Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.5 LAccepted-AOC TAILOR MARKET MAIN BAZAAR MANDI ADAMPUR 125052 | HISAR | HARYANA | 125052 | L1 | Accepted-AOC LOA | |
| 2 | L2₹25.9 L+₹1.3 L (5.50%)Rejected-Finance PLOT NO 927 SECTOR 47 GURGAON 2022R6406 | GURGAON | L2 | Rejected-Finance Highest | |
| 3 | L3₹27.0 L+₹2.5 L (10.1%)Rejected-Finance 209 210 AGGARWAL TOWER PLOT NO 2 SECTOR 5 ROHINI NORTH WEST DELHI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | L3 | Rejected-Finance Highest |
| Sl No | Description | Qty | Unit | Hytek Turnkey Projects Pvt. Ltd. L3 | Prime Computers L1 | Kenbrook Automation Private Limited L2 |
|---|---|---|---|---|---|---|
| 1.00 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] | 450 | Metre | 38 ₹17,100 | 31 ₹13,950 Lowest | 35 ₹15,750 |
| 2.00 | SITC of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of 4 loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control modules when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 2 Serial Ports. The pane\l shall have a built in power SITC, battery charger maintenance free battery capable of running for a minimum 24 hours operation complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS.Make:Honeywell/G.S.T/Siemens. | 1 | Each | 4,25,000 ₹4,25,000 | 3,92,800 ₹3,92,800 Lowest | 4,15,255 ₹4,15,255 |
| 3.00 | SITC of addressable Photoelectric detector including base, auto addressing features as required. Detectors should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elemnets in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance wiht EFSG agreement EFSG/F/97/005. EMC safety for detector shall be 50 V/m. shall be EN54/VDS/UL certification. (Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices) Makes: G.S.T / Siemens /Honeywell Moreley.. | 244 | Each | 3,050 ₹7,44,200 | 2,955 ₹7,21,020 Lowest | 3,015 ₹7,35,660 |
| 4.00 | SITC of addressable Heat Detector wht fixed and rate of raise feature including mounting base with LED etc complete as required. Each detector should have 2 as per NFPA 72 style 7 wiring requirement (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to eletrmagnetic effects in accordance with EFSG agreement EFSG/F/97/005. Detector should monitor electromagnetic interfarence and report to the panel-current and average values, EMC safety for detector shall be 50 V/m. shall be EN54/VDS/U: certification. (Detectors without inbuilt isoaltors may be considered with an additional isolator module per detector. Makes: G.S.T / Siemens /Honeywell Moreley. | 8 | Each | 3,090 ₹24,720 | 2,860 ₹22,880 Lowest | 3,100 ₹24,800 |
| 5.00 | SITC of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect Makes: G.S.T / Siemens /Honeywell Moreley | 26 | Each | 4,820 ₹1,25,320 | 3,750 ₹97,500 Lowest | 4,110 ₹1,06,860 |
| 6.00 | SITC of Addressable Loop powered sounder with strobe/flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect Makes: G.S.T / Siemens /Honeywell Moreley. | 26 | Each | 7,250 ₹1,88,500 | 6,800 ₹1,76,800 | 6,254 ₹1,62,604 Lowest |
| 7.00 | SITC of minimum 1000 Mtr. Range Siren generator provided at the roof of the building with separate power suppl, relay etc.. Make: National/Kheraj | 1 | Each | 10,230 ₹10,230 | 9,600 ₹9,600 Lowest | 11,690 ₹11,690 |
| 8.00 | SITC of Glow Type Exit Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class - I material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener Managed Type including cost of labour and material required to complete the job in all respect. Make Omex/ Savmax/PES. | 32 | Each | 2,430 ₹77,760 | 1,950 ₹62,400 Lowest | 2,220 ₹71,040 |
| 9.00 | SITC of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Makes: G.S.T / Siemens/Honeywell Moreley | 2 | Each | 6,250 ₹12,500 | 5,250 ₹10,500 Lowest | 7,500 ₹15,000 |
| 10.00 | SITC of Analog Addressable type Active Repeater Fire Alarm Panel with Backlit LCD display, having controlls for reset, mute, accept, silence alarms and self test conforming to BS5839 standards with all labour and materials required to complete the job in all respect up to the entire satisfaction fo engineer-in-charge of work.Makes: G.S.T / Siemens/Honeywell Moreley. | 3 | Each | 94,300 ₹2,82,900 | 87,000 ₹2,61,000 | 86,990 ₹2,60,970 Lowest |
Tender Value
₹25.2 L
EMD Value
₹50,420
Closing Date
25 Jun 2025, 5:00 pmClosed
NAVEEN RATHEE
ED - Ambala
Construction of office bldg. of Industries and Commerce Department. Haryana in Plot No. 01 and 02, Sec-1, MDC Panchkula. (Pdg. Fire Alarm System Only).
2025_HRY_453328_1
20258019B916 1616 4313 ACD9 667DBF236422663BAR
Open Tender
Civil Works
Works
150 days
Ambala Cantt
Construction of office bldg. of Industries and Commerce Department. Haryana in Plot No. 01 and 02, Sec-1, MDC Panchkula. (Pdg. Fire Alarm System Only).
2 documents required · 2 mandatory
₹5,000
₹50,420
Yes
30 Sept 2025
18 Jun 2025
26 Jun 2025
19 Jun 2025
25 Jun 2025
19 Jun 2025
Amount
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
SITC of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of 4 loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control modules when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 2 Serial Ports. The pane\l shall have a built in power SITC, battery charger maintenance free battery capable of running for a minimum 24 hours operation complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS.Make:Honeywell/G.S.T/Siemens.
SITC of addressable Photoelectric detector including base, auto addressing features as required. Detectors should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elemnets in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance wiht EFSG agreement EFSG/F/97/005. EMC safety for detector shall be 50 V/m. shall be EN54/VDS/UL certification. (Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices) Makes: G.S.T / Siemens /Honeywell Moreley..
SITC of addressable Heat Detector wht fixed and rate of raise feature including mounting base with LED etc complete as required. Each detector should have 2 as per NFPA 72 style 7 wiring requirement (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to eletrmagnetic effects in accordance with EFSG agreement EFSG/F/97/005. Detector should monitor electromagnetic interfarence and report to the panel-current and average values, EMC safety for detector shall be 50 V/m. shall be EN54/VDS/U: certification. (Detectors without inbuilt isoaltors may be considered with an additional isolator module per detector. Makes: G.S.T / Siemens /Honeywell Moreley.
SITC of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect Makes: G.S.T / Siemens /Honeywell Moreley
SITC of Addressable Loop powered sounder with strobe/flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect Makes: G.S.T / Siemens /Honeywell Moreley.
SITC of minimum 1000 Mtr. Range Siren generator provided at the roof of the building with separate power suppl, relay etc.. Make: National/Kheraj
SITC of Glow Type Exit Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class - I material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener Managed Type including cost of labour and material required to complete the job in all respect. Make Omex/ Savmax/PES.
SITC of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Makes: G.S.T / Siemens/Honeywell Moreley
SITC of Analog Addressable type Active Repeater Fire Alarm Panel with Backlit LCD display, having controlls for reset, mute, accept, silence alarms and self test conforming to BS5839 standards with all labour and materials required to complete the job in all respect up to the entire satisfaction fo engineer-in-charge of work.Makes: G.S.T / Siemens/Honeywell Moreley.
SITC of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be considered separately for payment). Makes: G.S.T / Siemens /Honeywell Moreley.
SITC of 2 KVA UPS with 30 min backup online with Suitables 3 No. 26 Ah,12V batteries with necessary MS stand for batteries. Make Microtek / Luminous / Elnova.
SITC of Wiring for Fire Alarm system with the following sizes single core 1.5 sq.mm of FRLS insulated copper conductor Double core 1100 volts grade cables in existing surface/recessed M.S. conduit etc. as complete as required. Make Finolex/Grandly/Polycab/Plaza
SITC of ABC Dry power type fire extinguishers of 5 kg. capacity duly hang on wall with necessary hook complete in all respect, Make: Safex/Minimax/ Ceasefire
SITC of Co2 type fire extinguishers of 4 Kg capacity duly hang on wall with necessary hook complete in all respect, Make: Safex/Minimax/ Ceasefire
Kenbrook Automation Private Limited (BID ID -1285022)
Hytek Turnkey Projects Pvt. Ltd. (BID ID -1284942)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .