floors, any heights, all depths, any levels (in foundation &
Superstructure) and all places including curing, scaffolding, racking / flush jointing etc complete, As per drawings and design supplied by
architect and instruction given by authority and E.I.C. For all civil, plumbing, electrical & infrastructure works.
e) Fourth Floor
Providing and laying autoclave aerated concrete blocks as per drawing (Thickness 100 mm ) in single or multiple layers with approved block
laying polymer modified adhesive mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm, minimum density in
oven dry condition between 651 to 750 KG/CUM, thermal conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and
plumb and cleaning the surface with necessary tool tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and
0.10 percent for Grade 2 blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, racking / flush
jointing etc complete, as per drawing / specification etc, complete As per drawings and design supplied by architect and instruction given by
authority and E.I.C. For all civil, plumbing, electrical & infrastructure works.
Chapter 17 Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level and finished even and
127 17001A+17006 3026.00 smooth in (i)Cement mortar 1:3 (1-cement:3-sand) Sqm 153.67
Page - 136, 137 A) Ground Floor (For Ceiling, Beam bottom and sides)
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level and finished even and
128 2298.00 smooth in (i)Cement mortar 1:3 (1-cement:3-sand) Sqm 177.06
B) First Floor (For Ceiling, Beam bottom and sides)
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level and finished even and
129 2575.00 smooth in (i)Cement mortar 1:3 (1-cement:3-sand) Sqm 200.45
C) Second Floor (For Ceiling, Beam bottom and sides)
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level and finished even and
130 2456.00 smooth in (i)Cement mortar 1:3 (1-cement:3-sand) Sqm 223.85
D) Third Floor (For Ceiling, Beam bottom and sides)
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level and finished even and
131 2403.00 smooth in (i)Cement mortar 1:3 (1-cement:3-sand) Sqm 247.24
E) Fourth Floor (For Ceiling, Beam bottom and sides)
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level and finished even and
132 2433.00 smooth in (i)Cement mortar 1:3 (1-cement:3-sand) Sqm 270.63
F) Fifth Floor (For Ceiling, Beam bottom and sides)
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level and finished even and
133 314.00 smooth in (i)Cement mortar 1:3 (1-cement:3-sand) Sqm 294.02
G) Sixth Floor (For Ceiling, Beam bottom and sides)
Chapter 17 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering upto floor two
134 17002A 7879.00 level and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) Sqm 176.58
Page - 136 A) Ground Floor (For inside wall, verticle surface plaster )
Chapter 17 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering upto floor two
135 17002A+17007A 5612.00 level and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) Sqm 199.97
Page - 136, 137 B) First Floor (For inside wall, verticle surface plaster )
Chapter 17 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering upto floor two
136 17002A+17007A 5169.00 level and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) Sqm 223.36
Page - 136, 137 C) Second Floor (For inside wall, verticle surface plaster )
Chapter 17 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering upto floor two
137 17002A+17007A 4055.00 level and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) Sqm 246.75
Page - 136, 137 D) Third Floor (For inside wall, verticle surface plaster )
Chapter 17 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering upto floor two
138 17002A+17007A 15468.00 level and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) Sqm 270.14
Page - 136, 137 E) Fourth Floor (For inside wall, verticle surface plaster )
Chapter 17 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering upto floor two
139 17002A+17007A 5959.00 level and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) Sqm 293.54
Page - 136, 137 F) Fifth Floor (For inside wall, verticle surface plaster )
Chapter 17 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering upto floor two
140 17002A+17007A 407.00 level and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) Sqm 316.93
Page - 136, 137 G) Sixth Floor (For inside wall, verticle surface plaster )
Chapter 17 Providing 20 mm thick double coat mala cement plaster on interior brick / concrete work for plastering comprising of base coat of 12 mm thick
141 17017 9616.00 cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Sqm 272.48
Page - 138 Coarse sand) finished with trovel including scaffolding curing etc. complete.
Providing & laying 20 mm. thick sand face cement plaster Gutkha finish on walls up to 10mt. height and above ground level consisting of
mm. thick backing coating of C.M. 1:3 (1 cement : 3 sand) and 8 mm. thick finishing coat in C.M. 1:1 (1 cement :1 sand) etc. complete.
Providing and fixing Chicken wire mesh jali 16 x 24 or approved size of 22 gauge at junction of concrete and brick work / AAC Block work or
between different materials after making "V" grove between two different material surface and filled with rich cement mortar, nailing etc
complete for all floor, any height, all shape etc complete As per drawings and design supplied by architect and instruction given by authority
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and applying medium grain textured exterior finish, siloxane modified acrylic based, anti-mould, anti-algae, weather resistant, water
based coating system of approved imported make, of selected marble chip texture and approved shade as per 3D architectural drawings, applied
over properly prepared substrate including surface cleaning, crack filling, surface levelling with exterior grade putty where required, application
144 R.A-25 6255.00 of suitable exterior primer, followed by application of textured coating in required thickness and pattern using spray / trowel as per Sqm 1,419.05
manufacturer’s specification, ensuring uniform grain distribution and finish, including final protective top coat where specified, complete with
all scaffolding, labour, materials, T&P, lead and lift at all heights, curing, protection and cleaning, complete in all respects as per approved
drawings, manufacturer’s specifications and directions of Architect / Engineer-in-Charge for all height.
Chapter 18 Providing and applying Wall painting (three coats) with plastic emulsion paint of approved brand and manufacture on under coated wall surface
145 18031+18032 44987.00 to give and even shade including throughly brushing the surface free from mortor droppings and other foreign matter and sand paperd smooth Sqm 112.95
Page - 143 on new work to give an even shade.for all height
Finishing wall with weather proof low viscosity ultima exterior emulsion paint on wall surface (two coats) to give an required shape even shade
after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials.etc complete for all height
Applying two coats of acrylic lapy ( putty) & two coats of primer of approved brand and manufacture on new wall surface to give an even shade
including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth.
Providing cement vata (10 cm x 10 cm size) quarter round in cement mortar 1:1 including neat cement finishing, watering etc. complete.For all
149 5018 4359.00 Providing throating or plaster drip and moulding to R.C.C. Chhajja. Rmt 41.66
Providing & applying two Componant , non slumping , non-sagging, thixotropic epoxy bedding compond & adhesive compatible with for tiles
for coving at radius of 25 mm or as directed by the architect's/Engineer-in-charge make it fit for tiles inclusive of Labour, material and
Equipment etc. for all heights ,location, shape & size as directed by the architect/ engineer incharge etc. completed As per drawings and design
supplied by architect and instruction given by authority and E.I.C. (Actual Length shall be measured for payment.)
Metallic Wall Panels & Walkalbe Ceiling Panels
Providing, Designing, Supplying, Fabricating, and Installing of Metallic Wall Panels, Walkable Ceiling Panels, and Integrated Partition Systems
of proven quality and performance. All panels shall be high quality, tough, durable, and impact resistant, with a factory pre-painted smooth
finish. The painted surfaces shall be resistant to cleaning agents and suitable for frequent washing without any deterioration, discoloration, or
loss of finish. All materials used shall be rust-proof, corrosion-resistant, and inert to the development of micro-organisms. Wall and ceiling
surfaces shall neither emit nor retain particles of any nature, ensuring hygienic conditions. The surfaces shall be easy to clean and washable on a
regular basis without affecting the paint or surface integrity. The complete partition system shall be fully waterproof and watertight, including
all panel joints. The system shall consist of metal composite panels of 100 mm overall thickness with PUFF core density adequate to provide
structural stability, strength, and effective thermal insulation. The minimum metal sheet thickness shall be 0.65 mm to 0.70 mm, with sheets pre-
painted on all sides. All panel joints shall be rigorously sealed and watertight. Return air risers shall be integrated within the wall system,
provided flush with wall thickness, using panels of 0.65 mm to 0.70 mm thickness on both sides, pre-painted throughout, and matching the
ceiling panel material and paint quality. Filters, light fittings, air extract grills, and outward-opening access traps shall be flush-mounted. The
walkable ceiling shall include a galvanized suspension system as a standard feature. Aluminium or PU coving shall be provided at wall-to-
ceiling junctions, and panels shall be interconnected using a friction-type joint system.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and applying a single-component, waterborne modified polyurethane (PU) dispersion-based wall coating system, designed for interior
wall surfaces, complete as per manufacturer’s recommendations and technical data. The coating shall deliver a durable, hygienic, and semi-gloss
finish with a minimum dry film thickness of 120 microns. The system shall consist of surface preparation, priming, and application of PU top
coats to achieve the specified performance and appearance. Surface preparation shall ensure the substrate is clean, dry, sound, and free from
dust, oil, grease, and loose particles. Priming shall be carried out as required, with an approximate material consumption of 0.15–0.20 kg/m²,
ensuring uniform coverage and proper adhesion to the substrate. The PU top coat shall be applied in two coats, each with a material
152 R.A-27 27165.00 consumption of approximately 0.10–0.12 kg/m² per coat, achieving a total system thickness of 120 microns. Additional material shall be Sqm 523.18
allowed to account for surface porosity, surface profile, level variations, and application wastage. Application shall be carried out under
controlled environmental conditions, with ambient and substrate temperatures maintained between +15°C (minimum) and +30°C (maximum),
and relative air humidity not exceeding 80%. The substrate temperature shall be at least 3°C above the dew point to prevent condensation and
blooming of the coating. Substrate moisture content shall be visibly damp-free, with a maximum of 18% wood moisture equivalent, and no
rising moisture as per ASTM polyethylene sheet test. Overcoating intervals shall be approximately 8 hours minimum at +20°C and 6 hours
minimum at +30°C, with a maximum overcoating window of 48 hours. All application times are approximate and subject to ambient
temperature and humidity variations.
Providing and fixing 1200 mm height aluminium powder coated railing with frosted/clear toughened glass panels, comprising aluminium
framework of approved section and design, powder coated in approved colour and finish, including 12 mm thick frosted/clear toughened safety
glass panels, edges polished and free from defects, fixed between aluminium members, consisting of top and bottom rails of size 50 mm ×
mm aluminium section, vertical posts of size 50 mm × 50 mm aluminium section spaced at maximum 1200 mm centre to centre, powder coated
glass clamps suitable for 12 mm glass, base plate of size 100 mm × 100 mm × 6 mm thick securely anchored to RCC / structural member using
anchor bolts and chemical fasteners, including rail brackets and necessary fixing accessories, installation of glass panels with clamps, proper
alignment, plumbing and levelling, sealing joints with approved silicone sealant, ensuring smooth powder coated finish, scratch free frosted
glass surface, structural stability and safety compliance as per relevant standards and codes, including all labour, materials, hardware, T&P, lead
and lift, scaffolding, wastage and incidentals, complete in all respects as per approved drawings, specifications and directions of Architect /
Engineer-in-Charge.
Providing and fixing aluminium powder coated hand railing system, comprising 50 mm diameter top rail with intermediate supports of 37.5 mm
diameter placed at maximum 1.00 metre centre to centre, installed along staircase waist slab side walls and over ramp parapet walls, including
fabrication, welding, grinding, buffing, polishing and forming required curvature wherever specified in drawings, complete with balusters,
154 R.A-29 138.00 brackets, supports, horizontal members, base plates and all necessary fixing accessories, nuts, bolts and fasteners, properly anchored to RCC / Rmt 1,528.65
masonry substrate with suitable mechanical / chemical fasteners, ensuring correct alignment, level and structural stability, smooth powder
coated finish free from dents and scratches, including all labour, materials, T&P, scaffolding, lead and lift, wastage and incidentals, complete in
all respects as per approved drawings, specifications and directions of Architect / Engineer-in-Charge.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other
Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood
powder/ rice husk/wheat husk) and non toxic additives (maximum oxicity index of 12 for 100 gms) fabricated with miter joints after star headed
SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge),minimum
compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of
155 R.A-30 725.00 being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia Rmt 841.28
and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be including). Note: For WPC solid
door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on
plus side shall be acceptable but no extra payment on this account shall be made. applying PVC solvent cement and screwed with full body
threaded Complete As per drawings and design supplied by architect and instruction given by authority and E.I.C.
1) Frame size 45 x 85 mm
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board
laminted with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and
bathroom/kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and
natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum
density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus
of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof,water/moisture proof
and fire retardant including stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws, stainless steel butt hinges
of required size with necessary full body threaded star headed counter sunk S.S screws, Handles, Stopper, Door closer, Tower bolt all As per
drawings and design supplied by architect and instruction given by authority and E.I.C.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and fixing of Anodised Aluminium (Matt finish) frame work (Horizontal and verticals , Styles and rails, ball bearing) for Doors/
window/ventilation/alluminum partition with required Domal sections including fixing all items and hinged / pivoted arrangements for
operation of shutters and labour cost for fixing of door fittings and locks including all items and contingencies described above complete
(Aluminium beadings and glazing clips & section measured under this item only) NOTE: All fitting works shall be carried out as per I.S.
specifications including cost of necessary rivets, screws, lugs, scaffolding, rubber gaskets etc., complete all generally as per drawings. The sizes
of the components should confirm as per details in drawings. Providing and fixing at all heights / in all floors with all leads. Colour Anodised
Aluminium doors / windows / partitions manufactured from best extruded Aluminium sections confirming to ISI cut to length, joints mitred and
corners grinded with joints water proof the outer frame and shutter frame stiffened with corner angle and strips provided for in the frame for
fixing the frame to R.C.C Columns / masonry/Granite Frame on sides, R.C.C lintels/Granite Frame on top and P.C.C sills or floor at bottom, the
frame work fixed with standard approved fastenings all generally as per details shown in drawings and specification with all the sections
pretreated for removal of any rust & scales and prevention of further rust/scale formation and coated with greasy materials for non-adherence of
mortar or any other sticky materials and this coat to be removed after installations 1)Sheet metal screws, wool pile and aluminium angle corner
cleat of required thickness and of full width, etc. for assembling the frame and shutter; 2)Glazing clips for receiving infill panel for Double
Glazed Unit (DGU), any type of Glass, Compact Sheet, Louvers; 3) Best quality wool pile where ever shutter touches the frame; 4) Anchor
fasteners for fixing the frame assembly to the RCC or Granite or masonry surfaces etc. complete.
Note:-As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing frosted glass /Texture Glass of any size, any shape and specified thickness in frame and shutter work with necessary
cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/silicon sealant/structural sealant of 3M
158 R.A-33 152.00 tape on the periphery of the glass as per the required thickness etc. complete a tall floors/alllevels/all heights as per the directions of Architect. Sqm 1,237.25
Actual installed quantity shall be measured and paid. Rate shall be inclusive of all type of wastage. etc, completed as per drawings and design
supplied by architect and instruction given by authority and E.I.C.(a) 6 mm thick
Providing and fixing Tinted Float Glass of any size, any shape and specified thickness and SHGC velue 25 % in frame and shutter work with
necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/silicon sealant/structural sealant
159 R.A-34 256.00 3M tape on the periphery of the glass as per the required thickness etc. complete a tall floors/alllevels/all heights As per drawings and design Sqm 1,287.75
supplied by architect and instruction given by authority and E.I.C.. Actual installed quantity shall be measured and paid. Rate shall be inclusive
of all type of wastage. (a) 5 mm thick
Providing and fixing Compact Sheet of dark maroon colour in aluminium frame and shutter work with necessary cutting of sheet, single side,
double side coloured as per drawing & specifications including providing and fixing EPDM quality rubber/silicon sealant/3M tape/screwing on
160 R.A-35 1890.00 the periphery of the sheet as per the required thickness etc. complete at all floors/all levels/all heights As per drawings and design supplied by Sqm 1,201.90
architect and instruction given by authority and E.I.C. Cut edges of the compact sheet shall be provided with masking tape. Actual installed
quantity shall be measured and paid. Rate shall be inclusive of all type of wastage.(a) 6 mm thick
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
General Notes for Hardware : Supplying and fixing heavy quality fixture sand fittings for doors, windows, ventilators, partition wall, cabinets
with necessary screws, nails, machine pins etc. at all floor/all levels/all heights complete. The fittings and fixtures hardware . The fixture &
fastenings shall be provided as under : Providing & fixing heavy duty"Euro profile Mortise Dead lock"(12.6cm 1CK brass)with minimum 6keys
in door/window with necessary screws and as per drawing, complete.
Providing & fixing SS 304 grade Baby latch" Door Bolt" size of 3.5"with hair line finish with necessary S.S. Screws sand as per drawing,
complete As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing & fixing heavy quality SS AISI 316 grade "Butt Hinge with 4 Bearing"of 102 x 76 x 3mm with necessary S.S. Screws and as per
drawing, complete As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing, supplying, fixing and installation of Aluminium DGU Sliding Window made from Domal Series Sections comprising 3-Track frame
section (21376) of size 80 × 45 × 1.5 mm and shutter section (21967) of size 67.4 × 27 × 1.8 mm, fitted with Double Glazed Unit (DGU) clear
glass of 6 mm + 12 mm air gap + 6 mm, complete with approved colour anodized finish on aluminium profiles, including all required
accessories such as rollers, handles, interlocks, gaskets, wool pile, screws, fasteners and necessary fittings, including cutting, fabrication,
164 R.A-39 422.00 glazing, assembling and installation at site, complete in all respects as per approved drawings and specifications.The work shall include proper Sqm 10,310.64
sealing between frame and structure to prevent air and water infiltration. The entire work shall be executed as per approved drawings,
specifications and directions of the Engineer-in-Charge, complete in all respects, and the rate shall include all materials, labour, tools, plant,
machinery and incidentals necessary for satisfactory completion of the work.
DGU Glass Brand: Saint Gobain or Equivalent
Providing, supplying, fixing and installation of Aluminium DGU Fixed Window fabricated from Aluminium Sections comprising Outer Frame
Section (14011) size 25.80 × 25.40 × 1.5 mm along with Fixing Square Pipe Section (14470) size 25 × 25 × 1.5 mm, designed to accommodate
Double Glazed Unit (DGU) clear glass of 6 mm + 12 mm air gap + 6 mm, with approved colour anodized finish on aluminium profiles,
including all required accessories such as EPDM gaskets, beading, screws, fasteners and necessary fittings, including cutting, fabrication,
165 R.A-40 73.00 glazing, assembling and installation at site, complete in all respects as per approved drawings and specifications.The work shall include proper Sqm 6,873.76
sealing between frame and structure to prevent air and water infiltration. The entire work shall be executed as per approved drawings,
specifications and directions of the Engineer-in-Charge, complete in all respects, and the rate shall include all materials, labour, tools, plant,
machinery and incidentals necessary for satisfactory completion of the work.
DGU Glass Brand: Saint Gobain or Equivalent
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing, supplying, fixing and installation of aluminium DGU Openable Window fabricated from Aluminium Sections comprising Outer
Frame Section (21635) size 52 × 44.5 × 1.4 mm, Shutter Section (21636) size 52 × 66 × 1.4 mm, and Fixing Clip (19469) size 32 × 26 ×
mm, fitted with Double Glazed Unit (DGU) clear glass of 6 mm + 8 mm air gap + 6 mm, with approved colour anodized finish on aluminium
sections, including all required accessories such as hinges, handles, EPDM gaskets, screws, fasteners and necessary fittings, including cutting,
166 R.A-40A 12.00 fabrication, glazing, assembling and installation at site, complete in all respects as per approved drawings and specifications.The work shall Sqm 8,935.88
include proper sealing between frame and structure to prevent air and water infiltration. The entire work shall be executed as per approved
drawings, specifications and directions of the Engineer-in-Charge, complete in all respects, and the rate shall include all materials, labour, tools,
plant, machinery and incidentals necessary for satisfactory completion of the work.
DGU Glass Brand: Saint Gobain or Equivalent
Providing, supplying, fixing and installation of Fixed Double Glazed Unit (DGU) Glass Panels consisting of 12 mm toughened glass + 6 mm
toughened glass, factory-sealed with appropriate spacer and desiccant to form an insulated glazing unit. The glass shall be installed in a 63 x
x 1.2 mm aluminium pipe frame, complete with necessary gaskets, sealant, fixing accessories and supports. The aluminium frame shall be
167 R.A-40B 30.00 finished in anodized colour coating of approved shade. The work includes cutting, fabrication, edge finishing, transportation, installation and Sqm 7,836.08
sealing of the glass panels to ensure proper alignment, weather tightness and structural stability.
Complete in all respects as per drawings, specifications and direction of the engineer/architect.
DGU Glass Brand: Saint Saint Gobain or Equivalent
Providing & fixing SS 316 Medium Duty Hydraulic Floor Spring for 80to130KG with cover plate & adjustable concealed casted top pivot of
any color with necessary screws and as per drawing,complete as approved by Architect. Rate shall be inclusive of cutting off loor neatly,
168 R.A-41 78.00 grouting the floor spring & cleaning/ polishing the floor & maintaining in good working condition till defect liability period with one year Nos. 5,050.00
Note:-As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing & fixing SS 304 grade of brush/satin finish specified size Tower Bolt with necessary screws and as per drawing, complete As per
169 R.A-42 320.00 drawings and design supplied by architect and instruction given by authority and E.I.C. Nos. 858.50
a) 18" x 10mm (square)
Providing & fixing SS AISI 316 grade of glossy/satin finish specified size Push-Pull Handle in pairs with necessary screws and as per drawing,
170 R.A-43 83.00 complete Note:-As per drawings and design supplied by architect and instruction given by authority and E.I.C. Nos. 2,222.00
a) 22mm (diameter) x 300mm
Providing and Fixing heavy duty S.S. Door Closer As per drawings and design supplied by architect and instruction given by authority and
Providing and fixing Stainless steel mosquito net jali ,wire of I.S gauge designation 85-G with wire of 0.56 mm fix in aluminium door, window,
ventilator shutters of any size, any shape with etc all complete at all floors/all levels/all heights As per drawings and design supplied by
architect and instruction given by authority and E.I.C. Actual laying installed Jali shall be measured. (Cost of aluminium snap beading shall be
paid in basic item)
Providing and fixing M.S. grill of required pattern top wooden frames of windows etc. with M.S.. flats at required spacing and frame alround
square or round headed bolts and nuts or by screws.including applying a priming coat of red lead paint and two coats of oil painting etc
complete (A)Plain grill
Note:-As per drawings and design supplied by architect and instruction given by authority and E.I.C.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing, supplying and fixing Flush Type Clean Room Door fabricated from GI powder coated sheets, overall door thickness 44.5 mm,
constructed using 0.80 mm thick GI sheets on both sides with 5 mm thick toughened glass flush vision panels fixed using approved 3M / Saint-
Gobain or Equivalent adhesive tape, and filled with PUF insulation for thermal and acoustic performance. The door shall be complete with GI
174 R.A-47 132.00 powder coated door frame of size 80/60 × 50 × 1.75 mm thickness, including all necessary hardware such as 3 Nos. stainless steel ball bearing Sqm 23,490.87
hinges per leaf, concealed flush bolts, airtight sealing gasket (seal) for maintaining clean room airtightness, and all required accessories. The
item shall include fixing in position, alignment, finishing and making good of adjoining surfaces, complete in all respects as per approved
drawings and directions of the Engineer-in-Charge. (Brand Name: Anjani / Shaktimat or Equivalent)
Providing and fixing of approved make Trap door with galvanised steel. Doors should be finished in Powder Coating with film thickness of
microns approx. in desired RAL Shades. The manufacturer company must be TUV Nord ISO 9001-2015 certified ACODOR (koleshvari Infra)
175 R.A-48 315.00 trap door and must be made from galvanised steel sheet. door must be concealed type of hinges and appropriate provision for hanging from Sqm 6,030.97
celling. appropriate locking must be provided.frame and door must made from minimum 1 mm glavanised steel.
Note:-As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Designing, Providing & fixing glass work at entrance having glass panels including 4 openable , central and fixed side panels. Assembly shall
be made of 12 mm clear heat strengthened glass of approved colour, frameless door shutter with approved floor springs & patch fittings, to
support / hold glass to withstand wind pressure of 150 kg/Sqm, stainless steel handles 430mm x 30mm (S.S.S min), patch locks, joints should
be filled with transparant approved silicon sealant to ensure stability & water tightness of door including fine stoppage including approved
heavy duty bottom rail / door section of anodized Aluminum sections etc.as per specification , approved approved drawings and As per
drawings and design supplied by architect and instruction given by authority and E.I.C.
Supply and fixing Wooden lead lined door frame for Single /Double leaf to required sizes of The frame should be Single rebate profile of size
120 x 70 mm made out of Hardwood Mirandi. Frames shall be Butt jointed and field assembled with self tabs. The Shutter & Frame Shall be
fully lead lined of min of 3 MM lead Sheet with 99% purity and as defined by AERB. All provision should be mortised, drilled and tapped for
receiving appropriate hardware. Rubber door silencers should be provided on the striking jamb. Frames should be fixed by anchor fasteners for
installation on a finished plastered masonry wall opening fixed in existing opening with the help of anchor fastener of appropriate size as per
direction of Engineer in Charge. The manufacturer should be an ISO certified and IGBC registered member.Providing and fixing wooden
Leadline Door leaf 44 mm thick with commercial ply & laminate both side with or without vision lite.incase vision lite is required it shall be
only Lead Glass as recomomnded by AERB/DRC . The internal construction of the door should be rigid with lead line of 2mm thick all across
the inside of the exposed surface. In addition the door should have a basic infill ROCK WOOL with necessary reinforcement both on top and
bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks,
and door closers as per ANSI Standard. including Providing and fixing SS Ball Bearing Hinges of size 100 x 75 x 3mm complete with SS
Screws ( 4 Nos. per panel ), Mortise Dead Lock, SS D Type Pull Handle of size 300mm mm Long, door closers, Stainless Steel 304 grade
300mm Long Tower Bolt, anchor fasteners of maximum 120mm lengths etc complete As per drawings and design supplied by architect and
instruction given by authority and E.I.C. (Brand Name: JC Fire Door or Equivalent)
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and fixing Structural Glazing with using the 17 Micron anodised of approved colour alluminium section as transium, mullium of size
63.5mm x 38.1mm x 2 mm with using 6 mm thick reflective structural glass (including toughning) and fixed with silicone sealant and spacer tap
and at corner sealed neoprene foam dust and Air sealed gasket mirred including scaffolding etc.complete with all necessary fitting and fixtures
including openable window. etc complete as per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing in position collapsible steel shutters with vertival channels 20 mm x 10 mm x 2 mm braced with flat iron diagonals 20 mm
x 5 mm size with top & bottom rails of T iron 40 mm x 40 mm x 6 mm with 38 mm diameter steel pulleys complete with bolts, nuts, locking
arrangements, stopper handles including applying a priming coat of red lead paint.
Note:-As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing, supplying, preparing, and installing a complete high-performance cementitious polyurethane (PU) Clean Room Flooring System with a
nominal thickness of 4.0 mm, including all materials, labor, equipment, surface preparation, priming, scratch coating, PU floor topping, coving, joint
treatment, curing, testing, and all incidental works, complete in all respects and in strict accordance with the manufacturer’s instructions, applicable
standards, and clean room requirements. The flooring system shall be designed for the highest order of durability, offering excellent resistance to
abrasion, chemical attack, impact, and physical aggression, and shall be anti-bacterial, anti-fungal, UV resistant, seamless, hygienic, non-dusting, and
suitable for frequent washing and use of approved clean room cleaning agents, providing a smooth matt, impervious, and easy-to-clean finish. All
horizontal and vertical corners, wall-to-floor junctions, upstands, columns, and similar details shall be finished with same-color polyurethane coving
to eliminate dirt traps. Substrate preparation shall include mechanical removal of laitance, curing membranes, sealers, dust, oil, grease, paint, plaster,
corrosion deposits, algae, and all unsound or contaminated materials by shot-blasting, grinding, or light scrabbling to expose sound concrete,
followed by thorough vacuum cleaning. New concrete substrates shall be minimum RC30 grade as per BS 8500-2:2002, free from water-repellent
admixtures, achieving a rebound hammer value above 25 or surface tensile strength exceeding 1.5 MPa, and ground-bearing slabs shall include a
damp-proof membrane in accordance with CP102. Existing concrete floors shall be similarly prepared, with oil and grease contamination removed
by mechanical, steam, biological, or high-pressure water methods, repaired where defective, and provided with surface-applied membranes or
pressure-relief measures where hydrostatic pressure is anticipated. A cementitious PU scratch coat of approximately 1.0 mm shall be applied to
prime and seal the substrate and cured for 12–48 hours, followed by a flow-applied cementitious PU topping of 4.0 mm, mixed using a forced-action
mixer and achieving specified Compressive Strength (ASTM CI09) (28 days – 50.8 MPa), Tensile Strength (BS6319-7) (28 days – 6.8 MPa),
Flexural Strength (BS6319-3) (28 days – 17.9 MPa), Slip-Resistance (ASTM E303) Dry, and impact-resistance(ASTM 02794), Joules for 3mm
thickness (8.1) & 6mm thickness (10.8) with anchorage grooves formed at edges, joints, drains, and doorways. Priming shall be carried out using
two-component primer, PU coving includes three-component water-based polyurethane coving mortar with proper substrate preparation and priming
as per manufacturer’s datasheet, applied wet-on-wet at a coverage of 1.8–2.0 kg/m²/mm before primer curing. The coving shall be finished with two
coats of three-component water-based high-build polyurethane sealer, each at 200 microns WFT.All expansion and construction joints must consider
the removal of dust, loose or contaminated material, plaster, oil, grease, paint, corrosion, or algae, with oil/grease deposits mechanically. The priming
should be applied with Primer No. 20 & Colpor 200 with 30 minutes to 2 hours & PU sealant should be provided at the designated joints using over
Expancel backer rod on Hydrocel XL filler board at expansion joints, complying with BS 5212:1990 and US Federal Spec SS-S 200E:1984, with
30% movement accommodation in butt joints.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying Double Charged Vitrified Matt Finish in Floor in 2' x 4' (Thickness: 10 mm) with water absorption less than 0.08% and
conforming to IS:15622, of Somani / Johnson or Equivalent brand, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1
cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments
181 R.A-53 1027.00 etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of Sqm 1,564.46
required thickness, leveling system and rubber mallet for placing the tiles gently and easily including grouting the joints with white cement and
matching pigments etc., complete. Colour and shade as approved by architect. All joints filled with epoxy grout (avg. 4*10 to12 mm).Rate
includes for all lead & lift . Double Charged Vitrified Matt Finish of size 600 x 1200 mm For Light Shade.
Providing and laying Double Charged Vitrified Matt Finish in Floor in 2' x 4' (Thickness: 10 mm) with water absorption less than 0.08% and
conforming to IS:15622, of Somani / Johnson or Equivalent brand, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1
cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments
182 R.A-54 514.00 etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of Sqm 1,564.46
required thickness, leveling system and rubber mallet for placing the tiles gently and easily including grouting the joints with white cement and
matching pigments etc., complete. Colour and shade as approved by architect. All joints filled with epoxy grout (avg. 4*10 to12 mm).Rate
includes for all lead & lift . Double Charged Vitrified Matt Finish of size 600 x 1200 mm For Dark Shade.
Providing and laying 25 mm thick premium grade, machine cut, mirror polished Kota stone slabs of size 600 × 600 mm, uniform in colour,
texture and density, free from cracks, veins and surface defects, in flooring, skirting, risers, steps and dado, laid over 20 mm average thick
cement mortar bed (1:6) (1 cement : 6 coarse sand), including cleaning, wetting of base, cement slurry bonding coat, proper bedding, leveling,
alignment and compaction complete, machine grinding with multi stage diamond pads, final mirror polishing to achieve smooth, even, high
gloss finish, chamfered edges, proper curing, surface protection, cutting and fitting around columns, frames and fixtures, including all labour,
materials, T&P, lead and lift, wastage and incidentals, complete as per drawings, specifications and directions of Engineer-in-Charge.
Providing and laying (2' x 4') 600 × 1200 mm Ultra-Premium Full Body Glazed Vitrified Tiles, rectified edges, uniform thickness (minimum
8–10 mm) of Somani / Johnson or Equivalent Brand, water absorption less than 0.5%, high gloss / satin finish as approved, in dado work on
walls, fixed using high performance Polymer Modified Tile Adhesive (Unive Make or Equivalent) of approved make, applied with notched
trowel over properly prepared, levelled, cleaned and primed surface, including surface hacking / roughening wherever required, maintaining
184 R.A-56 18176.00 uniform 4 mm wide joints using spacers, ensuring proper alignment, plumb, line and level, cutting and fitting around corners, edges, openings Sqm 2,108.88
and fixtures, back buttering of tiles where necessary to avoid hollowness, filling joints with approved stain resistant epoxy grout of matching
shade, removal of excess grout, final cleaning with non-acidic solution, curing and protection of finished surface, including all labour, materials,
T&P, scaffolding, lead and lift, wastage and incidentals, complete in all respects as per approved drawings, specifications and directions of
Architect / Engineer-in-Charge.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and fixing 19 mm thick × 65 mm wide round moulded “Telephone Black” granite pencil patti with bevelled edge finish, machine cut
and mirror polished, uniform in shade and texture, free from cracks and surface defects, fixed over top edge of vitrified tile dado as shown in
drawings, bonded using high performance polymer modified tile/stone adhesive (Unive Make or Equivalent) over properly prepared, cleaned
and levelled substrate, including back buttering of granite where required to ensure full contact and avoid hollowness, proper alignment, line
and level, cutting and finishing at corners and junctions, filling all joints with approved colour matched epoxy grout, finishing with sharp flush
joints, cleaning excess grout, final surface cleaning with non-acidic solution, curing and protection, including all labour, materials, T&P,
scaffolding, lead and lift, wastage and incidentals, complete in all respects as per approved drawings, architectural details and directions of
Authority / Engineer-in-Charge.
Providing and laying full body Double Charged Vitrified Matt Finish Anti-Skid Tiles, 8–10 mm thick, size (2' x 4') 600 × 1200 mm, rectified
edges, water absorption less than 0.5%, of Somani / Johnson or Equivalent brand uniform in colour and shade as approved by Architect, in
flooring, laid over 20 mm average thick cement mortar bed (1:6) (1 cement : 6 coarse sand) or levelling mortar 1:1.5 as specified, on new
surface, including preparation, cleaning and wetting of base, cement slurry bonding coat, proper bedding, alignment, levelling and compaction
complete after dismantling and removal of existing flooring including disposal of debris as directed, maintaining uniform joints of 4 mm width
using spacers, filling joints with approved colour matched epoxy grout (average 4 mm × 10–12 mm), finishing with flush pointing, removal of
excess grout, final cleaning without acid damage, curing and protection of finished surface, including all labour, materials, T&P, lead and lift,
wastage and incidentals, complete in all respects as per approved drawings, specifications and directions of Authority / Engineer-in-Charge.
Providing and laying 18 mm thick premium quality Italian marble slabs, machine cut, calibrated, mirror polished, uniform in colour, grain and
texture, free from cracks, pits, resin patches and visible defects, laid in required pattern in linear portions of the building as per approved
architectural drawings, over 20 mm average thick cement mortar bed (1:4) (1 cement : 4 coarse sand), including preparation, cleaning and
wetting of base, cement slurry bonding coat, proper bedding, alignment, levelling and compaction complete, jointed with white cement slurry @
4.4 kg per Sq.m, joints finished with white cement slurry admixed with matching pigment to achieve seamless appearance, machine grinding,
multi-stage rubbing and mirror polishing, edge dressing, cutting and fitting around columns, frames and fixtures, curing, surface protection and
final cleaning without acid damage, including all labour, materials, T&P, lead and lift, wastage and incidentals, complete in all respects as per
approved drawings, specifications and directions of Authority / Engineer-in-Charge.
Providing & laying average 40mm-100mm thick wired finish/float finish screed of cement concrete 1;2;4 ( 1 cement : 2 coarse sand : 4 graded
stone agreegate 20 mm nominal size ) as base material for any type of flooring works in building, general development area works etc. laid to
achieve proper slope or 0-0 levelled surface and curing complete excluding cost of formwork at any type of surface ,all floors ,all levels, all
heights As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Chapter 14 Providing and laying cement concrete flooring 1:2:4 (1-cement : 2-coarse sand : 4-graded stone aggregate 20mm nominal size) laid in one layer
189 14015BA 128.00 and finished with a floating coat of neat cement. Sqm 351.56
Page - 128 (B) 50mm thick.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and fixing sandwich type granite counter platform, comprising base layer of 25 mm thick polished Kota stone slab, properly bedded,
levelled and supported over intermediate masonry / RCC supports in cement mortar, and supplying and fixing 18 mm thick first quality
“Telephone Black” granite slabs, machine cut, mirror polished, full round moulded at exposed edges, uniform in colour and texture, free from
cracks, laminations and visible defects, fixed on top surface, side facia and vertical front strip as shown in drawings, bonded using cement
190 R.A-62 584.00 mortar and high performance stone adhesive to ensure full contact and structural stability, including proper alignment, line and level, edge Sqm 5,896.19
finishing, cutting and shaping for sink openings of any size, provision for plumbing fixtures, polishing of cut edges, filling all joints with
approved colour matched epoxy grout, finishing smooth, curing, protection and final cleaning complete, including all labour, materials,
scaffolding, T&P, lead and lift, wastage and incidentals, complete in all respects as per approved drawings, specifications and directions of
Authority / Engineer-in-Charge.
Providing and laying 18 mm thick “Telephone Black” or as per selection by architect granite slabs, machine cut, one side mirror polished,
uniform in colour and texture, free from cracks, veins and surface defects, in flooring, laid over 20 mm average thick cement mortar bed (1:6) (1
cement : 6 coarse sand) or levelling mortar 1:1.5 as specified, including preparation, cleaning and wetting of base, cement slurry bonding coat,
proper bedding, alignment, levelling and compaction complete, joints filled with grey cement slurry and finished flush, including machine
rubbing and final polishing to achieve smooth and even surface, forming edge moulding as per approved architectural pattern, including making
two decorative grooves as detailed in drawings, cutting and fitting around columns, frames and fixtures, curing, protection and final cleaning
without acid damage, including all labour, materials, T&P, lead and lift, wastage and incidentals, complete in all respects as per approved
drawings, specifications and directions of Authority / Engineer-in-Charge.
Providing and fixing 18 mm thick “Approved Shade” granite slabs, machine cut, mirror polished, uniform in size, colour and shade, of approved
make, free from cracks, veins and surface defects, in skirting, risers of steps, dado, wall cladding, sills, jambs of doors, windows and ventilator
frames, fixed over properly prepared surface using high performance stone adhesive (Unive Make or Equivalent), including application of
minimum two coats of approved construction chemical bonding agent as per manufacturer’s specification, ensuring proper line, level, plumb
and alignment, edge rounding / chamfering as per architectural detail, cutting and fitting at corners and junctions, filling all joints with approved
colour matched cement putty, finishing with sharp flush joints, final rubbing and polishing, cleaning of surface with approved mild solution (no
acid damage permitted), curing and protection, including all labour, materials, scaffolding, T&P, lead and lift, wastage and incidentals, complete
in all respects as per approved drawings, specifications and directions of Authority / Engineer-in-Charge.
Providing and fixing 25 mm thick machine cut, free edge, double polished Kota stone slabs for shelves, in single piece of maximum 1.50 m
length, uniform in colour and texture, free from cracks, laminations and surface defects, fixed in cupboards and wall recesses, including cutting
grooves in masonry / RCC walls to required depth, embedding slab ends in cement mortar, bedding with neat cement slurry to ensure proper
bond, maintaining true line, level and alignment, edge dressing and polishing of exposed edges, finishing smooth and even, curing and
protection, including all labour, materials, T&P, lead and lift, wastage and incidentals, complete in all respects as per approved drawings,
specifications and directions of Authority / Engineer-in-Charge.
Providing & laying rough chiseled dressed stone flooring over 20 mm.(average) thick base of cement mortar 1:5(1 cement : 5 coarse sand) or
L.M. 1:1.5 including pointing with cement mortar 1:2 (1 cement:2 stone dust) etc. complete. [A] 25 mm. thick.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying approximately 16 mm thick exterior grade heavy duty pavement tiles 300x300mm or higher size as selected by architect,
uniform in colour and texture, of Somani / Johnson or Equivalent Brand, suitable for exterior pedestrian use, laid over 20–25 mm thick
cement mortar bed (1:3) (1 cement : 3 coarse sand), bedding thickness varying as per site levels and slopes, over properly prepared and
compacted base, including cleaning and wetting of surface, laying tiles in true line, level and required pattern as per architectural drawings,
195 R.A-66 128.00 bonding with grey cement slurry, maintaining 4–5 mm wide joints using spacers, or providing specified open joints / pebble stone filled gross Sqm 924.79
joints as per approved architectural scheme, no extra payment for forming such joints, pointing joints with approved ready-made polymer joint
sealer, finishing with ruled and sunk pointing, maintaining proper surface alignment and drainage slope, cutting and fitting at edges, corners and
around fixtures, curing, protection and final cleaning, including all labour, materials, T&P, lead and lift, wastage and incidentals, complete in all
respects as per approved drawings, specifications and directions of Authority / Engineer-in-Charge.
Providing & laying china mosaic flooring of Somani / Johnson or Equivalent Brand for plain and curved surfaces at floor, dado, otta etc.
comprising of 20 to 25 mm size broken pieces of ceramic/ glazed tiles (only white colour) laid over 1:6 cement mortar bedding including
Chapter 14 applying cement slurry at the rate of 2.75 kg per Sq.m. on plain or sloped surfaces and filling joints with white cement. The flooring/ dado shall
196 14035 2940.00 be tampered with wooden rammer not exceeding 2 Kg in weight to bring the mortar up to the surface including rounding of the junctions and Sqm 747.29
Page - 130 extending them upto 15 cm along the parapet wall. The rate shall include any type of bands, vata, any colour, any pattern or design as per
drawing, curing, cleaning with water and oxalic acid etc. complete as sample approved by Architect/ EIC. (Only plan area shall be measured
including vata upto 150mm height). Rates should be inclusive of acid washing and vata.
Providing & laying average 18-20mm thick double coat water proof smooth/ wired finish cement plaster (For terrace) , 12 to 15mm thick first
coat in CM 1:3 (1 cement : 3 coarse sand) by spraying, second coat of 6mm of CM 1:3 (1 cement : 3 fine sand) and mixing non shrinkage
compensating waterproofing admixture (Add 330 grams of one pouch with 1 bag of 50 kg of cement Bag-As per manufracurers specifications)
in both coats including finishing with a flooting coat of neat cement slurry etc complete for all floor. and shall be guaranteed for minimum
197 R.A-67 3434.00 period of 10 years after handing over the completed building by the main contractor to be finished as directed. Stamp paper guarantee 10 years Sqm 369.99
to be furnished before receiving any payment from the client. Waterproofing powder & liquid of approved make recommended proportions is to
be applied before each coat and final finishing coat. (Item shall be operated for water retaining structures, sunks, basement walls and other
places specified As per drawings and design supplied by architect and instruction given by authority and E.I.C. (For Terrace PU Waterproofing
protective layer). (Unive Make or Equivalent)
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and applying hydrophilic crystalline based waterproofing system In two coat application. The application to be done from
+ve(positive) side on a wet open pore green concrete surface at coverage of 0.8to1kg/sqm as per manufacturer specification. It should be
hydrophilic in nature, should be able to grow crystals year after year to seal microcracks. The product should confirm to DIN1048 part5 and
should provide in depth crystallization.The material and application warranty to be given by manufacturer’s authorized distributor/applicator on
prescribed format for10 years. Note:- Treated area should be screeded using hydrophilic crystalline admixture KIM(Krstol Internal Membrane)
198 R.A-68 1395.00 @ 2% for be stresults:-Application of crystalline coating to be done within 7days of casting of concrete All the waterproofing activities shall be Sqm 500.83
carried out by in-house application company of the principal material manufacturer and provide a written corporate Supply Apply Corporate
Warranty from the principal manufacturer that all work executed will be free from defects in materials, workmanship and free of leaks for a
period of 10 years from the date of Work Completion, unless resulting from structural defects or causes other than the work of this section. Said
defects shall be remedied by the principal manufacturer for the period of the warranty without additional cost to the owner for waterproofing
material only. (For Sunken area waterprrofing) (Unive Make or Equivalent)
Providing and laying 115mm over deck insulation over terrace water proofing of ex-foliated vermiculite of MFV/ Porosile / Vermiplast/unive or
equivalent as per approved make for roof insulation in the ratio of 1 :6 (1 cement : 6 Ex foliated vermiculite (by volume)). Density of Ex
foliated vermiculite shall be 212 kg/cum. The cement shall be mixed with the ex foliated vermiculate in dry stage & then minimum qty of water
shall be added. After screeding the ready mixed material in specified thickness, curing shall be carried out at least for 7 days by sprinkling of
required quantity of water so that surface remains damp and not to be done by ponding or flooding. The work includes cleaning of the surface
with wire brush thoroughly necessary scaffolding finishing the top surface as best workmanship like manner as per the manufacturers
specifications.All the waterproofing activities shall be carried out by in-house application company of the principal material manufacturer and
provide a written corporate Supply Apply Corporate Warranty from the principal manufacturer that all work executed will be free from defects
in materials, workmanship and free of leaks for a period of 10 years from the date of Work Completion, unless resulting from structural defects
or causes other than the work of this section. Said defects shall be remedied by the principal manufacturer for the period of the warranty without
additional cost to the owner for waterproofing material only.etc complete As per drawings and design supplied by architect and instruction
given by authority and E.I.C.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying PU- Liquid Applied polyurethane membrane terrace waterproofing system, Clean the RCC surface of all loose particles,
dust, cement laitance etc. preferably done using floor polishing machine or any other mechanical tools. Surface preparation is of prime
importance as the degree of performance of the coating is directly proportional to the extent of cleaning Identify the cracks, construction joints,
honeycombed areas etc. on the RCC surface. Injection grouting shall be done at construction joints with providing and injection non shrink
cementations grout by mixing – 2 pouches (330 gms. Each) and 50 kgs of cement and sufficient water for flow ability, Grouting the same under
pressure in pre-drilled holes by grouting pump etc. After grouting is completed after 24 hours, cut the nipples and seal it with PMM.Prepare a
coving at the construction joints upto 250 mm on either side of the joints using PU- Liquid Applied polyurethane membrane with min
elongation of > 600 % (ASTM D412) with pH 8.5-10 and 90%+/- 3% and conforming to DIN 1048 for zero permeability at 7 bars of water
pressure. Apply PU PRIMER at the junction and allow it to dry for min 30-40 min. After primer has cured apply 1st coat of PU by brush. Cut a
strip of geotextile and tightly placing it along the junction. Apply second coat of PU over the geotextile in such a way that no air bubbles are left
in between. Fill all the cracks using PU- Liquid Applied polyurethane membrane. Slightly widen the crack using a cutting device and clean the
same using air blower to remove dust particles. Apply PU PRIMER in the crack and then after 1 hr inject PU into the crack. After 3-4 hrs check
for any absorbency if any fill the crack again till it gets filled. Providing and applying single component liquid applied polyurethane based
waterproofing membrane of PU to the entire area at the dose of 1.5 kgs per m2 Apply single coat of PRIMER with the help of brush and allow it
to dry for 2-3 hours. After primer has dried apply TWO coats of PU a single component moisture cured,polyurethane based elastomeric
membrane. Apply First coat of PU at 1 kg per m2 rate and allow it to cure for 24-48 hrs. Apply second coat PU at 0.5 kg per m2 rate. To provide
key for the screed, sand should be broadcasted while the second coat is still tacky. etc. complate As per drawings and design supplied by
architect and instruction given by authority and E.I.C. approved make: sunanda/ fosroc/ BASF/ pidilite
Providing and fixing 16 mm thick multiwall polycarbonate roofing sheets (Lexan / Bayer or equivalent approved make), UV resistant, light
transmission grade as specified, fixed over structural steel / aluminium framework, including supply and installation with approved self-drilling
Hilti screws with EPDM washers, providing 50 mm × 3 mm aluminium strips at joints and supports, application of approved silicone weather
201 R.A-71 105.00 sealant to ensure watertight sealing, proper alignment, edge finishing, provision for thermal expansion gap as per manufacturer’s specification, Sqm 1,620.92
cutting to required size, fixing ridge / side closures where required, protection film removal after installation, complete including all labour,
materials, scaffolding, T&P, lead and lift, wastage and incidentals, complete in all respects as per approved drawings, manufacturer’s
specifications and directions of Authority / Engineer-in-Charge.
Providing and fixing structural steel work welded in built-up sections and hollow sections, including columns, beams, joists, channels, M.S.
flats, angles, pipes, tees, plates and cleats, fabricated as per approved structural drawings, including cutting, bending, welding, drilling,
grinding, assembling, hoisting and fixing in position true to line and level, complete with all necessary connecting plates, angle cleats, gusset
202 R.A-72 59479.00 plates, bolts and welds, including surface preparation by wire brushing / cleaning to remove rust, scales and oil, applying one coat of approved Kg 111.16
zinc rich / red oxide primer and two coats of synthetic enamel / oil paint of approved shade, including all labour, materials, T&P, scaffolding,
lead and lift, wastage and incidentals, complete in all respects as per approved drawings, specifications and directions of Authority / Engineer-in-
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and fixing 600mm × 600mm or approved size aluminium metal tile ceiling system, comprising 0.7 mm thick aluminium clip-in plain
tiles with antimicrobial coating, factory finished, uniform in thickness and shade, with tile ends raised with pips and stops to ensure positive
engagement into spring system for secure locking and easy de-mounting of individual panels, tile sides sufficiently stiffened to ensure minimum
deflection across length, edges either bevelled or square as approved, powder coated with IAM series polyester based powder coating
formulated without TGIC, coating tested by independent laboratories conforming to internationally recognised standard JIS Z 2801:2000 for
203 R.A-73 10261.00 antimicrobial performance, tiles clipped into 0.5 mm thick G.I. clip-in rails, grid suspended from RCC slab using 4 mm diameter G.I. Sqm 2,097.67
suspension rods, hold-on clamps with clips and necessary accessories, including alignment, levelling, perimeter trim, edge profiles, cutting for
light fixtures, diffusers and services, providing expansion provisions as per manufacturer’s specification, complete with all labour, materials,
T&P, scaffolding, lead and lift, wastage and incidentals, finished true to line and level, complete in all respects as per approved drawings,
manufacturer’s specifications and directions of Authority / Engineer-in-Charge.
Make: Oculus® Building Products Pvt. Ltd. / Hunter Douglas India Pvt. Ltd. / Lindner Middle East or equivalent approved.
Providing and fixing gypsum board false ceiling system in approved design, comprising G.I. perimeter channel of 0.55 mm thickness having one
flange of 20 mm, another flange of 30 mm and web of 27 mm fixed along the perimeter of ceiling to brick work / concrete / partition using nylon
sleeves and screws at 610 mm centre to centre, suspending G.I. intermediate channels of 45 mm width, 0.9 mm thick, having two flanges of
mm each, from soffit at 1220 mm centre to centre using ceiling angles of size 25 mm × 10 mm × 0.5 mm thick fixed to soffit with G.I. cleats and
steel expansion fasteners, fixing ceiling sections of 0.55 mm thickness having knurled web of 51.5 mm and two flanges of 26 mm each with
10.5 mm lips, connected perpendicular to intermediate channels at 450 mm centre to centre using connecting clips, fixing 12.5 mm thick
204 R.A-74 121.00 tapered edge gypsum boards conforming to IS 2095 (Part I) to ceiling sections with 25 mm long drywall screws at 230 mm centre to centre Sqm 748.68
using mechanical drilling machine, finishing joints and tapered edges with jointing compound, paper tape and finishing compound to achieve
smooth flush surface, including forming drops, offsets, curves, mouldings, geometric patterns, providing cut-outs for light fixtures, speakers,
sprinklers, smoke detectors, trap doors, A.C. grills and diffusers, providing additional framing support around ducts and service openings
wherever required, marking grid lines, complete surface preparation including application of plaster putty, two coats of primer and minimum
three coats of plastic emulsion paint of approved shade, including scaffolding, labour, materials, T&P, lead and lift, wastage and incidentals,
complete in all respects as per approved drawings, specifications and directions of Authority / Engineer-in-Charge.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and fixing eco-friendly light weight calcium silicate false ceiling tiles having Tegular edge & 15mm Thick Densified edges on the
Tile Periphery for Extra Strength The Light weight calcium silicate ceiling tiles shall have, light reflection 85% non-combustible as per B.S.
part IV & also Non - Combustible / Zero Smoke Emmission as per UL -723, 100% humidity resistance and also having thermal conductivity
0.043° w/m KC. & also having Anti - Microbial Protection as Per JIS - Z2801 - 2010 for the best thermal Insulation. The Light weight calcium
Silicate tile shall be of approved texture Fine fissured/ Spintone/Cosmos/Spectra having NRC value of 0.5 & Globe having NRC value of
NRC or equivalent of size 595 X 595 mm to be laid on true horizontal level suspended inter locking metal grid of hot dipped galvanized steel
sections (galvanizing @120 grams per sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and
size of 24X38mm made from 0.30 mm thick (minimum) sheet, 1200mm centre to centre, and cross 'T' of size 24X28mm made out of 0.33mm
(Minimum) sheet spaced 1200mm along spaced between main T' at 600mm centre to centre to form a grid of 1200X600mm and secondary cross
"T' of length 600mm and size 24x28mm made of 0.30 mm thick (Minimum) sheet to be interlocked at middle of the 1200X600mm panel to
form grid of size 600X600mm resting on periphery walls/partitions on a perimeter wall angle pre-coated steel of size (24X24X3000mm made of
0.40mm thick (minimum) sheet with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and
laying 15mm thick Densified edges light weight calcium silicate ceiling tiles of approved texture (Fine Fissured/Cosmos/Spintone/Spectra) in
the grid including, cutting /making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required,
Main Trunners to be suspended from ceiling using G.I. slotted cleats of size 25X35X1.6mm fixed to ceiling with 12.5mm dia and 50mm long
dash fasteners, 4mm G.I. adjustable rods with galvanized steel level clips of size 85X30X0.8mm, spaced at 1200mm centre to centre long main
"T" bottom exposed with 24mm of all T-sections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings
and as directed by engineer- in-charge.Note:- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be
made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tiles shall have NRC. Value of
(Minimum) for Fine fissured/Spintone/Cosmos and 0.75 NRC for Globe, light reflection 85% non-combustible as per B.S. 476 part IV & also
Non - Combustible / Zero Smoke Emmission as per UL -723, 100% humidity resistance and also having thermal conductivity. 0.043° w/m KC.
& also having Anti - Microbial Protection as Per JIS - Z2801 - 2010 for the best thermal Insulation.
Providing plinth protection to building including excavation in ordinary soil to required depth and width, dressing and levelling the bed, laying
100 mm thick cement concrete (1:5:10) (1 cement : 5 coarse sand : 10 graded stone aggregate 20 mm nominal size) as foundation layer,
constructing brick masonry in cement mortar (1:6) to required height where specified, and providing 100 mm thick cement concrete (1:2:4) (1
206 R.A-75 443.00 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) as top coping, finished with 10 mm thick cement plaster, broom finish Sqm 1,354.25
on top surface, forming square line markings of 0.20 m × 0.20 m on top and sides as detailed, including proper slope away from building for
drainage, curing, finishing, cleaning, including all labour, materials, T&P, lead and lift, wastage and incidentals, complete in all respects as per
approved drawings, specifications and directions of Authority / Engineer-in-Charge.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and fixing 250 mm expansion joint system of Horizontal Internal : Floor to Floor FF , Floor to wall, Roof to wall: The work shall
consist supply and installation of joints and seals -expansion/seismic joint system 3R/Kantaflex model MSDSZJ/ MSD -QSZJ / MSDGCP/
MSWG/ MSW-QG/ MSDGCP/ MSD-QGCP in accordance with the drawings and requireements of the specifications below. The joints are
proprietary design utilizing extruded aluminum base members ,self aligning / centering arrangement and support plates.The material shall be
such that it provides wateright flat joint cover expansion control sysytem that is capable of accommodating multidirectional seismic movement
without stress to its components.System shall consisit of metal profile that incorporates a universal aluminum base member designed to
207 R.A-76 265.00 accommodate various project conditions and floor/roof treatments. including cover plate, The cover plate shall be designed of width and Rmt 8,595.10
thickness requried to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer's pre-
engineered self-centering arrangement that freely rotates / moves in all directions. The self - centering arrangement shall exhibit circular sphere
ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions
including vertical displacement ,Including EPDM Profile including cost of GP2 grouting. The joint sysytem shall resist damage or deterioration
from the impact of falling ice, exposure to UV,airborne contaminants as per manufacturer speciation and the joint design and drawing ,etc.,
complete all As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing 250 mm expansion joint system for Vertical joints :3R/Kantaflex of MSNG/ MSNSK/ MSN-QSK/ MSN-QG system
designed for internal/External wall and ceiling finishes with expansion movement of design for internal/EXTERNAL application on wall to
208 R.A-77 202.00 wall/ceiling /wall to corner including exposed metal plate /consealed metal plate /flush metal plate desired as per the joint design and design Rmt 7,201.30
width over the joint profile INCLUDING EPDM Profile including GP2 grouting as per the joint manufacturer speciation and the joint design
and drawing ,complete all As per drawings and design supplied by architect and instruction given by authority and E.I.C. (Vertical)
Providing and Fixing Rubber Corner Guard -800 x 100 x 100 MM x 6 MM BLACK WITH YELLOW REFLECTIVE SHEETING FIXED ON
209 R.A-78 168.00 THE WALL WITH SIX 2” SCREWS etc. complete As per drawings and design supplied by architect and instruction given by authority and Nos. 383.30
Providing and fixing ABS plastic modular speed bump units of size 750 mm × 250 mm × 75 mm, heavy duty, impact resistant, with anti-skid
line pattern top surface for enhanced tyre grip, in black and yellow combination, 4 Nos. per running metre (2 black + 2 yellow), filled internally
210 R.A-79 63.00 with cement concrete for added strength and stability, fixed firmly to finished road surface using suitable anchor bolts with sleeves, including Rmt 3,509.69
drilling, alignment, proper spacing, tightening, finishing, cleaning and all labour, materials, T&P, lead and lift, wastage and incidentals,
complete in all respects as per approved drawings, specifications and directions of Authority / Engineer-in-Charge.
SIGNAGES HANGING FROM CEILING - Providing, Fabricating & Fixing signage's using 304 grade Stainless steel 1.5 mm thick brushed
steel finish plate (2 nos) with 8mm thk. Acrylic sheet covered with vinyl of approved colour, sandwiched between two S.S plate and fixed with
s.s struds . Sandwiched plates should be fixed in 12mm X 12mm S.S 1.5mm thk.304 grade frame and punched (laser cut) lettering carried out
on both the s.s plates of required size and text as directed by Engineer and hanged to ceiling with the help of S.S 8mm thick chain at both ends
with making all the fixing arrangement to the ceiling and to the plate etc. complete all As per drawings and design supplied by architect and
instruction given by authority and E.I.C.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Supply & installation of Manual Roller blinds having Alluminium Roller tube along with fabric pasted on it with glue having control unit for
manual operations and bottom bar Aluminum powder coated for weight purpose, including fabric, fitting & accessories complete as directed by
EIC. Fabric to be approved by architect. etc. complete As per drawings and design supplied by architect and instruction given by authority and
Providing and fixing of Verticle Blinds fixed at all levels and sizes as per the manufacturers specifications . Fabric to be approved by architect.
Make : Vista or equivalent etc. complete All As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Supplying and Installing of Metalium SL-4 type 84R Aluminium 0.65mm TCT Plain Exterior Grade Powder Coating of Panels and Back side
214 R.A-83 735.00 Framming G.S. Black Exterior Louvre System. etc. complete All As per drawings and design supplied by architect and instruction given by Sqm 2,382.60
authority and E.I.C.
Supply & Installation external cladding using fibre cement plank of cassia/ straight grain/ teak coloured texture (External Grade) thickness 8mm
and dimension 150mmX3000mm. Fibre cement plank should be of minimum density 1300kg/ m3 (±50) and comply to ASTM C 1185 and ISO
8336 part (E) for confirming durability properties and BS 476 – part 5, 6 & 7, Thermal conductivity should be minimum 0.15 W/m˚K and PH
215 R.A-84 492.00 value should be in the range of 7 – 8. Depending on height of structure Board to be fixed using Aluminium rectangular frame section of suitable Sqm 1,598.83
gauge with minimum spacing 450mm to 600mm or As per drawings and design supplied by architect and instruction given by authority and
E.I.C., Plank to be fixed using Screws of Tensile strength 34N and Shear strength 68N on framing maintaining distance of minimum 25mm
between two planks . All plank to plank joints to be staggered and finished.
Providing & laying Tac tile 300mm x 300mmx 15mm flooring. The tile laid using with adhesive (Unive Make or Equivalent) as per site
216 R.A-85 675.00 condition including all labour and material, cleaning, curing, etc., complete all As per drawings and design supplied by architect and instruction Sqm 2,577.77
given by authority and E.I.C.
Providing & Laying polypropylene Flutted corrugated Floor Protector Sheets used for Floor Protection of Vitrified Tile etc. Complete. without
217 R.A-86 10263.00 damage of tiles including neat and clean of flooring & including loading, lifting,transporting, and disposal of debries outside of plot boundry et. Sqm 60.60
complete with all leads & lift. etc completed As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing & applying single part non shrink cementitious crack sealer for wider surface crack filler on existing concrete/ plaster surface. The
cracks to be sealed shall be saw cut or chiselled to/form a V groove at approx. of 6mm x 6mm, The grooves shall be cleaned to remove all the
loose particles, dust etc. The groove shall be sprinkled with clean water before applying sealing mortar- cementitious crack fillar shall be mixed
with water adopting w/c ratio and a mix proportion of 1 part of water to 3.0 part of filler mixer by volume or as per manufacturer's
218 R.A-87 105.00 specifications. Thorough mixing shall be carried out till a smooth, homogeneous paste is obtained. The mixed paste is fiiied into groove by Kg 203.78
gloved hand and the surface finished using a trowel. This continued till the full length of crack is sealed proper curing shall be done if groove
size exceed 6mm width or required otherwise as per site condition. The entire applications shall be done As per drawings and design supplied
by architect and instruction given by authority and E.I.C. (For payment purpose actual quantity of Non-shrink cementitious grout shall be
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and applying Bonding agent of bind old and new concrete after removing the cover of the old concrete and cleaning the
surface thoroughly. Application of the bonding agent shall be done as per manufacturer's specification and instructions and as directed. Rates to
be inclusive of scaffolding, staging etc. complete.
Note:-As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing & Fixing anchor fasteners including drilling in RCC / Masonary Members, fastening with structural steel members etc complete all
220 R.A-89 315.00 As per drawings and design supplied by architect and instruction given by authority and E.I.C.. Nos. 219.99
Providing & Fixing anchor fasteners including drilling in RCC / Masonary Members, fastening with structural steel members etc complete all
221 R.A-89 340.00 As per drawings and design supplied by architect and instruction given by authority and E.I.C.. Nos. 262.18
Providing & Fixing anchor fasteners . including drilling in RCC / Masonary Members, fastening with structural steel members etc complete all
222 R.A-89 365.00 As per drawings and design supplied by architect and instruction given by authority and E.I.C. Nos. 372.17
Providing & fixing of reinforcement bars ( reiforcement bars shall be paid extra under relevant item of work ) after drilling the hole of required
diameter & depth ,cleanning of the same ,providing /filling the hole with Injection Mortar inserting reinforcement bar etc. complete as per
Manufacturers & architects instruction.The work shall be carried out by the technical workmens/agency approved by the manufacturer and
under technical supervision of Manufacturer of Injection grout including all materials,tool tackles ,labour etc.complete all As per drawings and
design supplied by architect and instruction given by authority and E.I.C.
(a) 8 mm. dia.bar -Holes 12mm dia Depth 100mm
Providing & fixing of reinforcement bars ( reiforcement bars shall be paid extra under relevant item of work ) after drilling the hole of required
diameter & depth ,cleanning of the same ,providing /filling the hole with Injection Mortar (HY 150 or approved equivalant),inserting
reinforcement bar etc. complete as per Manufacturers & architects instruction.The work shall be carried out by the technical workmens/agency
approved by the manufacturer and under technical supervision of Manufacturer of Injection grout including all materials,tool tackles, labour
etc.complete As per drawings and design supplied by architect and instruction given by authority and E.I.C.
(B) 10 mm. dia.bar -Holes 14mm dia Depth 100mm
Providing & fixing of reinforcement bars ( reiforcement bars shall be paid extra under relevant item of work ) after drilling the hole of required
diameter & depth ,cleanning of the same ,providing /filling the hole with Injection Mortar (HY 150 or approved equivalant),inserting
reinforcement bar etc. complete as per Manufacturers & architects instruction.The work shall be carried out by the technical workmens/agency
approved by the manufacturer and under technical supervision of Manufacturer of Injection grout including all materials,tool tackles, labour
etc.complete As per drawings and design supplied by architect and instruction given by authority and E.I.C.
(C) 12 mm. dia.bar -Holes 16mm dia Depth 120mm
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing & fixing of reinforcement bars ( reiforcement bars shall be paid extra under relevant item of work ) after drilling the hole of required
diameter & depth ,cleanning of the same ,providing /filling the hole with Injection Mortar (HY 150 or approved equivalant),inserting
reinforcement bar etc. complete as per Manufacturers & architects instruction.The work shall be carried out by the technical workmens/agency
approved by the manufacturer and under technical supervision of Manufacturer of Injection grout including all materials,tool tackles, labour
etc.complete As per drawings and design supplied by architect and instruction given by authority and E.I.C.
(D) 16 mm. dia.bar -Holes 20mm dia Depth 160mm
Providing & fixing of reinforcement bars ( reiforcement bars shall be paid extra under relevant item of work ) after drilling the hole of required
diameter & depth ,cleanning of the same ,providing /filling the hole with Injection Mortar (HY 150 or approved equivalant),inserting
reinforcement bar etc. complete as per Manufacturers & architects instruction.The work shall be carried out by the technical workmens/agency
approved by the manufacturer and under technical supervision of Manufacturer of Injection grout including all materials,tool tackles, labour
etc.complete As per drawings and design supplied by architect and instruction given by authority and E.I.C.
(E) 20 mm. dia.bar -Holes 24mm dia Depth 200mm
228 R.A-91 310.00 Making holes upto 16mm dia. in masonry by hammer drilling machine including disposing the debries. Nos. 99.52
229 R.A-91 310.00 Making holes upto 22mm dia. in masonry by hammer drilling machine including disposing the debries. Nos. 100.71
230 R.A-91 310.00 Making holes upto 28mm dia. in masonry by hammer drilling machine including disposing the debries. Nos. 113.74
231 R.A-91 310.00 Making holes upto 40mm dia. in masonry by hammer drilling machine including disposing the debries. Nos. 155.20
232 R.A-91 310.00 Making holes upto 52mm dia. in any RCC members by diamond Core Cutting machine including disposing the debries. Nos. 319.88
233 R.A-91 310.00 Making holes upto 75mm dia. in any RCC members by diamond Core Cutting machine including disposing the debries. Nos. 355.42
234 R.A-91 310.00 Making holes upto 102mm dia. in any RCC members by diamond Core Cutting machine including disposing the debries. Nos. 426.50
235 R.A-91 310.00 Making holes upto 125mm dia. in any RCC members by diamond Core Cutting machine including disposing the debries. Nos. 497.59
236 R.A-91 310.00 Making holes upto 152mm dia. in any RCC members by diamond Core Cutting machine including disposing the debries. Nos. 568.67
237 R.A-91 310.00 Making holes upto 200mm dia. in any RCC members by diamond Core Cutting machine including disposing the debries. Nos. 853.01
238 R.A-91 310.00 Making holes upto 250mm dia. in any RCC members by diamond Core Cutting machine including disposing the debries. Nos. 995.17
239 R.A-91 310.00 Making holes upto 300mm dia. in any RCC members by diamond Core Cutting machine including disposing the debries. Nos. 1,492.76
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Avg 100 mm thick cement concrete flooring with concrete hardener topping, under layer 70 mm thick cement concrete 1:2:4 (1 cement :
coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener
240 R.A-92 210.00 mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per Sqm 938.29
manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete all As per drawings
and design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing rolling shutters of approved make made of 80 mm wide M.S. laths inter-locked together through their entire length and
jointed together at the ends by end locks mounted on specially designed pipe shaft with bracket plates, guide channels and arragements for
inside and outside locking with push-pull operation including the cost of hood cover and spring etc. complete.
(B) Shutters having width 3.5 M. and above
Carring out plinth treatment to post construction / existing structure by spraying chemical solution for termite control treatment including labour
Chapter 11 and material consistment with I.S.I specification. Using Chlordene and Chiorpurfiles 20 EC. As Per 6131_paret-II Consentration Weight one
242 22007 2798.00 percent is recommended i.e one litre 20 EC chemical emulsion with 19 liter give 1 % concrentration inclusive of one litre chemical emulsion Sqm 105.95
Page - 167 appication at the rate of 5 Litre chemical / Sqm of surface is recommended as per I.S. or As per drawings and design supplied by architect and
instruction given by authority and E.I.C.
Chapter 14 Providing and fixing pre-cast Rubber Dye inter locking concrete block 60mm thick with grade of concrete M300 pnumatic compressed by
243 14033 325.00 mechanically pressed and as per approved design including 75 mm sand layer for levelling and filling the joint with sand in proper line and level Sqm 686.90
Page - 130 etc. completed all As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Chapter 14 Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block 30cm length,30cm height and 15cm thick of M250 grade
244 14032 1270.00 concret as per approved design and including excavation for fixing in proper line and level,filling the joint with C:M 1:3 (1cement:3fine sand) Rmt 380.19
Page - 130 etc complete all As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and Laying Grassing with selection No.1 grass In rows 5 cm apart in both directions including watering and maintenance of the lawn
245 R.A-93 804.00 for 12 months or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying farm clay up 300 mm thick, Sqm 258.56
sludge, manure,pesticides , extra earth, disposal of rubbish, trench excavation and all labour with lead and lift etc. complete
Providing & construction Tree plants required Digging of pits 0.6mt. x 0.6mt x 0.6mt, filling with goodearth with mixing of cow dong and
pesticide.planting the following plant of 4' to 6' height stack it well, maintain it for 3 month name of plants Neem, Nagor, Avonla, Aritha,
Garmala, Neem, Nagor, Avonla, Aritha, Garmala, Neem, Nagor, Avonla, Aritha, Garmala, etc all As per drawings and design supplied by
architect and instruction given by authority and E.I.C.
Ayurvedic shrubbery Clinning the bed, mixing of the fertilizer and pesticides, digging the pit planting the good quality of plant at required
distance, maintain it for 12 month name of plants Tulsi, Brahmi, Aloe vera, Ardusi, Asparagus, Panputti, Nagar vel, Phudina, Ashwagandha,
Gugal, Wedellia, Jecomentia, Umbrella palm, etc
Note:- As per drawings and design supplied by architect and instruction given by authority and E.I.C.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Planting of exoitic palm trees Digging of pits 0.6mt. x 0.6mt x 0.6mt, filling with good earth with mixing of cow dong and pesticide.planting the
following plant of 8' to 10' height stack it well, maintain it for 12 month Bottle palm, Coconut, Sopari, Fish tail, Fox tail, Phonix, Date palm,
Bismarkia, Shampagon, Latania, etc
Note:- As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Planting of Ornamental shurbs Digging of pits 0.6mt. x 0.6mt x 0.6mt, filling with good earth with mixing of cow dong and pesticide.planting
the following plant of 8' to 10' height stack it well, maintain it for 12 month Golden bamboo, Green bamboo, Ficus spp.Ixora spp., Hibiscus
spp., Allamanda spp.Bougainvella spp., Nerium spp, Plumeria spp. etc.
Note:- As per drawings and design supplied by architect and instruction given by authority and E.I.C.
250 R.A-98 525.00 Providing pesticides ,dust As per drawings and design supplied by architect and instruction given by authority and E.I.C. Kg 80.81
251 R.A-99 105.00 Providing pesticides ,liquid As per drawings and design supplied by architect and instruction given by authority and E.I.C. Kg 600.95
Providing and fixing M.S. flat iron tree guard 60 cm dia and 2 m hight, above ground consisting 4 nos 25 x 6 mm, 2.25 m long and 8 nos 25 x
mm 2 m long verticals M.S. flats, riveted to 3 nos 25 x 6mm M.S. flat iron rings in two halves, fixing together at site withrequired six numbers
of 8 mm dia. and 30 mm long bolts, including painting two coats with synthetic enamel paint of approved brandand manufacture over a coat of
252 R.A-100 105.00 primer. One name plate of 1 mmthick M.S. sheet of size 250x100 mm shall be welded to the treeguard near the middle height and lettered PIU/ Nos. 2,912.93
any other approved name. The tree guard shall be suitably fixed to the groundby embedding four legs of tree guard in pits of suitable dia and to
adepth of 25 cm, refilling the pits with soil and ramming, complete inall respect As per drawings and design supplied by architect and
instruction given by authority and E.I.C.
Hording Erection of approved size (20' x 10') including 2" MS square pipe/ gurder ,1.5" pipe framing G.I sheet 26 or 28 gauge, Flex. as per the
253 R.A-101 2.00 Architect's instructions & approval. Each 42,975.50
Note:-As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and laying 40 mm thick artificial grass carpet made of UV-stabilized polyethylene / polypropylene monofilament yarn with minimum
pile height of 25 mm, natural dual-tone green color, having perforated latex / polyurethane backing for proper drainage, laid over prepared base
254 R.A-101A 35.00 surface including cleaning, leveling and laying with necessary jointing tapes and adhesives, fixing edges properly and brushing of fibers. The Sqm 712.37
work shall include supply of all materials, transportation, cutting, jointing, fixing, silica sand or rubber granule infill wherever required,
finishing and brushing complete as per manufacturer’s specification and as directed by the Engineer-in-Charge.
Providing and fixing bright finish 2 mm thick Stainless steel (Grade 304) 3D letters box size up to 900 cm height in English language with
Acrylic cut work and fixing 3mm acrylic on top of brand Ptglass,astari etc,with all laser and cnc work,including LED lighting illumination, all
material, labour and other hardwares, waste of materials etc fixed in wall at any height including scaffolding etc complete As per drawings and
design supplied by architect and instruction given by authority and E.I.C.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC
256 R.A-103 114.00 members and fixed to the reinforcement with binding wire before pouring concrete etc. complete all As per drawings and design supplied by Rmt 288.86
architect and instruction given by authority and E.I.C.) Serrated with central bulb (225 mm wide, 8-11 mm thick)
Providing & fixing CP brass double coat hook of premium quality etc. complete. As per drawings and design supplied by architect and
instruction given by authority and E.I.C.
Constructing RCC Under Ground water tank with Providing and laying controlled cement concrete M300 mix for R.C.C. work including
reinforcement, boxing, centering, vibrating, , PVC water stopper, curing and mixed with approved water proofing cement compound or
"CEMWET" or "PIDICRETE LW" integral water proofing admixture as water proofing agent to be mixed with 50 kgs. bags shall be as
recommended by the manufacture of the water proofing material, concrete work for top, bottom slab & side pardi for underground water tank
258 R.A-105 472500.00 item incl. Necessary excavation & refilling the available earth, 150 mm thick 1:2:4 for bedding of concrete, 20 mm thk. water proofing cement Liter 17.17
plaster in C.M. 1:3 with smooth finishing, Glazed Tile Flooring & Glazes Tile Dado in 1:3 (1 cement : 3 coarse sand) & 10 mm thick, vata,
watering etc. Comp. to all face of tank including locking arrangement outlet, inlet, overflow and washout outlet pipe arrangement as necessary
& C.I. Cover 0.60 x 0.45 weight not less then 35 kg with locking arrangement. etc. comp as per structural drawing Including Reinforcement
TMT-FE500D As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Constructing RCC Overhead water tank with Providing and laying controlled cement concrete M300 mix for R.C.C. work including
reinforcement, boxing, centering, vibrating, , PVC water stopper, curing and mixed with approved water proofing cement compound or
"CEMWET" or "PIDICRETE LW" integral water proofing admixture as water proofing agent to be mixed with 50 kgs. bags shall be as
recommended by the manufacture of the water proofing material, concrete work for top, bottom slab & side pardi for Overhead water tank item
incl. 20 mm thk. water proofing cement plaster in C.M. 1:3 with smooth finishing & Glazes tile Dedo, vata, watering etc. Comp. to all face of
tank . including locking arrangement outlet, inlet, overflow and washout outlet pipe arrangement as necessary & C.I. Cover 0.60 x 0.45 weight
not less then 35 kg with locking arrangement. etc. comp as per structural drawing Including Reinforcement TMT-FE500D As per drawings and
design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing High Pressure Laminate (HPL) compact grade cladding system including complete supporting framework, conforming to
IS 2046 and EN 438, manufactured under high pressure exceeding 5 MPa and temperature above 120°C, comprising layers of kraft paper
impregnated with thermosetting phenolic resin and decorative paper impregnated with thermosetting melamine resin, UV resistant, weather
resistant, moisture resistant, anti-graffiti and anti-bacterial, of approved shade, texture and minimum 6 mm thickness or as specified, fixed over
complete aluminium / hot dip galvanized steel sub-framing system comprising vertical and horizontal members, brackets, cleats, anchor
fasteners, spacer blocks and necessary accessories, mechanically anchored to RCC / masonry substrate with stainless steel fasteners, providing
required cavity gap for ventilation, maintaining expansion joints as per manufacturer’s specification, cutting, drilling, edge sealing, alignment,
plumb and level, sealing joints with approved weather grade sealant where required, including all hardware, scaffolding, labour, materials, T&P,
lead and lift, wastage and incidentals, complete in all respects as per approved drawings, manufacturer’s specifications and directions of
Architect / Engineer-in-Charge.
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and laying of Hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads and 250 gms per Sq.m. area
thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC-35 2015. The finished surface to be level/uniform and free from
streaks and holes or chipping of Thermoplastic if any and including primer coat for C.C. surface and A.C.C. surface, in white and/or yellow
261 R.A-108 543.00 colour. Rate includes brushing, blooming and cleaning and application of paint. Zebra patta/Bump patta/Lane line/Center line/Cut patta, Sqm 474.85
Directional Arrow, Lettering MoRT&H Clauses 803 &Volume II Part III and IRC 35-2015.Rate shall include brushing, brooming, painting and
repainting of worn out paint after a period of 2.5 years.
Note:-As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing G.I. chain link fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts
and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia
not less than 5 mm in required colour and shade Note:-As per drawings and design supplied by architect and instruction given by authority and
Providing and fixing flush door both sides laminated and I.T.W. beading all around by using I.T.W. frame 120 mm x 80mm shutter fabricated
from 35 mm thick solid core malemine faced three layered pre laminated flat pressed wood based exterior grade bonded BWP / BWR synthetic
263 R.A-110 262.00 resin having stamped IS 12823 grade I type II including three coats of lacquer polishing to exposed wooden surfaces and Stainless steel Sqm 5,228.13
decorative type designs fixtures / fastening 2 Nos. Handles, 2 Nos. Aldropes, tower bolt, door stopper etc. complete as per architectural
detailed drawing and as directed by engineer in charge. (Brand Name: Anjani / Shaktimat or Equivalent)
Extra for providing vision panel not exceeding 0.1 Sq.M. in all types of flush doors.
(A) Rectangular or Square.
Providing erecting and fixing three coated white Syntex/ Astral/ Supreme/RC Plasto PVC. (ISI) water tank of required capacity each with all
265 R.A-111 63000.00 necessary fittings and connection on terrace. etc. complete as per drawings and design supplied by architect and instruction given by authority Liter 13.94
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all
heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc.
The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and
embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size
300x230x300 mm, including cost of necessary centring and huttering and with approved expansion hold fasteners on CC/RCC surface,
266 R.A-112 12932.00 including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will Kg 144.99
be given a priming coat of Zinc primer as approved by Engineerin-charge and painted with two or more coats of epoxy paint (Shop drawings
shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal &
vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for
separately and nothing extra shall be paid).
Note:-As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and
washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary
recesses in stone slab, drilling required holes, etc. complete as per drawings and design supplied by architect and instruction given by authority
Providing and fixing dry cladding with sand stone 30 mm thick as per selection upto any height gang saw cut stone with (machine cut edges) of
uniform colour, fixed to structural steel frame work and / or with the help of cramps, pins etc. and sealing the joints with approved weather
sealant As per drawings and design supplied by architect and instruction given by authority and E.I.C. (The steel frame work, stainless steel
cramps and pins etc. shall be paid for separately.)
Providing and Fixing grc-glass reinforced concrete screen, beam, pillar in approved design, pattern, sizes and colour to be fixed on existing
structure of ms or rcc. the grc should be made from ‘53 grade’ cement , quartz, fine silica sand, alkali resistant glass fiber , super plasticizers
269 R.A-115 115.00 manufactured by ‘basf’ or equivalent, polymers and u.v resistant synthetic inorganic pigments should be used for pigmentation. the material Sqm 7,861.91
casting should take place in frp mould or equivalent. the fixing of grc should be ‘dry fixing’ as per the drawings approved by engineer in charge.
etc. complete as per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing Corten Steel (Weathering Steel conforming to ASTM A588 / equivalent grade) as per architectural elevation drawing
cladding/fins of minimum 3 mm thickness, laser cut and bent to required profile, fabricated in approved pattern, including MS/GI secondary
framing of required section, cleats, base plates, stiffeners, nuts, bolts, SS fasteners, anchor fasteners, welding, grinding and finishing, fixed to
270 R.A-115 1096.00 RCC/structural members as per approved structural design and architectural drawings and directions of Engineer-in-Charge, complete. Sqm 5,910.87
The item includes shop fabrication, transportation, erection, alignment, necessary edge stiffening, provision of expansion gaps, scaffolding, anti-
corrosion treatment (zinc rich primer and synthetic enamel paint) to all concealed MS members, and all incidental works required for proper
installation, Finish: Natural weathered Corten finish (self-protective oxide layer). Thickness: Minimum 3 mm.
271 R.A-116 211.00 Providing and fixing brass T patti as per required design for installation in wpc cladding or Tiles cladding as directed by EIC Rmt 479.75
SOR Item of Description Unit Rate Total Amount
SOR Item of Description Unit Rate Total Amount
Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain approved colour cladding , in
approved pattern and design for wall cladding, duct / shaft covering, partitions and façade applications, manufactured from virgin polymer of K
value 58–60 (suspension grade), calcium carbonate and natural fibres (wood powder / rice husk / wheat husk) with non-toxic additives
(maximum toxicity index 12 for 100 gms), having minimum density 650 kg/cum, minimum screw withdrawal strength 1800 N (face), minimum
272 R.A-117 197.00 compressive strength 50 N/mm², modulus of elasticity 850 N/mm², resistance to spread of flame Class A category, termite proof, borer proof, Sqm 3,471.52
water and moisture resistant and fire retardant properties, machine cut to required size, edges finished smooth, fixed over M.S. framework of
× 25 × 1.5 mm square hollow section grid at 1.0 m × 1.0 m or as required at site, including drilling, alignment, levelling, fixing with stainless
steel fasteners and SS screws, cutting and fitting at corners and junctions, complete in all respects as per approved drawings and directions of
Engineer-in-Charge.
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection >
and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement :
coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface
upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
Total Amount of Civil Work
Total Amount of Civil Work
Name of Work: CONSTRUCTION WORK OF GCRI HOSPITAL
SUB ESTIMATE FOR PLUMBING WORK
Item Item No. Total Rate with
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity LC 1%
A) SANITARY FIXTURES AND FITTINGS
Providing, Installation, testing & commissioning, in position European water closet
comprising of Wall hung European W.C. Pan in white colour, on approved type of chairs.
mm Concealed flush tank as directed.
C.P health faucet with required length of flexible tube, clamp and bracket for fixing to wall,
mm C.P. brass heavy quality angel stop cock for flushing health faucet
Fixing W.C. unit with chair brackets and accessories in position.
23010 23.112 European Wall Hung (rate changes possible as per market rate )
23011 23.113 Pan Connector
23013 23.115 Providing and fixing 12.5 Litres low level flushing cistern
23017 23.121 Seat Cover
798 M739 Health Fauset Heavy duty with hook with fitting
777 M718 C.P. Angle stop cock 15 mm Heavy duty with cap
Providing, Installation, testing & commissioning, in position White vitrious ching W.C.
sqatting pan Orrisa type
580 x 400 size in white colour, on approved type of chairs. 15 mm open flush tank as directed.
1.2 C.P health faucet with required length of flexible tube, clamp and bracket for fixing to wall, 15 Nos. 16.00 5,422.21 54.22
mm C.P. brass heavy quality angel stop cock for flushing health faucet
23009 23.111 Orissa Pan
23012 23.114 Foot rest
778 M719 C.P. Bib cock 15 mm Heavy duty with cap
Providing, Installation, testing & commissioning, Wash basin with tap hole on basin
comprising of Concealed type brackets fixed to wall with adjustable clamp to push against
counter rim. Concealed body parts for basin spout fixed to wall with basin Spout 32 mm
heavy plated C.P. waste coupling fitting with or without pop-up.
1.3 C.P. bottle trap with cleaning eye with extension piece and wall flange. Nos. 80.00 2,473.68 24.74
Painting brackets with two coats of white enamel paint over one coat of primer.
CP Wash Basin Pillar Cock 15 mm C.P. brass heavy grade flexible inlet connection.
15 mm C.P. brass heavy quality angle stop cocks
23020A 23.135 Waste Coupling
Item Item No. Total Rate with
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity LC 1%
Providing and fixing pillar tap, capstan head, screw down
high pressure with screws, shanks and back nuts. (i) 15mm dia.
777 M718 C.P. Angle stop cock 15 mm Heavy duty with cap
Providing and fixing chromium plated, bottle trap with
necessary couplings of approved quality for wash basin.
Providing, Installation, testing & commissioning, counter table Wash basin with sensor type
basin spout fixed on counter top with basin drain 32 mm heavy plated C.P. waste coupling
fitting with or without pop-up.
1.4 C.P. bottle trap with cleaning eye with extension piece and wall flange. Nos. 30.00 8,763.50 87.64
CP Wash Basin Pillar type sensor Cock 15 mm C.P. brass heavy grade flexible inlet
15 mm C.P. brass heavy quality angle stop cocks
MR-1 Basin - 550 x 400
23020A 23.135 Waste Coupling
Providing and fixing pillar type sensor cock with bottom flexible connection. (i) 15mm dia.
777 M718 C.P. Angle stop cock 15 mm Heavy duty with cap
Providing and fixing chromium plated, bottle trap with
necessary couplings of approved quality for wash basin.
Providing and fixing Urinal of approved quality including connection with trap and with
integral longitudinal flush pipe.(A) Squating plate pattern white earthenware 550mm
777 M718 C.P. Angle stop cock 15 mm Heavy duty with cap Nos. 18.00 403.39 4.03
MR -3 SS Pipe connection for Angle cock to Urianl for Water spray 300mm Nos. 18.00 300.00 3.00
Providing, Installation, testing & commissioning, S. S. sink, single bowl of size not more than
600 / 450 mm and depth 200 mm with tap point on wall / counter comprising of Concealed
type brackets fixed to wall with adjustable clamp to push against counter rim. 40 mm heavy
1.6 plated C.P. waste coupling fitting with or without pop-up. Nos. 2.00 2,806.15 28.06
40 mm heavy plated C.P. bottle trap with cleaning eye with extension piece and wall flange.
Painting brackets with two coats of white enamel paint over one coat of primer.
15 mm CP sink cock wall mounted.
23020B 23.135 Waste Coupling
778 M719 C.P. Bib cock 15 mm Heavy duty with cap
23034 23.12 Rubber plug for sink
Providing, Installation, testing & commissioning,screw down C.P. Water Bib cocks with wall
1.7 23028A 23.14 flange of heavy quality with all accessories, supplied by owners. Nos. 100.00 212.68 2.13
Item Item No. Total Rate with
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity LC 1%
Providing, Installation, testing & commissioning,screw down C.P. Angle cocks with wall
flange of heavy quality with all accessories, supplied by owners. For Geyser, RO, & Washing
Providing, Installation, testing & commissioning, CP brass / S.S. towel rail, 600 mm. long
1.9 23025 23.144 and 20 mm. dia., with concealed type brackets fixed, to the wall with CP brass screws, etc. Nos. 48.00 610.32 6.10
Installation, testing & commissioning, screw-to-wall type toilet paper-roll holder, fixed to the
wall with CP brass screws, etc. complete.
1.11 23023 23.141 Providing and fixing C.P. brass shower with 15mm inlet.(A) 100mm dia. Nos. 5.00 279.37 2.79
Providing and fixing C.P. brass Wall mounted Mixer with Spout & OH shower pipe
connection with necessary parts complete job.
Providing and fixing C.P. brass foot operated shower system, OH shower pipe connection with
necessary parts complete job.
B) WATER SUPPLY
Providing and fixing, in proper line and level (with necessary support like, brick masonry
pedestals and battens, if necessary) to floor, approved quality, heavy duty, White UPVC-
Schedule 40 Grade as per ASTM D-1785, of Astral or equivalent, Open & Conceal piping,
complete, including jointing with rubbering and airtight joints, with necessary specials,
couplers, elbow, equal tees, tail piece, adapter (both male and female), reducer (single stage,
double stage and triple stage), end cap, fabricated bend, etc., and lubricant or jointing material,
including testing, cutting, making good the wall, ceiling and floor etc. Testing & installation of
pipe lines as per drawing & specification.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE
having National Sanitation Foundation (NSF) seal for potable water of
following dia. nominal bore tube fittings and clamps including making good the wall, ceiling
and floor etc. complete. All Conceal Pipe line Cold & Hot Water
Item Item No. Total Rate with
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity LC 1%
2.3 MR-9 Providing & installaing Rubber Insulation 9mm thik for Conceal Hot water pipe line
Providing, fixing, jointing and testing, heavy quality cast bronze / brass BALL VALVE / OR
WHEEL valves of approved make, including flanges / unions, nuts, bolts, washers, etc.
complete, as approved by the Architect and Engineer-in-charge for water supply lines of the
following Nominal bore (NB) size:
Providing, fixing, jointing and testing, heavy Quality Gun metal or brass Non return valve
2.4 confirming to IS 778, with screwed / flanged ends, 20 Kg/m2 of approved make, on water
supply lines of the following Nominal bore (NB) size:
C) INTERNAL DRAINAGE
Providing and fixing Approved SWR Type B quality, heavy duty, UPVC pipes - Ring Fit &
Self Fit, Supreme or equivalent make, Confirming to IS 13592 & Fitting confirming to IS
14735 for waste water or soil waste pipe, with necessary specials, bends, such as `Y' junction,
`T' junction (both single and double), including plugs, shoes, cowls, flange compression type
3.1 fittings, wall clips, in proper line and level with necessary support like brackets/clamps, clips,
RCC or brick pedestals or battens, if necessary, to wall, ceiling and floor, open or concealed
complete jointing with rubberising and airtight joints, with ‘T’ shaped rubber ring, etc., and
lubricant or jointing material, including testing, cutting, making good the wall, ceiling and
floor, etc. Testing & installation of pipe lines as per drawing & specification.
3.1.1 23066 160 mm. (Soil + Waste + Rain Water) - Type B rmt 750.00 826.12 8.26
3.1.2 23067 110 mm. (Soil + Waste + Rain Water) - Type B rmt 780.00 847.55 8.48
Item Item No. Total Rate with
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity LC 1%
3.1.3 23004F 23.80 75 mm. - Balcony + Standing Balcony + AC Drain - PVC 10 KG rmt 80.00 277.46 2.77
3.1.4 23004D 23.80 40 mm for waste water for Sink - PVC 10 KG rmt 26.00 126.10 1.26
3.1.5 23004C 23.80 32 mm for waste water for Wash basin - PVC 10 KG rmt 178.00 120.76 1.21
Providing, fixing, jointing and testing IS 14735 for Drain PVC SWR 'P' - traps of self
cleansing design with water seal not less than 50 mm., with or without vent, cutting chases /
3.2 MR-12 hole in floors / slabs and bringing the same in proper condition and shape after placing the
trap in right position in case of suspended / open plumbing or setting the trap in 1:2:4 CC in
case of concealed plumbing , etc. complete, as required. The trap shall be 'P' type, of
following sizes:
3.2.1 110 x 110 mm OD inlet / outlet no 90.00 600.00 6.00
Providing, fixing, jointing and testing IS 14735 for Drain PVC Multi Floor Trap 7'' HT of self
cleansing design with water seal not less than 50 mm., with or without vent, cutting chases /
3.3 MR-13 hole in floors / slabs and bringing the same in proper condition and shape after placing the 2.00 375.00 3.75
trap in right position in case of suspended / open plumbing or setting the trap in 1:2:4 CC in
case of concealed plumbing , etc. complete, as required. no
Providing and fixing Heavy class S.S. grating with Mosquito proof S.S. strainer of Chilly
3.4 MR-14 or equivalent make, as approved, (cockroach trap) including setting in floor with cement no 92.00 750.00 7.50
mortor to match with floor finish as per architect requirements.
Providing and fixing, PVC cowl, on PVC ventilating pipes and verticals for soil, waste and
3.5 894 M835 rain water Pipes at top level / terrace level, as specified and required, etc. complete. 75 OD no 4.00 9.32 0.09
Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 mm diameter with jali of
3.6 23068 the following nominal diameter of self cleansing design with C.I scread down or hinged 10.00 579.57 5.80
grating including the cost of cutting and making good the walls. (for Balcony) no
D) EXTERNAL DRAINAGE
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure
pipes I.S., class NP2 of the following internal diameter with collars
and butt ends prepared for collar joints including testing, of joints complete.(B) 150mm
Item Item No. Total Rate with
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity LC 1%
Providing, fixing, jointing and testing salt glazed stoneware Gully trap, class `A', including
excavation in all soil types, bailing or pumping out water from trenches, shoring whenever
necessary testing,refilling, in layers ramming & consolidation, removing away the surplus earth
& spoils, dumping it on site or carting away to lead of 100 meters as directed, incl. embedding
4.2 the trap in CC 1:2:4, construction of brick masonry chamber, internal clear size 300 mm. x 300 no 40.00 1,234.57 12.35
mm., in brick work 230 mm. thick, in CM 1:4, plastering inside, outside and all exposed
surfaces with CM 1:3, 12 mm. thick, with 300 x 300mm Gully trap chamber & providing,
fixing CI frame and cover 300 x 300 mm., weighing together not less than 12.5 Kg., painting
of all CI items with 3 coats of approved bitumastic paint, etc. Complete.of the following
Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water tight
4.2.1 24006B 24.19 C.I. cover with frame of 300mm x 300mm size (inside) with standard weight.(i) Square mouth 1,234.57 12.35
traps.(B) 150mm x 100mm size P or R type
Constructing Inspection chamber 450 x450 x 600 mm clear size in 230 mm thick brick
masonry with cement mortar (1:5) as per ISI with 150 mm thick 1:3:6 P.C.C. bedding,
necessary benching in concrete (M-15) and 20 mm thick smooth cement plaster (1:4) from
4.3 24014 24.41 inside, C.I. steps as necessary and rough cement plaster 20 mm thick in c.m. 1:4 outside, with no 3.00 2,520.65 25.21
50 kg. Full size C.I. manhole cover and frame (Approved Make) including all excavation in all
soil types, refilling sides in layers with selected earth ramming and consolidating, removing
away surplus soil or dumping it on site as directed (Depth upto 1500 mm to invert).
Extra over and above item no. beyond 1.5 m. depth, for every additional depth of 0.1 m. or
part thereof, for brick masonry Inspection chamber.
Item Item No. Total Rate with
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity LC 1%
Constructing brick masonry chamber for underground C.I. Inspection chamber and bends with
bricks having crushing strength not less than 35Kg/ Cm2 in C.M. 1:5
C.I. cover with frame (Light duty) 455mm x 610mm intenal dimensions total weight of cover
with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of
4.4 24016CA 24.44 frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone no 20.00 7,109.35 71.09
aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15mm thick with cement
mortar 1:3 finished smooth with a floating coat of neat cement on walls and bed concrete etc.
complete.(iii) Inside dimensions 600mm x 850 mm and 450mm deep for pipe lines with three
or more inlets.
Extra over and above item no. beyond 1.5 m. depth, for every additional depth of 0.1 m. or
part thereof, for brick masonry Inspection chamber.
Providing and fixing CI Cover manhole frame and cover 455 x 610, light / medium / heavy
weight,Circular / rectangular tested as per IS:1726 for load bearing.The cover is to be provided
with a 5mm thick high abrasion surface.The cover is to be of double seal type with SS 316 no
Socket type key hole lifting / Rod lifting arrangement . The lifting arrangement is to be closed
from the bottom side. etc. complete as directed by E-I-C.
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded
stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix
(1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with
Cement Mortar 1:3 (1-Cement : 3-coarse sand) finished with a floating coat
of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand
4.6 24008A 24.27 :4-stone aggregate 20mm nominal size) finished smooth complete including no 20.00 10,933.41 109.33
curing and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with
frame size 560mm diameter total weight of cover and frame to be not less
than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of
brick msonry using brick having crushing strength not less than 35Kg. /
Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand)(1) A type depth 0.90 Metre for
150mm diameter sewer.
(I) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. or Part thereof
over item No.24.27 (I) for depth from 0.9M to 1.5M.
Item Item No. Total Rate with
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity LC 1%
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded
stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand
:6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:3 (1-
Cement : 3-coarse sand) finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 mix (1-Cement :2- Coarse sand :4-stone aggregate
24008B 24.27 20mm nominal size) finished smooth complete including curing and festing (i) Inside size no 2.00 19,158.00 191.58
900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total
weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame
64 Kg.)(A) With 230mm thick walls of brick msonry
using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1-
Cement: 5-Coarse sand) (2)B type depth 1.50 Metre for 150mm diameter sewer.
(II) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. GR Part
thereof over item No.24.27 (I) for depth from 1.50M. to 2.25M.
E) UTILITY ITEMS
Installing, testing and commissioing of Pump system comprising of horizontal Submersible
Pumps with SS casing, SS impeller, SS Shaft and driven by 415 V AC, 3 phase, 50HZ., motor
running at 2900 rpm speed and shall be supplied with all accessories viz., base plate, coupling,
motor, VFD based control panel, dry run & overload protection, cabling up to panel, earthing,
GI medium duty suction, delivery & header pipes, pressure gauge, pressure switches, pressure
transmitter, suction ball valves & delivery ball valves & check valves etc., complete.
5.1.1 MR-16 200 lpm., 50mtr., (To GF TO TERRACE TANK) FOR DOMESTIC WATER SET 1.00 50,000.00 500.00
Supply, installation, testing & commissioning of Water level controller for the OH tanks with
switches, hardwares, interlocking with panel, etc.
For Under Ground tank & OH Tank SET 1.00 10,000.00 100.00
5.3 MR-18 Drinking Water Cooller Unit 20 Liter to 30 Liter SET 6.00 40,000.00 400.00
Providing, Supply & Installation of RO System 2000 Liter per Hour with SS material Pump
with SS pipe line & fittings use in Plant. FOR Drinking Water
5.5 MR-20 Providing, Supply & Installation of SS 316 Storage tank with SS Stand 1000 Liter no 5.00 2,00,000.00 2000.00
Supply, install, test and commission electric storage-type water heater (geyser) of approved
make and capacity 10 litres, complete with thermostat, heating element, inner tank with
corrosion-resistant lining, thermal insulation, outer casing, temperature and pressure relief
5.6 MR-21 valve, non-return valve, isolation valve, drain valve, wall/floor mounting brackets, electrical no 2.00 10,000.00 100.00
connections, safety controls, and all necessary fittings and accessories, in accordance with
manufacturer’s specifications and relevant standards.
Item Item No. Total Rate with
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity LC 1%
Providing, Installing, testing and commissioing of Hot Water Sysytem 3000 Ltr With Storage
5.7 MR-22 Tank , Compressor, Electric control panel system with all standard parts with all necessary SET 2.00 10,00,000.00 10000.00
parts & fittings, Testing & Installation as per Drawing & specifications.
Providing, Supply & Installation of Hot Water Sysytem 1.5 hp with hot temperatuure level
Proposed New Construction Of Cyclotron & Nuclear Medicine Building For GCRI at Asarwa, Ahmedabad.
BOQ - Fire Fighting Work
Sr.No. Item Description Unit Rate
Quantity Amount
A Fire Pump Room Acce. (Positive Suction).
Supplying, Installation, Testing and commissioning of electric driven main fire pump suitable for automatic operation
and consisting of following: Horizontal type, centrifugal End Suction pump of cast iron body & bronze impeller
mechanical seal to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of
137m3/Hour@80M. head conforming to IS 1520. The pump shall be coupled to TEFC motor of suitable HP & speed
and complete set shall mounted on common base frame with, coupling, coupling guard, foundation bolts etc. as
required. (Hydrant & Sprinkler System)
Supplying, Installation, Testing and commissioning of Diesel Engine driven fire pump suitable for automatic
operation and consisting of following: Horizontal type, centrifugal End Suction pump of cast iron body & bronze
impeller , mechanical seal to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified
flow of 137m3/Hour@80M head conforming to IS 1520.The pump shall be coupled to TEFC motor of suitable HP
& speed and complete set shall mounted on common base frame with , coupling, coupling guard, foundation bolts etc.
Supplying, Installation, Testing and commissioning of Jockey Pump 10.8M3/[email protected] Centrifugal End
Suction. he pump shall be coupled to TEFC motor of suitable HP & speed and complete set shall mounted on
common base frame with coupling, coupling guard, foundation bolts etc. as required. (Hydrant & Sprinkler
Supplying, Installation, Testing and commissioning of cubical type floor mounted power cum control panel
4.0 complete with suitable switch gear, bus bars, relays, contractors, indicating lamps, fuses, instruments manual isolator 1.00 No. 257550.00
& auxillary switch including connections complete as required.
Providing, fixing, testing and commissioning below Cable for Fire Pumps
(Only from Panel to Pumps)
5.01 3 C X 35 Sqmm Alluminium Armoured 60.00 Mtr 421.17
5.02 3 C X 16 Sqmm Alluminium Armoured 60.00 Mtr 254.52
5.03 2 C X 1.5 Sqmm Copper Armoured. 150.00 Mtr 144.43
5.04 Cable Tray 300X50 mm. 20.00 Mtr 742.35
5.05 Cable Tray 150X50 mm. 20.00 Mtr 515.10
Providing, fixing, testing and commissioning of Pressure Gauge with cock & accessories for pumps.The pressure
6.0 gauge shall be approved type. The Gauges with cock shall be constructed of die cast aluminium & stove enameled. 7.00 Nos. 4090.50
The Gauge shall be of stainless steel bourden type.
Providing, fixing, testing and commissioning of Pressure switches of diaphram operated SPDT type whether IP66
suitable range (15 kg/cm² to 5 kg/cm²) for pump sets with Ball valves, Fittings like unions / collars / reducers etc.
Sr.No. Item Description Unit Rate
Quantity Amount
Providing, fixing, testing and commissioning Air vessel fabricated from 10mm Room
Fire Pump MS plate with(Positive
Acce. dished ends,dia of
mm and height 1500 mm with suitable supporting legs, outside painted with one coat of primer and two coats of
8.0 synthetic enamel paint of approved shade, complete with one 25mm dia connection from pump delivery, one 25 mm 2.00 No. 48480.00
drain with valve.The air vessel shall be tested to 1.5 times of working pressure. Complete as per technical
specification & drawing details.
Providing, fixing, testing & commissioning of C.I.Butterfly valve conforming to IS:13095 class PN 16 rating with
Fittings, Flanges, Nutbolts, Washers, Gaskets etc.of size:
9.06 25mm dia.Ball Valve. 4.00 Nos. 1441.27
9.07 15mm dia Ball Valve. 12.00 Nos. 756.49
Providing, fixing, testing and commissioning of C.I. Dual plate type Non-Return Valve class PN 16 rating with
fittings, flanges, nutbolts, washers, gaskets etc.of sizes:
Providing, fixing, testing and commissioning of Above Ground MS. ERW Black C Class Heavyduty pipes as per
IS: 1239 (upto 150 mm dia.) and IS: 3589 (upto 200 mm dia. And above) including cutting, screwing, welding etc.
and providing all fittings like flanges, bends, tees, elbows, reducers, clamps, hangers etc. with painting of one coat of
primer and 2 or more coats of synthetic enamel paint of approved make / shade complete as per specification.
12.0 Providing and fixing, testing and commissioning of "Y" Type Strainer
Sr.No. Item Description Unit Rate
Quantity Amount
B Fire Pump Room Acce.
Fire Hydrant (Positive
System Suction).
Providing, fixing, testing and commissioning of Above Ground MS. ERW Black C Class Heavyduty pipes as per
IS: 1239 (upto 150 mm dia.) and IS: 3589 (upto 200 mm dia. And above) including cutting, screwing, welding etc.
and providing all fittings like flanges, bends, tees, elbows, reducers, clamps, hangers etc. with painting of one coat of
primer and 2 or more coats of synthetic enamel paint of approved make / shade complete as per specification.
Providing, fixing, testing and commissioning of Under Ground M.S. ERW Black C Class Heavyduty pipes as per
14.0 IS: 1239 (upto 150 mm dia.) and IS: 3589 (upto 200 mm dia. And above) with IWL/pypecoat, 4mm thickness
wrapping and coating and providing all fittings like flanges, tees, elbow, fasteners with all required.
Providing, fixing, testing & commissioning of C.I.Butterfly valve conforming to I.S:13095 class PN 16 rating with
Fittings, Flanges, Nutbolts, Washers, Gaskets etc.of size:
Providing, fixing, testing and commissioning of C.I. Dual plate type Non-Return Valve class PN 16 rating with
fittings, flanges, nutbolts, washers, gaskets etc.of sizes:
17.0 Fire Fighting Equipement
Providing, fixing, testing and commissioning of SS Single Headed Oblique Pattern Hydrant Landing Valves as
per IS: 5290 with 80 mm dia flanged inlet & 63 mm dia female outlet complete with cap and chain etc.
Providing, fixing, testing and commissioning of SS Branch Pipe with nozzle of 20 mm nominal bore outlet suitable
to fit with standard instanteneous type 63 mm dia coupling. As per IS:903.
Providing, fixing, testing and commissioning of 63 mm dia 15m long RRL Hose Pipe with 63 mm dia.Type A Male
and female Stainless Steel couplings duly binded with GI wire, rivets etc. conforming to IS 636 as required.
Sr.No. Item Description Unit Rate
Quantity Amount
Providing, fixing, testing and commissioning of weather proof standard fire Hose
Fire Pump RoomCabinet wall mounting
Acce. (Positive type
17.04 Guage. (750 x 600 x 250) having Double Opening with M.S. fabricated stand, necessary locking arrangement by 31.00 Nos. 6969.00
Providing, fixing, testing and commissioning of Wall mounting swing type first aid Fire Hose Reel with drum,
17.05 hanging bracket, 36 M x 25 mm dia high pressure hose reel tubing as per IS:884 with shut nozzle and ball valve and 24.00 Nos. 8961.73
all required accessories.
Providing, fixing, testing and commissioning of 25 mm dia Air Release Valve and Ball Valve assembly on top of
each riser for Air release system.
Providing, fixing, testing and commissioning of CI Four way Fire Brigade Inlet as per IS: 904 having 63 mm dia
inlet with 150 mm dia Butterfly valve blank cap and chain with necessary fittings, flanges, nutbolts etc.
Providing, fixing, testing and commissioning of CI Two way Fire Brigade Inlet as per IS: 904 having 63 mm dia
17.08 inlet with blank cap and chain with 100 mm dia Butterfly valve necessary fittings, flanges, nutbolts, gasket and all 1.00 Nos. 10826.19
required accessories.
C Automatic Fire Sprinkler System.
Providing, fixing, testing and commissioning of Above Ground MS. ERW Black C Class Heavyduty pipes as per
IS: 1239 (upto 150 mm dia.) and IS: 3589 (upto 200 mm dia. And above) including cutting, screwing, welding etc.
and providing all fittings like flanges, bends, tees, elbows, reducers, clamps, hangers etc. with painting of one coat of
primer and 2 or more coats of synthetic enamel paint of approved make / shade complete as per specification.
Providing, fixing, testing and commissioning of Under Ground M.S. ERW Black C Class Heavyduty pipes as per
19.0 IS: 1239 (upto 150 mm dia.) and IS: 3589 (upto 200 mm dia. And above) with IWL/pypecoat, 4mm thickness
wrapping and coating and providing all fittings like flanges, tees, elbow, fasteners with all required.
Providing, fixing, testing & commissioning of C.I.Butterfly valve conforming to IS:13095 class PN 16 rating with
Fittings, Flanges, Nutbolts, Washers, Gaskets etc.of size:
Sr.No. Item Description Unit Rate
Quantity Amount
20.03 80mm dia. Fire Pump Room Acce. (Positive Suction). 0.00 Nos. 5471.17
D Sprinkler System Equipements.
Providing, fixing, testing and commissioning of Sprinkler Alarm valve of cast iron body and brass/bronze working
parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong
21.0 bell to sound continuous alarm when the sprinkler system activates, pressure guages, emergancy releases, strainer, 1.00 No. 68553.75
pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, flanges, gasket etc.
of size 150 mm dia.
Providing and fixing, testing and commissioning of K 5.6 Pendent type Standard response Sprinkler rating of
deg.C. with required accessories.
Providing, fixing, testing and commissioning K 5.6 Upright Sprinkler Standard response rating of 68 deg.C . with
required accessories.
Providing and fixing, testing and commissioning of K 5.6 Side Wall type Standard response Sprinkler rating of
deg.C. with required accessories.
Providing and fixing, testing and commissioning of K 5.6 Pendent type Standard response Sprinkler rating of
deg.C. with required accessories.
Providing, fixing, testing and commissioning of SS Flexible drops 1200mm Long.Unbraided , Maximumm Service
26.0 pressure 175PSI,.Sprinkler Flexible Drop system is a ready to use assembly to fit sprinkler heads in desired location 1042.00 Nos. 1066.56
in a suspended ceiling. It easily positions the sprinkler in center of the ceiling tile at a correct height.
Providing, fixing, testing and commissioning of Flow Indicating Switch with fittings, Flanges, nut-bolts, washers
etc. as per requirement of sizes. 150MM .
Providing, fixing, testing and commissioning of Annunciator panel for flow control switch, providing
Audio/Visual indicating of actuation of automatic sprinkler system for each zone complete as per specifications with
provision for 12 zones 'Indication of zone fire, 'Indication of zone fault, 'Fire/Fault hooter, 'Alarm cancel for
fire/fault, 'Battery for emergency
Sr.No. Item Description Unit Rate
Quantity Amount
Supplying, Installation, Testing and commissioning of 2 C X 1.5 PumpCopper
Sqmm Room Acce. (Positive
Armoured forSuction).
Cabling from Announciation panel to Flow Switch.
Providing and fixing, testing and commissioning of Drainning & Testing Assembly 25mm dia with by pass valve,
drain connection & Sight Glass as required.
E Fire Extinguishers
Providing & fixing of ABC 6 Kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type,
Pressure Gauge, Controllable discharge mechanism Class A Rating 3A & Class B rating 21B as per IS
Providing and fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 4.5 kg filled with Co2
32.0 Gas as per IS 15222 with controll discharge mechanis, fitted with Hose & Horn applicable on Class B fire rating 21B 59.00 Nos. 5322.70
confirms to IS 15683 bearing ISI mark. Co2 cylinder as per IS 7285 .
Providing and fixing, testing and commissioning of Higher capacity Trolley mounted ABC Dry Chemical; Powder
33.0 type ( MAP - 90% ) Fire Extinguisher of capacity 25 kg. confirms to IS 10658, bearing ISI mark, ( Outside Co2 3.00 Nos. 8358.76
Cylinder 1 Kgs. Cap )
Providing and fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 22.5 kg filled with Co2
34.0 Gas as per IS 15222 with controll discharge mechanism fitted with Hose, Horn & TROLLEY confirms to IS 2878 3.00 Nos. 19240.50
bearing ISI mark. Co2 Cylinder as per IS 7285 .
Providing and fixing, testing and commissioning of Higher capacity Trolley mounted Mechanical Foam type Fire
Extinguisher of Capacity 50 liter confirms to IS 13386, bearing ISI mark, (Quoted For 45 ltr)
36.0 Providing, fixing, testing and commissioning of below Auto Glow Signages.
36.02 Fire Hydrant 4" X 12" 24.00 Nos. 442.38
36.04 In Case of Fire do not use Lift ,Use Staircase 8"x 8" 12.00 Nos. 539.34
36.05 Fire Extinguisher 8"x 8" 59.00 Nos. 539.34
36.06 Fire Pump Room 12"X 6" 1.00 Nos. 587.82
Providing, printing, supplying, and fixing of autoglow (photoluminescent) Emergency Escape Plan signage of size A3
(297 mm × 420 mm), complete in all respects & capable of glowing in darkness without external power; the signage
shall be UV/eco-solvent printed with clear floor layout showing escape routes, exits, “You Are Here” location, fire-
fighting equipment and assembly points with standard symbols and bilingual text as required.
Sr.No. Item Description Unit Rate
Quantity Amount
Providing, supplying, and fixing of photoluminescent (autoglow) routeFiremarker
in roll (Positive
form of sizeSuction).
× 10 m length, complete in all respects & capable of emitting visible glow in darkness after exposure to ambient light,
36.08 suitable for marking escape routes, corridors, and stair paths; the tape shall be applied on clean, dry surfaces with 238.00 Nos. 2464.40
proper alignment and firm adhesion, including surface preparation, cutting, laying, and all materials, labour, tools,
and incidental charges complete as per specifications and directions of Engineer-in-Charge.
37.0 Civil Work. (In Client Scope)
37.01 Providing, fixing, testing and commissioning Hume Pipe NP2 class 400mm dia. 30.00 Meter 1433.19
37.02 valve camber. 1M X 1M X 1M. 4.00 Nos. 106050.00
37.03 Excavation & Backfilling Of Soft And Hard soil. 280.00 Cu.Mtr 757.50
38.0 Supply, Installaton of Structure Steel Support 2250.00 KG 125.24
APPROVAL FIRE SYSTEM FROM LOCAL FIRE AUTHORITY
39.0 Getting of Fire Fighting System Approval from local fire authority with all other charges and documentations for 1.00 Job. 252500.00
getting No Objection Certificate (NOC, FSPA/Opinion).
Fire Rated Steel Doors with Steel Frames as per BS:476 (20&22), IS 3614 (Part-2) for stability and integrity.
pressed Galvanized steel conforming to IS 277 with the following specification. recommended fire door shell have
doors tested at CBRI for maximum rating of 120 Minutes.
Door frame shall be Single rebate profile of size 105 x 57 mm made out of 1.60mm (16gauge) minimum thick
galvanized steel sheet. Frames shall be mitered and field assembled with self-tabs. All provision should be mortised,
drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the striking jamb.
Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered
masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for fire doors on
the clear masonry opening.
40.0 Door leaf shall be 46mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) 139.00 Sqmtr 33330.00
minimum thick galvanized steel sheet. The internal construction of the door should be rigid reinforcement pads for
receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory
prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door
closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be
provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as
per manufacturer's recommendation with a beading and screws from inside. The glass should be 6mm clear
borosilicate fire rated glass of relevant rating of the door.
All doors and frames shall be finished with polyurethane aliphatic grade paint of approved color. The door leaf and
frame shall have passed minimum 250 hours of salt spray test. Rate should include supply and installation of door
and hardware set as mentioned in the door. Hardware Fittings Make :- Doorma , Geze , Hafales
Sr.No. Item Description Unit Rate
Quantity Amount
Non Comprehensive Quarterly Maintenance service charge for Fire Fire Pump
Fighting System
Acce. servicing
(Positive of fire
fighting system with cleaning ,oiling and Greasing of fire fighting equipment's, give live demonstrations And
performing live mock drill once in a year of the system after completion of DLP.
Quarterly servicing and maintenance will be done for Fire Fighting systems.
a) To check & Maintain the Fire Fighting System as per Installation done.
b) Checking of Butterfly valve , NRV, Ball valve for smooth operation.
c) Checking of Fire Brigade Inlet.
41.0 d) Visually check of Sprinklers for Leakage.
e) Fire Extinguisher to be checked physically.
f) Testing of Main Pump, Sprinkler Pump & Jockey Pump, Fire Panel.
g) Physical checking of each Fire fighting Equipment's. (Like Hydrant Valve , Hose Reel,Hose Box , Hose pipe And
Branch Pipe etc..)
h) Checking of Pump room in active working condition.
I) Refilling of Fire Extinguisher will be in contractor scope as per client requirements.
J) Including Charges for fire New / Renewal NOC, for Fire Fighting System.
K) Videography , Photo graphy , numburing & Pendrive etc. as per norms for New / Renewal NOC.
41.01 First Year 1.00 Job. 353421.90
41.02 Second Year 1.00 Job. 412325.55
41.03 Third Year 1.00 Job. 471229.20
41.04 Fourth Year 1.00 Job. 589036.49
41.05 Fifth Year 1.00 Job. 706843.79
Total Amount of Fire Fighting Work ₹
Total Amount of Fire Fighting Work ₹
NAME OF WORK : GCRI Cancer Hospital ELV BOQ
SUMMARY EXTRA LOW VOLTAGE WORK
SR.NO. DESCRIPTION AMOUNT
1 FIRE DETECTION & ALARM SYSTEM ₹
2 PUBLIC ADDRESS & VOICE EVACUATION SYSTEM ₹
3 IP CCTV SURVILLENCE SYSTEM ₹
4 DATA , VOICE & WIRELESS ACCESS POINT SOLUTION ₹
5 ACCESS CONTROL SYSTEM ₹
NAME OF WORK : GCRI Cancer Hospital ELV BOQ
Rate SOR Rate With 1% Estimated
Number SOR NO Qnty may be Item Descriptionan Unit 1% Lc.
In Figure L.C. Amount
Section 01.00 Fire Detection & Alarm System
'SITC of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with 4 Loops
modules and each loop capable of supporting not less than 250 devices (detectors & modules should be in
any combination) ; Loop length up to 1.5 km, 8" Color LCD touch screen display with bright colors to
indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos
of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation
1 NSR 1 speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support Ea. 6,50,000 6500.00 6,56,500.00
10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs
back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have
seamless integration with EVAC certified Public Address System and shall be complete with all accessories
. EN54 / Vds/UL Certification.
SITC of Modbus/Bacnet Gateway for Integration with BMS System. The Modbus/BACNET Gateway shall
act as an independent node communicating on the peer to peer network and shall not be dependant on the
Fire Panel CPU for operation (failure of CPU shall not result in failure of Modbus/BACNET Gateway).
SITC of Fire Graphics software with lifetime license to map, monitor (alarms & faults) & control all the
detector and devices connected to all the Fire alarm panel. The fire Graphics software shall be loaded on the
PC connected to the Fire alarm panel. The GUI based main network software shall network with other
panels on True Peer-to-Peer network. It shall be capable of graphically representing each facility being
3 NSR 1 monitored with floor plans and icons depicting the actual locations of the various systems, and / or sensors’ Ea. 3,50,000 3500.00 3,53,500.00
locations. It shall have the facility to change the sensitivity of any detector.The software shall have
minimum 2000 Points + 20% for future expansion.
FIRE WORKSTATION
SITC of Client Workstation with following configurations: Processor – Intel i7 12th Gen,
GHz,Memory – Minimum 16 GB,Hard disks – 512 GB SDD ,compatible OS for VMS, Network Card –
4 NSR 1 10Gbit/s network card,NVIDIA Graphic card of minimum 4 GB, Dual Port card for connecting Ea. 2,25,000 2250.00 2,27,250.00
minimum of 2 LCD Screen complete with all accessories required to complete the installation as per project
SITC of Active Repeater panel to be connected peer to peer with Main Fire Alarm panel. Accept, Reset
functions shall be possible from the repeater panel. The user interface of Repeater Panel shall be identical to
5 NSR 1 the Fire alarm Panel. All other specification shall remain unchanged like FACP. EN54 / Vds/UL Ea. 1,25,000 1250.00 1,26,250.00
SITC of Addressable Heat Detectors with combination of fixed type and rate of rise of temperature feature.
Detetctor should have inbuilt isolators as per NFPA 72 style 7 wiring requirements and have an option of
both soft & hard addressing. Detector should monitor Electromagnetic interference and report to the panel -
6 NSR 30 current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/ Ea. 3,850 38.50 3,888.50
certification.(Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per
detector) EN54 / Vds/UL Certification.
SITC of Intelligent Addressable Multicriteria detector with a combination of Optical and Thermal
including mounting base, auto addressing feauture as required. Detetctor should have 2 inbuilt isolators as
per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining
operational availability of all elements in the loop in the event of a short circuit and to meet style
7 NSR 970 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement Ea. 3,900 39.00 3,939.00
EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and
average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification.
SITC of Response indicator for mounting on false ceiling at the entries of the cabin for indicating the
operation for detectors in the above areas including Backbox.
SITC of Addresaable Beam detector incuding mounting base along with Interface module to direct connnect
to the loop , having a coverage area with a distance of min. 10 m and max. 100 m with extra width of up to
14 m ,Operating temperature range: -20 C to +55 C, Response sensitivity of 40%. Shall be EN54/ VDs/
SITC of Addessable Manual call point with IP rating of IP 67 and with inbuilt isolators as per NFPA
style 7 wiring requirements, with flexible network structures & necessary fixing arrangements with key
complete as required. Shall be EN 54 / Vds/UL Certification.
SITC of Addressable Loop Powered Indoor Sounder cum Strobe with inbuilt isolators as per NFPA 72 style
7 wiring requirements & with 32 different tone variants selection options & adjustable sound pressure by
11 NSR 28 levels, the sound pressure 92.1 dB(A), with flasher having Synchronized flash rate of 1 Hz and Light Ea. 6,500 65.00 6,565.00
intensity > 2 cd, should be programmed from the panel. Shall be EN54 / Vds/UL Certification.
SITC of Loop Powered Voice Sounder Indoor with inbuilt isolators as per NFPA 72 style 7 wiring
requirements & with 32 different tone variants selection options with 4 different voice messages in
12 NSR 28 languages, the maximum sound pressure 95.4 dB(A) should be programmed from the panel. Shall be EN54 Ea. 12,500 125.00 12,625.00
/ Vds/UL Certification.
SITC of Addressable Control Module with inbuilt isolators as per NFPA 72 style 7 wiring requirements with
a maximun switching current of 1A @ 30V DC. Control module shall be used for to activate Conventional
Sounder cum Strobe/Sounders/Strobes. Shall be EN54/ Vds Certification/UL
SITC of Addressable Control Relay Module with inbuilt isolators as per NFPA 72 style 7 wiring
requirements with a maximun switching current of 1A @ 30V DC. Relay Control module shall be used for
14 NSR 42 emergency control functions including shutting down Fire dampers in AHU's, tripping of AHU's, Fresh air Ea. 3,850 38.50 3,888.50
fans, Ventilation fans, tripping of Access control doors etc.. Shall be EN54/ Vds Certification/UL
SITC of Addressable Monitor Module with one input & one output contacts, with inbuilt isolators & with
monitoring features, monitoring of a line with EOL resistor ,Potential free contact monitoring with Inbuilt
isolators for flow switches, Panic Bars & other Third Party Inputs. Shall be EN54 / Vds/UL Certification.
SITC of Fire Fighter's Master panel along with Master Handset as per the Specifications. Shall be UL
17 NSR 28 SITC of Fire fighters telephone jack as per the specifications. Shall be UL Listed Ea. 5,500 55.00 5,555.00
Supplying of Red colored Fire fighters telephone Handset as per the specifications. Shall be UL Listed
SITC of 2 X 1.5 Sq.mm Fire Survival Armored Cable, for Fire Aalrm Device Looping & Power Supply.
19 NSR 8,000 Outer Sheth Red color. Mtrs. 155 1.55 156.55
Section 02.00 Public Address & Voice Evacuation System
SITC of IP based Digital Public Address and Emergency Sound System Controller certified to International
standards of Emergency Sound System EN 54 and ISO 7240‑16, marked for CE and compliant with the
RoHS directive. The system shall be fully IP-network based and all system devices shall communicate via
IP, using an Audio over IP (AoIP) protocol that supports standards AES67 for audio and using AES70 for
control with optional encryption and authentication to prevent unauthorized access, misuse and
modification of data.It shall be capable of receiving Dante and AES67 audio streams. The audio part shall
support Layer 3 connections via routers between subnets with latency of less than 10ms and synchronized
outputs.The control data part shall be guaranteed by Transmission Control Protocol (TCP) Layer 4. The
system shall support >100 simultaneous channels for music routing and making calls. A system based on a
20 7-10-132 1 single system controller shall support at least 120 system devices and 500 zones.The system controller shall Ea. 6,07,662 6076.62 6,13,738.62
dynamically assign network audio channels for audio routing between system devices across multiple
subnets. The system controller shall have dual power supply inputs and power supplies. It shall keep an
internal log of fault events and call events.The system controller shall provide a secure TCP/IP open
interface for remote control and diagnostics.The system controller shall provide front-panel LED indications
for the status of power supplies and the presence of faults in the system upto 2000 faults and provide
additional software monitoring and fault reporting features. [Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
SITC of The desktop call station with extension keypad with 12 fully programmable keys for zone section
and PA system operation. The call station and the keypad shall be certified for EN 54‑16 and ISO 7240‑16,
marked for CE and be compliant with the RoHS directive.Desktop housing with goose neck microphone.
4.3" full‑color capacitive touch display. Graphical user interface for optimum user guidance and
feedback.Status and fault indicators for voice alarm purposes.Dual Audio over IP‑network ports for
21 7-10-133 5 redundant network. The audio over IP should comply AES 67 standard for audio and AES 70 for control Ea. 5,26,672 5266.72 5,31,938.72
with optional encryption and authentication to prevent unauthorized access, misuse and modification of
data. [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of IP based Digital Class-D multi channel Amplifier 600W each with 8 channels,The amplifier shall
adapt the maximum output power of each amplifier channel to its connected loudspeaker load, with free
assignable output power per channel.EN 54 certified and ISO 7240‑16, marked for CE and compliant with
the RoHS directive.The amplifier shall have a built-in independent spare amplifier channel for automatic
fail over.The amplifier shall provide an interface for control data and multi-channel digital audio over IP
using dual Ethernet ports for redundant network connection, supporting RSTP and loop-through cabling,
with automatic fail over to an analog lifeline input.
The amplifier shall have dual power supply inputs and power supplies.All amplifier channels shall have
independent A/B zone outputs with support for class-A loudspeaker loops.
All amplifier channels shall supervise the integrity of connected loudspeaker lines without interruption of
22 7-10-135 2 audio distribution.The amplifier shall provide front-panel LED status indications for the network link, Ea. 5,83,355 5833.55 5,89,188.55
ground fault, power supplies and audio channels, and provide additional software monitoring and fault
reporting features. Audio‑over‑IP, using the high‑quality digital audio interface, compatible with AES67
and AES 70 standards with optional encryption and authentication to prevent unauthorized access, misuse
and modification of data using an uncompressed, high-definition digital audio format with 24-bit sample
size and 48 kHz sample rate.Digital signal processing on all amplifier channels, including equalization,
limiting and delay, to optimize and tailor the sound in each loudspeaker zone. [Approved by Competent
Authority i.e. not Below the rank of Executive Engineer ]
SITC of Uni-directional microphone on adjustable stem · Built-in plop and windshield ·Low susceptibility
to mobile phones · For acoustical challenging rooms. Microphone stem
Length 310 mm Maximum acoustic input level (dB SPL): 115 dB Microphone stem length (in): 12.21 in
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of Ceiling loudspeaker 6W, ABS with clamps
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of ABS back box [Approved by Competent Authority i.e. not Below the rank of Executive Engineer
SITC of Cabinet loudspeaker, 15W, black High-fidelity music and speech reproduction Selectable 8 ohm,
70 V and 100 V inputs Compact yet robust ABS enclosure Supplied with adjustable mounting bracket
26 7-10-103 5 Complies with international installation and safety regulations Ea. 9,288 92.88 9,380.88
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
27 NSR 1 SITC of Audio Source to play audio using Bluetooth, USB, DVD, FM, IP Streaming. Ea. 1,95,000 1950.00 1,96,950.00
SITC of 2 X 1.5 Sq.mm Fire Survival Armored Cable, for PA Device Looping & Power Supply. Outer Sheth
SITC of 42U 800mm X 800mm, equipment rack with all mountig accesories, power strip 2nos with
sockets M type, caster wheel with lock, front glass & rear perforated door, fan unit on top with 4 fans,
compleate with all required shelves for mounting.
Section 03.00 IP CCTV SURVILLENCE SYSTEM
INDOOR IR DOME CAMERA
SITC of Progressive scan CMOS 5MP, 1/2.8”, 2560 x 1920 pixels, IP Bullet IR, Cameras , Up to 30 fps @
30 NSR 152 1080P, Progressive scan CMOS, 3 to 10mm Verifocal, Colour: 0.08 lux at 33ms, B/W: 0.015 lux at 33ms, Ea. 22,950 229.50 23,179.50
and 0 Lux with IR On Range: Adaptive IR Illumination 50 Mtrs, ONVIF Profile S, Profile G, and Profile T
Conformant, IK10,BI Directional audio, UL listed, IP66 Rated casing etc. PoE+ Power.
OUTDOOR IR BULLET CAMERA
SITC of Progressive scan CMOS 5MP, 1/2.8”, 2560 x 1920 pixels, IP Bullet IR, Cameras , Up to 30 fps @
1080P, Progressive scan CMOS, 3 to 10mm Verifocal, Colour: 0.08 lux at 33ms, B/W: 0.015 lux at 33ms,
31 NSR 15 and 0 Lux with IR On Range: Adaptive IR Illumination 50 Mtrs, ONVIF Profile S, Profile G, and Profile T Ea. 24,150 241.50 24,391.50
Conformant, IK10,BI Directional audio, UL listed, IP66, IP67 Rated casing etc. PoE+ Power.
INDOOR IR BULLET CAMERA
SITC of Progressive scan CMOS 5MP, 1/2.8”, 2560 x 1920 pixels, IP Bullet IR, Cameras , Up to 30 fps @
1080P, Progressive scan CMOS, 3 to 10mm Verifocal, Colour: 0.08 lux at 33ms, B/W: 0.015 lux at 33ms,
32 NSR 12 and 0 Lux with IR On Range: Adaptive IR Illumination 50 Mtrs, ONVIF Profile S, Profile G, and Profile T Ea. 26,150 261.50 26,411.50
Conformant, IK10,BI Directional audio, UL listed, IP66, IP67 Rated casing etc. PoE+ Power.
NETWORK VIDEO RECORDER
SITC of 64 IP Channel Network Video Recorder supports up to 12MP Camera, 256 Uplink Throughput,
256 Downlink throughput, Having 8 SATA Slots , Each Having 16TB HDD Supports, RAID0/1/5/10
33 NSR 3 Supports, 2 Ports x Ethernet (RJ-45) 10/100/1000Mbps, 3 Ports (1x USB 3.0, 2x USB2.0), 2 Alarm Input Ea. 2,61,000 2610.00 2,63,610.00
and 1 Alarm output supports, ONVIF Compatible, Supports SMS & Email Notification,for 60 Days
compresion H.265.
SITC of Client Workstation with following configurations: Processor – Intel i7 12th Gen,
GHz,Memory – Minimum 16 GB,Hard disks – 512 GB SDD ,compatible OS for VMS, Network Card –
34 NSR 8 10Gbit/s network card,NVIDIA Graphic card of minimum 4 GB, Dual Port card for connecting Ea. 2,25,000 2250.00 2,27,250.00
minimum of 2 LCD Screen complete with all accessories required to complete the installation as per project
35 NSR 10 SITC of wall mount 55" Professional Display unit Full HD/4K high resolution diplay with 3XHDMI ports, Ea. 1,55,000 1550.00 1,56,550.00
2XUSB Ports, 1X3.5mm Jack, 1XExternal IR receiver etc.
Section 04.00 DATA , VOICE & WIRELESS ACCESS POINT SOLUTION
36 7-13-5 20,320 SITC of CAT6 UTP 23AWG Solid: Per Meter RMT 43 0.43 43.43
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
Supply, Installation, Testing & Commissioning of CAT 6A UTP Cable including laying, dressing,
termination, testing and commissioning of CAT 6A Unshielded Twisted Pair (UTP) cable suitable for data,
Wi-Fi and CCTV networking applications, complete with all necessary accessories such as ferrules, cable
ties, identification tags, saddles, clamps, sleeves, supports, etc., as required.
Supplying & erecting approved make Telephone Cable electrolytic copper conductor PE insulation twisted
in two pairs, & wrapped with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer Jacket suitable
38 1-4-7 200 for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & Mtr. 442 4.42 446.42
nos.of pairs. With necessary connections. [A] Conductor Size 0.5 mm (b) Armoured [Jelly Filled] (3) Fifty
Supplying & erecting approved make Telephone Cable electrolytic copper conductor PE insulation twisted
in two pairs, & wrapped with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer Jacket suitable
39 1-4-7 300 for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & Mtr. 867 8.67 875.67
nos.of pairs. With necessary connections. [A] Conductor Size 0.5 mm (b) Armoured [Jelly Filled] (4) One
SITC of O. F.Cable 06F Outdoor - Armoured Unitube SM - HDPE Sheath [Approved by Competent
Authority i.e. not Below the rank of Executive Engineer ]
SITC of Jack Cat 6 Keystone UTP
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of Face Plate - Dual (Keystone Jack,square)
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of CAT6 UTP 24AWG PATCH CORD:2M,Plug 30U' Snag less
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of CAT6 UTP 24AWG PATCH CORD:1M,Plug 30U' Snag less
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of Patch Panel Cat 6 UTP Keystone Type- 24 Port-Fully Loaded
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of 24 x 10/100/1000BASE-T PoE ports 4 x Gigabit RJ45/SFP Combo ports Advanced L2 switching
and security features L2+ Static Routing Optional “standard mode” or “surveillance mode” management
45 7-13-15 14 user interface 193 W PoE budget Ea. 31,680 316.80 31,996.80
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of 24 x 10/100/1000BASE-T ports 4 x Gigabit RJ45/SFP Combo ports
Advanced L2 switching and security features L2+ Static Routing Optional “standard mode” or “surveillance
46 7-13-14 18 mode” management user interface Ea. 15,247 152.47 15,399.47
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of 20 x SFP ports 4 x Combo 10/100/1000BASE-T/SFP ports 4 x 10G SFP+ ports 6 kV surge
protection on all RJ-45 access ports Switch Resource Management (SRM) for flexible management of
system resources Redundant Power Supply (RPS) support MPLS L2VPM/L3 VPN support Full L3 routing
47 7-13-18 1 protocol support including OSPF, BGP, and ISIS for IPv4/IPv6 SDN-enabled switch, compatible with Ea. 6,41,524 6415.24 6,47,939.24
Openflow 1.3 10-GbE SFP+ to SFP+ 1M Direct Attach Cable [Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
Supply, Installation, Testing and Commissioning of Core Switch - 4 slots modular chassis architecture,
redundant power supply, redundant fans, advanced Layer 3 features, switch virtualization and high
48 NSR 1 availability for CPU and switch fabric modules. Switch should have 24 ports of SFP+ ports as line cards, Ea. 19,00,000 19000.00 19,19,000.00
a) 1 X 24-port 10/100/1000 RJ45 Ethernet Interface Module
b) 1 X 24-port 10G Ethernet SFP Interface Module
SITC of Maximum distance of up to 10 km Hot-pluggable Single-mode fiber 1000BASE-LX (IEEE 802.3z
standard) Duplex LC connectorMSA, RoHS-compliant [Approved by Competent Authority i.e. not Below
the rank of Executive Engineer ]
Supply, Installation, Testing & Commissioning Wifi6 Access Point controller for controlling upto 100WIFI
50 NSR 1 access point & 500 Users simultaniously. Ea. 5,50,000 5500.00 5,55,500.00
Supply, Installation, Testing & Commissioning Wifi6 Access Point Having 2.4GHz & 5.0GHz Dual Band
802.11ac Wave2 Access Points with 2x2 MU-MIMO, 2 Spatial Streams 802.11b/g/n (300Mbps) and
51 NSR 60 802.11ac (867Mbps); AP should be upgradable to Integrated Bluetooth radio; AP should have 1 Gigabit Ea. 65,000 650.00 65,650.00
port, 1 Management Console Port with License, Embaded control for security policy is must.
SITC of LIU 12 PORT Rack Mount - Loaded (LC) SM
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of PIGTAIL LC SM SIMPLEX LENGTH- 1m
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of PATCH CORD LC-LC SM DUPLEX LENGTH- 3m
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of Digital / PCM / TDM EPABX System having SMT design, system with flexible universal slots.
Inbuilt Auto attendant facility, Minimum 15 Ea. conference, Analog extension line, Calling GSM, E&M
line, PRI / EI & VOIP program me through Analog telephone digital key from Ethernet, public address cord,
shall have unrestricted simultaneous dialing facility,
QSIG protocol on PRI, 95 / STD / ISD / Local-Locking, Class of Service, Quick Dial-Single Digit dialing of
any two external number, Once only ring device, Chairman / Secretary - Do not disturb Facility, Power
Down Mode, Hot Line, Hot Outward Dialing, Day Night Mode, Auto Call Back, Barge-in, Call Pick Up &
55 7-1-2(E) 1 Call Transfer, Call transfer while Ringing with Voice Guide System, (DISA), Caller ID (CLI), CLI Base Ea. 1,72,878 1728.78 1,74,606.78
ECF, CLI Base routing Internet Ready Port, External Music Port, Call Budgeting, Call Most Calculation
(ASMDR), DID Direct Inverse Dialing, External Music Input, Fax Homing, Global Directory Printing with
following capacities [[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ],
[E] No of Extension 128, No of Junctions 24, No of expandable ports : 512, Operators Console -
Compatible : ISDN and Networking
Providing and erecting add on Digital line card suitable for existing system of following ports [Approved
by Competent Authority i.e. not Below the rank of Executive Engineer ] (b) 16 port
Providing & erecting main Distribution (MDF) indoor type, back mounted frame as per DoT standard
57 1-4-9 1 approved with krone strips Ea. 3,409 34.09 3,443.09
(d) Suitable for 100 pair
Providing & erecting main Distribution (MDF) indoor type, back mounted frame as per DoT standard
58 1-4-9 1 approved with krone strips Ea. 6,352 63.52 6,415.52
(e) Suitable for 200 pair
SITC OF 50 Port Telephone Patch panel with RJ-45/12 termination, compleate with mounting accesories.
Supplying & erecting push button type telephone instrument having speaker phone Caller ID & hands free
59 7-1-7 254 dialing system & 30 memories with display system Single line [[Approved by Competent Authority i.e. not Ea. 560 5.60 565.60
Below the rank of Executive Engineer ]
Supplying & erecting push button type telephone instrument having speaker phone Caller ID & speaker
58 7-1-7(a) 10 phone with one touch memory (min.6 nos.)& 99 memories with display system Single line [[Approved by Ea. 890 8.90 898.90
Competent Authority i.e. not Below the rank of Executive Engineer ]
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner
conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly - Aluminium
60 1-4-6 500 film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. Mtr. 39 0.39 39.39
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner
conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly - Aluminium
59 1-4-6 100 film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. Mtr. 62 0.62 62.62
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured / metallic/white front plate , modules erected with necessary
connections as per site situation directed by Engineer In charge.
(4) TV Co-axial Socket outlet Cat.III
SITC of 42U Rack of complete with top mount FAN assembly, 2Nos. Power Strip each with 5Nos. 6/16
Amp Nos. Shuttered socket with 16AMP Plug & MCB & Energy Monitoring on Modbus Rs485, 3 Nos.
60 NSR 3 Horizontal Cable Manager, 1 Nos Shelf, network rack with all accessories. Ea. 52,000 520.00 52,520.00
SITC of 15U Rack of 600MM X 600MM Size, complete with top mount FAN assembly, 2Nos. Power Strip
each with 5Nos. 6/16 Amp Nos. Shuttered socket with 16AMP Plug & MCB & Energy Monitoring on
Modbus Rs485, 3 Nos. Horizontal Cable Manager, 1 Nos Shelf, network rack with all accessories.
ACCESS CONTROL SYSTEM
SMART FACE READER
Supply Installation Testing and Commissioning of Face, Smart Card and PIN based door controller with
OSDP protocol, support Mask Detection, support 50,000 Face in 1:N mode, support 50,000 image logs and
50,00,000 text logs, support AES 256 bit encryption of face template, support operating illuminance with
minimum 0 lux (pitch dark) and maximum 75,000 lux (broad daylight), support live face detection with
62 NSR 12 antispoofing against photograph and video, support 1 in 1000 Crore FAR (false acceptance rate), support No. 18,500 185.00 18,685.00
EM Prox,FeliCa, Mifare and DESfire with Card Module, support minimum 7" IPS LCD Display with
Capacitive Touchscreen, support 1.8 GHz Dual Core + 1.4 GHz Quad Core CPU and 16GB Flash + 2GB
RAM memory, Support secure TLS 1.2 communication with Ethernet, Support Interface with Exit Switch,
Door lock relay, Reader Interface types RS 485 with OSDP, and Wiegand IN/OUT, with Speakers, IP65
certified, support thermal camera integration.
Supply Installation Testing and Commissioning of Electromagnatic type / Door Strick Type Door Lock of
equivivalant of 600LBS. Compleate with all required mounting accessories for mounting on glass / metal /
DOOR POSITION SENSOR
64 NSR 12 Supply Installation Testing and Commissioning of concealed type door position sensor to moniro door No. 450 4.50 454.50
EMERGENCY DOOR RELEASE SWITCH
65 NSR 12 Supply Installation Testing and Commissioning of Emergency door release switch for Exit from controlled No. 1,650 16.50 1,666.50
area incase of emergency situation.
PUSH TYPE DOOR RELEASE SWITCH
66 NSR 12 Supply Installation Testing and Commissioning of Push Type Door release switch on table for allowing No. 1,650 16.50 1,666.50
access to area.
CONTROLLER - MASTER
Supply, Installation, Testing & Commissioning IP based Access controller for (2 Readers, 8 Inputs,
Outputs),With IP54 Panel to mount master/slave controllers & modules power supply modules etc,
cardholder capacity, 50,000 transaction buffer, Supports total of 1 RS-485 IO protocols, 255 access levels
67 NSR 1 per cardholder, Cardholder - 19 Digit (64 Bit) User ID with 15 digit PIN MAX, Activation/Deactivation, No. 33,000 330.00 33,330.00
If/Then macro capabilities Anti-passback support, Nested, area, hard, soft and timed forgiveness, Adjustable
cardholder capacity, Supports up to 520 inputs and 516 outputs. operating voltage - 12 to 24 Vdc ± 10 %,
500 mA maximum.
CONTROLLER - DOOR MODULE
Supply, Installation, Testing & Commissioning of Access controller dooe module for 2 Reader,
communication over RS-485, operating voltage - 12-24 Vdc +/- 10%, 550mA maximum. To be considered
with required power supply module. Dedicated: Tamper and Power Monitor input.
ACCESS CONTROL SOFTWARE
Supply, Installation, Testing & Commissioning of Access Control Software having following features,
Comprehensive Access Control Management, for unlimited users supports, with number of doors
number of connected devices can be expandable up to 1000, maximum number of of acccess levels
maximum number of access groups 2048, maximum number of access Groups per user 16, maximum
69 NSR 1 number of access levels per access Group 128, supports access group auto-synchronisation, maximum 8 No. 4,65,000 4650.00 4,69,650.00
cards per user, maximum 10 numbers of fingerprints per user, supports user auto synchronisation, support
AOC-Access-on-Card, supports security credential cards, supports inactivation user reports, supports
custom fields, supports elevator access control of 192 floors per elevator, supports anti passback interlock
zone, muster zone, scheduled lock or unlock access.
ACCESS CONTROL SERVER
Supply Installation Testing and Commissioning of Minimum specs of Intel Xeon E5 2620 V2 (Octa
Core)3.10 GHz, 15 Mb 1600 MHz, 16 GB RAM, 1TB HDD, MULTI BURNER; RAID 01 in built (M5110e
70 NSR 1 card) ,1TB GB 10K 6Gbps SAS 2.5" SFF G2HS HDD,QLogic 8Gb FC Dual-port HBA for IBM No. 2,27,500 2275.00 2,29,775.00
System x,Microsoft Windows Server Standard, complet asper VMS applicationrequirement and tender
specification. Vendor to confirm and offer requried specification of server to match functional requirement
as per tender specifications.
ACCESS CONTROL OPERATOR STATION
Supply Installation Testing and Commissioning of Client Workstation with following configurations:
71 NSR 1 Processor – Intel i7 4770K/ 3.10 GHz,Memory – Minimum 8 GB,Hard disks – 120 GB SATA at 7200 No. 1,27,500 1275.00 1,28,775.00
rpms,compatible OS for VMS, Network Card – 2Gbit/s network card,NVIDIA Graphic card of 4 GB.
72 NSR 1,200 Supply Installation Testing and Commissioning of 8 Core 0.5 Sq mm Screend Cable for Access Control No. 165 1.65 166.65
Supply Installation Testing and Commissioning of Attendence reader for staff - FACE + BIOMATRIX +
BMS Central Processing Equipment (Workstation) with Color Monitor
Supply, Installation, Testing & Commisioning of Standalone commercialgrade Workstation, features latest
Intel i7 12th Gen , 12th Gen processorwith3.0 GHz or higher, 16 GB
74 NSR 1 RAM,1TBHardDiskdrive,DVDR/RW,DualLANcard, 2GBDualVideo Ea. 1,50,000 1500.00 1,51,500.00
Accelerator,DualMonitorsupport,2Ea.spare USBports, Optical Mouse& keyboard,2 Serial,
parallel,Windowsbased withstandard MSoffice package, Latest
Norton/MacAfeevirusvaccinesuitableforoperationon230 voltsA/C.
50Hz,allasperspecificationsasrequired.Energy star rating ispreferred.
Theprintersshallbesuitablefortrendlog,summary,totalizerlogging,recordingalarmsandprovidingsystemreports.
A hardcopymulti-colorgraphicslaserprinter (compactable A4printer)
forrecordinggraphicdisplaysandassociated dynamic data.
76 NSR 1 OFC Ethernet Switches (One number Hub/Switch not less than 24-port 10/100 Duel Speed port-up to LOT. 1,50,000 1500.00 1,51,500.00
200Mbps) Ethernet switches, 100 base TX, 8 port Miscellaneous Network components
Supply, Installation, Testing & Commissioning of Portable Engineering Workstation / Notebook PC suitable
for PLC/SCADA programming, configuration, diagnostics and monitoring applications, comprising latest
generation Intel Core i7 processor (minimum 3.0 GHz or higher), minimum 16 GB DDR RAM, minimum
TB SSD storage, 24” LED higher Full HD anti-glare color display, integrated Wi-Fi, Bluetooth and LAN
connectivity, USB optical mouse, inbuilt webcam and audio system, preloaded genuine Windows
77 NSR 1 Professional operating system, complete with licensed office utility software, rechargeable battery with Ea. 1,45,000 1450.00 1,46,450.00
minimum 6 hours backup, power adapter, carry backpack/hand bag and all required accessories, suitable for
remote programming, ladder logic development, debugging, online monitoring and data handling for
industrial automation systems, complete as required.
78 NSR 1 BMS Software for E&MforHMI,Event& Alarm, PLC LogicDevelopmentandDebuggingetc. SET 3,50,000 3500.00 3,53,500.00
asperspecificationand support dual display workstation.
DDC/PLC PANEL & IO MODULES.
“Non – SIL RPU/PLC/DDC for SCADA System should have Digital Input, Digital Output, Analog Input
and Analog Output Modules integrated to CPU module along with other required interface or system
module for integration of field signals; should capable of standalone monitoring and control function
irrespective to server communication interface; should fully equipped with dual Power Supply module, OFC
Converter, deviceprotection, all types of requiredtransducers and interface terminals and wiring and other
devices as required to meet tender specification & functional requirement.
PLCProgrammedsoftwareforPLClogicdevelopmentanddebuggingforusewithcompatiblePersonalComputer,
Manufacturer shall provide.
IntegratedRemoteI/OBusManager,96-
wordBasememory,1000I/Ocapacity,64processchannels:1Nos,6slotCPU rack.
79 NSR 1 Al Module as per Signal list with necessary spare I/O consideration. (As per I/O Assignment) Lot. 2,50,000 2500.00 2,52,500.00
80 NSR 1 DI Module as per Signal list with necessary spare I/O consideration. (As per I/O Assignment) Lot. 4,50,000 4500.00 4,54,500.00
81 NSR 1 DO Module as per Signal list with necessary spare I/O consideration. (As per I/O Assignment) Lot. 1,25,000 1250.00 1,26,250.00
82 NSR 1 AO Module l as per Signal list with necessary spare I/O consideration. (As per I/O Assignment) Lot. 1,75,000 1750.00 1,76,750.00
83 NSR 1 RS-485 Communication module for integration with 3rd party & EMS. Lot. 1,50,000 1500.00 1,51,500.00
85 NSR 6 Level Transmitter for water liquid level sensing. Ea. 24,500 245.00 24,745.00
86 NSR 6 Immersion type Temperature Sensor, thermowell type Ea. 4,500 45.00 4,545.00
87 NSR 10 Space / Room Temperature Sensor + RH Ea. 12,500 125.00 12,625.00
88 NSR 1 Outdoor Temperature Sensor + RH Ea. 25,000 250.00 25,250.00
89 NSR 10 Indoor IAQ Sensor Ea. 35,000 350.00 35,350.00
90 NSR 30 Current Switch for Status monitoring. Ea. 3,500 35.00 3,535.00
CONTROL CABLE WIRING
600/1000V grade armored XLPE FRZH Copper (Cu) conductor STP cable screened control cables on
trays/walls/columns/indoor/trenchesincludingthe.costofsupportswithsuitableclamps,cablegland,hooks,boltset
c.and including the cost of proper dressing of cable.
91 NSR 2,000 1 Pair Cable * 1.0 SQ.mm RMT 80 0.80 80.80
92 NSR 800 2 Pair Cable * 1.0 SQ.mm RMT 90 0.90 90.90
93 NSR 600 4 Pair Cable * 1.0 SQ.mm RMT 125 1.25 126.25
94 NSR 300 6 Pair Cable * 1.0 SQ.mm RMT 145 1.45 146.45
SITC of CAT6 UTP 23AWG Solid: Per Meter
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
NAME OF WORK :GCRI Cancer Hospital
SR.NO. DESCRIPTION AMOUNT
1.0 POINT WIRING ₹
2.0 CABLES & ACCESSORIES ₹
4.0 SWITCHGEARS & DISTRIBUTION BOARDS ₹
5.0 LIGHT FIXTURE AND FAN ₹
6.0 EARTHING AND LIGHTINING PROTECTION ₹
7.0 UPS SYSTEM ₹
8.0 WATER COOLER & AC & PUMP ₹
10.0 TRANSFORMER & SUBSTATION EQUP. ₹
11.0 LIAISONING WORK ₹
13.0 TTA PANEL ₹
NAME OF WORK :GCRI Cancer Hospital Electrical BOQ
SOR Rate With 1% Estimated
Number SOR NO Qnty may be Item Descriptionan Unit
SECTION 1.00 POINT WIRING
Point wiring in Copper (Modular)
Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length , in below type of
1 1-2-1-F 1,500 pipe erected with 6A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic/Wooden box, single mounting base frame covered with Pt. 485.81
textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat. III
Point wiring for secondary light point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires, in below type of pipe to be
erected complete with earth continuity and necessary connection with primary light with accessories erected on Metal / PVC / wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic sheet for open
/ concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete
Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe
erected with 6A Modular type switch and hum free EME step type electronic fan regulator mounted and accessories with earth continuity of following type erected on PVC / Metallic/Wooden box, single
3 1-2-2-F. 300 mounting base frame covered with textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed. Pt. 674.68
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat-III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected
complete with Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of
4 1-2-3-I-F 800 accessories. Pt. 510.05
[I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb db board
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat-III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected
complete with Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of
5 1-2-3-II-F 300 accessories. Pt. 745.38
[II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db board.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat-III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected
complete with Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of
6 1-2-3-III-F 300 accessories. Pt. 871.63
[III] For 16A Plug and 16 amp switch with 2-4 sq.mm Cu. Wire with 2.5 sq.mm ( green) earthing wire from mcb d b board.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat-III
Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate
modules erected on / in wall / ceiling with following type accessories Cat-III
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires erected in below
type of pipe with 6A Modular type switches and following type of accessories erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate modules
erected on / in wall / ceiling as per pipe erected. with necessary batten/angle holder or ceiling rose or H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat-III
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected with
9 1-2-6-4. 50 necessary connections as per site situation directed by Engineer In charge. Ea. 160.59
(4) TV Co-axial Socket outlet Cat-III
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected with
10 1-2-6-7. 50 necessary connections as per site situation directed by Engineer In charge. Ea. 25.25
(7) Blank Plate Single Cat-III
11 1-6-11. 5 Call bell gong type suitable for 230 volts, 50 c/s. AC supply complete Erected Ea. 42.42
12 1-6-12. 5 Decorative call bell Ting-tong box type 250 volts complete erected Ea. 71.71
Conduits & Pipes
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive
solution & Clamps with following dia of pipes, in approved manner as directed
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive
14 1-3-2-b. 3,000 solution & Clamps with following dia of pipes, in approved manner as directed Mtr. 32.32
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive
15 1-3-2-c. 100 solution & Clamps with following dia of pipes, in approved manner as directed Mtr. 54.54
Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes, Check-nuts etc. complete of following sizes.
Supplying & erecting UPVC Mini trunking (PVC Casing-n-Capping) having double-locking arrangement with grooves, trunking of size not below 12.5 mm in height as per IS with accessories of PVC/Resin
polypropylene not below 1.8 mm thick duly sealed in joint & erected on wall / ceiling of following size . ..(2) 25 mm
Supplying & erecting UPVC Mini trunking (PVC Casing-n-Capping) having double-locking arrangement with grooves, trunking of size not below 12.5 mm in height as per IS with accessories of PVC/Resin
18 1-3-5-3. 50 polypropylene not below 1.8 mm thick duly sealed in joint & erected on wall / ceiling of following size .(3) 32 mm Mtr. 36.36
Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl, chloride rigid material with ignition free and flame proof confirming BS with necessary end caps Internal and external
19 1-3-6-1 300 bend, flat bends, coupler, tee etc..All necessary accessories and measuring of following sizes Mtr. 277.75
(1) 75 mm x 50 mm trunking
Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl, chloride rigid material with ignition free and flame proof confirming BS with necessary end caps Internal and external
20 1-3-6-2 50 bend, flat bends, coupler, tee etc..All necessary accessories and measuring of following sizes Mtr. 428.24
(2) 100 mm x 50 mm trunking
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm
21 1-4-1. 5,000 copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size Mtr. 62.62
(A) With medium class Rigid PVC pipe and accessories
(a) 2 wire 1.5 sq. mm (FRLS)
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm
copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size
(A) With medium class Rigid PVC pipe and accessories
(b) 2 wire 2.5 sq. mm (FRLS)
providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor
FRLS PVC insulated stranded wire of green colour for earth continuity of following size.
(a) with medium class Rigid PVC pipe and accessories
(a) 2 wire 4 sq. mm
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly - Aluminium
24 1-4-6 300 film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. Mtr. 39.39
SECTION 2.00 CABLES & ACCESSORIES
ARMOURED ALLUMINIUM CABLES.
25 4-3-3. 1,000 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables Mtr. 1,407.94
(J) 3 1/2 core 300 Sq.mm ( 150 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand / Solid Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of
c) 4 Core 10 Sq.mm.
Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to be erected as directed of following size.
(a)7 core 1.5 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or
34 4-4-4. 500 floor of following size of cables. Mtr. 364.61
(B) 4 core 4 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or
35 4-4-4. 500 floor of following size of cables. Mtr. 510.05
(C) 4 core 6 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of
36 4-4-2. 100 following size of cable. Mtr. 287.85
(B) 3 core 4 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of
37 4-4-2. 100 following size of cable Mtr. 395.92
(C) 3 core 6 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of
38 4-4-3. 100 following size of cables. Mtr. 2,197.76
(B) 3 1/2 core 35 Sq. mm ( 16 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of
39 4-4-3. 100 following size of cables. Mtr. 7,572.98
(F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or
40 4-4-4.(A) 100 floor of following size of cables. Mtr. 796.89
(C) 4 core 10 Sq. mm
38 4-6-1. 30 Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Ea. 33.33
(A) 2 to 4 core 2.5 / 4 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.
c) 2 to 4 Core 10 Sq.mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.
d) 2 to 4 Core 16 Sq.mm
Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size
41 4-6-3. 4 of cables. Ea. 75.75
(B) 3 & 1/2 core 35/50 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.
(C) 3 & 1/2 core 70 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.
(D) 3 & 1/2 core 95 Sq. Mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.
(E) 3 & 1/2 core 120 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.
(G) 3 & 1/2 core 185 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.
(I) 3 & 1/2 core 300 Sq. mm
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts
in an approved manner.
(B) 10 Sq.mm (ISI MARKED)
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts
48 4-7-1. 185 in an approved manner. Ea. 15.15
C) 16/25 Sq.mm. (ISI MARKED)
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts
49 4-7-1. 20 in an approved manner. Ea. 20.20
(D) 35/50 Sq.mm. (ISI MARKED)
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts
50 4-7-1. 55 in an approved manner. Ea. 25.25
(E) 70 Sq.mm. (ISI MARKED)
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts
51 4-7-1. 20 in an approved manner. Ea. 40.40
(F) 95 Sq.mm. (ISI MARKED)
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts
52 4-7-1. 50 in an approved manner. Ea. 45.45
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts
53 4-7-1. 65 in an approved manner. Ea. 80.80
( I ) 185 Sq.mm. (ISI MARKED)
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts
54 4-7-1. 200 in an approved manner. Ea. 98.98
(K) 300 Sq.mm. (ISI MARKED)
Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an
55 4-7-2. 35 approved manner. Ea. 8.08
(A) 1.5/2.5 to 6 Sq.mm (ISI MARKED)
Providing and erecting Epoxy Outdoor / Indoor end termination Kit suitable for LT PVC insulated armoured cable1.1 KV grade complete with ferrule bushing and accessories and suitable clamps duly erected
56 4-8-3. 10 and connected to the supply for all cores cables of following size. Ea. 381.78
57 4-5-1. 200 Making trench in soft soil of suitable width of 90 cms deep for laying cable or locating the fault all over the run and backfilling the same and making the surface as normal ground. Mtr. 55.55
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth for laying of
cable. below ground / road surface for enclosing cable
(d)120 mm inner dia.
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth for laying of
cable. below ground / road surface for enclosing cable
(A)50 mm inner dia
Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The cable tray should be bended as per IS 2062/1079 shall be fabricated of double bended channel section longitudinal
members with single bended Channel section. Rungs of members welded to the base of the longitudinal members at 250 mm c/c spacing . as per IS and shall be coated with hot dip galvanizing as per IS
60 .4-11-9 300 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge.. Mtr. 818.10
13 -600 X 100 X 2 mm Thick
Providing and fixing approved make Perforated C type cable tray. Made from pre- galvanized sheet steel. The cable tray should be bended as per IS 2062/1079 . with max 17.5% perforation with coupler plate
60 .4-11-5 1,500 / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge.. Rmt. 322.19
150 X 50 X 1.5 mm Thick
Providing and fixing approved make Perforated C type cable tray. Made from pre- galvanized sheet steel. The cable tray should be bended as per IS 2062/1079 . with max 17.5% perforation with coupler plate
61 .4-11-5 1,500 / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge.. Rmt. 471.67
300 X 50 X 1.5 mm Thick
Providing and fixing approved make Perforated C type cable tray. Made from pre- galvanized sheet steel. The cable tray should be bended as per IS 2062/1079 . with max 17.5% perforation with coupler plate
62 .4-11-5 300 / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge.. Rmt. 274.72
100 X 50 X 1.5 mm Thick
Providing and fixing approved make Perforated C type cable tray. Made from pre- galvanized sheet steel. The cable tray should be bended as per IS 2062/1079 . with max 17.5% perforation with coupler plate
63 .4-11-5 200 / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge.. Rmt. 232.30
50 X 50 X 1.5 mm Thick
Providing and fixing approved make '90° Elbow' for Perforated C type cable tray. Made from pre galvanized sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate / Fish plate and
64 .4-11-7 10 GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge.. Ea. 146.45
150 X 50 X 1.5 mm Thick 90° Elbow
Providing and fixing approved make '90° Elbow' for Perforated C type cable tray. Made from pre galvanized CR sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate / Fish plate
65 .4-11-7 10 and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge.. Ea. 219.17
300 X 50 X 1.5 mm Thick 90° Elbow
Providing and fixing approved make '90° Elbow' for Perforated C type cable tray. Made from pre galvanized CR sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate / Fish plate
66 .4-11-7 10 and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge.. Ea. 108.07
100 X 50 X 1.5 mm Thick 90° Elbow
Providing and fixing approved make '90° Elbow' for Perforated C type cable tray. Made from pre galvanized CR sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate / Fish plate
67 .4-11-7 10 and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge.. Ea. 94.94
50 X 50 X 1.5 mm Thick 90° Elbow
Providing , erecting , fabricating the M.S. structure as per requirement on site incorporating proper size of M.S. angles,square,round, flats, bars, channels, sections complete with cutting, welding, grinding &
finishing duly painted with one coat of red oxide with erection on site as per direction of engineer in charge with necessary grouting, cementing, plastering & finishing complete.. (for Cable Tray support &
SECTION 3.00 SENSOR
SENSOR FOR -Open workstation, Cabins,TOILETS:
69 3-17-2. 15 Providing & erecting stand alone ceiling mount PIR motion Sensor with ABS Housing single phase AC operation. Complete with Dual element pyroelectric sensor, Digital Signal Processing Detection Range NOS 4,366.23
14 feet at 10 feet height, angle 360 degree, RFI and EMI immunity, Detects motion in it's coverage area. Multipurpose device can be used as security device, an energy saving device, an automatic switch.
Complete with infra red sensor, Light & sensitivity Sensor, Timer with Bye pass facility. Suitable for 400 watts electrical load
SECTION 3.00 FLOOR METAL TRUNKING
Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water with all
70 1-3-10 200 accessories,Junction Box,Joints as required and demanded by engineer-incharge and laying/erecting as per OEM guidelines and as per instruction of engineer incharge having following size of dimensions and Mtr. 425.21
No of compartments (W x D x T) cat-III
[7] 50mm x 38mm x 1.6 mm with One Compartments
Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water with all
accessories,Junction Box,Joints as required and demanded by engineer-incharge and laying/erecting as per OEM guidelines and as per instruction of engineer incharge having following size of dimensions and
No of compartments (W x D x T) cat-III
[9] 100mm x 38mm x 1.6 mm with One Compartments
Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water with all
accessories,Junction Box,Joints as required and demanded by engineer-incharge and laying/erecting as per OEM guidelines and as per instruction of engineer incharge having following size of dimensions and
No of compartments (W x D x T) cat-III
[12] 250mm x 38mm x 1.6mm with Three Compartments
Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water with all
accessories,Junction Box,Joints as required and demanded by engineer-incharge and laying/erecting as per OEM guidelines and as per instruction of engineer incharge having following size of dimensions and
No of compartments (W x D x T) cat-III
[13] 300mm x 38mm x 1.6 mm with Three Compartments
SECTION 4.00 SWITCHGEARS & DISTRIBUTION BOARDS
MINIATURE CIRCUIT BREAKERS.
providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996
with ISI Mark Cat.III
Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity
(A) 6 to 32 Amp. Cat-III
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity Cat-III
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity ((QTY FOR MCB OF DB
77 3-10-5. 30 AND MCB OF PANEL)Also consider in general) Cat-III Ea. 595.90
(A) 6-32 Amp Cat.III
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity((QTY FOR MCB OF DB
78 3-10-5. 75 AND MCB OF PANEL)Also consider in general) Cat-III Ea. 668.62
(B) 40 Amp Cat.III
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986 without
MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) (A) single phase incoming and horizontal single phase outgoing
(b) sheet steel double door (IP-43) (ii)6 way
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986 without
MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) (A) single phase incoming and horizontal single phase outgoing
(b) sheet steel double door (IP-43) (iii)8 way
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986 without
MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) (B) three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI)
81 3-11-5. 5 (b) sheet steel double door (IP-43) (ii)6 way Ea. 2,913.85
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986 without
MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) (B) three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI)
82 3-11-5. 55 (b) sheet steel double door (IP-43) (iii)8 way Ea. 3,412.79
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without
MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for
83 3-11-5. 55 (B) three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI) Ea. 4,570.25
(b) sheet steel double door (IP-43)
(iv)12 way Cat-III
Providing & erecting approved make thermo plastic MCB/RCCB distribution board having modular Double door with DIN rails, epoxy powder coated finish metal frame & door assembly with Acrylic/ Plastic
84 3-11-8. 10 door, spring & hinged pins complete with required PVC sleeved 32 / 63A copper Bus strips without MCB / RCCBs Ea. 2,767.40
(e) Two Row 28 Module
Supply installation Testing and commissioning of Surge Protection Device shall be Type-2 for DB LEVEL and IEC 61643-11/2011 T2 and EN 61643-11 Type 2 for internal protection with drill type
EARTH LEAKAGE CIRCUIT BREAKERS.
providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase 240 V,50Hz.
having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed
(i) 25 Amps.DP Cat-III
providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase 240 V,50Hz.
87 3-12-1. 120 having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed Ea. 2,235.13
(ii) 40Amps. DP Cat-III
providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase 240 V,50Hz.
88 3-12-1. 100 having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed Ea. 2,654.28
(iii) 63 Amps. DP Cat-III
Pproviding and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A. with Fixed thermal &
magnetic release suitable to work on A.C. supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing.
Operational Handle Assembly Complete with spreader links and rotary handle.
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same. ICS=100% of ICU only Cat III
SITC of Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating 25A to 125A. with microprocessor release suitable to work on
A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing.
Operational Handle Assembly Complete with spreader links and rotary handle.
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same. ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating 125A. with Fixed thermal & magnetic release
suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing.
Operational Handle Assembly Complete with spreader links and rotary handle.
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same. ICS=100% of ICU only Cat III
SITC of Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating 125A. with microprocessor release suitable to work on
A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing.
Operational Handle Assembly Complete with spreader links and rotary handle.
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same. ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having Normal current rating 200A.with variable Thermal & magnetic release
suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S.housing
Operational Handle Assembly Complete with spreader links and rotary handle.
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same. ICS=100% of ICU only Cat III
SITC of Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating 200A. with microprocessor release suitable to work on
A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing.
Operational Handle Assembly Complete with spreader links and rotary handle.
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same. ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. and above at 415 V . having normal current rating 250A. with variable thermal &
magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing.
Operational Handle Assembly Complete with spreader links and rotary handle.
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same. ICS=100% of ICU only Cat III
SITC of Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating 250A. with microprocessor release suitable to work on
A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing.
Operational Handle Assembly Complete with spreader links and rotary handle.
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same. ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 KA and above at 415 V having Normal current rating 400A. with variable Thermal &
magnetic release suitable to work on A.C.supply 50 c/s. With all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing.
Operational Handle Assembly Complete with spreader links and rotary handle.
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same. ICS=100% of ICU only Cat III
SITC of Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating 400A. with microprocessor release suitable to work on
A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing.
Operational Handle Assembly Complete with spreader links and rotary handle.
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same. ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 K.A. and above at 415 V having normal current rating up to 630A. with variable thermal &
magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing
Operational Handle Assembly Complete with spreader links and rotary handle.
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same. ICS=100% of ICU only Cat III
SITC of Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating 630A. with microprocessor release suitable to work on
A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing.
Operational Handle Assembly Complete with spreader links and rotary handle.
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same. ICS=100% of ICU only Cat III
Approved make standard Draw out type 4 Pole Air circuit breaker. Having 50 kA breaking capacity with ICU=ICS=ICW (1 sec)Vsr=690 v, Ui=1kv ,impulse voltage=12 kv with following type of relay and
(B) with microprocessor Release with over load, short circuit, earth fault protection and metering display in modular design with LED display and Test Trip button facility, CTs and auxiliary contacts, of
101 3-5-4. 5 following current ratings Ea. 1,34,219.91
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same.
(i) 800Amp 50 kA Cat III
Approved make standard Draw out type 4 Pole Air circuit breaker. Having 50 kA breaking capacity with ICU=ICS=ICW (1 sec)Vsr=690 v, Ui=1kv ,impulse voltage=12 kv with following type of relay and
(B) with microprocessor Release with over load, short circuit, earth fault protection and metering display in modular design with LED display and Test Trip button facility, CTs and auxiliary contacts, of
102 3-5-4. 5 following current ratings Ea. 1,40,126.39
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same.
(ii) 1000Amp 50 kA Cat III
Providing and erecting Approved make Earth fault Relay suitable to mount with inter connection suitable to following size of moulded case circuit breaker having CT ratio & MCCB rating as following along
103 3-4-13. 8 with shunt trip 220V AC. with all internal connections & complete erected in existing M.S.housing.. Ea. 4,687.41
Providing and erecting Approved make Earth fault Relay suitable to mount with inter connection suitable to following size of moulded case circuit breaker having CT ratio & MCCB rating as following along
104 3-4-13. 30 with shunt trip 220V AC. with all internal connections & complete erected in existing M.S.housing.. Ea. 4,983.34
Providing and erecting Approved make Earth fault Relay suitable to mount with inter connection suitable to following size of moulded case circuit breaker having CT ratio & MCCB rating as following along
105 3-4-13. 7 with shunt trip 220V AC. with all internal connections & complete erected in existing M.S.housing.. Ea. 5,415.62
Providing and erecting Approved make Earth fault Relay suitable to mount with inter connection suitable to following size of moulded case circuit breaker having CT ratio & MCCB rating as following along
106 3-4-13. 5 with shunt trip 220V AC. with all internal connections & complete erected in existing M.S.housing.. Ea. 6,056.97
Providing & erecting additional parts for Air Circuit Breakers as follows:
(B) Auxiliary Contact Block for CN-CS 800 to 2500 & 6 NO + 6 NC
Providing & erecting additional parts for Air Circuit Breakers as follows:
(G) Shunt Release Type EA:24/48 V, 110V, 220V DC
Providing & erecting additional parts for Air Circuit Breakers as follows:
(I) Under Voltage Release Type MV(2) : 240V AC, 415 V AC
Providing & erecting additional parts for Air Circuit Breakers as follows:
(N) CTs for 1250 C / 1600 C for Fixed & Drawout Type ACBs
Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper Busbars with four equal Nos. of electrolyte bus having current density not more than 1.6 Amp. / sq.mm (Rated current / cross
section area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each bar, erected in
existing cubical panel with necessary connections.
(A) Suitable for 100 Amp. capacity
Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper Busbars with four equal Nos. of electrolyte bus having current density not more than 1.6 Amp. / sq.mm (Rated current / cross
section area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each bar, erected in
112 3-8-1. 5 existing cubical panel with necessary connections. Rn.Mtr 3,202.71
(B) Suitable for 200 Amp. Capacity
Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper Busbars with four equal Nos. of electrolyte bus having current density not more than 1.6 Amp. / sq.mm (Rated current / cross
section area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each bar, erected in
existing cubical panel with necessary connections.
(D) Suitable for 400 Amp. capacity
Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper Busbars with four equal Nos. of electrolyte bus having current density not more than 1.6 Amp. / sq.mm (Rated current / cross
section area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each bar, erected in
existing cubical panel with necessary connections.
(E) Suitable for 630 Amp. capacity
Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper Busbars with four equal Nos. of electrolyte bus having current density not more than 1.6 Amp. / sq.mm (Rated current / cross
section area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each bar, erected in
113 3-8-1. 10 existing cubical panel with necessary connections. Rn.Mtr 13,199.69
(F) Suitable for 800 Amp. capacity
Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper Busbars with four equal Nos. of electrolyte bus having current density not more than 1.6 Amp. / sq.mm (Rated current / cross
section area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each bar, erected in
114 3-8-1. 10 existing cubical panel with necessary connections. Rn.Mtr 16,499.36
(G) Suitable for 1200 Amp.capacity
Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel board necessary IP-42 and above protection as per approval from engineer incharge made from
14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary accesories , supporting angles/ flats channel including cutting, bending, drilling,
welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS, suitable size of inter connecting PVC copper
wire / copper-aluminium strips, rubber grommets, rib, bakelite control fuses/MCB for measuring instruments, earth bus & earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors,
handles with locking arrangement and rubber gasket,heavy duty end terminal connection,danger notice board,necessary ventilation,earthing strip complete. The Panel shall be painted with epoxy powder
115 3-16-1. 15 coating.(The rates excludes the cost of switchgears, bus bars, inter connecting mains & Copper Aluminium strips, meters, Fuses etc. The dimension shall be measured excluding base beams) The panel shall be Sq. Mtr 40,999.94
supplied with following approved manufacturers with following size.
(B) The standard companies switch gear shall be used and only manufacturers at CPRI approved factory
(iv) with 1000 mm. depth
Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel board necessary IP-42 and above protection as per approval from engineer incharge made from
14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary accesories , supporting angles/ flats channel including cutting, bending, drilling,
welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS, suitable size of inter connecting PVC copper
wire / copper-aluminium strips, rubber grommets, rib, bakelite control fuses/MCB for measuring instruments, earth bus & earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors,
116 3-16-1. 20 handles with locking arrangement and rubber gasket,heavy duty end terminal connection,danger notice board,necessary ventilation,earthing strip complete. The Panel shall be painted with epoxy powder Sq. Mtr 19,387.96
coating.(The rates excludes the cost of switchgears, bus bars, inter connecting mains & Copper Aluminium strips, meters, Fuses etc. The dimension shall be measured excluding base beams) The panel shall be
supplied with following approved manufacturers with following size.
(B) The standard companies switch gear shall be used and only manufacturers at CPRI approved factory
(ii) with 550 mm. depth
Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel board necessary IP-42 and above protection as per approval from engineer incharge made from
14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary accesories , supporting angles/ flats channel including cutting, bending, drilling,
welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS, suitable size of inter connecting PVC copper
wire / copper-aluminium strips, rubber grommets, rib, bakelite control fuses/MCB for measuring instruments, earth bus & earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors,
117 3-16-1. 10 handles with locking arrangement and rubber gasket,heavy duty end terminal connection,danger notice board,necessary ventilation,earthing strip complete. The Panel shall be painted with epoxy powder Sq. Mtr 14,902.55
coating.(The rates excludes the cost of switchgears, bus bars, inter connecting mains & Copper Aluminium strips, meters, Fuses etc. The dimension shall be measured excluding base beams) The panel shall be
supplied with following approved manufacturers with following size.
(B) The standard companies switch gear shall be used and only manufacturers at CPRI approved factory .
(i) with 350mm depth
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of
118 1-4-4. 500 following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required. Mtr. 91.91
(f) One wire 10.00 sq. mm
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of
119 1-4-4. 500 following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required. Mtr. 17.17
(b) One wire 1.50 sq. Mm
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of
120 1-4-4. 500 following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required. Mtr. 142.41
(g) One wire 16.00 sq. Mm
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of
121 1-4-4. 500 following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required. Mtr. 27.27
(c) One wire 2.50 sq. mm
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of
122 1-4-4. 500 following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required. Mtr. 37.37
(d) One wire 4.00 sq. mm
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of
123 1-4-4. 500 following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required. Mtr. 56.56
(e) One wire 6.00 sq. mm
Providing and erecting ,Fabricating the box type items made from M.S. Sheet with A.I. supports, wings, doors, handles other hardware materials as per requirement design with finishing by three tank powder
coating processed inside and outside painted, erected as directed including minor civil work.
Painting the number and words for inventory Identification on erected fittings / equipment’s or Such accessories as may required with good quality of enamelled paint as directed by engineer in charge.
125 3-16-7 20 (i) up to 20 characters, up to 50 mm height. Ea. 22.22
Providing , erecting , fabricating the M.S. structure as per requirement on site incorporating proper size of M.S. angles,square,round, flats, bars, channels, sections complete with cutting, welding, grinding &
126 3-16-4-A 50 finishing duly painted with one coat of red oxide with erection on site as per direction of engineer in charge with necessary grouting, cementing, plastering & finishing complete. Kg. 77.77
Supplying and erecting approved make panel mounting type Digital Voltmeter having 3 digits LED display, 0 to 750 AC Volts range erected on existing panel board with all connection, wiring etc .with
manufacturers calibration certificate.
Providing & erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio 15 VA burden erected in existing CRCA box duly secured with insulating materials connected to the meter
Supplying and erecting approved make suitable panel indicator LED type lamp, lens cover, complete erected with necessary connections.WITH SWITCH FOR BMS INTEGRATION FOR ALL FEEDERS OF
PANELS. (For R-Y-B & on-off-trip indication)
Providing and erecting multifunctional meter suitable for application of Power monitoring and showing measurement of following Voltage, Frequency, Apparent energy, Apparent power, Active and reactive
energy, Active and reactive power, Average voltage Vavg, Peak demand power PM, QM, SM, Demand power P, Q, S, Apparent power S, S1, S2, S3, Unbalance current, Power factor and displacement PF
(signed, four quadrant), Calculated neutral current, Active, reactive, apparent energy (signed, four quadrant), Active power P, P1, P2, P3, Voltage U21, U32, U13, V1, V2, V3, Phase currents, Average current
Iag, Peak demand currents, Reactive power Q, Q1, Q2, Q3, Demand current I1, I2, I3, [Us] rated supply voltage 40...300 V AC 45...65 Hz, 40...300 V DC, Network frequency 50 Hz, Type of network 3P,
Display type 7 segments LED, Display colour Red, Messages display capacity 3 fields of 4 characters, Display digits 12 digit(s) - 14.2 mm in height
131 10-3-37. 50 Supplying & fixing Steel Chequered Plate having 7 mm thickness, duly painted with two coats of black Japan colour. (Average Wt 61.1 kg / Sq.Mtr) Sq.Mtr. 3,531.97
Supply, Installation, Testing & Commissioning of following size of Grid Tied Solar Power Plant with
Solar Panels (ALMM approved): Frame Material : Anodized Aluminum alloy Frame With Twin Wall Profile, Front Cover : High Transmission Low-Iron Tempered Glass (AR Coated), High efficency and
positive power tolerance Pmax: 0/+5, Module Efficiency should be approx. 19.5%-22%, Normal operating temperature 45'C, Junction Box with Waterproof IP67 & MC4 Compatible and Enclosed with Bypass
diodes, 100% Electroluminescence test to ensure error free Modules, Thep. temp. co-efficient of the PV module shall equal or better than -0.45%/degree C. Solar PV modules of minimum fill factor 75% to be
used. Unit Production:- More than 4.5 Unit /kw /day (Actual)(1Year Avg) With 10 year Product warranty and 25 year Linear Power Warranty includes all mechanical and electrical parameters of the Solar panel.
Modules must be complied to the DCR(Domestic content requirements). The Ration of AC to DC is 5:6 for the Installation capacity which are given in AC KW.
Solar Inverter: MPPT Range: MPPT Range: 80-1000 V , Max efficiency: 97.5% - 98.9%, O/p Frequency: 50/60Hz, Operating Altitude (m) ≤4000, O/p Power Factor: ~1, O/P THDi: <3%, Operating Tempreture
Range: -25~60°C, Integrated protection of Inverter are Anti-islanding Protection, Input Reverse Polarity Protection, Insulation Resistor Detection, Ground fault protection, Residual Current Monitoring Unit,
Output Over Current Protection, Output Short Circuit Protection, Output Over Voltage Protection, PV array string fault Protection. Protection Degree: IP65, User Interface LCD & APP, Datalogger &
Communication: GPRS / Wi-Fi.
Integrated, Input Reverse Polarity Protection Integrated, Insulation Resistor Detection Integrated, Residual Current Monitoring Unit Integrated, Output Over Current Protection Integrated, Output Short Circuit
Protection Integrated, Output Over Voltage Protection Integrated, Protection Degree: IP65, User Interface LCD & APP,Datalogger & Communication: GPRS / Wi-Fi, Module Mounting Structure: The mounting
(Rectangular pipe / square pipe / circular pipe) with requisite cross bars, nuts and bolts, etc. shall be Hot deep galvanized with minimum 80micron coating. The Rectangular / square /circular hollow pipe
section used for the structure should have a minimum thickness of 2.0 mm. other than above, the material thickness should be minimum 2.5 mm. A certificate of a structural engineer certifying the strength and
stability of the mounting structure to withstand the weight and wind speed of 150 km/hour throughout the life span of 25 years of the system, shall be submitted by the vendors. Hot Dipped Galvanized steel
coils. suitable arrangement for base plate for foundation , solar panel mounting, the structure should be suitable for carry the load of solar panel,wiring, sprinkler system etc. with necessary foundation work/wall
mount, j bolt, anchor fastner etc. the nut bolt used for installtion of stucture should be (SS 304) quality.The ground clearance of the bottom most edge of solar panel shall not be less than 300 mm to 1200 mm or
as per site’s technical/feasibility requirement.
a. Column –The minimum section (thickness) should be 60MM*40MM,b. Rafter - The minimum section (thickness) should be 60MM*40MM
c. Purlin - The minimum section (thickness) should be 40MM * 40MM Balane of System with necessary Swichgears (Suitabel size and protection of ACDB & DCDB), inter connecting wiring, earthing system
as per the CEIG drawing approval, lightining arrester system as per the CEIG drawing approval, all liasoning work with various gov. dipartment like state nodal agency,DISCOM & CEIG is included in agency
scope (D) Grid Tied Solar Power System: 26 - 50 kW (3 - phase)
SITC of All charges namely GEDA Application fees, Solar connectivity Charges, Meter connectivity Charges, Meter testing Charges and system stability/strenthning charges.)
133 NSR 50 PER KW 1,010.00
Supplying & erecting approved make Digital time switch having lithium cell 6 years operative and operate battery backup 1 channel day clock with 14 memory programme, suitable to operate on 240V + 5%,
16A with, floating contacts Minimum switching setup time 1 minimum & LCD display. Also comprised permanent ON/OFF switching. Programming switches & housed in fire proof thermoplastic enclosure &
134 6-7-2. 5 transparent cover erected as required with necessary connection erected as directed. Ea. 3,168.37
135 6-7-5. 5 Supplying & erecting power contactor for time switch complete erected as per direction Cat III [C] 4 pole 440V 16 Amp. Ea. 857.49
136 6-7-5. 5 Supplying & erecting power contactor for time switch complete erected as per direction Cat III [D] 4 pole 440V 40 Amp. Ea. 2,782.55
SECTION 5.00 LIGHT FIXTURE AND FAN
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with diffuser housed in aluminium casted body with company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
137 2-15-3 500 LED driver efficiency > 85 % Nos 1,794.77
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges
(B) LED Panel Light with provision for Plane front frame with translucent cover fixed to housing complete.IP20
(vi) 36 watts, 24" x 24", Surge- 2KV Cat-lll.
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with diffuser housed in aluminium casted body with company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
138 2-15-3 1,200 LED driver efficiency > 85 % Nos 589.84
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded mounting clips complete.IP20
(iii) 16-20 watts, Surge-2 KV Cat-lll.
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with diffuser housed in aluminium casted body with company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
139 2-15-3 800 LED driver efficiency > 85 % Nos 758.51
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded mounting clips complete.IP20
(iv) 22-24 watts, Surge-2 KV Cat-lll.
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/ aluminium die cast powder coated and high U.V. & corrosion resistance with diffuser with company mark/name 160V to 270V, Power Factor more than 0.95, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
140 2-15-1 50 ( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges Nos. 535.30
(A) Tube Light with integral driver
(v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet Cat-lll
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with diffuser housed in aluminium casted body with company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
141 2-15-3 1,200 LED driver efficiency > 85 % Nos. 427.23
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded mounting clips complete.IP20
(ii) 11-15 watts, Surge-2 KV, Surge-2 KV Cat-lll.
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/ aluminium die cast powder coated and high U.V. & corrosion resistance with diffuser with company mark/name 160V to 270V, Power Factor more than 0.9, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
142 2-15-1 100 ( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges Nos. 373.70
(A) Tube Light with integral driver
(iv) 22-24 Watts, Surge - 2KV,IP-20, conventional 4 feet cat-iii
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/ aluminium die cast powder coated and high U.V. & corrosion resistance with diffuser with company mark/name 160V to 270V, Power Factor more than 0.9, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
143 2-15-1 120 ( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges Nos. 165.64
(A) Tube Light with integral driver
(i) 5-10 Watts, Surge-2 KV, IP-20, conventional 1 to 2 feet cat-iii
Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High
pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name
engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)
144 2-16-2.. 20 (A) Street Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with over-voltage protection. Nos. 4,997.48
(ii) above 48 to 60 Watts
Supplying & erecting Steel tubular pole (Swaged) confirming to IS - 2713 (Part-II) 1980. Manufacturing process of steel tubular pole should be as per IS specification. Basic steel tube should be ISI Marked.
Pole should be painted by one coat of Zinc comet Primer and two coat of Aluminium /approved paint to be erected on / in existing Foundation. The length of poles are as below.
(A) 7.5 mtr. Long Swaged Steel tubular pole
145 6-1-3. 20 (i) pole as per IS code 410-SP-4 with 300 X 300 X 4 mm base plate with necessary G.I. J Bolts (Approximate Pole weight 67 Kg) For burial erection,M.S. Base plate 300 X 300 X 16 mm for pole, Suitable for Nos. 8,616.31
mounting on surface of foundation with GI foundation bolts, with required stiffeners welded with pole.PU base primer and PU Paint on pole.
Providing 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation for the pole of size 60 x 60 x 120 cm. Deep in below ground level with plinth of 45 cm x 45 cm(or 45 cm dia x
cm) high upper ground level with necessary curing and finishing in approved manner. ( for 7.5 & 8/8.5 mtr pole)
Providing and erecting Street Light pole bracket comprising main B Class MS pipe of 4.2 cm/require outside dia. complete with suitable B Class M.S. sleeve tubing of approx. 45cms.length and suitable for
mm /80mm / required size of pole top having sufficient fasteners for fixing the brackets and having spread of 1.5.mtr. length with 110 deg.with vertical plane & suitable welded stays, reducer and with check
nuts complete painted with one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint. paint with following nos of arms.
[A] Single Arm Bracket 1.5 Mtr
FANS & ACCESSORIS.
148 5-1-6. 350 Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C. 50 Hz 1200 mm sweep complete having 3blades with aluminium Ea. 1,948.29
blades with , canopy & 30 cm. down rod erected with earthing.(Make shall be approved by Engineer in charge))
FAN ACCESSORIES.
Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with proper insulation without leakage and earthing.
150 5-2-2. 350 Supplying & erecting Fan Hook of 10 mm M.S. Round bar grouted in RCC slab with Making the site as original. Ea. 43.43
TABLE FANS, EXHAUST FANS & ACCESSORIES.
Supplying & erecting approved make low noise decorative exhaust fan having square frame ABS body with inbuilt lowers & square frame.
200mm with 1350RPM Cat.II
152 5-4-2. 5 Supplying and erecting approved make oscillating type bracket fan A.C. 23OV. 50cy/s 400/450 mm sweep wall mounted with height adjustment and rotary tilting device complete with guard, flexible Core plug Ea. 2,534.09
top complete erected with lead wires as directed. Cat.II
SECTION 6.00 EARTHING AND LIGHTINING PROTECTION
Providing and erecting required size HOT deep Galvanised iron strip for earthing of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. using proper clamp.
154 3-14-5 300 Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG.Using for DB earthing wire 8 to 16 SWG. Kg. 77.77
Supplying & erecting funnel type earthing having earth plate of following size burred in specifically prepared earth pit 3 mtr. below ground with 40 kg. charcoal and salt with alternate layers of charcoal & salt,
20mm.dia. G.I. pipe with Funnel with a wire mesh for watering & bricks masonry block, C.I. Cover complete as per para 7.3 of IS 3043 with necessary length of double Galvanised Iron / copper earth wire No
6 SWG bolted with lug to the plate and covered in 12 mm dia. G.I. pipe 2.5 mtr long complete connected to the nearest switch gear with end socket as per direction & duly tested by earth tester confirming to IS
155 3-14-12 16 (As per drawing) with following specification Ea. 7,874.97
(C) with 60 x 60x 0.315 cms. Copper earth Plate
SITC of 14.2 mm dia 3 mtr long Earth electrode of High tensile steel electrode with 250 micron copper bonding & 1 bag of Carbon fill Based environment friendly backfill tested as per IEC 62561-7 in NABL
accredited Laboratory and suitable stainless Steel double sided clamp. Eco Friendly rust proof heavy duty weather proof Polyethylene Earth Pit Chamber with following dimensions :254 mm dia (top), 330 mm
dia (bottom) & 260 mm (height).
SITC of Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000-4000 mm long. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse current withstand test:
kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol with MAST 34mm dia 3000 mm long- Cold Galvanized
SITC of 8 mm dia solid Aluminium Conductor for roof top mesh grid and tested as per IEC 62561- 2 conducted in the Govt. accredited thirty party laboratory to meet the requirement of IS/IEC 62305 with
Required Accessories - Aluminium Holding clamp at every 1 mtr distance, Aluminium/SS cross splicer at every crossing of Alu. conductor, Expansion piece with connectors at every 20 mtr distance, Aluminium
158 10-5-2 300 straight Splicer to connect conductors. All Accessories should be tested as per IEC 62561-1 2018 Cl. 6.3 for conditioning & Ageing Test & 6.4 for Lightning impulse current withstand test: 100 kA of 10/350µs Mtr. 299.97
waveform(Ageing & Electrical test ) conducted in a sequence manner & tested in the Govt. accredited Third party laboratory to meet the requirements of IS/IEC
Supply Installation Testing and Commissioning of Supply of 8 mm Aluminium Round Conductor complete as
specified in drawing & meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC62305). Roof conductor holder for parapet- Polyamide Conductor holder: With M8 female
thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance. Cross universal connector:
For T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8
159 10-5-3 600 hexagonal nuts .Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer.Lightnig counter - To count no of lightning Mtr. 728.21
strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6.
with following type accessories.
(OEM shall conduct survey of the premises and submit feasibility report prior to supply of materials and installation).
SECTION 7.00 UPS SYSTEM
Supplying and erecting approved make online Un-interruptible Power Supply system comprising flat cum-boost charger with IGBT base rectifier & Inverter & sealed maintenance free SMF batteries. The
charger having operating capacity for input 160-270V AC & inverter having output 230V,50 Hz Ac with 0.8 load power factor with battery, over/under voltage output with over load & short circuit protection
equipment. The system housed in CRC sheet duly powder coated paint with following power backup.with MS painted batteries stand, 10% Overload capacity for momentary load.
(I) 10 KVA 3 - phase with 1Hr Backup
Supplying and erecting approved make online Un-interruptible Power Supply system comprising flat cum-boost charger with IGBT base rectifier & Inverter & sealed maintenance free SMF batteries. The
charger having operating capacity for input 160-270V AC & inverter having output 230V,50 Hz Ac with 0.8 load power factor with battery, over/under voltage output with over load & short circuit protection
equipment. The system housed in CRC sheet duly powder coated paint with following power backup.with MS painted batteries stand, 10% Overload capacity for momentary load.
(J) 20 KVA 3 - phase with 1Hr Backup
Supplying and erecting approved make online Un-interruptible Power Supply system comprising flat cum-boost charger with IGBT base rectifier & Inverter & sealed maintenance free SMF batteries. The
charger having operating capacity for input 160-270V AC & inverter having output 230V,50 Hz Ac with 0.8 load power factor with battery, over/under voltage output with over load & short circuit protection
equipment. The system housed in CRC sheet duly powder coated paint with following power backup.with MS painted batteries stand, 10% Overload capacity for momentary load.
(K) 30 KVA 3 - phase with 1Hr Backup
SECTION 8.00 WATER COOLER
Providing & erecting water cooler having storage capacity 150 Ltr. & cooling capacity 150 Ltr.per hour @ an ambient temp of 45˚ C. The outlet temp. of the water should drop by 15˚C within a hour, The water
cooler should be comprising of hermetically sealed compressor, fan motor, condensing unit, water tank surrounded by evaporating, coil, thermostats, relay etc.complete with necessary inlet & outlet connection.
The body of water cooler will be made from Stainless Steel.
SECTION 9.00 HT CABLE
164 NSR 100 Providing and erecting ISI Marked 3core 300 Sq.mm XLPE insulated 11 KV armoured cable Aluminium conductor to be laid on wall with clamps or in provided cable trench / pipe approved manner as Mtr. 3,030.00
Supply, installation,testing and commissioning of Indoor 4 WAY, 11KV PANEL as per SLD, Specification, Technical Data sheet,IS & make list.
Supply, installaton, testing & commissioning of 11KV breaker panel as per Specifications, Technical Data sheet, Standards & Make list with metering unit, comprissing of following:
VCB : 4 Nos. (1No. of I/C & 3 nos. O/G), 11KV, 3 phase, 50Hz, 1 No. 630A, 21 KA, VCB, motor operated spring charge mechanism. Breaker shall be horizontal draw out type. Basic insulation level 28kV
power frequency withstand 75kVp lightening impulse, with closing & tripping coil, auxiliary contact - 4NO + 4NC, mechanical ON / OFF indicator & push button, with mechanical antipumping feature & power
Main busbar - 11Kv, 3phase, 3W, 50Hz, 630A, Al busbar, 21KA for 3 second.
Incomer side CT - 1-phase, epoxy cast resin type, CT ratio of 300/5+5A, BIL:28RMS/75kVp. ( panel builder check CT ration as per standard requirement )
165 NSR 1 core-1: 15VA, CL-1.0, for metering & core-2: 15VA, CL-5P10 for protection. Nos 20,20,000.00
Outgoing Side CT - 1-phase, epoxy cast resin type, CT ratio of 150/5+5A, BIL:28RMS/75kVp. ( panel builder check CT ratio as per standard requirement )
core-1: 15VA, CL-1.0, for metering & core-2: 15VA, CL-5P10 for protection.
Digital Multifunction Meter, CL-1.0
Indication Lamps & protection relays - R,Y,B phase Indications, VCB On and OFF, breaker control switch, Autotrip/trip circuit healthy/ test/ service, spring charge, motor spring charge, Annunciator,
Emergency stop push button, space heater, thermostate and panel illumination, 12 window annunciator, door limit switch for test and service position, BMS compatible.
Protection & Measuring CT ratio change as per transformer sizing shall be calculated by ht panel vendor before finalization.
Protection relays as 50, 50N, 51, 51N, 94 , 86, 27 , 59, 64R. Panel shall be as per SLD and technical specifications.
Supply, installation,testing and commissioning of Indoor 1 WAY, 11KV PANEL as per SLD, Specification, Technical Data sheet,IS & make list.
Supply, installaton, testing & commissioning of 11KV breaker panel as per Specifications, Technical Data sheet, Standards & Make list with metering unit, comprissing of following:
VCB : 1 Nos. (1No. of I/C for torrent), 11KV, 3 phase, 50Hz, 1 No. 630A, 21 KA, VCB, motor operated spring charge mechanism. Breaker shall be horizontal draw out type. Basic insulation level 28kV power
frequency withstand 75kVp lightening impulse, with closing & tripping coil, auxiliary contact - 4NO + 4NC, mechanical ON / OFF indicator & push button, with mechanical antipumping feature & power pack
Main busbar - 11Kv, 3phase, 3W, 50Hz, 630A, Al busbar, 21KA for 3 second.
Incomer side CT - 1-phase, epoxy cast resin type, CT ratio of 300/5+5A, BIL:28RMS/75kVp. ( panel builder check CT ration as per standard requirement )
166 NSR 1 core-1: 15VA, CL-1.0, for metering & core-2: 15VA, CL-5P10 for protection. Nos 5,05,000.00
Outgoing Side CT - 1-phase, epoxy cast resin type, CT ratio of 150/5+5A, BIL:28RMS/75kVp. ( panel builder check CT ratio as per standard requirement )
core-1: 15VA, CL-1.0, for metering & core-2: 15VA, CL-5P10 for protection.
Digital Multifunction Meter, CL-1.0
Indication Lamps & protection relays - R,Y,B phase Indications, VCB On and OFF, breaker control switch, Autotrip/trip circuit healthy/ test/ service, spring charge, motor spring charge, Annunciator,
Emergency stop push button, space heater, thermostate and panel illumination, 12 window annunciator, door limit switch for test and service position, BMS compatible.
Protection & Measuring CT ratio change as per transformer sizing shall be calculated by ht panel vendor before finalization.
Protection relays as 50, 50N, 51, 51N, 94 , 86, 27 , 59, 64R. Panel shall be as per SLD and technical specifications.
Supply, Installation, testing and commissioning Heat Shrinkable type high tension cable end box Indoor type suitable IS: 13573-1992. for 11 KV 300 Sq.mm 3core H.T. cable complete with gland bushing and
jointing material.
SECTION 10.00 TRANSFORMER & SUBSTATION EQUIPEMENT
SITC of 11KV DRY TYPE TRANSFORMER
11/0.433 KV, 3 Phase, 50 Hz Indoor mounting Supply, installation, testing and commissioning of following capacity (continuous loading) 11/0.433 KV Delta/Star,step down, 3 Phase, 50 Hz, Dyn 11 vector
group, Cast Resin / VPI (vacuum pressure impregnated) Dry Type, copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade
MOH or better) AN (air natural) cooled transformer suitable for indoor applications with On Load Tap Changer (OLTC) on HV side having AVS relay and Remote Tap Changer Control (RTCC) for automatic
sensing of incoming voltage, automatic operation of OLTC and facility for remote/ manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, insulation class F (minimum), suitable for
environment conditions class E4, suitable for fire behavior class F1,climate class-C1, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade with necessary hardware, clamps,
lugs etc. for termination on HV/MV etc. for all transformers, bus trunking arrangement on LV side complete with all accessories and safety provisions as per relevant IS Code ,The transformer
shall be provided with standard fittings/accessories as per relevant IS and mentioned below, protection alarm/trip protection, 3 nos. of Polymeric Zinc Oxide surge Arrestors on HV Side. Winding Temperature
scanner (Digital) with alarm/Trip contacts with RTD Sensors per LV winding and space for mounting differential protection CT's in LV chamber with neutral brought out separately including supplying and
167 NSR 2 laying of copper conductor multicore control cable from transformer to HT breaker/HT Panel for safety tripping, complete as confirming to IS-2026 Part-11, i/c supplying and grouting of Ea. 60,60,000.00
suitable M.S. Channel with all accessories ,complete in all respects as required at site as per CPWD specifications . Design ambient condition :a) air temperature 50 deg C, b) Relative Humidity 90 % Max, c)
Seismic Zone as per location of site, d) Altitude as per location/site. The transformer should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location, rating
plate as per relevant IS Code etc. All testing shall as per relevant IS Code. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMAstandard.
Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Rating and terminal marking plates; c) Thermometer pocket with cap; d) Lifting lugs for
the complete transformer as well as for core and winding assembly; e) Bi-directional flat rollers (for transformers above 200 kVA); f) HV side neutral grounding strip (where one of the HV bushing terminal is
connected to earth); g) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. for transformers up to 200 kVA; h) Bird guard; i) Jacking pads (for transformer above 1 600 kVA); j) Name Rating
& Diagram Plate. k) Monogram Plate.i) Additional neutral separately brought out on bushing for earthing.
2000 KVA (losses at 50% loading < 4790watt, losses at 100% loading < 14100watt)
Providing and fixing printed instruction chart both in English and Gujarati and duly framed with front glasses, for treatment of person suffering from Electric shock with minimum 50" diagonally size.
169 10-2-2. 2 Providing pair of rubber hand gloves suitable for working on 11 KV/22 KV supply. Ea. 214.12
170 10-2-3 50 Supplying rubber matting of following thickness as per IS:15652/IEC 61111 (b)4mm Sq.Mtr 1,027.17
Supplying stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal user,
Scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes)
Supplying & erecting D.C.P. type fire extinguisher for following capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and brackets confirming to IS 2171 1985 and complete erected
172 10-2-25. 5 with necessary clamps made from 50 x 6 mm M S Flat with nuts and bolts grouted in wall complete.. [A] For 5 Kg Capacity Ea. 1,712.96
Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in wall complete. [A] For 4.5 Kg
SECTION 11.00 LIAISONING WORK
POWER CONNECTION & STATUTORY APPROVALS
(LIAISONING WORK FOR TORRENT POWER/GEB FOR TRANSFORMER & DG SET as per requirement.
Charges for doing liasioning work for taking power for the premises obtaining the necessary clearances from the Electrical inspector / competent Authorities for the total Electrical installation, co-ordinating
with various agencies. All necessary drawings, calculations, test certificates, etc. as required by these authorities shall be prepared and furnished by the contractor. Any modification/rectification as required by
these authorities shall be carried out by the Contractor.
SECTION 12.00 DG SET
Supplying and erecting, commissioning and testing of Diesel Generating set confirming to IS: 4722:1968 & BS:5514 having continuous rating, 3 phase, 415 volts, 50 cycles A.C. supply comprising of a totally
enclosed air/water cooled diesel engine with multi-cylinders developing suitable BHP not less than following capacity at 1500 RPM with 10% overload for one hour in 24 hours with standard accessories like
fly wheel, lubricating oil cooler, "A" class governor, heavy duty fuel wheel and lubricating oil filter, oil bath air filler, lubricating oil pressure gauge, end exhaust manifold, standard set of tools with adjustable
spanners, screw drivers, cylinder head to cover, joint cylinder head to exhaust, element lube oil filter, 12 / 24 volts electric starting equipment complete with standard heavy duty battery, dynamo, cut-outs,
ammeter, necessary wiring, pressure gauge, starter etc and heavy duty Residential type exhaust silencer (With DEF System) and vertical hot air duct both
logged with asbestos rope, save oil trays, exhaust piping of required length, standard wall/floor mounted fuel with level indicator and piping and drip proof alternator, self excited, self regulated, screen
protected, with excitation system, capable of delivering the rated system output at 415 volts, 3 phase, 0.8 PF, 50 Hz, 4 wire, running at 1500 RPM, conforming to IS-4722- 1968 with voltage regulation +/-
5% of rated voltage from no load to full load. Both the engine and alternator fitted on a common fabricated steel base plate with antivibration mounting engine and alternator both connected to each other by
flexible flange coupling and with floor/wall mounted control panel box comprising of voltmeter ammeter, selector switches, ACB / MCCB / MCB of adequate capacity,
175 10-4-2. 4.00 indicator lamps duly wired with HRC fuses. The alternator & control panel shall be connected with provided suitable capacity armoured cable and complete with Acoustic enclosure (canopy) made out of 16 Nos. 40,58,361.80
SWG CRCA Sheet, sound absorbing material Rockwool of 64 density & 100 mm thick conforming to IS:8183 / PU Foam of 40 Density - at least 40 mm. The resin bonded rockwool covered from inside the
canopy by perforated sheet with 3/4 mm holes, sound level not more than 75 dB at a distance of 1 mtr, as per PVCT norms.DG set should have in built fuel tank capacity of minimum 8 hrs of continous running
capacity on full load . Erection, commissioning and satisfactory testing as per requirement with first filling of fuel (minimum up to the 80% of fuel tank capacity), oil, etc. with guarantee / Warrantee of complete
system for Two years. & with obtaining all necessary certificate from Electrical Inspector. The Capacity and Ratings of DG sets are as below. (As per new CPCB4+ Emission norms Engine With - Turbo
Charger, EGR (Exhaust Gas Recirculation), CRS (Common Rail Fuel System), DOC (Diesel Oxidation Catalyst), SCR (Selective Catalytic Reduction), Integrated wiring harness connected to ECU .)
(V) Continuous rating of 500 KVA ,BHP not less than 600 BHP
Providing & erecting approved make AMF control panel suitable for following size of 3 phase, 415 V., 50 cycles, A.C. diesel generating set complete of scope as detailed below:
1) Power module: A pair of electromechanically interlocked contactors (for mains & generator) Overload relay for generator contactor Neutral contactor for mains and generator Power socket for connections.
2) Control and metering module: Line voltage monitor. Generator voltage monitor Ammeter 3 items attempt start facility. Air circuit breakers/MCB/MCCB of suitable rating for auto/manual operation.
Auto/manual switch. Emergency stop push buttons. Manual start push button. frequency meter. Engine hour meter. Two earthing studs.
3) Protection module: The engine shutdown in the unlikely event of Low lube oil pressure High cylinder head temperature. V belt failure.
176 10-4-3. 4.00 4) Indicators with alarm Load on generator. Nos. 4,43,320.31
5) Indicators Load on mains Engine fails to start . Emergency stop battery charger.
The AMF Panel of following capacity
(G) AMF Control Panel for 500 KVA 3 phase DG Set
Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but
excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all
Note:- The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet
for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
(C.) 200mm dia.
Providing , erecting , fabricating the M.S. structure as per requirement on site incorporating proper size of M.S. angles,square,round, flats, bars, channels, sections complete with cutting, welding, grinding &
178 3-16-4-A 300 finishing duly painted with one coat of red oxide with erection on site as per direction of engineer in charge with necessary grouting, cementing, plastering & finishing complete. Kg. 77.77
SECTION 10.00 LT PANEL TTA-IEC
Supply, installation, assembling, connection, testing and commissioning of TTA (IEC-61439) LT Indoor multi panel board WITH PLC LOGIC PANEL as per specification and approved make list. refer single
line diagram NON SOR MAIN LT PANEL FOR RATING OF OF BREAKER & TYPE OF BREAKER & PLC (WITH HMI SCREEN) LOGIC TABLE.
>Incomer:-2 nos 3200 Amp 4P EDO ACB 50 KA with MP based release having O/L ,S/C, E/F Protection, Under Voltage Communicable Compatible ICU=ICW=ICS=100%, CT connetction,Spring Charge
Motor Health,50 Trip history & Event Record with date & time stamping also with current & voltage percentage THD. WITH 64 R - Resricted Earth Fault Relay, 86- Tripping Relay - CLR, 50 N- Instantaneous
Over Current Relay,51- IDMT Over Current Relay.
-2 nos 1600 Amp 4P EDO ACB 50 KA with MP based release having O/L ,S/C, E/F Protection, Under Voltage Communicable Compatible ICU=ICW=ICS=100%, CT connetction,Spring Charge Motor
Health,50 Trip history & Event Record with date & time stamping also with current & voltage percentage THD. WITH 64 R - Resricted Earth Fault Relay, 86- Tripping Relay - CLR, 50 N- Instantaneous Over
Current Relay,51- IDMT Over Current Relay.
>BUS COUPLER:-1 nos 3200 Amp 4P EDO ACB 50 KA with MP based release having O/L ,S/C, E/F Protection, Under Voltage Communicable Compatible ICU=ICW=ICS=100%, CT connetction,Spring
Charge Motor Health,50 Trip history & Event Record with date & time stamping also with current & voltage percentage THD.
>Bus Bar:-2000 Amp 4P 50 KA al. busbar.
>FOR PLC LOGIC TABLE REFER SINGLE LINE DIAGRAM. Note that PLC LOGIC TABLE shall be change as per detail design.
>Outgoing:-3 nos 1000 Amp 4P EDO ACB 50 KA with MP based release having O/L ,S/C, E/F Protection, Under Voltage Communicable Compatible ICU=ICW=ICS=100%, CT connetction,Spring Charge
Motor Health,50 Trip history & Event Record with date & time stamping also with current & voltage percentage THD.
6 nos 800 Amp 4P EDO ACB 50 KA with MP based release having O/L ,S/C, E/F Protection, Under Voltage Communicable Compatible ICU=ICW=ICS=100%, CT connetction,Spring Charge Motor
Health,50 Trip history & Event Record with date & time stamping also with current & voltage percentage THD.
8 nos 630A,4P,50 KA,MCCB WITH MICROPROCESSOR BASED RELEASE (O/L,S/C,E/F PROTE.) with CT and MFM &ON ,OFF ,TRIP & RYB indication lamps, Potential free contacts for BMS
2 nos 400A,4P,50 KA,MCCB WITH MICROPROCESSOR BASED RELEASE (O/L,S/C,E/F PROTE.) with CT and MFM &ON ,OFF ,TRIP & RYB indication lamps, Potential free contacts for BMS
2 nos 250A,4P,50 KA,MCCB WITH MICROPROCESSOR BASED RELEASE (O/L,S/C,E/F PROTE.) with CT and MFM &ON ,OFF ,TRIP & RYB indication lamps, Potential free contacts for BMS
4 nos 200A,4P,50 KA,MCCB WITH MICROPROCESSOR BASED RELEASE (O/L,S/C,E/F PROTE.) with CT and MFM &ON ,OFF ,TRIP & RYB indication lamps, Potential free contacts for BMS
2 nos 125A,4P,50 KA,MCCB WITH MICROPROCESSOR BASED RELEASE (O/L,S/C,E/F PROTE.) with CT and MFM &ON ,OFF ,TRIP & RYB indication lamps, Potential free contacts for BMS
>ALL ACB/MCCB WITH Auto Manual rotary handle and TNC Switch Emergency Switch and Trip Push Button Earthing,and Fabrication.as per single line diagram
The rate shall include freight, storage, inspection chanrges and conplete installation and required assecories like floor stand and fabrication to mount the panel. with voltage Surge Protection Device 70 KA,2KV
FP VSP Imax=70 KA-2.0 kV(Protection Level )Type -1,2, 230/400 V AC ,high Protection VSP ,protcts appliance against transient micro surges of 8/20 micro second.
As per drawing and design supplied by architect and instruction given by authority and E.I.C.For ACB breaker For communication on ethernet platform,network protocall such as moodbus/ethernet/profinet shall
be actable ,Convertor shall be actable to convert protocall to match with the scada sysytem & necessary hard ware inside the panel it self.
The protocall for the scada system shall be convene during detail design.
Automatic Power Factor Correction Panel (APFC) TTA (IEC-61439)
Automatic Power Factor Correction Panel (APFC) TTA (IEC-61439)
Supply , fixing , connecting and commissioning and testing of TTA (IEC-61439) Automatic Power Factor Correction Panel (APFC) of capacity 415V (at PCC-301 bus-level), 3-phase, 50 Hz.,
800 KVAR . The stage ratings shall be 4x25kVAr + 4x50kVAr +5X100kVAr . The APFC Panel shall be fully type tested and shall comply to IEC 61439-1&2 and IEC 61921, IS 16636-2017. The APFC Panel
shall be (Indoor) type, weather, dust and vermin proof suitable for indoor site conditions (min. temp. -5 degree celsius, design temp. +40 degree celsius, storage temp. of -22 degree celsius, altitude of 3515 m
above m.s.l.). The enclosure system shall be of certified design as per IEC 62208. The enclosure system should have a minimum of IK 10 certification (external mechanical impacts) in accordance with IEC
62262. The degree of protection of enclosures system of the APFC Panel shall be min. IP41 in accordance with IEC 60529. The capacitor bank shall be Internet of things (IoT) enabled and communicable/
integrable with BMS .
Equipment shall be manufactured as directed by the Engineer-in-Charge and shall comprising of the following items (but not limited to) for overall completness of the work , including common copper earth bar
of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid / flexible connections from main bus bar to switchgears and from switchgear output to cable termination in cable alley with required size of AL
conductors / bus bars and control wiring with 2.5 sqmm PVC insulated copper conductor cable (FRLS), cable alleys, cable gland plates in two half,I/C providing switchgears / accessories as per specifications,
including all labour and materials, cable glands, termination, as per approved drawings, specifications, job specification, scope of work, IEC-60947, IEC-60664, IEC-60831 and other relevant codes as
applicable, etc. of this tender and directions of Engineer-in-Charge.
(A) Insulated bus bar pan assembly made from Aluminium and rated of 1600 Amps capacity. The short circuit withstand capacity shall be 50 KA / 1 Sec ( Icw) for the main bus bar and the rated impulse
withstand voltage shall be 6 KV.( B) The incomer of the APFC Panel shall be a 1000 Amp ACB, 50KA, 3 Pole, Ics = 100% Icu , Suitable for Isolation,Adjustable Overload,Adjustable Short Circuit shall have
standard extended rotary handle, spreaders, phase barrier. MCCB shall be of certified design confirming to IEC 60947-1,2 &
180.00 NSR 2.00 (C) Capacitor Units : The capacitor unit shall be metalized polypropylene film with Zn / Al. alloy (total power loss not exceeding 0.50 W/ KVAr). The capacitors shall be encapsulated in an aluminium can. The Ea. 2895872.00
capacitor unit shall have a rated voltage of 525V and shall have a maximum over current capacity of : 1.8 In. The capacitor unit shall have a built in 3 phase over pressure protection and shall have discharge
resistors ( 50V in 1min ) factory fitted and shall be tamper proof. Capacitance Tolerance -5%, +10%. Maximum permissible over voltage 1.1 x Un, 8 h every 24 h. The capacitor unit shall be of certified design
confirming to IS-13340-1993,13341-1992 & IEC -60831-1&2.(D) Reactors : The de-tuning reactors shall be connected in series with each capacitor stage and shall be of iron cored type. The reactors shall have
relative impedance of 7%, with a de-tuning frequency of 135 Hz. approx. The reactors shall prevent amplification of 3th and higher order harmonics. The reactors shall have built in thermostats to protect from
overheating. The reactor insulation shall be min. Class “H” rated at 180 degree C.. The reactors shall be of certified design confirming to IEC-60076 - 6.(E) Short-circuit and Overload Protection : Each stage of
the APFC Panel shall have a suitably rated MCCB with an electronic over-current relay for short-circuit and overload protection. The electronic over-current relay shall be adjusted to trip if the RMS current of
the stage exceeds the overload setting. The MCCB shall be of certified design confirming to IEC 60947-1,2 & 3.(F) PF Regulator : Advanced Range PF Regulator shall have 12 steps with a LCD Display,
Voltage Range : 90V - 550V, 50, CT Input : 1A/5A with a built in RS 485 communication port. The PF Regulator shall be of certified design confirming to IEC 61326.(H) Stage Contactor : The
electromagnetic contactors shall be rated for 660 Volts and shall be 3-pole type and shall be employed for switching 'on' and switching 'off' operations in capacitor banks. The rated voltage of control coil shall be
415V (phase-to-phase). This voltage is subject to a variation of (+) 10% and (-) 15%. The contactor shall be AC3b type. The contactor shall be of certified design confirming to IEC 60947-1 & 4-1.(I)
Ventilating fans of required size shall be used to dissipate the heat produced by the capacitor bank components like the capacitor units, reactors, contactors, breakers etc. The capacitor banks should be of type
tested design and temperature rise test report of the capacitor bank. equivalent to varset.
As per drawing and design supplied by architect and instruction given by authority and E.I.C.
SYNCHRONIZING AMF PANEL
Supply, installation, assembling, connection, testing and commissioning of TTA (IEC-61439) LT Indoor DG SET SYNCH PANEL as per specification and approved make list. refer single line diagram NON
SOR MAIN LT PANEL FOR RATING OF OF BREAKER & TYPE OF BREAKER & SYNCH Relay.
>Incomer:4 NOS 1000 Amp TP WITH NUETRAL ISOLATION CONTACTOR EDO ACB 65 KA with MP based release having O/L ,S/C, E/F Protection, Under Voltage Communicable Compatible and RS-
485 WITH 64 R - Resricted Earth Fault Relay, 86- Tripping Relay - CLR, 50 N- Instantaneous Over Current Relay,51- IDMT Over Current Relay AND SYNCHRONIZING RELAY
>BUSBAR:-3000A 50KA WITH SYNCHRONIZING RELAY ALUMINIUM BUS Current Density:0.8
181 NSR 1.00 >Outgoing:-3 nos. 1600 Amp 4P EDO ACB 50 KA with MP based release having O/L ,S/C, E/F Protection, Under Voltage Communicable Compatible ICU=ICW=ICS=100%, CT connetction,Spring Charge Set 35,35,000.00
Motor Health,50 Trip history & Event Record with date & time stamping also with current & voltage percentage THD. WITH 64 R - Resricted Earth Fault Relay, 86- Tripping Relay - CLR, 50 N- Instantaneous
Over Current Relay,51- IDMT Over Current Relay.
As per drawing and design supplied by architect and instruction given by authority and E.I.C.For ACB breaker For communication on ethernet platform,network protocall such as moodbus/ethernet/profinet shall
be actable ,Convertor shall be actable to convert protocall to match with the scada sysytem & necessary hard ware inside the panel it self.
The protocall for the scada system shall be convene during detail design.
As per drawing and design supplied by architect and instruction given by authority and E.I.C.
SITC of Isolation Panel - 10 KVA with following features: LIM INTEGRATED UNIT WITH: 16 Channel Fault Location Monitoring System VAT (Voltage / Ampere / Temperature) Meter for Transformer
Parameter Monitoring Type Tested as per IEC Standard 60364-7-710 Communication Feature for Integration with HIS / BMS / Surgeon Control Panel.
Design, Fabrication, Assembling, Wiring, Supply, Installation, Testing and Commissioning of Isolation Panels fabricated out of Stainless Steel (304) incubicle compartmentalized Wall Mounted, dust and
vermin proof with reinformcement of suitable size angle iron, channels T sections and / or flats wherever necessary including stainless steel door fitted with stainless screws (Degree of protection IP42).
Knockouts shall be provided at the top of the panel. Panels shall be treated with all anticrossive process before painting. or Design, Fabrication, Assembling, Wiring, Supply, Installation, Testing and
Commissioning of Isolation Panels Fabricated out of Sheet Steel (16SWG) Incubicle Compartmentalized Floor Standing, Dust and Vermin Proof with Reinforcement of Suitable Size Angle Iron, Channels T
Sections and / or flats wherever necessary (Degree of Protection IP42). Knockouts shall be provided at the top of the panel. Panels shall be treated with all Anticrossive Process before Painting.
Approval shall be taken in form of shop drawings before fabrication. Cadmium plated hardware and conform to NFPA / UL / IS / IEC code of pratice shall be used with followings :
1 No. 63 amps DP ELCB 30 mA Leakage Current (Primary side of Transformer).
1 No. 63 amps DP MCB (Secondary side of transformer).
ISOLATION TRANSFORMER:
Rating : 10 KVA,Ratio : 1:1,Primary voltage : 230 V AC + 10%,Secondary Voltage : 230 V AC + 1%,Cooling : Air Cooled,Winding & Type : Copper winding double wound with shield grounded to isolated
ground bus secondary ungrounded,Spike Suppression Level : Not more than 3 dB,Insulation Class : H,Overloading Capacity : 50% for One Hour,Sound level complete Unit with cabinet : Not more than
182.00 NSR 3.00 dB,Line Isolation Monitor : Hazard Index 5 mA. Set 5,05,757.50
Consist of "LIM - INTEGRATED" unit with following monitoring systems Leakage current detector control transformer mother board with relay etc. LIM monitor card.,VAT (Voltmeter, Ampere &
Temperature) Meter for Transformer Parameter Monitoring,Fault Location Monitoring System: With 16 Channel
ADDITIONAL / SPECIAL FEATURES:
Communication Feature for Integration with HIS / BMS / Surgeon Control Panel,Selector Switch for Grounding and Ungrounding Selection with Indication of Ungrounding,with indication lamp,Suitable rating
MCB’s shall be provided for all indicating lamps. Audio / Visual alarm, test / reset PB’s including all accessories as required.Outgoing MCB : 12 Nos. 20 amps DP MCBs.Direct Supply: 2 Nos. 10 amps SP
MCBs . All ELCB shall be of SI/HI-type.All MCB’s shall be minimum of 10 KA breaking capacity & ‘D’ curve only.Ventilation Fans for Cooling of Isolation Transformers shall be provided.
As per drawing and design supplied by architect and instruction given by authority and E.I.C.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
FINAL NIT 25-05-2026.pdf
Final Bid Documents 25-05-2026.pdf
02 Civil Drawings-Part-A.pdf
02 Civil Drawings-Part-B.pdf
03 Electrical Drawings.pdf
04 ELV DRAWINGS.pdf
FINAL BOQ.pdf
05 FIRE DRAWINGS-A.pdf
05 FIRE DRAWINGS-B.pdf
06 HVAC DRAWINGS.pdf
07 PLUMBING DRAWINGS.pdf
09 Make List.pdf
08 FINANCIAL BID.pdf
10 R0_TENDER Purpose Single Line Diagram.pdf
11 TECHNICAL SPECIFICATIONS_Part1.pdf
11 TECHNICAL SPECIFICATIONS_Part2.pdf
Download all tender documents and submit your bid