Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 100 KUNJRA MAHAL SADAR BAZAR PO P S BARRACKPORE DIST 24 PARGANAS N KOLKATA 700120 | KOLKATA | 24 PARGANAS N | WEST BENGAL | 700120 | Admitted-Finance |
| 2 | Admitted-Finance 32 LOOTERY MOHAL ORDERLY BAZAR PO BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700 120 W B | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | Admitted-Finance |
| 3 | Admitted-Finance GOALAPARA MONIRAMPUR PO BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700 120 WB | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | Admitted-Finance |
| 4 | Admitted-Finance 296 N 183 2 JOGEN GANGULY STREET MONIRAMPUR BARRACKPORE DIST 24 PARGANAS N KOLKATA 700 120 W B | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹95,000
Closing Date
25 Dec 2021, 6:00 pmClosed
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
Special Repairs to Building No- A-78 at 6 Wg AF Stn Barrackpore under GE (AF) Barrackpore
2021_MES_483023_2
8328/BKP/AF OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE AF Barrackpore
Pl refer tender documents
5 documents required · 5 mandatory
₹500
GE AF Barrackpore
₹95,000
Yes
27 Dec 2021
17 Dec 2021
27 Dec 2021
17 Dec 2021
25 Dec 2021
17 Dec 2021
Amount
Demolition of brick work built in cement mortar.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc 6 mtr mean radius, built in CM 1:6.
Dismantling of plain or corrugated steel sheeting any guage thickness including nainital or similar pattern roof covering all as specified.
S&F for Plain galvanised mild steel sheetings 1.00 mm thick in ridges,hips, valley gutter drip and straight flashings (length and girth as fixed) with grade of zinc coating 275
Material and labour for pre-painted, galvalium alunminium zinc coating GI based corrugated steel sheet, 0.50mm thick of colour and profile as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self taping screws. It minimum metallick coating mass is AZ 150 (150 g/sqm) with super durable polyster Exterior paint system, tatal 25 um DFT on topside and 10um DFT on reverse side complying with AS/NZS 2728- Type 4 or IS 15965-class 3, complete all as specified and directed by Engr in Charge. Make-(Tata Bluescope/Sazena Marine Tech or Equivalent Make)
Material and labour for pre-painted, galvalium alunminium zinc coating GI based Plain steel sheet, 0.50mm thick of colour and profile as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws. It minium metallick coating mass is AZ 150 (150 g/sqm) with super durable polyster Exterior paint system, total 25 um DFT on topside and 10um DFT on reverse side complying with AS/NZS 2728-Type 4 or IS 15965-class 3, complete all as specified and directed by Engr In Charge. Make-(Tata Bluescope/Saxena Marine Tech or Equivalent Make)
Dismantling timber scantlings 40 sq. cm and over in section, in any framed work. position
S&F roof trusses (framed) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam tee, angle, channel or flat sections) including clits etc conforming to Fe-410-0 or Fe-310-0.
S&F rolled mild steel section of joist, channel, angle or tee section fixed independently, without connecting plates etc conforming to Fe-410-0 or Fe-310-0.
M&L for RCC 1:2:4, type B-1 (using 20 mm graded aggregates) as in slab supported on walls, beams(Gable beam) and columns in floors,roofs landings balconies canopies deck slab and in shelves and the like complete all
S&F for mild steel bars 10mm dia and over deformed or twisted bars TMT, cut to length, bent to shape as required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. Fe-410
M&L for form work to side and soffit of concrete in slab, beam, lintel etc in rough finished flat surfaces of concrete.
M&L for cutting holes in to or through brick walls buillt in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lim mortrar n exc 150 sq cm
Dismantling wall and ceiling boards (fibre,pulp,insulation, etc) or insulation boards/slabs/blankets any thickness, including cover fillet
S/F Anodised aluminium snap grid frame work of size 605x605mm for false ceiling including all fittings all as specified.
Material and labour for Exposed metal frame ceiling with calcium silicate board of calcareous material reinforced with cellulose fibre for fixing in 600mmx600 mm grid and 6 mm thick (Frame work for ceiling shall be measured and paid seprately) complete all as specified and directed.
Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls etc including raking out joints, hacking for key, scrubbing down with water etc.
M&L for Rendering 10 mm thick cement plaster in CM 1:6 on brick or concrete surface on wall (internal surfaces) including finished even and smooth without using extra cement.
M&L for Rendering 20 mm thick cement plaster in two coats( 12mm+8mm) on external surfaces of brick work in CM 1:4 and second coat to be applied with WPC including fair finishing (WPC will be measured and paid separately).
Supply only WPC
Dismantling wrought iron or mild steel work of any description not otherwise provided for.
M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of red oxide.
M&L for two coats of acrylic base exterior paint over a coat of primer on newly plaster surfaces including preparing of serfaces
M&L for applying two coats of white wash on walls including preparation of newly plstered surface.all as specified and directed.
M&L for one coats of acrylic base exterior paint on old plaster surfaces .
Dismantling of 100mm bore cast iron or reinforced concrete drain pipes, jointed in cement morter and taking out of trenches if required.
S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed in wall.
S&F 110mm bore PVC (SWR) bend
Taking down and refixing of existing lightening conductor on the roof existed from repair of roof complete all as specified and directed by Engg In charge
M&L but Except sheeting(any thickness) Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as inroof covering/cladding to wall, fixed withself tapping screws as specified
Ditto as per item No 11 but 5 mm dia and over upto and including 10mm dia in stirrups,spacers and binders.
S&F 160mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed in wall
S&F 160mm bore PVC (SWR) bend
M&L for 4mm thick Asbestos cement plain building boards fixed to timber framework with screws complete all as specified and as directed by Engr In charge
M&L for plain fillets 2 nd class hard wood exc 6 & n exc 13 sq cm square rectangular or triangular in section wrought sawn secured with nails or brads complete all as specified and directed
M&L for Preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coats of Synthetic enamel paint complete all as specified and as directed
M&L for preparation of old steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying one coats of synthetic enamel paint .
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for including removal of debris in low laying area of defence land as specified and directed by Engr-in-charge.
M&L for Providing PCC 1:3:6 type C-2 (using 40 mm agg.) 75 mm thick in Sub base of floor complete all as specified and directed
M&L sand filling in floor or in foundation laid in layers not exc. 15 cm thick, spread, levelled and rammed including watering
M&L for 80 mm thick machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 (M-40 grade) complete all as specified and as directed.
M & L for providing plain cement concrete type B-0, 1:2:4, (using 12.5mm graded stone aggregate), as in copings, bed blocks including necessary form work as required complete all as specified and directed.
T/D chowkat .exe 1.50 sqm and nexe 4 sqm without taking off shutter each
T/D chowkat n.exe 1.50 sqm without taking off shutters each
S&F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe-410 W- Gde- E-250 quality - A
S&F for Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face,with wood free EPS supplying & fixing in frame at site as per specification & drawing
S&F steel window with side hung shutters inclding projecting type hinges with steel handle , and steel peg stay, complete with glazing bars, dovetailed or welded
M&L PCC(1:3:6) type C1 as in bed blocks for hold fast including necesssary formwork complete.
S & F mild steel flat iron as in hold fast clamps articles conforming to FE 410-O or FE 310-O
S&F MS Butt hing medium weight cold rolled 100mm size.
S&F 200 mm long mild steel, barrel tower bolt of extruded section.
S&F Mild steel pressed handles, oval type, stove enamelled black 150mm long
S&F 300 mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed.
S&F fo Mild steel bolts. purpose made exc 12 n exc 20mm dia. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30cm long ®
M&L for cutting holes for bolts,pipes joist Air flues ventilators cast iron boxes etc and making good to existing work in brick work walls built in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concreteExc 150 sq cm but n exc 400 sq cm
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, pendants, regulators socket outlers, light fittings etc removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls floors etc.
Taking down unserviceable existing sub main wiring with copper/aluminium coductor stranded cable upto and including 2 run of 4 sqmm /2run of 6 sqmm single core including earth wire from existing conduit or wooden battens including takin g out unserviceable wooden gutties etc, matching with the existing surfaces complete all as specified and as directed.
M&L for Surface Point wiring with 1.5 Sqmm (Nominal area) PVC insulated, unsheathed, multistranded FRLS copper conductor cable (1100Volts grade) drawn in and including PVC casing caping with all fittings and accessories for one light point controlled by one switch alongwith PVC insulated cable with standed FRLS copper conductor (green in colour) of size 1.5 sqmm and connected to earth dolly including of 1.2mm thick MS sunk terminal box suitably fixed flushed to wall and 3mm thick plastic laminated sheet top cover fixed with brass screws and cup washers complete.
All as per item No 58 here-in-before but for one fan point controlled by one switch complete
M&L for submain wiring comprising single core 2 Runs of 4 sqmm nominal cross sectional area FRLS multimultistranded copper conductor cable PVC insulated unsheathed 1100 volts grade drawing in and including appropriate dia in PVC cashing caping and its fittings complete including provision of 1x4 sqmm nominal cross sectional area multimultistranded copper conducter cable PVC insulated unsheathed 1100 volts grade as earth wire complete ). Note - Extra length of cables/wire required for connection to MCB's/DB's shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly).
M&L switch piano flush type single pole, one way, 5 Amps, 240 V complete
S&F ceiling rose surface type with 3 terminals complete
S&F flush type electronic fan regulator with 4 step type, 120 W, AC 240 Volts, 50 Hz complete
Supply and fixing indoor LED recessed mounted fitting in diffused type 50 watt 2ftx2ft complete with all accessories 3 core copper wire for connection, making good the disturbed ceiling and remove the UNSV fitting and all as specified and directed.
S&F MCB, DB, SPN, 12 ways DOUBLE DOOR, IP-43, with rated bus bars, earth bar, neutral links complete incl blanking plates as required & fixed flush to wall and making good the distrubed surfaces complete all as specified and as directed including dismentling taking down unserviceable one Make- L&T Cat No- DBSPN012DD or equivalent.
S&F MCB SPN 40 Amps 240V, 50 Hz breaking capacity 10 ka "C" series including dismentling taking down unserviceable one. Make- L&T Cat No BB20400C
S&F MCB SP, 10 KA, 230V, C-curve, 6-32 amps incl dismantling taking down unsv one. Make-L&T Cat No - BB10320C
M&L for applying one coats of white wash on walls on old plastered surface complete all as specified and as directed.
M/S A. J. CONSTRUCTION
ZENITH CONSTRUCTION
SARKAR AND COM
Oenix and associates
JADAV CONSTRUCTION
Das and Brothers
M/S. TAPAS ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .