The Additional Secretary
Kannur Municipal Corporation. Civil Station Post, Kannur - 670 002
Annual Plan - Project No. S 1876/26 - Supply and Installation of UPS at Dialysis Centre, Attadappa under Buy back Scheme
2026_UAD_854951_1
3224764-2026
Open Tender
Equipments
Supply
30 days
Attadappa
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,030
Yes
₹7,800
Yes
16 Jun 2026
9 Jun 2026
16 Jun 2026
9 Jun 2026
16 Jun 2026
9 Jun 2026
9 Jun 2026 - 16 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing and Commissioning of 20.0KVA/240 Volt True On-line IGBT UPS ( 3Phase-1Phase ) with Built-in Isolation transformer model with following configuration. Input : (i) Input Voltage : 360-480 V (ii) Freequency : 50 Hz+/- 5% (iii) Input Power Factor : >0.9. Output : (i) Voltage : 220/230V +/- 1%. (ii) Regulation +/- 1%. (iii) Frequency : 50 Hz (iv) Frequency Regulation : +/- 0.05 Hz (v) Power Factor : >0.8 to unity (vi) Transient Response : <8%(10%~90%(Linear Load)) (vii) Voltage Harmonic : <3% (Linear Load) (viii)Over Load Capacity (%) : 100 to 110% : 5minutes , 110 to 120% : 2minutes (ix) Crest Factor : 3:1. Battery : 20 Nos. 12 Volt/ 100 Ah Tubular Battery, C10 Series (Preferred Make : Exide/Amaron) including Rack , Connectors & Accessories. Display : LED Indications : UPS ON# Battery Low/High# Out Put Voltage Low/High-R,Y,B# Over Load – R/Y/B# Fault# Charger ON# Input Voltage Low/High – R,Y,B. LCD Indications: Input Voltage & Frequency – R, Y, B# Output Voltage & Frequency- R, Y, B# Battery Voltage# Load Level# Working Status# Fault Status. Warranty 2 year on-site warranty for UPS and 3 year replacement warranty for Battery, including buy back price of old 20.0 KVA UPS with with 20 Nos. 12V/100 Ah Tubular Battery | 1 | Set | 1.25 | ₹1.25 |
| 2 | Supply, Installation, Testing and Commissioning of 10.0KVA/192 Volt True On-line IGBT UPS ( 3Phase-1Phase ) with Built-in Isolation transformer model with following configuration. Input : (i) Input Voltage : 360-480 V (ii) Freequency : 50 Hz+/- 5% (iii) Input Power Factor : >0.9. Output : (i) Voltage : 220/230V +/- 1%. (ii) Regulation +/- 1%. (iii) Frequency : 50 Hz (iv) Frequency Regulation : +/- 0.05 Hz (v) Power Factor : >0.8 to unity (vi) Transient Response : <8%(10%~90%(Linear Load)) (vii) Voltage Harmonic : <3% (Linear Load) (viii)Over Load Capacity (%) : 100 to 110% : 5minutes , 110 to 120% : 2minutes (ix) Crest Factor : 3:1. Battery : 16 Nos. 12 Volt/ 100 Ah Tubular Battery, C10 Series (Preferred Make : Exide/Amaron) including Rack , Connectors & Accessories. Display : LED indications : UPS ON# Battery Low/High# Out Put Voltage Low/High-R,Y,B# Over Load – R/Y/B# Fault# Charger ON# Input Voltage Low/High – R,Y,B. LCD indications: Input Voltage & Frequency – R, Y, B# Output Voltage & Frequency- R, Y, B# Battery Voltage# Load Level# Working Status# Fault Status. Warranty 2 year on-site warranty for UPS and 3 year replacement warranty for Battery , including buy back price of old 10.0KVA UPS with with 20 Nos. 12V/100 Ah Tubular Battery | 1 | Set | 1.25 | ₹1.25 |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.14 MB
Integrity.pdf
Tender Documents • 0.24 MB
BOQ_1444893.xls
BOQ • 0.27 MB
prelagt.pdf
Tender Documents • 0.19 MB
makemodel.pdf
Tender Documents • 0.02 MB
epayment.pdf
Tender Documents • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .