Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.6 LAdmitted-Finance 171 NARAYAN PETH PUNE PUNE MAHARASHTRA 411030 | PUNE | MAHARASHTRA | 411030 | L1 | Admitted-Finance | |
| 2 | L2₹45.4 L+₹86,773 (1.95%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹46.1 L+₹1.6 L (3.52%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹46.9 L+₹2.3 L (5.25%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹47.3 L+₹2.8 L (6.25%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | S.k ENTERPRISES L2 | Ms. S.K. ASSOCIATES L5 | M/s AG PATHAN L9 | KAMINS CARE L7 | Maruti Abhiyantriki L4 | J B ELECTRICALS L3 | BHAVIN INFRA L8 | KESARI AND SONS L1 | M/s Swaroop Enterprises L11 | AZAD SERVICES L6 | m/s shivam tools and equipment L10 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply & Fixing and testing of LT cable 1100 volts grade, XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) ISI Marked with aluminium conductor suitable for earthed system of size 300 sq mm 3.5 core in trenches, on poles and in ducts complete all as specified and directed by Engr in charge. | 200 | RM | 2,070 ₹4,14,000 | 2,010 ₹4,02,000 | 2,024 ₹4,04,800 | 2,020 ₹4,04,000 | 2,100 ₹4,20,000 | 1,436 ₹2,87,200 Lowest | 1,980 ₹3,96,000 | 1,729 ₹3,45,800 | 2,040 ₹4,08,000 | 2,100 ₹4,20,000 | 2,050 ₹4,10,000 |
| 2.00 | -- do-- all as per ser item no 1 above but size 150 sq mm 3½ core | 180 | RM | 1,142 ₹2,05,560 | 1,100 ₹1,98,000 | 1,200 ₹2,16,000 | 1,100 ₹1,98,000 | 1,170 ₹2,10,600 | 766 ₹1,37,880 Lowest | 1,100 ₹1,98,000 | 900 ₹1,62,000 | 1,300 ₹2,34,000 | 1,050 ₹1,89,000 | 1,190 ₹2,14,200 |
| 3.00 | -- do-- all as per ser item no 1 above but size 120 sq mm 3½ core | 250 | RM | 972 ₹2,43,000 | 1,000 ₹2,50,000 | 1,150 ₹2,87,500 | 1,025 ₹2,56,250 | 1,025 ₹2,56,250 | 654 ₹1,63,500 Lowest | 1,010 ₹2,52,500 | 819 ₹2,04,750 | 1,200 ₹3,00,000 | 960 ₹2,40,000 | 990 ₹2,47,500 |
| 4.00 | -- do-- all as per ser item no 1 above but size 95 sq mm 3½ core | 100 | RM | 810 ₹81,000 | 900 ₹90,000 | 800 ₹80,000 | 750 ₹75,000 | 900 ₹90,000 | 531 ₹53,100 Lowest | 850 ₹85,000 | 675 ₹67,500 | 900 ₹90,000 | 750 ₹75,000 | 900 ₹90,000 |
| 5.00 | -- do-- all as per ser item no 1 above but size 70 sq mm 3½ core | 300 | RM | 666 ₹1,99,800 | 580 ₹1,74,000 | 655 ₹1,96,500 | 650 ₹1,95,000 | 700 ₹2,10,000 | 447 ₹1,34,100 Lowest | 620 ₹1,86,000 | 555 ₹1,66,500 | 720 ₹2,16,000 | 650 ₹1,95,000 | 630 ₹1,89,000 |
| 6.00 | -- do-- all as per ser item no 1 above but size 50 sq mm 3½ core | 200 | RM | 549 ₹1,09,800 | 540 ₹1,08,000 | 600 ₹1,20,000 | 575 ₹1,15,000 | 540 ₹1,08,000 | 340 ₹68,000 Lowest | 580 ₹1,16,000 | 425 ₹85,000 | 680 ₹1,36,000 | 550 ₹1,10,000 | 590 ₹1,18,000 |
| 7.00 | -- do-- all as per ser item no 1 above but size 16 sq mm 4 core | 900 | RM | 207 ₹1,86,300 | 300 ₹2,70,000 | 320 ₹2,88,000 | 365 ₹3,28,500 | 280 ₹2,52,000 | 195 ₹1,75,500 Lowest | 350 ₹3,15,000 | 223 ₹2,00,700 | 400 ₹3,60,000 | 300 ₹2,70,000 | 355 ₹3,19,500 |
| 8.00 | -- do-- all as per ser item no 1 above but size 10 sq mm 4 core | 1,100 | RM | 175 ₹1,92,500 | 195 ₹2,14,500 | 185 ₹2,03,500 | 180 ₹1,98,000 | 170 ₹1,87,000 Lowest | 176 ₹1,93,600 | 170 ₹1,87,000 Lowest | 219 ₹2,40,900 | 190 ₹2,09,000 | 200 ₹2,20,000 | 175 ₹1,92,500 |
| 9.00 | -- do-- all as per ser item no 1 above but size 10 sq mm 2 core
Note for Sr No 01 to 09 : Excavation & Earthwork, Protection pipe etc shall be measured and paid seprately under relevent items of this Schedule. | 1,000 | RM | 153 ₹1,53,000 | 175 ₹1,75,000 | 145 ₹1,45,000 | 150 ₹1,50,000 | 140 ₹1,40,000 Lowest | 145 ₹1,45,000 | 140 ₹1,40,000 Lowest | 149 ₹1,49,000 | 150 ₹1,50,000 | 170 ₹1,70,000 | 150 ₹1,50,000 |
| 10.00 | Excavation in trenches nexc 1.5 mtr in depth and not exceeding 1.5 Mtr wide for laying of cable/pipe etc and getting out in any type of soil complete all as specified nad directed. | 1,000 | CUM | 120 ₹1,20,000 | 110 ₹1,10,000 | 100 ₹1,00,000 Lowest | 125 ₹1,25,000 | 140 ₹1,40,000 | 387 ₹3,87,000 | 130 ₹1,30,000 | 180 ₹1,80,000 | 100 ₹1,00,000 Lowest | 110 ₹1,10,000 | 125 ₹1,25,000 |
Tender Value
₹45.6 L
EMD Value
₹92,000
Closing Date
1 Dec 2025, 6:00 pmClosed
Garrison Engineer (North) Ahilyanagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahilyanagar 414 002
SPECIAL REPAIR / REPLACEMENT OF LT CABLE OVERHEAD LINE TO UNDERGROUND LT CABLE AND CONNECTED ACCESSORIES AT CAV CANTEEN COMPLEX, SINGLE JCOs LIVING AE REGT, OLD SIGNAL CENTRE, HQ RTG AND CHRUCH UNDER GE NORTH AHILYANAGAR.
2025_MES_739034_1
8160/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer (North) Ahilyanagar
As per NIT
8 documents required · 8 mandatory
₹500
Garrison Engineers (North) Ahilyanagar
₹92,000
Yes
5 Dec 2025
10 Nov 2025
3 Dec 2025
10 Nov 2025
1 Dec 2025
24 Nov 2025
Amount
Supply & Fixing and testing of LT cable 1100 volts grade, XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) ISI Marked with aluminium conductor suitable for earthed system of size 300 sq mm 3.5 core in trenches, on poles and in ducts complete all as specified and directed by Engr in charge.
-- do-- all as per ser item no 1 above but size 150 sq mm 3½ core
-- do-- all as per ser item no 1 above but size 120 sq mm 3½ core
-- do-- all as per ser item no 1 above but size 95 sq mm 3½ core
-- do-- all as per ser item no 1 above but size 70 sq mm 3½ core
-- do-- all as per ser item no 1 above but size 50 sq mm 3½ core
-- do-- all as per ser item no 1 above but size 16 sq mm 4 core
-- do-- all as per ser item no 1 above but size 10 sq mm 4 core
-- do-- all as per ser item no 1 above but size 10 sq mm 2 core Note for Sr No 01 to 09 : Excavation & Earthwork, Protection pipe etc shall be measured and paid seprately under relevent items of this Schedule.
Excavation in trenches nexc 1.5 mtr in depth and not exceeding 1.5 Mtr wide for laying of cable/pipe etc and getting out in any type of soil complete all as specified nad directed.
ditto all as per ser Item No.10 above but exceeding 1.5 mtr & not exceeding 3 mtr in depth.
Returning filling in trenches excavated soil including spreading levelling watering and well ramming in layers n.exc 25 cm thick each layer as in soil complete all as specified nad directed..
Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified nad directed.
Supply & laying of HDPE DWC pipe ISI mark of outer dia 110 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable icluding coupler and bends etc complete all as specified and directed by Engineer-in-Charge Make : Supreme / Infra / Astral/Prince/jain irrigation
Supply & laying of HDPE DWC pipe ISI mark of outer dia 63 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable icluding coupler and bends etc complete all as specified and directed by Engineer-in-Charge Make : Supreme / Infra / Astral/Prince/jain irrigation
M&L for GI Tubes,of size 40mm dia Medium grade, galvanised, with all fitting, laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
M&L for GI Tubes,of size 50mm dia Medium grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
M&L for GI Tubes,of size 80mm dia Medium grade, galvanised, with all fitting, laid in trenches for protection of cable in road / drain crossing complete all as specified and as directed.
M&L for road cutting upto 300mm deep and 200mm wide for crossing GI pipe line through road including making good the disturbed surface by filling mass concrete( 1:2:4) etc complete all as specified and directed by Engineer-in-Charge. Note : Rate of mass concrete will be included in quoted rate.
Demolation of u/s cement concrete in coppings etc complete all as specified and directed by Engineer-in-Charge.
M & L for PCC(1:2:4) type C-2 using 20mm grade stone aggregates for coping and similar work including necessary formwork all as specified and directed.
M & L for PCC(1:3:6) type C-2 using 40mm grade stone aggregates as foundation of pole and similar work all as specified and directed.
S&F PVC Junction box of size 250x200x100mm, IP 66 with hinged door including locking arrangment and MCB SP 6 Amp with necessary nut,bolt etc and including TPN aluminium bus bar mounted on insulators with suitable holes to provide incoming and outgoing LT cables and street light MCB complete all as specified and directed
Supply and fixing wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, Three core cable in surface/recessed as required 2x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire (From PVC Junction box to Security light)
Supply, installation, testing and commissioining factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification,double door floor mounted outdoor type,as per IP-65 grade,made out of CRCA sheet 3.15 mm thick of outer body of suitable size with Aluminium bus bar 500 Amps,4 strip,(3 phase & Neutral) complete drilled,insulated with colour coaded insulation tape,mounted on insulators etc with RYB indicater,internal wiring with suitable size of copper wire,panel should be dust proof,vermin proof,powder coated,locking should be screw type,mechanical type,inter locking,should have danger notice for 415 volt,AC,mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearanceduly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including ternination of all incoming and outgoing cables with suitable size thimbles/lugs and stainless steel glands Nuts & Bolts complete all as specifid and directed.(Main Panel)Note: All MCCB Shall be Thermal and Magnetic adjustable type as per IEC 6047-II ( old exchange main panel) (i) Incoming MCCB 4P, 315 Amp, 36 KA,thermal and magnetic adjustable -01 No ( Ics = 100% Icu) (ii) Outgoing -Al bus bar 100 Amps (iii) Outgoing MCCB 4P 160 Amp, 36 KA -02Nos ( Ics = 100% Icu) (iii) Outgoing MCCB 4P 200 Amp, 36 KA -01Nos ( Ics = 100% Icu) (iv) Digital voltmeter & Ammeter with necessary CTs (v) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of approriate size but not less than 2.5 sqmm (vi) Phase indicating LED lamps (R-Y-B) -01 set
Supply, installation, testing and commissioining factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification,double door floor mounted outdoor type, as per IP-65 grade, made out of CRCA sheet 3.15 mm thick of outer body of suitable size with Aluminium bus bar 1000 Amps,4 strip, (3 phase & Neutral) complete drilled,insulated with colour coaded insulation tape,mounted on insulators etc with RYB indicater,internal wiring with suitable size of copper wire, panel should be dust proof,vermin proof,powder coated,locking should be screw type,mechanical type,inter locking,should have danger notice for 415 volt,AC,mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearanceduly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including ternination of all incoming and outgoing cables with suitable size thimbles/lugs and stainless steel glands Nuts & Bolts complete all as specifid and directed.(Main Panel)Note: All MCCB Shall be Thermal and Magnetic adjustable type as per IEC 6047-II ( old exchange main panel) (i) Incoming MCCB 4P, 630 Amp, 50 KA,thermal and magnetic adjustable -01 No ( Ics = 100% Icu) (ii) Outgoing -Al bus bar 100 Amps (iii) Outgoing MCCB 4P 315 Amp, 36 KA -02Nos ( Ics = 100% Icu) (iii) Outgoing MCCB 4P 200 Amp, 36 KA -02Nos ( Ics = 100% Icu) (iv) Digital voltmeter & Ammeter with necessary CTs (v) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of approriate size but not less than 2.5 sqmm (vi) Phase indicating LED lamps (R-Y-B) -01 set (vii) Spare chamber for MCCBs - 01 Nos
M & L for fabrication of bus bar chamber of size not less than 600 x 600 x450 mm suitable for 415 volts 3 phase 4 wire system , outdoor type, double door, with pedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and out going cable including grouting of panel board 60 cm above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge Incoming MCCB : 200 AMps ,4P,25 KA Busbar Capacity : 300 AMps mounted on DMC/ porcelain insulator support with RYB indicator Outgoing : one MCB/MCCB mounted chanel slotted 500 mm long
M & L for fabrication of bus bar chamber of size not less than 600 x 600 x450 mm suitable for 415 volts 3 phase 4 wire system , outdoor type, double door, with pedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and out going cable including grouting of panel board 60 cm above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge Incoming MCCB : 160 AMps ,4P,16 KA Busbar Capacity : 200 AMps mounted on DMC/ porcelain insulator support with RYB indicator
Notes:- For Item No 24 to 29 1. The Panel Should be approved by CPRI. 2. The rates Quoted shall include for excavatio & earth work, Plinth protection around the panel apprx 75cm and excavation & earthwork for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm X 60 cm X 6 mm buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5 m below the normal ground level connected to GI earth strip 32 X 6 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, protected by GI pipe light grade 40mm bore all as shown on electrical plate No 3 of SSR Part-I connected to earth test point electrode, PCC pit with RCC cover, funnel with wire mesh, watering pipe 20mm dia protection pipe etc and testing on completion complete all as specified and directed. Note No 1 :- The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B-1 cover 50 mm thick reinforced with 8 mm dia TMT bar @ 150 mm c/c both ways, funnel with watering pipe 20 mm dia medium grade, GI protection pipe light grade 40 mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (Notes) under sub-heading earthing, specified on Serial Page No 389 of SSR Part –I. Note No 2 :- Earthing strip and GI protection pipe beyond 7.5 m will be measured and paid separately if required (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself.
Supply and fix in replacement New generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07, with luminaries 100 watt, with inbuilt surge protection 10 KV including 50 mm dia size of GI Bracket of length 1.2 Mtr, with Clamp, Nut, Bolt and washer, connection with 1.5 sqmm 3 run copper wire from junction box to streeght light and 4 sqmm 2 core aluminium service cable pvc insulated 2.5 RM per fitting where over head line existing for connection of street light to over head conductor complete all as specified and directed. Make : Havells cat part no ENDURAOMNIPLUSSL120WLED757SASYTOPC or equivalent as approved by GE.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm X 60 cm X 6 mm buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5 m below the normal ground level connected to GI earth strip 25 x4 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, protected by GI pipe light grade 40mm bore all as shown on electrical plate No 3 of SSR Part-I connected to earth test point electrode, PCC pit with RCC cover, funnel with wire mesh, watering pipe 20mm dia protection pipe etc and testing on completion complete all as specified and directed. Note No 1 :- The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B-1 cover 50 mm thick reinforced with 8 mm dia TMT bar @ 150 mm c/c both ways, funnel with watering pipe 20 mm dia medium grade, GI protection pipe light grade 40 mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (Notes) under sub-heading earthing, specified on Serial Page No 389 of SSR Part –I. Note No 2 :- Earthing strip and GI protection pipe beyond 7.5 m will be measured and paid separately if required (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself.
Dismantling carefully the existing LT overhead line ACSR conductor with cross arm of any size from its position by necessary disconnecting of conductor and removing complete all as specified and as directed
Dismantling stay assembly complete all as specified and directed
Dismantling of unserviceable existing cross arms made from channels, angles and unserviceable FI clamps, nuts, bolts etc from OH line and removing complete all as specified and as directed
S &F PCC Cable route Indicator with suitable reinforcement of size 50 x 10 x 10 cm with letter inscribed on both side as "MES LT CABLE " of specified front side not less than 30 mm as directed and complete using PCC 1: 2:4 B1 using 20 mm graded stone aggregate and including painting using cement based paint to the satisfaction of engr in charge
Supply, erecting and fixing in replacement of true vertical position of steel tubular swaged pole, 9 mtr long complete with cast iron base plate, finial taper plug, bolt, nuts and screws as specified and of type 410 SP-31, conforming to relevant IS, including one primer coat of d oxide and two coats of aluminium paint and two coats of bituminous paint inside and outside of botton portion including writing of pole nos (Yellow circle and Number in black) and providing 3 Nos of radium with width 50 mm size band / strap with Red, Yellow, Green colour 300 mm apart from plinth block around the pole etc complete as all as specified and directed in Engr-in- Charge.
M & L for painting of Street light poles of any type (with hydrolic vehicle / ladder) including cross arms, channel, flat iron clamps etc 9/11 mtr long in two coats of aluminium paint and one coat of red oxide as primer including writing of pole nos (Yellow circle and Number in black) and providing 3 Nos of radium with width 50 mm size band / strap with Red, Yellow, Green colour 300 mm apart from plinth block around the pole etc complete as all as specified and directed in Engr-in- Charge. Note:- Hydrolic Vehicle / Ladder for painting is responsibility of contractor and rate of Hydrolic vehicle and ladder deemed to be included in quoted rate.
M & L for painting of coping of pole including preparation of surface and one coat of primer and two coat of Apex (off white colour) complete all as specified and directed by engr in charge
S.k ENTERPRISES (BID ID -3486076)
J B ELECTRICALS (BID ID -3486677)
Maruti Abhiyantriki (BID ID -3486488)
Ms. S.K. ASSOCIATES (BID ID -3486077)
AZAD SERVICES (BID ID -3486081)
KAMINS CARE (BID ID -3486398)
BHAVIN INFRA (BID ID -3486847)
M/s AG PATHAN (BID ID -3486168)
m/s shivam tools and equipment (BID ID -3484830)
M/s Swaroop Enterprises (BID ID -3486494)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
TenderDOCUS8160.pdf
Tender Documents • 0.73 MB
PS_8160.pdf
Additional Documents • 0.67 MB
BOQ_827517.xls
BOQ • 0.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .