Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹29.3 LAccepted-AOC | 1 | Accepted-AOC lowest bidder | |
| 2 | Rejected-Technical | - | Rejected-Technical second lowest bid |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
21 Feb 2024, 3:00 pmClosed
Executive Engineer PWD Electrical Division Kannur
PWD Electrical Division Kannur
DEPOSIT-Govt. Medical College, Kannur - Air Conditioning of Cath Lab and HDS store Supply and Installation of HVAC system in Cath Lab and HDS store-Electrical AC Work
2024_PWD_655976_2
PWD/BLDG/TR/14774/2023_13_1
Open Tender
Electrical Works
Item Rate
90 days
Kannur
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
14 Nov 2024
16 Feb 2024
23 Feb 2024
16 Feb 2024
21 Feb 2024
16 Feb 2024
Amount
SITC of AC in Cath Lab and HDS store
OD102519/2023-2024:SITC of 5.5 TR inverter type R 410 A copper refrigerant coil outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel, panels and coated with baked enamel finish. The unit should be completely factory wired tested with all necessary controls. Outdoor units shall be compact air cooled type. All the compressors of the outdoor units must be hermetically sealed BLDC inverter scroll/ Twin rotary type. OEM should use there on make compressors in ODU which is to be supplied. System cop shall not be less than 3.35 at AHRI condition and suitable to operate at heat load proportional to indoor temperature requirement. Aluminium fins of condenser coil shall have anti corrosive epoxy resin coating along with hydrophilic coating. including supply and providing vibration pad etc complete as required ( Brand- Blue star/Misthubishi, /Carrier/Hittachi)
OD102503/2023-2024:SITC of 11 TR (4400CFM) 6 Rd/ 125mm double skinned Thermal break air handling unit as per specification complete with minimum 40mm thick panel with 0.8 mm GI on each side, 40KG/M3 PUF, with fan section with plug fans , suitable rated TEFC motor suitable for 415 V , 50 Hz Ac supply with necessary drive arrangements with VFD, Coil section with 6 row deep DX cooling coil, filter section with 10 Micron pre filters and 5 Micron fine filters along with nitrile rubber insulated Aluminium drain pan, drain connection mixing box section with FA and RA damper and all, UV lamp, necessary thermostatic expansion valves ,Supply, installation and commissioning of AHU kit control panel box with coded remote control with all control wiring AHU starter , over load relay, necessary contactors, timers, MCBs, indication lamps, connectors, digital temperature switch with temperature indication etc. other standard accessories including necessary vibration isolation arrangements etc complete as required (Brand- VTS / Zeco / Edge-Tech / Fin power/Systemair)
OD105877/2023-2024:SITC of 11 TR capacity ductable air cooled air conditioning unit with scroll compressor, copper condenser coil, High efficiency power full condenser unit with all standard fittings, safety devices, like HP/LP cut out, single phase preventer, overload relays. All microprocessor control with digital display and cordless remote , R-410 or equivalent gas incuding supply and providing vibration pads . Supply, fitting , testing and commissioning of 11 TR capacity FCU suitable for Drug store etc as required - Make Blue star/Carrier / Mistubishi/ Hittachi.
OD102360/2023-2024:Supply and providing following size hard drawn copper pipe for the extending the pipe between out door and in door unit including the pipe using rubberised form sleeve 10mm thick, brazing, leak testing etc. (for extending length of pipe beyond starndard length supplied with the unit, size suitable for 5.5 TR condenser and 11 TR AHU , 22 gauge hard drawn copper pipe insulated using 10 mm thick rubber nitrite insulation - liquid line 9.52 mm or suitable
OD102359/2023-2024:Supply and providing following size hard drawn copper pipe for the extending the pipe between out door and in door unit including the pipe using rubberised form sleeve 10mm thick, brazing, leak testing etc. (for extending length of pipe beyond standard length supplied with the unit, suitable for 5.5 TR condender and 11 TR AHU, 22 gauge hard drawn copper pipe insulated using 10 mm thick rubber nitrite insulation / suction pipe 19.05 mm or suitable.
OD105878/2023-2024:Supply and providing following size hard drawn copper pipe for the extending the pipe between out door and in door unit including the pipe using rubberised form sleeve 9mm thick, brazing, leak testing etc. (for extending length of pipe beyond standard length supplied with the unit, size 11/8 inch or suitable for 11 TR ,22 gauge hard drawn copper pipe insulated using 9 mm thick rubber nitrite insulation (Suction line)
OD105880/2023-2024:Supply and providing following size hard drawn copper pipe for the extending the pipe between out door and in door unit including the pipe using rubberised form sleeve 9 mm thick, brazing, leak testing etc. (for extending length of pipe beyond starndard length supplied with the unit, size 5/8 inch or suitable for 11 TR, 22 gauge hard drawn copper pipe insulated using 9 mm thick rubber nitrite insulation (discharge line)
OD102362/2023-2024:Supply and fabrication conveyance and installation of angle iron frame work for mounting outdoor unit and indoor unit using suitable size MS angles/flats cut and welded to shape fixing the same on floor or wall/parapet as required including painting with two coats of enamel paint over a coat of zinc chromite primer
OD103208/2023-2024:Supply ,installation , balancing and commissioning of of Aluminium sheet metal rectangular/ round ducting with neoprene gasket work for theatre complete with all fittings such as TEE, Bends, Turning vanes including, Suspension and supporting arrangement as required and necessary joints sealed . Aluminium 20 Gauge.
16.12.2.2:Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
16.12.1.3:Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006 Thickness 1.00 mm sheet
OD102366/2023-2024:Supply and installation of canvas set
16.15:Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
16.16.a:Supplying and Fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
OD102368/2023-2024:Supply and filling of R-410 gas charging
OD102363/2023-2024:Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (class "O") insulation on existing duct after applying two coats of cold setting adhesive (CPRX compound). The joints shall sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. Nitrile rubber insulation - 13 mm
OD102365/2023-2024:Supplying and fixing of following thickness mat finish closed cell Nitrile rubber (class "O") aquastic insulation inner side of the existing duct after applying two coats of cold setting adhesive (CPRX compound). Nitrile rubber aquastic insulation - 13 mm
OD103254/2023-2024:Supply, installation and commissioning of HEPA filter and Plenum box suitable for 4400 CFM with minimum particle efficiency of 99.97% down to 0.3 Microns , with plenum box supporting panel made of Aluminium sheet etc as required.
OD103270/2023-2024:Supply, installation testing and commissioning of 9KW electric strip heaters for controlling humidity complete with fixing arrangements, thermostats and safety thermostate including all power control wiring.
OD103271/2023-2024:Supply, installation, testing and commissioning of fresh air arrangements with VCD and cowl & bird screen and grille and 20 micron synthetic filter etc as required.
OD103295/2023-2024:SITC of extract Air arrangements with louvers, back draft Dampers and VCD and cowl and bird screen etc as required.
OD103351/2023-2024:Supply, installation, testing and commissioning of extruded Aluminium volume control dampers complete with flanges channels and control levers suitable for duct mounting
OD102369/2023-2024:Supply and fixing 32 mm UPVC drain water pipe line with necessary, supports, saddles, clamps, hangers, and fittings such as bends, tees etc and shall the fixed on the wall with suitable size saddle and screw complete in surface/recess including cutting wall and making good the damages as required.
90.6.4.2:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 2 Run
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
90.6.5.21:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 6.00 sq mm
OD103359/2023-2024:Dismantling the existing false ceiling existing in Cath lab / HDS store for the fixing the units / ducts and reassembling the same as required.
90.11.1.19:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
OD106036/2023-2024:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required. - 4P enclosure for independent mounting of MCB.
2.2.14:Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 Amp, 36 KA
2.25:Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.
OD106124/2023-2024:S&F Spredar/terminal adapter kit extended terminal for3/ 4 pole MCCB rating upto 250A (8 Pcs)
OD106033/2023-2024:Supplying and fixing 40 A to 63 A, TP MCB (C curve), 10 kA breaking capacity 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1.14.10:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
OD106047/2023-2024:Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required. 12x3mm brass nut and bolt etc. as required.
PONNU HYLINE
Bidder Name
PONNU HYLINE
Bharath Aircon
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1020990.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .