Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹74,358Accepted-AOC 673636 | MALAPPURAM | KERALA | 673636 | 1 | Accepted-AOC AEE/LIDEW-DIV/MPM/193/25-26 | |
| 2 | 2₹79,323+₹396 (0.50%)Rejected-Finance KARISHOTT HOUSE CHERUVAYKK P O SANTHIDANG K P KRIKOPPARAVISH CHEVIKKULLI KURAKKI P O SUKKOOR BADARATHI WAYANAD 673592 | WAYANAD | WAYANAD | KERALA | 673592 | 2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | GOPAKUMAR A C L1 | MOHANAN K L2 |
|---|---|---|---|---|---|
| 1.00Electrical | |||||
| 1.00 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | 8 | point | 1,543.82 ₹12,350.58 Lowest | 1,551.58 ₹12,412.64 |
| 1.00 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | 3 | each | 387.77 ₹1,163.31 Lowest | 389.72 ₹1,169.16 |
| 1.00 | 90.3.20.3:Supply & installation of light fittings on TW round block
Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture | 2 | each | 1,254.23 ₹2,508.45 Lowest | 1,260.53 ₹2,521.06 |
| 1.00 | OD185123/2025-2026:Supply and fixing 12W LED bulk head fitting heat resistant prismatic glass cover to wall / ceiling P.F 0.9, CRI 80, Body Material: POLY CARBONATE, Input Voltage (V): 180 to 230, Operating Temperature: Upto +45 deg;C, IP20 , THD 10 and making good the surface as required.including giving connections with required length of PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire ect as required (Bajaj/Havells/Lighting Technologies, Dewton/ Lucker/K Lite/Osram make) | 1 | each | 715.15 ₹715.15 Lowest | 718.74 ₹718.74 |
| 1.00 | 19.1:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required: | 3 | each | 2,648.59 ₹7,945.77 Lowest | 2,661.9 ₹7,985.7 |
| 1.01 | 90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required. | 3 | each | 196.18 ₹588.55 Lowest | 197.17 ₹591.51 |
| 1.01 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. | 2 | each | 115.54 ₹231.08 Lowest | 116.12 ₹232.24 |
| 1.01 | OD185124/2025-2026:Supplying and fixing 9 W LED Bulb including connection etc. as required | 2 | each | 150.25 ₹300.49 Lowest | 151 ₹302 |
| 1.01 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). | 4 | each | 502.03 ₹2,008.11 Lowest | 504.55 ₹2,018.2 |
Tender Value
₹79,323
EMD Value
₹1,984
Closing Date
20 Sept 2025, 6:55 pmClosed
ASSISTANT EXECUTIVE ENGINEER
Office of the Executive Engineer, LID and EW Division, Malappuram, civil station, Malappuram District Panchayath Building, Malappuram, 676505
Annual Plan-Malappuram District Panchayath Women Empowerment Center for Kuttiparambu Anganawadi Chelembra-161/25-General Electrical Work(Retender)
2025_LSGD_795931_1
DB1/TN/ELE/AEE/29/25-26
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
MALAPPURAM
Please refer Tender documents.
11 documents required · 11 mandatory
₹590
₹1,984
Yes
5 Feb 2026
12 Sept 2025
22 Sept 2025
12 Sept 2025
20 Sept 2025
12 Sept 2025
Amount
Electrical
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
OD185123/2025-2026:Supply and fixing 12W LED bulk head fitting heat resistant prismatic glass cover to wall / ceiling P.F 0.9, CRI 80, Body Material: POLY CARBONATE, Input Voltage (V): 180 to 230, Operating Temperature: Upto +45 deg;C, IP20 , THD 10 and making good the surface as required.including giving connections with required length of PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire ect as required (Bajaj/Havells/Lighting Technologies, Dewton/ Lucker/K Lite/Osram make)
19.1:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required:
90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD185124/2025-2026:Supplying and fixing 9 W LED Bulb including connection etc. as required
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD185120/2025-2026:Supply, providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system
OD185117/2025-2026:supply and Providing and fixing 25mmx3m GI strip earth lead from the test joint to the earth plate
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
OD185119/2025-2026:Supply and providing 25x6mm brass nut and bolt etc are required
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD185188/2025-2026:Supply & installation of dust and vermin proof, 1 Phase Syntax Meter Board GS-MB-3425-STD-NF and to fix KSEB meters, fuse units, CT etc and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as required.
OD185187/2025-2026:Supplying and Fixing DIN rail inside the existing MCB DB/ Panel/Meter board etc
OD185122/2025-2026:Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board
OD185121/2025-2026:Supplying and fixing 32A, HRC Fuse with HRC Fuse link with connections, in existing meter board
OD185115/2025-2026:Supplying and fixing of suitable sizes of light class PVC conduit along with accessories in surface/ recess including cutting the wall/ground/parapet and making good the same in case of recessed conduit as required as service pipe
OD185125/2025-2026:Supplying and Providing M8 anchor bolt hook in wall/parapet for binding support service wire etc as required
OD185126/2025-2026:Charges for procurement, preparation and submission of application for availing single/three phase KSEB service connection with necessary Sketch, Test and completion report, etc. including necessary liaison work as required.
MOHANAN K (BID ID -2348859)
Bidder Name
GOPAKUMAR A C
MOHANAN K
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1316745.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .