| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹5.1 LAccepted-AOC UPPER SARTHI VIHAR AJABPUR KALAN PO NEHRUGRAM HARIDWAR ROAD DEHRADUN 248001 UK | DEHRADUN | UTTARAKHAND | 248001 | ₹5.1 L Quoted ₹5.4 L | 1st | Accepted-AOC Contract awarded to M/s Garhwal Enterprises please see uploaded AOC for details. |
| 2 | 2nd₹7.6 L+₹2.2 L (40.6%)Rejected-Finance GANDHI CHOWK LANSDOWNE 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | ₹7.6 L+₹2.2 L (40.6%) | 2nd | Rejected-Finance L2 |
| 3 | 3rd₹8.6 L+₹3.2 L (59.6%)Rejected-Finance | ₹8.6 L+₹3.2 L (59.6%) | 3rd | Rejected-Finance L3 |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
13 Jan 2024, 6:00 pmClosed
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne, Disst- Pauri Garhwal Pin-246155
REPAIR / MAINTENANCE OF GEYSERS, EXHAUST FANS AND ALLIED WORKS AT LANSDOWNE UNDER AGE (I) LANSDOWNE.
2023_MES_632219_1
8856/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I Lansdowne
All as per NIT and Tender Documents
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹16,000
Yes
9 Feb 2024
11 Dec 2023
20 Jan 2024
12 Dec 2023
13 Jan 2024
26 Dec 2023
Amount
Dismantling and taking down U/S point wiring of any type (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
M&L for point wiring with PVC insulated FRLS unsheathed single core cable of multistranded copper conductor of size 2.5 sqmm as phase & neutral drawn in and including PVC conduit(HMS), duly concealed to wall/floor of suitable size with all fitting and accessories laid on wall/ceiling alongwith 1.5 sqmm stranded PVC insulated unsheathed copper conductor(Green in color) as earth wire and connected to common earth dolly incl making good to surface with CM(1:4) plaster and paint to match the surface complete all as specified and directed for one 5/15 Amps socket on independent board complete all as specified and as directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates ii) If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
S&F Modular Socket Outlet 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
M & L Modular Switch, 16 A, 1 Way, 1 Module complete all as specified and directed.
Taking down the unserviceable water storage heater of 25/50ltrs capacity, any type and make, refixing the same after cleaning the scaling deposited in the inner container and water pipe complete all as specified and directed. Note - repair of unserviceable bolts incl regrouting shall be deemed to be included in the rate quoted by tenderer. However GI fittings shall be measured and paid for separately as supply only.
Supply and fix in repair of Non return valve 15mm dia made of bronze suitable for existing size of geysers ISI marked heavy duty complete all as specified and directed.
Supply and fix in repair of Water heating element of 1.5 KW capacity for geysers in Triangular/ Cup type / Round type / As per existing shape and size complete all as specified and directed.
Supply and fix in repair of Water heating element of 2 KW capacity for geysers in Triangular/ Cup type / Round type /As per existing shape and size complete all as specified and directed.
Supply and fix in repair of thermostat for geysers in Triangular/ Cup type / Round type /As per existing shape and size complete all as specified and directed.
Supply and fix in repair of indicator bulb (Red & Green) for geysers of approved make complete all as specified and directed.
Supply and fix in repair of spring loaded Air-release safety valve 15mm dia made of brass for geysers as per existing shape and size of approved make complete all as specified and directed.
Supply and fix in repair of inner container made of copper for 25 ltrs capacity (Copper Tank for geysers) of approved make as per existing size / guage complete all as specified and directed.
Supply and fix in repair of inner container made of copper for 50 ltrs capacity (Copper Tank geysers) of approved make as per existing size / guage complete all as specified and directed.
Supply and fix in repair of bottom cover in two pieces made of GI sheet for geysers duly painted in required/existing size and shape suitable for 25/50 ltrs capacity water storage heater complete all as specified and directed.
Supply and fix in repair of fancy type chromium plated / brass stop cock CP with capston head, heavy duty of 15mm bore, fixed to iron pipe or brass ferrule fixed in repairs complete all as specified and directed.
Supply and fix in repair of brass assembly heavy duty suitable for 25 ltrs geysers of any make and size complete all as specified and directed.
Supply and fix in repair of brass assembly heavy duty suitable for 50 ltrs Geyser of any make and size complete all as specified and directed.
Supply and fix in repair of Outer container made of GI sheet duly painted with enamel paint of approved colour, capacity 25 ltrs geysers fixed in repairs complete all as specified and directed.
Supply and fix in repair of Outer container made of GI sheet duly painted with enamel paint of approved colour, capacity 50 ltrs geysers fixed in repairs complete all as specified and directed.
Supply and fix in repair of PVC connection heavy duty 450mm long suitable for 15mm bore pipe with 2 Nos of brass nut and washer for geysers complete all as specified and directed.
Supply and fix in repair of Hex Nipple 15mm bore heavy duty for geysers complete all as specified and directed.
S&F in repair of medium grade GI water tubing size of 15 mm dia conforming to IS-1239 Part-I-1979 including all fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc ,fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F in repair of gun metal Globe or Gate valve with iron wheel head screwed both ends for fixing GI tubing.of 15mm dia complete all as specified and directed.
S&F in repair of bib tap, cast-copper alloy with crutch handle screwed down, screwed for inner pipe of 15 mm dia complete all as specified and directed.
Dismantling of exhaust fan 450/380 mm sweep of any make/ model, opening for cutting, taking out existing unserviceable winding wire, rewinding with super enamel copper wire of existing gauge, including varnishing and insulating material with washer, split pin, checknut, hanging clutch, condenser clamp, assembling,with required flexible wire 0.5 mtr and testing complete all as specified and directed.
All as per Srl item 25.00 above but for exhaust fan 350/300 mm sweep. complete all as specified and directed..
All as per Srl item No 25.00 above but for exhaust fan 250/200 mm sweep. complete all as specified and directed.
Taking down exhaust fans 450/380/350/300/250/200 mm sweep, removing and cleaning of dust properly, oiling and greasing of bearing with and including repair of washer, new split pin & any other minor spare parts such as new screw, checknut, pin etc and refixing in position, connecting, testing complete all as specified and directed.
S&F in repair of condensor 4 MFD suitable for exhaust fan complete all as specified and directed.
S&F in repair of condenser 3.15 MFD exhaust fan complete all as specified and directed.
Spray painting of Exhaust fans of any size including fan blades, after scrapping and cleaning old painted surfaces, with enamel paint including writing of MES Number complete all as specified and directed.
S&F in repair of plug top 3 pin, 15 Amp, 230 volts complete all as specified and directed.
S&F in repair of Metal Clad Socket15/20 Amp, 230 volts suitable for MCB DB plug & socket SPN 20 Amps complete all as specified and directed.
S&F in repair of Metal Clad Plug Top 15/20 Amp, 230 volts suitable for MCB DB plug & socket SPN 20 Amps complete all as specified and directed.
S&F Exhaust fan made of sturdy Engineering plastic complete with louvers shutter,AC single phase 230/240 Volt ,50HZ,RPM 1200,Copper winding of 300 mm sweep complete including making hole and making good the disturbed sufaces of wall all complete all as specified and directed. Note:- Old Exhaust fan deposit at MES Store Yard.
S&F in repair Wall Bracket light fitting (Bldg Security light) 20W housing made out of die cast aluminium alloy with tougned glass , IP 65 protection having clamp for mounting on building wall working on 240V AC 50 Hz , 20 Watts consisting of reflective lens, wired with appropriate driver PF>0.95 having over voltage protection up to 400 volts, surge protection level 7 - 10 KV, thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and LED lumen efficiency >120 lumen Per watt, including fixed on wall with 02 Nos MS Clamps made of 40x6 mm FI and bracket made of 40 mm dia light grade GI Pipe bend to shape, not less than 1.2 m long including connecting with 02 single core PVC insulated copper conductor cable 1100 v grade size 1.5 sqmm complete all as specified and directed. Note : Connection to luminaire shall be done in suitable PVC connector within the bracket/luminaire end and are inclusive in above.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size PCC 1:2:4 Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
Supply and fix Water heater storage type water heater (Geyser) capacity 25 litres BEE 5 star rated including grouting the nut bolts - 04 Nos, PVC Connection Pipe - 02 Nos, Chromium plated Stop Cock 15mm - 02 Nos, bib tap- 01 Nos and necesssary GI pipe etc all complete all as specified and directed. Note:- Old Geyser deposit at MES Store Yard.
Panwar Electrical
RAMSONS DEVELOPERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .