Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-AOC | L1 | Accepted-AOC Due to lowest accepted | |
| 2 | L2₹6.9 L+₹4,483.75 (0.65%)Rejected-Finance | L2 | Rejected-Finance Other then lowest | |
| 3 | L3₹9.1 L+₹2.2 L (31.8%)Rejected-Finance | L3 | Rejected-Finance Other then lowest |
Tender Value
₹10.4 L
EMD Value
₹20,742
Closing Date
29 Aug 2022, 6:00 pmClosed
Garrison Engineer Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge CG Complex Ludhiana-141001
SPECIAL REPAIR / RE-WIRING TO BLDG NO P-42 (GUN SHED) AND P-43 (RDR SHED) OF AD REGT AT DHOLEWAL AND CERTAIN SANCTIONED WORK AT DHOLEWAL UNDER GE LUDHIANA
2022_MES_542630_1
GE/LDH-32/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Dholewal Cantt Under GE Ludhiana
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹20,742
Yes
13 Sept 2022
2 Aug 2022
30 Aug 2022
2 Aug 2022
29 Aug 2022
16 Aug 2022
2 Aug 2022 - 15 Aug 2022
Amount
Taking down carefully the point wiring (light, Fan, socket or power) complete, (incl fittings such as switches, sockets any type, ceiling roses, pandents, light fittings, etc for taking credit( credit for above items should be made as per conditions separately) and making good disturbed surface of walls floors etc. all as specified.
M &L for point wiring complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through and including 20mm dia PVC rigid non metallic conduit with all accessories such as internal bend end caps and MS box thickness not less than 1.2 mm covered with 3 mm thick plastic laminated hard glassy surface sheet cover concealed in wall with screws & washers complete concealed in walls( suface on beam/ ceiling/roof etc) including provision of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor, all as specified and as directed for the following :-
One light/fan point controlled by one, one way switch
One switch socket outlet point 5 Amps on independent board
One 3 Pin socket outlet , 5 Amps on the same board with other switch
All as per item No. 2 described here-in-before but with copper conductor cable FR LS 2.5 Sqmm for one 3 pin socket outlet, 15 Amps and including provision of 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board.
Supply and fix for LED tube light fittings 1200 mm, 20W, 240V, 50Hz,rated input current- 0.070-0.110, rated input watt 20, oprating voltage range- 140-270, P.F- not less then 0.95, surge protection upto- 4Kv, IP20, THD shell be less then 10%, CCT- (k0)- 6500ANSI, higher energy saving decorative ultra slim square profile LED lighting fixture with extruded polycarbonate enviromental friendly, energy efficient complete all as specified and directed.
M & L for sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories concealed in wall (suface on beam/ ceiling/roof etc) etc all as specified and as directed .
Supply and fix for MCB DB TPN 4 ways ,Double door with 415 Amps rated bus bar 240Volt, Double door type all as specified
Supply and fix for MCB TPN 63 Amp,415 Volt C- curve, 50 Hz, breking capacity-10 kA. complete all as specified and directed.
Supply and fixing for factory made sheet metal enclosures SPN 8 way double door 240 v for DB,s suitable for having MCB flush with wall complete all as specified and directed.
Supply and fixing for MCB SPN 32 Amps 240 V, C- curve, 50 Hz, breking capacity-10 kA. complete all as specified and directed.
Supply and fixing for MCB SP 6-32 Amps240 V, C- curve, 50 Hz, breking capacity-10 kA . complete all as specified and directed
Supply and fix for ceiling rose surface type bakelite 65 x 50mm with three terminals complete all as specified and as directed
Supply and Fix for switch Piano,Flush type single pole , one way 5 Amp complete all as specified and as directed.
Supply and Fix for socket outlet 3 pin, 5 A flush Piano,Flush type complete all as specified and as directed.
Supply and Fix for switch Socket combenation 2 in 1 outlet 3 pin, 5 A flush type complete all as specified and as directed by Engr-in-charge
Supply and Fix for switch Socket combenation 2 in 1 outlet 3 pin, 16 A flush type complete all as specified and as directed.
M &L for earthing complete with galvanised steel earth plate electrode 60cm X 60 cm X 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level with the top edge of electrode not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4mm dia means of bolts, nuts,check nuts and washers of galvanised iron and GI lead protected with protection pipe of GI light grade 15mm dia upto 3mtr above ground level along poles fixed with two clamps of 25mm 3mm flat iron and connected to running earth wire at top of poles and watering pipe 20mm bore of GI medium grade all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing test point all as specified and direct and testing on completion including PCC 1:3:6 ) C-I cover and frame excavation and earth work etc complete all as specified in elect plate No 3 of SSR Part -I 2009 Note :- PCC Chamber shall be constructed at least 1.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner.
Taking down of XLPE cable any size complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core incl necessary glands where necessary complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm 4 core incl necessary glands where necessary complete all as specified and directed.
Excavation in trenches soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of pipes/cables etc getting out and bottom surface to required gradient complete all as directed & specified.
M & L for returning filling in including spreading leveling watering and well ramming in layers each not exceeding 25 cm thickness complete all as specified and as directed
M & L for removal of surplus spoil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed
Supplying, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cable for under ground cable complete all as specified & directed. i.e 18 cm punned down thick shall be considerd for mesurement)
M & L for old size sub class 'B' bricks,laid flat in trenches over the cable with length of brick perpendicular to the direction of the cable, adjacent/abutting each other complete all as specified.
Taking down of any size of building security light fittings complete all as specified and directed.
Supply and fixing for bldg security light fitting LED 45 W LED made up of pressure die cast aluminium housing with potted isolated driver and high power LED and indl lenses, oprating range- 90V to 340V AC. LED life -1 Lac burning hrs , fixture should with stand 320V upto 48 Hrs , auto cut off>320 V & restart ,440V sustain upto 8 Hrs, NABL acreddited LM 79 report, IP66 with high power LED lamp compete all as specified and directed. Make:- Havells/OSRAM/Philips /crompton/Bajaj
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2.of capacity 1.5 Ton all as specified and directed.
Supply and fix for voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 4 KVA all as specified and as directed by Engr-in-Charge.
Supply and fix for single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps 240 V as specified.
M & L for submain wiring of 2 run of 4.00 sq mm as phase (red/yellow/blue) and neutral (black) and one run of 4.00 sq mm as earth continuity wire green colour, FRLS PVC insulated copper conductor, single core cable in surface conduit / concealed / recessed as required as specified. Note: Three run cable shall be measured in one unit.
Supply and fix for exhaust fan steel body , heavy duty 300mm sweep with louvers, 1400 RPM and connecting up & including provision of copper and flexible 3 core of size 0.5 sqmm and PVC connector block complete all as specified and as directed.
Supply and fix refrigerator direct cooling single door, electric driven (single phase) with inverter technology,capacity of 200/215 ltrs, 5 star rated with mounitng stand complete all as specified and as directed.
M & L for sub main wiring complete with 2 runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories concealed in wall/Ceiling etc all as specified and as directed. Note:- Three run cable shall be measured in one unit.
Supply and fixing for factory made sheet metal enclosures SPN 4 way double door 240 v for DB,s suitable for having MCB flush with wall complete all as specified and directed.
M& L for earthing complete for LT Panels with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GI strip 32mm x 6mm and including GI pipe 50mm bore light grade as protection pipe (from top of earth plate up to the test point) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around including top and bottom and watering pipe 20mm bore of GI pipe medium grade with funnel and wire mesh, PCC chamber of size 300x300x300mm(top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregate of 25mm thick with 2 nos MS handles of 12mm dia including necessary excavation/ earth work in any type of soil and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .