Loading…
Loading…
Tender Value
₹95.7 L
EMD Value
₹1.9 L
Closing Date
8 Sept 2026, 3:00 pm6d left
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
WA
16 conditions · 5 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees. N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of Indian Railways Standard General Conditions of Contract, GCC - April 2022, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Similar work shall mean by "Electrification/Rewiring of Station/Building/Project/Yard etc."
4 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The intended tenderer shall get digital signature certificate and get registered with Rly. For new vendors, the procedure is described in Rly. Website www.ireps.gov.in. The tender shall be submitted in Rly website www.ireps.gov.in not later than stipulated time and date of tender closing. After closing of the tenders at stipulated time the tenders shall be opened on the same date. In case the date of tender opening happens to be holiday, the tender shall be opened on the next working day in the same manner.
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society /Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall attached all documents pertains to status of firm i.e Partnership deed, Power of attorney, Resolution of Board of Director's etc. as applicable as per GCC.
Electrical work in connection with elimination of LC No. 13,15,21,22 on Mahesana - Viramgam Section, LC No. 4, 19, 38, 45 on Palanpur - Samakhiyali Section, 05 Nos. LC on Viramgam - Samakhiali & Mahesana - Patan Section, LC No. 12,19,24,42,13 on Viramgam - Mahesana - Bhildi - Palanpur, 06 Nos. LC on Mahesana - Patan - Bhiladi Section and LC No. 27 at 31/7-8 & 35 at 37/9 - 38/0 by providing road under bridges with covered approaches.
EL-ADI-G-T-29-2026-27~WR
EL-ADI-G-T-29-2026-27
Open
Works - General
12 Months
Ahmadabad, Gujarat
₹0
₹1.9 L
10 Aug 2026
10 Aug 2026
25 Aug 2026
246 items across 6 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 14,50,792 | ||
| — | Item Breakup for | details. | — | ||
| Supply of materials and provide open/surface wiring of light/fan point up to 6 meter with three numbers 1.5 mm Sq. multi strand, FRLS PVC insulated "ISI Marked" copper wires for phase, neutral & earth in "ISI Marked" medium class P.V.C. conduit pipe of white/cream. The rates of point wiring include providing PVC switchboard with 6 Amps. modular switch with flush mounted cover plate and heavy duty PVC round/square blocks, 3-point ceiling rose, angular base lamp holder etc. as per technical specification shown in Para (A) of Annexure. Note: Beyond 6 meter wiring additional payment will be done through NS item. | — | — | — | 1,02,720 | |
| — | Item Breakup for | details. | — | ||
| Supply and laying in wall & ceiling in open manner of ISI marked medium class rigid 25 mm. dia. PVC conduit pipe with all accessories as per technical specification shown in Para (A) of Annexure. | — | — | — | 7,600 | |
| — | Item Breakup for | details. | — | ||
| Supply of materials and wiring of main/sub main in open manner with 2.5 mm Sq. size multistrand FRLS PVC insulated ISI marked copper wire for phase, neutral & one number 1.5 Sq. mm copper wire for earth continuity with PVC casing capping as per technical specification shown in Para (A) of Annexure. | — | — | — | 73,200 | |
| — | Item Breakup for | details. | — | ||
| Supply, installation, testing and commissioning of 60 watt LED flood light IP 66 compete with all accessories. The contractor shall provide the mounting arrangement for fittings as required at site and as per technical specification shown in Para (B) of Annexure. | — | — | — | 69,320 | |
| — | Item Breakup for | details. | — | ||
| Supply, installation, testing & commissioning of junction box as per technical specification shown in Para (C) of Annexure. | — | — | — | 17,820 | |
| — | Item Breakup for | details. | — | ||
| Supply, installation, testing and commissioning of 40 watt weather proof LED light fitting IP 65 complete with all accessories. The contractor shall provide the mounting arrangement for fittings as required at site and as per technical specification shown in Para (B) of Annexure. | — | — | — | 5,08,800 | |
| — | Item Breakup for | details. | — | ||
| Digging of cable trench 450 x 1000 mm & refilling as per technical specification shown in Para (D) of Annexure. | — | — | — | 39,200 | |
| — | Item Breakup for | details. | — | ||
| Transportation, laying, installation, terminating, testing and commissioning of LT/HT cable of sizes 4 core 10 Sq. mm to 4 core 300 Sq. mm in existing trench, pipe or on structure as per technical specification shown in Para (E) of Annexure. | — | — | — | 15,200 | |
| — | Item Breakup for | details. | — | ||
| Supply and laying of half round RCC pipe 100 mm. ID & 1 mtr. length as per technical specification shown in Para (F) of Annexure. | — | — | — | 25,600 | |
| — | Item Breakup for | details. | — | ||
| Laying of cables in cable tray/air/ on wall/pole with suitable clamp/ saddles as per technical specification shown in Para (G) of Annexure. | — | — | — | 8,400 | |
| — | Item Breakup for | details. | — | ||
| Supply, installation, testing and commissioning of 100 mm width X 50 mm depth GI hot dip perforated cable tray complete with all accessories as per technical specification shown in Para (H) of Annexure. | — | — | — | 68,600 | |
| — | Item Breakup for | details. | — | ||
| Supply, installation, testing and commissioning of single phase astronomical digital timer for street lighting control as per technical specifications shown in Para (I) of Annexure. | — | — | — | 81,480 | |
| — | Item Breakup for | details. | — | ||
| Supply, installation, testing and commissioning of 3 pole 25A power contactor as per technical specifications shown in Para (J) of Annexure. | — | — | — | 33,580 | |
| — | Item Breakup for | details. | — | ||
| Supply, installation, testing and commissioning of size inside 280 mm x 180 mm x 60 mm Junction box as per technical specifications shown in Para (K) of Annexure. | — | — | — | 17,220 | |
| — | Item Breakup for | details. | — | ||
| Supply, installation, testing and commissioning of 20 Amp. MCB SP as per technical specifications shown in Para (L) of Annexure. | — | — | — | 5,720 | |
| — | Item Breakup for | details. | — | ||
| Supply, installation, testing and commissioning of maintenance free earthing as per technical specification shown in Para (M) of Annexure. | — | — | — | 1,43,400 | |
| — | Item Breakup for | details. | — | ||
| Supply and provide 25 X 3 mm GI strip as per technical specification shown in Para (N) of Annexure. | — | — | — | 14,200 | |
| — | Item Breakup for | details. | — | ||
| Digging of cable trench by pushing method under track/road and laying, testing and commissioning of cable as per technical specification shown in Para (O) of Annexure. | — | — | — | 71,880 | |
| — | Item Breakup for | details. | — | ||
| Supply, installation, testing and commissioning of HDPE pipe 110 mm nominal dia. as per IS 4984-1995 and as per technical specification shown in Para (O) of Annexure. | — | — | — | 72,840 | |
| — | Item Breakup for | details. | — | ||
| Supply, installation, testing and commissioning of DB panel having 1 No. 20 Amp. MCB DP as incoming and 4 Nos. 6 Amp 30 mA sensitivity RCBO DP as outgoing with complete accessories as per technical specification shown in Para (P) of Annexure. | — | — | — | 74,012 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
T_29_doc_6estimatesclubbedLCandextensionpf.pdf
ATTACHMENT
GCCwithACS11.pdf
ATTACHMENT
BGFormate.pdf
ATTACHMENT
E BG policy
ATTACHMENT
e-BGPolicyinEPCGCCPMSPSSAGCPGMSDated16.06.2026.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].