GE 969 EWS
GE 969 EWS C/O 56 APO
REPAIR TO JOINERY, PLASTERING, FLOORING AND SANITARY FITTINGS AT OFFR MESS AND OFFR LIVING AT PATTAN AND ZONE II AT BARAMULLA UNDER GE 969 EWS
2022_MES_552336_1
CANO 969/WS- /2022-23
Open Tender
Civil Works
Item Rate
180 days
BARAMULLA AND PATTAN
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE 969 EWS
₹38,800
Yes
29 Oct 2022
16 Sept 2022
17 Oct 2022
16 Sept 2022
15 Oct 2022
1 Oct 2022
Amount
Demolition of Brickwork or stone/boulder masonry built in CM or cement lime mortar including all quions arches, pillars etc but excluding ashlar facings dressed stonework & precast concrete articles.Complete all as specified and as directed.
Taking down cement plaster or screed bedding layer of any description from concrete slab/terrace surfaces etc including racking out joints hacking for key, scrubbing down with water.
M&L precast cement concrete block fly ash block masonary with solid blocks exc 10cm in width and setting in cement mortar 1:6, type B-1 1:2:4 using (20mm graded crushed stone aggregate) complete all as specified and as directed.
M&L 20 mm thick cement plaster (1:6) on fair faces of brick work or concrete surfaces.Complete all as specified and as directed.
M&L Reinforced cement concrete (nominal mix) type B-1 1:2:4 (20mm graded crushed stone aggregate) as in beams, cantilievers, bressummers. lintels over 1.5m span. Complete all as specified and as directed.
M&L Mild steel TMT bars 10mm dia & Over,cut to length, bent to shape required including cranking bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and as directed.
M&L Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers & binders, cut to length,bent to shape required, binding with & including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and as directed.
Formwork to sides of concrete foundations, footings,bases of columns, raft & raft beams, sides & soffits of foundation & plinth beams, and similar work, verticle or to batter Fair finished surfaces of concrete flat complete all as specified and directed.
Dismantling timber Scantling 40 sqcm and over in section in any position.
M&L 2nd class soft wood timber fixed in scantling.
Dismantling of plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating Gl based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed self tapping screws complete all as specified and directed.
S&F Galvanised corrugated mild steel sheeting with two corrugation side lap, with L-type or J-type or cranked hook bolts & washers, in roofs, walls etc with grade of zinc coating 120 gm of 0.63mm thick complete all as specified and directed.
S&F Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip & straight flashings (length & girth as fixed) with grade of zinc coating 120 gm if 0.63mm thick complete all as specified and as directed.
Demolition of Cement concrete (un renforced) in ground floor and paving not exc cm thickness (below or above ground level)
M&L for brick work with sub class 'B' bricks (old sizes) straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 complete all as specified and as directed.
M&L for Rendering 15mm thick plastering on brick work or concrete surface in CM (1:6) and rendering is to be finished even and smooth w/o using extra cement complete all as specified and as directed.
S&F in repair 2nd class softwood in scantling clean swan timber framed and fixed to the position to replace old and decay timber.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.
S&F Sheet glass thickness 3.00mm, ordinary quality and glazing with oil putty in square exceed 0.5 sqm in each pane complete all as specified and as directed.
M&L Preparation new plastered or undecorated surfaces of walls and applying two coat of cement base paint, white or tint. Complete all as specified and as directed.
M&L preparation new plastered or undecorated surfaces of walls and applying three coat of white wash. Complete all as specified and as directed.
M&L for 100 mm thick Cement concrete 1:4:8 type D-2, (using 40mm graded crushed stone aggregrate) as in sub base complete all as specified and as directed.
M&L Sand filling under floors or in foundations including watering and consolidation.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness with grey cement and pigment, M-35 Grade Complete all as specified and as directed.
S&F Vitreous China Wall Hung coupled closet including cistern with lid dual flush fitting with PVC seat cover size not less than 665x360x765 mm (white) including fixing bolt complete all as specified and as directed.
S&F CP health flucet hand held triggered nozzle and delivers a spray of water with pipe.
S&F CP jet spray with flexible tube 1.5 mtr long complete all as specified and as directed.
S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled & countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete & screwing etc wind ties for roof including securing bolts; posts & struts in fencing including cutting tops for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and as directed.
S&F welded steel wire fabric not exc 4 kg/sqm welded or fitted to angle iron frame work. Complete all as specified and as directed.
M&L PCC in foundations, filling and mass-concrete type C-2 (1:3:6) (using 40 mm graded stone aggregate) complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu.m, getting our, returning, filling in & ramming earth/broken rubble mixed with earth around, in layers n. exc 25cm, watering & removing surplus soil to a distance n exc. 50m & making good surface in soft/loose soil.
Applying two coats of synthetic enamel paint on steel & iron surfaces of any description not otherwise described over 10 cm width or girth including preparation of new surface & applying one coat of red oxide, zinc chrome complete all as specified and as directed.
Note:- Schedule of credit Rs 1,08,800.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
LONE CONSTRUCTION COMPANY
Javeed And Co
Alishan Builders
M/S ESS EMM ENTERPRISES
M/S HAJI MOHD ASHRAF SUMJI
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .