Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹9.7 L+₹98,222.80 (11.2%)Rejected-Finance GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL 246155 | LANSDOWNE | PAURI GARHWAL | UTTARAKHAND | 246155 | L2 | Rejected-Finance Being not lowest |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
15 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne, Disst- Pauri Garhwal Pin-246155
REPAIR/MAINT AND REPLACEMENT OF VARIOUS TYPES OF STARTERS, PANELS AND CONNECTED WORKS AT LANSDOWNE
2022_MES_500815_2
8703/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I Lansdowne
Class E Cat b i
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹17,000
11 Mar 2022
1 Feb 2022
17 Feb 2022
1 Feb 2022
15 Feb 2022
3 Feb 2022
60 days
Amount
M&L for Design, supply, Fabrication, Installation, testing and Commissioning factory made, LT panel board, Indoor type, totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 hz, AC supply system, fully compartmentalised, made out of 2.00mm thick CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work / support made out of suitable size of angle iron / flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size (minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : - (a) Busbar chamber : Electrically grade shrouded aluminium bus bar of capacity 600 Amps for each phase and 300 Amps for neutral and current density 0.8A/Sqmm , including interconnection of all switch gears, fixed on DMC insulators and provision of extension. The wk to be carried out at Jharapani Pump House.
OUTGOING:- with Four compartment each comparment which consist the following : Compartment 1: (i) MCCB 200 amps, 415Volts, 3 pole 50 Hz, 16/25 KA with Motor Duty type, Ics = 100%Icu(1 sec) complete with spreader and EROM all as specified and directed Cat : CM92171OONOOG - 01 Nos .(ii) Contactor 95 Amps cat part No CS94136 L&T E&A or equivalent ABB / Siemens - 02 Nos (Main and delta) (iii) Contactor 70 Amps cat part No CS97076 L&T E&A or equivalent ABB / Siemens - 01 Nos (Star) (iv) MPR 300 42A-69A 01 Nos Cat part No MPR305BE320 Compartment 2: (i) MCCB 160 amps, 415Volts, 3 pole 50 Hz, 16/25 KA with Motor Duty type, Ics = 100%Icu(1 sec) complete with spreader and EROM all as specified and directed - 01 Nos cat part No CM90345OOMO .(ii) Contactor 95 Amps cat part No CS94136 L&T E&A or equivalent ABB / Siemens - 02 Nos (Main and delta) (iii) Contactor 70 Amps cat part No CS97076 L&T E&A or equivalent ABB / Siemens - 01 Nos (Star) (iv) MPR 300 42A-69A 01 Nos Cat part No MPR305BE320 Compartment 3: (i) MCCB 125 amps, 415Volts, 3 pole 50 Hz, 16/25 KA with Motor Duty type, Ics = 100%Icu(1 sec) complete with spreader and EROM all as specified and directed - 01 Nos cat part No CM90345OOLO L&T E&A - 01 Nos .(ii) Contactor 95 Amps cat part No CS94136 of L&T E&A or equivalent ABB / Siemens - 02 Nos (Main and delta) (iii) Contactor 50 Amps cat part No CS97075 of L&T E&A or equivalent ABB / Siemens - 01 Nos (Star)(iv) MPR 300 28A-46.5A 01 Nos Cat part No MPR304BE160 Compartment 4: (i) MCCB 125 amps, 415Volts, 3 pole 50 Hz, 16/25 KA with Motor Duty type, Ics = 100%Icu(1 sec) complete with spreader and EROM all as specified and directed - 01 Nos cat part No CM90345OOLO L&T E&A - 01 Nos .(ii) Contactor 95 Amps cat part No CS94136 of L&T E&A or equivalent ABB / Siemens - 02 Nos (Main and delta) (iii) Contactor 50 Amps cat part No CS97075 of L&T E&A or equivalent ABB / Siemens - 01 Nos (Star)(iv) MPR 300 28A-46.5A 01 Nos Cat part No MPR304BE160
EACH COMPARTMENTS CONSIST OF FOLLOWING ACCESSORIES: Motor protection relay type MPR300 of L&T E&A or equivalent in MINILEC / ABB - 01 No (iv) Phase failure relay with under and over voltage settings (type/ model L&T GIC MD71B9 or ALV D2 of minilec or equivalent in Siemens/ABB - 01 No , (v) Star delta timer of make L&T /ABB - 01 Nos , (vi) Green push button with NO -01 No make AIRON or equivalent in L&T /Siemens , (vii ) Red Push button with NC - 01 No make AIRON or equivalent in L&T /Siemens (Viii ) ON Red indicaiton lamp - 01 No make AIRON or equivalent in L&T /Siemens (ix) OFF Green Indication Lamp - 01 No make AIRON or equivalent in L&T /siemens , (x ) Terminals 125 Amps bus bar type -06 Nos , (xi ) MCB DP 6 amps 10 KA - 01 No (xii ) CT of ratio 250 /5 amps 5VA Class 1.0 .-03 Nos Make L&T / AE ,Including necessary connection with pvc insulated stranded copper conductor cable of suitable size. Make:- (a) LED indicator / Push button -ASS / VAA/L&T/siemens (b) LT Panels : ABB / Schneider / Universal switchgear control / Tenco systems and switch gears Pvt Ltd Indore. (c) ACB/MCCB/MCB : L&T/ABB/SCHNEIDER / SIEMENS.
Notes for Item No 1 :- 1. Panel manufacturers should have in house powder coating plant with minimum 8 tank pretreatment of MS sheet facilities, dust free spray paint booth.(8 tanks pretreatment process includes: degreasing/water rinsing/de-dusting/water rinsing/activation/phosphating water rinsing/passivation). 2. Thickness of powder coating shall not be less than 80 microns and test certificate for powder coating shall be furnished along with LT panel 3. The panel manufacturer should have following certification: (i) CPRI certification degree of protection IP-54 ( should have IEC:61439-1-2 & IEC:60529 tests) (ii) CPRI certification short circuit with stand strength should be 50 KA RMS for 1 sec with initial peak of 105 KA (iii) CPRI certification rated current for short circuit not less than 5000A 4. All the electricals switch gear like MCCBs, MCB should be of same make 5. Drawing of panel board should be got approved from GE before fabrication. 6. Panel board should be fully compartmentalized in accordance to form 4 b of IEC 61439-1-2.
S&F for U-PVC pipe of size 75 mm(bore) of SCH-40 including all pipe line fittings like elbow, socket plug hose clips adaptors cutting through walls floors and making good or laying in trenches complete all as specified and directed by Engg-in-Charge.
Supply, laying & testing of PVC insulated unarmoured and unsheathed three core copper conductor flexible cable of 35 Sqmm complete all as specified and directed
Supply, laying & testing of PVC insulated unarmoured and unsheathed three core copper conductor flexible cable of 25 Sqmm complete all as specified and directed
Disconnecting the unserviceable under ground cable, taking out the same and supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads of size 240 sqmm 3.5 core complete all as specifed and directed. Note;- The earth work, GI pipe shall be measured and paid sepretely under appropriate item of Sch A
Excavation in trenches in hard/dense soil n.exc 1.5 m wide and n.exc 1.5 m in depth for poles,laying under ground electric cable and GI tubing (where provided for protection of cables), stay and getting out, trimming the sides, forming bottom surface to required level in any type of soil complete all specified and directed by Engg-in-Charge.
Returning , filling in, any type of soil including spreading, leveling, watering and well ramming in layers n.exc 250mm thick, in any tupe of soil complete all as specified and directed by Engg-in-Charge.
Removing excavated material (surplus soil) to a distance not exceeding 50m and depositing where directed at a level n.exc 1.5 m above the starting point, complete all as specified and directed by Engg-in-Charge.
M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed by Engg-in-Charge. Note:- Punned (consolidated ) thicness of sand will be measured and paid.
M&L for well brunt bricks sub class 'B' designation in old size as cable protection laid flat width wise complete all as specified and directed.
M&L for 100 mm bore GI tube light grade laid under road/culvert/drain fixed to pole wall with help of flat iron clamps etcfor cable protection and making good surface of road with PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) complete all as specified & directed by Engg-in-Charge.
S&F in repair electronic star delta timer 3-30 seconds type ST100,160-500Volts, 50Hz complete all as specified and directed. Make-L&T/ Secure/Schneider
S&F in repair Contactor 95 Amps cat part No LC1E95M7 of schneider and equivalent in ABB/L&T complete all as specified and directed.
S&F in repair Power contractor 3pole type MNX-140, 140Amp complete all as specified and directed.Make-L&T Cat part No-CS94139 or equivalent in ABB/Schneider
S & F in repair auxiliary contact block side mounting wwith 1 No+ 1 NC commplete all as speciffied and directed. Make: L&T/Schneidder/ABB
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exc 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed by Engg-in-Charge.
M&L for rendering 10 mm thick cement plaster 1:6 on external surfaces of brick wall/concrete surface complete all as specified and directed by Engg-in-Charge.
S & F in replacement motor protection relay D2MPR of Minilec or equivalent in L&T and Schneider commplete all as speciffied and directed.
S&F in replacement Phase failure relay with under and over voltage settings (type/ model ALV D2 of minilec or equivalent in L&T /Schneider complete all as specified and directed.
M&L for preparation after complete removal of existing treatment from old plastered surface of wall with latest technology and wash with bleaching powder & applying two coats of acrylic emulsion paints (Apex Ultima/ waethercoat all guard ) over a coat of suitable primer complete all as specified and directed. Make:- Asian/ Burger/ Nerolac Note: Site of work is water supply installation which are not approachable by road.
M&L for fabrication work of MS channel of any section for fixing of pump motor set along with Nuts Bolts washers of required size complete all as specified and directed.
M & L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in mass concrete/coping complete all as specified and directed.
M & L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in mass concrete/foundation complete all as specified and directed.
Demolition of old PCC of Pump motor set, taking down pump set from base frame and fixing on new PCC platform on MS channel complete all as specified and directe. Note: Rate of new PCC and MS channel will be measured separately against respective item of Sch 'A'. Rate quoted will be inclusive of welding of suction and delievery pipe on pump flange.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required but 25x4mm galvanised iron strip incl taking down old strip complete all as specifed and directed by Engg-in-Charge.
Dismantling old unserviceable out door /indoor type switch gear panel alongwith associated bus bar, metering , fuses , MCCBs (U/S) switches, starters etc indication lamps including disconnecting power cables all as specified and as directed by Engg-in-Charge. Note : The complete dismantled items shall be handed over to MES dept main stores including transportation .
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. (earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 25x4 mm GI strip as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 40 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI strip more than 7.5 mtrs will be measured and paid seperately under relevant items.
PIONEER REFRIGERATION AND ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .