Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC 292 KRISHNA COLONY OLD HAMIDA SAHARANPUR ROAD YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | ₹24.9 L Quoted ₹25.9 L | L1 | Accepted-AOC Acceptance of Contract |
| 2 | L2₹32.0 L+₹6.0 L (23.3%)Rejected-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | ₹32.0 L+₹6.0 L (23.3%) | L2 | Rejected-AOC OK |
| 3 | L3₹35.8 L+₹9.8 L (37.9%)Rejected-AOC 00 KAMALWAGANJA ROAD NEAR HANUMAN MANDIR HARINAGAR SHIV PURAM PHASE 1 HALDWANI NAINITAL UTTARAKHAND 263139 | NAINITAL | UTTARAKHAND | 263139 | ₹35.8 L+₹9.8 L (37.9%) | L3 | Rejected-AOC OK |
| 4 | L4₹36.0 L+₹10.0 L (38.7%)Rejected-AOC 36A 60 CIVIL LINE TELIYAR GANJ ALLAHABAD UTTAR PRADESH 211004 | PRAYAGRAJ | UTTAR PRADESH | 211004 | ₹36.0 L+₹10.0 L (38.7%) | L4 | Rejected-AOC OK |
| 5 | L5₹36.3 L+₹10.3 L (39.8%)Rejected-AOC H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | ₹36.3 L+₹10.3 L (39.8%) | L5 | Rejected-AOC OK |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
23 Apr 2024, 6:00 pmClosed
GE IMA Dehradun
GE IMA Dehradun
REPAIR AND MAINT OF CEILING FAN GEYSERS EXHAUST FAN ETC AND CONNECTED WORKS AT SOUTH COMPLEX UNDER GE IMA DEHRADUN
2024_MES_646895_1
GE/IMA/T-10 of 2024-2025 9397/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE IMA Dehradun
Refer NIT
6 documents required · 6 mandatory
₹500
Yes
GE IMA Dehradun
₹90,000
Yes
21 May 2024
18 Mar 2024
25 Apr 2024
19 Mar 2024
23 Apr 2024
16 Apr 2024
Amount
M&L for taking down non working Ceiling fan of any sweep ( 1200 mm /1400 mm ) from any height , taking it to local workshop for rewinding with super enamelled copper wire of suitable gauge , including required replacement of acccessories such as Capacitors, Bearings , split pin,nut, bolts, washers, gun metal bushes, connecting wire etc and Spray painting ( to provide aesthetic look) of Ceiling fan to make it fully functional and refixing the same at directed place . Important Notes : 1.The rate for items like down rod, clamp , rubber reel, Split pin,Fan Canopy and Cover,nuts ,bolts and washer, connecting wire is deemed to be included in the quoted rate. 2.. After spray painting MES No. and date of repair will be written on the ceiling fan in small size letters , This is the responsibility of Contractor. 3. The standard safety equipments to electricians / helpers will be provided by the Contractor without any additional cost to the department . 4. The tools and plants should be provided by the Contactor to the worker without any extra cost to the dept. 5. The contractor will make good of disturbed surfaces with whatever material required to matchup with existing surfaces without any additional cost to the dept. This condition applies to all the materials in the BOQ.
M&L for taking down non working Exhaust fan of any sweep from any height , taking it to local workshop for rewinding with super enamelled copper wire of suitable gauge , including required replacement of acccessories such as Capacitors, Bearings , split pin,nut, bolts, washers, gun metal bushes, connecting wire etc and Spray painting ( to provide aesthetic look) of Exhaust fan to make it fully functional and refixing the same at directed place . Note : 1. The rate for items like rubber reel, Split pin, nuts ,bolts and washer, connecting wire is deemed to be included in the quoted rate. 2. After spray painting MES No. and date of repair will be written on the exhaust fan in small size letters , This is the responsibility of Contractor.
M&L for taking down non working Wall fan of any sweep from any height , taking it to local workshop for rewinding with super enamelled copper wire of suitable gauge , including required replacement of acccessories such as Capacitors, Bearings , split pin,nut, bolts, washers, gun metal bushes, connecting wire etc and Spray painting ( to provide aesthetic look) of Wall fan to make it fully functional and refixing the same at directed place . Note : 1. The rate for items like rubber reel, Split pin, nuts ,bolts and washer, connecting wire is deemed to be included in the quoted rate. 2. After spray painting MES No. and date of repair will be written on the wall fan in small size letters , This is the responsibility of Contractor.
M & L for taking down Ceiling Fan of any sweep from any height and overhauling/servicing, cleaning, greasing, reassembling,replacing the required part and hanging and testing at site. Note :- (i) The servicing of fan should be done at site only (ii) For servicing purpose Machine oil/grease should be used of appropriate make only. (iii)The rate for Minor spare like Safety pin, Nut Bolts , Rubber Reel,ball bearings etc of any size required at site for change is deemed to be included in the rate. (iv) The payment of major items such as capacitor, fan blades, down rod, gun metal bushes , fan regulator, MS Clamps, Fan hook etc will be made separately.
M & L for taking down Exhaust Fan of any sweep from any height and overhauling/servicing, cleaning, greasing, reassembling,replacing the required part and hanging and testing at site. Note :- (i) The servicing of fan should be done at site only (ii) For servicing purpose Machine oil/grease should be used of appropriate make only. (iii)The rate for Minor spare like Safety pin, Nut Bolts , Rubber Reel, required at site for change is deemed to be included in the rate. (iv) The payment of major items such as capacitor, fan blades, down rod, gun metal bushes , , MS Clamps etc will be made separately.
M & L for taking down Wall Fan of any sweep from any height and overhauling/servicing, cleaning, greasing, reassembling,replacing the required part and hanging and testing at site. Note :- (i) The servicing of fan should be done at site only. (ii) For servicing purpose Machine oil/grease should be used of appropriate make only. (iii)The rate for Minor spare like Safety pin, Nut Bolts , Rubber Reel, required at site for change is deemed to be included in the rate. (iv) The payment of major items such as capacitor, fan blades, down rod, gun metal bushes, regulator, MS Clamps etc will be done separately.
S & F in repairs Capacitor of 2.5 MFD as per site requirement suitable for ceiling fan/ exhaust/cabin/table fan of any sweep.
S & F in repairs Capacitor of 3.15 MFD / 4 MFD as per site requirement suitable for ceiling fan/ exhaust/cabin/table fan of any sweep.
S & F in repairs for Fan regulator electronic 100 watts, 4 step type 230 volts AC complete all as specified and directed.
S&F in repairs modular fan step regulator 100 W 2 module white in colour complete all as specified and directed. Make -Havells ORO(White)/Legrand Lyncus/Indoasian Glint
M&L for Down rod of rigid steel cunduit of size 15 mm Dia 60 Cm Long as required at site for hanging fan with two cut in end of one side pipe and two holes for entering flexible cable both side.
M&L for Down rod of rigid steel cunduit of size 15 mm Dia 90 Cm Long as required at site for hanging fan with two cut in end of one side pipe and two holes for entering flexible cable both side.
M&L for Down rod of rigid steel cunduit of size 15 mm Dia 120 Cm Long as required at site for hanging fan with two cut in end of one side pipe and two holes for entering flexible cable both side.
S & F in repairs for MS clamps with 40mm x 4mm thick flat iron bent to shape any type having center two holes, nuts & bolts for hanging Fans complete complete all as specified and directed
S & F in repairs for fan hook suitable for bearing the load of any type of ceiling fan complete all as directed.
S&F 0.75 Sqmm, 2 core PVC Insulated & Sheathed Copper Flexible Cable Black/white in colour complete all as specified and directed. Make: Polycab/Havells/ SCI / Gems Cab.
S&F 0.75 Sqmm, 3 core PVC Insulated & Sheathed Copper Flexible Cable Black/white in colour complete all as specified and directed. Make: Polycab/Havells/ SCI / Gems Cab.
S&F fan canopy suitable for ceiling fan of any sweep size 1200 mm/1400 mm complete all as specified and directed.
Taking down existing worn out louvers of any description , in any position and supplying & fixing new louvers made out of MS sheet 22 gauge thick suitable for exhaust fan of 250/300mm sweep all as specified & directed by Engineer-in-Charge. ( Note: The louvers shall be of shape, size and pattern as approved by the Engineer-in-Charge duly painted with two coat of synthetic enamel paint over a coat of red oxide primer).
Taking down existing worn out louvers of any description , in any position and supplying & fixing new louvers made out of MS sheet 22 gauge thick suitable for exhaust fan of 450 mm sweep all as specified & directed by Engineer-in-Charge. ( Note: The louvers shall be of shape, size and pattern as approved by the Engineer-in-Charge duly painted with two coat of synthetic enamel paint over a coat of red oxide primer).
Taking down existing worn out louvers of any description , in any position and supplying & fixing new louvers made out of MS sheet 22 gauge thick suitable for exhaust fan of 600 mm sweep all as specified & directed by Engineer-in-Charge. ( Note: The louvers shall be of shape, size and pattern as approved by the Engineer-in-Charge duly painted with two coat of synthetic enamel paint over a coat of red oxide primer).
Supply and fix in replacement Exhaust fan 250 mm sweep, 1200 RPM, ,made up of Sturdy Engineering Plastic complete ,voltage 230 Volts ,50 Hz, energy saving model single phase copper wound motor, white in colour complete with blade, box type louvers etc including taking down old unsv exhaust fan complete all as specified and directed. Make : BAJAJ/HAVELLS /Crompton
Supply and fix in replacement Exhaust fan 300 mm sweep, 1200 RPM, ,made up of Sturdy Engineering Plastic complete ,voltage 230 Volts ,50 Hz, energy saving model single phase copper wound motor, white in colour complete with blade, box type louvers etc including taking down old unsv exhaust fan complete all as specified and directed. Make : BAJAJ/HAVELLS /Crompton
M&L for taking off the unsv water heater and performing following operations with respect to capacity indicated against each item and then refixing the same repaired Water heater at the same position:- NOTE: Fasteners, Connecting wire ( 3 core 2.5 Sq mm wire) wherever necessary will be replaced by Contractor without extra cost to the dept.
Descaling of 25 ltr water heater with Chemical solution.
Descaling of 50 ltr water heater with Chemical solution.
Descaling of 100/150 ltr water heater with Chemical solution.
S&F Non return valves cast copper alloy 15 mm dia ISI mark suitable for any capacity water heater.
S&F Stainless steel Chromium plated assembly with rubber packing ISI marked of any type ( 6 hole/8 hole/9 hole) suitable for 25 ltr / 50 ltr/ 100/150 ltr water heater.
S&F Heating element 230 volt, ISI marked, as per sample for storage type electric water heater including taking down existing unserviceable element complete all as specified and as directed of following capacity:-
2 KW 230 volt,round /triangular type
2.0 KW 230 volt, square/rectangular type
3 KW, 230 volts ISI markded Round shape base .
S & F Thermostat switch 220- 240 volt 16 Amp 0-75° /80° C with autocut features ISI marked as suitable for water heaters of any capacity including taking down existing complete all as specified and as directed.
S&F in repairs Indicating lamp 230 volt AC for water heater of Green & Red colourcomplete all as specified and as directed.
S&F in repairs Heavy duty PVC connection with CP brass nuts and leads PVC washer 02 Nos on each ends for water heater connection of following sizes :-
15mm dia 450 mm long
15mm dia 600mm long
S&F Metal clad Industrial plug top ISI mark, 3 pin with earth, 230 to 250 Volts including taking down existing complete all as specified and as directed.
S&F Metallic fastener screw M 10 of suitable size with bolt for hanging water heater complete all as directed.
S&F Multifunction safety valve cast copper alloy 15 mm dia ISI marked complete including taking down existing valve complete all as specified and as directed.
S&F in repairs Sheet metal enclosure, single pole and neutral with two pin and earth plug and socket with and including one single pole MCB 20. Amps, 240 volts,10 KA complete all as specified and directed. Make: Havells/Legrand/Schneider
S&F MCB SP 6 to 32 Amps, 240 volts 'B' Curve 10 KA, including connection with suitable size copper lugs complete fixed in repair complete all as specified and as directed.Make: Havells/Legrand/Schneider
S&F Bib tap cast copper alloy with crutch or butter fly handle screwed down 15mm bore including taking down existing tap etc complete all as specified and directed.
S&F Stop valve cast copper alloy chromium plated screwed down high pressure with crutch or butter fly handle 15mm bore including taking down existing tap etc complete all as specified and directed.
S&F plug top 3 pin 16 Amp 240 V plastic body white in colour complete all as specified and directed by Engr-in-Charge.Make: Anchor/legrand/havells.
M&L by taking down and shifting of geyser of any capacity from one location to another location as per requirement and refixing complete all as specified and directed.
S&F Steel inner tank of 25 litre capacity geyser tank by made out of stainless steel sheets appropriate thickness complete all as specified and as directed by Engr-in-charge.
S&F Steel inner tank of 50 litre capacity geyser tank by made out of steel sheets appropriate thickness complete all as specified and as directed by Engr-in-charge.
S&F Steel outer tank of 25 litre capacity geyser tank by made out of steel sheets appropriate thickness complete all as specified and as directed by Engr-in-charge.
S&F Steel outer tank of 50 litre capacity geyser tank by made out of steel sheets appropriate thickness complete all as specified and as directed by Engr-in-charge.
Supply only Insulating material (glass wool for Geyser) complete, all as specified and as directed by Engr-in-charge.
S & F sub main wiring with PVC insulated unsheathed FRLSH cable 1100 Volt grade, with multi stranded copper conductor drawing in and including rigid PVC conduit of size not less than 25 mm dia in concealed as required at site including one run PVC insulated unsheathed cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB including taking down old unsv submain wiring of following sizes complete all as specified and directed. Make of wire: Havells/ Polycab /Grandlay/SCI. Make of conduit: Bhagwati Plastic/AKG Plastic/Modi Note: (i) Two/Four run of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface with using PVC rawl plugs etc. (iii) Phase sequence colour code must be follow i.e Phase( Red) and Neutral ( Black) In colour and for three Phase RYB For phase,black for neutral and green for earth conductor.
2 x 10 Sqmm + 1 x 10 Sqmm
2 x 6 Sqmm + 1 x 6 Sqmm
2 x 4 Sqmm + 1 x 4 Sqmm
4 x 16 Sqmm+ 1 x 10 Sqmm
4 x 10 Sqmm+ 1 x 10 Sqmm
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in Cement Mortar 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20 mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge.
S & F in replacement VTPN Distribution boards epoxy powder coated fabricated from minimum 1.6 mm thick CRCA sheet and fixed/ flush to wall and suitable for universal mounting with fully insulated 250 Amps copper Bus Bar for each phase and 02 neutral shrouded bar ,2 earth bar and cable tie for cable management with reversible door for IP-43 IK -09, ,415 volt with provision for 160/200 Amp MCCB FP as incomer and SP MCBs or TP MCBs as per site requirement (or any combination of SP/TP MCBs) outgoings of following capacity . Make:- Legrand/L&T/Siemens.
4 Way VTPN DB (FP MCCB + 12 MCBs).
8 WAY VTPN DB TP&N DB(FP MCCB + 24 MCB,s)
S & F in replacement MCB DB complying with IEC 61439 -1 & 3., sheet metal enclosures double door with provision for 01 x 40 to 63 A SPN MCB as incoming and MCB SP 6 to 32A as out going as per way of DB.The DBs should be supplied with tin platted insulated copper bus bar rated for 200A. 240 volts 2 in 1 shutter (Metal Door) with IK09 type with blanking plates where required and IP 43 degree protection, the DB door should be hinged type and possible to reversible at site.The DB door shall have overhang, to gel with wall properly.The DB shall be supplied with all insulated N. Bar riveted on Din channel frame and should not restrict cable entry from top or bottom.The DB shall have plastic knobs on shield to hold complete all as directed of following capacity. Make: Legrand/ L&T/Siemens
8 way SPN DB.
12way SPN DB.
S & F in repairs 6 Sqmm 2 core 1100 volts grade heavy duty twin flat cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed complete all as directed.
S & F in replacement MCB SP MCB SPN 40 to 63 Amps 240 volts complying to IS/IEC 60898, 240 volts 'B' Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 6A to 63A . The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable complete all as directed of follwing capacity: Make:- Legrand/L&T/Siemens
S & F in replacement TPN DB 4 way complying with IEC 61439 -1 & 3., sheet metal enclosures double door with provision for 01 x 63/100 A `TPN MCB as incoming and MCB SP 6 to 32A as out going as per way of DB.The DBs should be supplied with tin platted insulated copper bus bar rated for 200A. 240 volts 2 in 1 shutter (Metal Door) with IK09 type with blanking plates where required and IP 43 degree protection, the DB door should be hinged type and possible to reversible at site.The DB door shall have overhang, to gel with wall properly.The DB shall be supplied with all insulated N. Bar riveted on Din channel frame and should not restrict cable entry from top or bottom.The DB shall have plastic knobs on shield to hold complete all as directed of following capacity. Make: Legrand/ L&T/Siemens
S & F in replacement MCB TPN/FP 40 to 100 Amp as per requirement complying to IS/IEC 60898, 240 volts 'B' Curve 10 KA with energy limiting class 3. The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable complete all as directed of follwing capacity: Make:- Legrand/L&T/Siemens
S & F in replacement of MCCB at 415 V with rupturing capacity as mentioned below with thermal-magnetic release and adjustable overload setting complete all as specified and directed of following capacity. Make:- Legrand/L&T/Siemens
125 Amps 3 pole 16 KA
160 Amps 4 pole 36 KA
200 Amps 4 pole 36 KA
JS CONSTRUCTION COMPANY
M/S K K ENTERPRISES
PRAGATI ENTERPRISES
PARADISE INFRA POWER COMPANY
Meher enterprises
M/s RK ENTERPRISES
KRISHANA ELECTRIC WORKS
Deven Associates
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .