Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹15.4 LAccepted-AOC 66 C O J R NAICKER ASWATHNAGAR SANJAYNAGAR P O BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L-1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L-2₹17.9 L+₹2.4 L (15.3%)Rejected-Finance | L-2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L-3₹18.7 L+₹3.2 L (20.8%)Rejected-Finance 160 PREM NAGAR BAREILLY | L-3 | Rejected-Finance Over all rates are higher than L-1. | |
| 4 | L-4₹18.9 L+₹3.4 L (22.0%)Rejected-Finance | L-4 | Rejected-Finance Over all rates are higher than L-1. | |
| 5 | L-5₹19.1 L+₹3.6 L (23.3%)Rejected-Finance | L-5 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
7 Jan 2021, 6:00 pmClosed
Garrison Engineer, Air Force, Bareilly
Garrison Engineer, Air Force, Bareilly, 243002
SPECIAL REPAIR TO INTERNAL WIRING AND ALLIED SERVICES, SPECIAL REPAIR TO ELECTRIC METERS, PROVISION OF ADDITIONAL SECURITY LIGHTS, PROVISION OF SERVO STABILIZER AND PROVISION OF CERTAIN MINOR WORKS UNDER AGE (AF) BHOWALI.
2020_MES_397184_2
8559 / E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bhowali
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer, Air Force
₹40,000
Yes
27 Jan 2021
24 Dec 2020
9 Jan 2021
24 Dec 2020
7 Jan 2021
26 Dec 2020
24 Dec 2020 - 26 Dec 2020
Amount
Taking down carefully aluminium / copper point wiring (light point, fan point, socket outlet point or power point) any type (batten, casing-N-caping, surface conduit or concealed conduit) complete with and including fittings and fixtures such as switches, ceiling rose, pendent, lamp holder, regulator, switch, socket outlet, shade conical etc. and making good disturbed surfaces of walls etc. as per existing finishes by plastering, repairs and distemper / white wash / colour wash etc. complete all as specified and directed.
M & L for point wiring for one light point, fan point, bell point, 5 Ampere socket outlet point on independent board, controlled by one, one way switch with 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable (FRLS) drawn into and including PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed with and including necessary chase cutting on brick / stone masonry walls and making good as per existing and sunk cast iron or 1.2 mm thick pressed steel terminal boxes for mounting fittings like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded copper conductor cable (FRLS) as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed.
All as per item No. 2.00 hereinbefore but wiring for one 3 / 5 pin 5 Ampere socket outlet point on the same board, controlled with other switches complete all as specified and directed.
All as per item No. 2.00 hereinbefore but wiring for one 3 / 6 pin 15 Ampere socket outlet point on independent board and wiring using with 2.50 sqmm size cables complete all as specified and directed.
S & F of 1100 volts grade heavy duty two single core 6.00 Sqmm size PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into and including PVC conduit medium grade not less than 25 mm dia including its all accessories & fittings, fixed concealed with and including chase cutting and making good the same as per existing specifications along with a continuous run of multi-stranded copper conductor of size 6.00 Sqmm PVC insulated (FRLS) (green colour) cable as earth wire with and including taking down old unserviceable one complete all as specified and directed. NOTE: - TWO SINGLE CORE CABLES ALONG WITH EARTH WIRE AND PVC CONDUIT SHALL BE MEASURED AS ONE UNIT LENGTH.
S & F of modular type socket outlet 6 Ampere, 2 and 3 Pin combination, 2 Modules complete all as specified and directed.
S & F of modular type switch 6 Ampere, one way, 1 Modules complete all as specified and directed.
S & F of modular type socket outlet 6 and 16 Ampere, 3 Pin for both rating (Total 6 Pins), 2 Modules complete all as specified and directed.
S & F of modular type switch 16 Ampere, one way, 1 Modules complete all as specified and directed.
S & F as in replacement environmental friendly, LED, ultra modern, energy saving, surface mounted, decorative oval shaped bulk head edge lite LED luminaire comprising high brightness LEDs of 10 watt capacity duly pre-fitted with all accessories complete all as specified and directed. MAKE- Havells, Philips, C&S.
S & F of white cover plate with frame, 3 Module suitable for modular type switches complete all as specified and directed.
S & F of metal flush box 3 Module complete all as specified and directed.
S & F of white cover plate with frame, 4 Module suitable for modular type switches complete all as specified and directed.
S & F of metal flush box 4 Module complete all as specified and directed.
S & F of white cover plate with frame, 6 Module suitable for modular type switches complete all as specified and directed.
S & F of metal flush box 6 Module complete all as specified and directed.
S & F of white cover plate with frame, 2 Module suitable for modular type switches complete all as specified and directed.
S & F of metal flush box 1 or 2 Module complete all as specified and directed.
S & F of white cover plate with frame, 1 Module suitable for modular type switches complete all as specified and directed.
Supply and fixing of single phase 'DING-DONG' electric call bell, AC 230 volts complete all as specified and directed.
S & F of modular type bell push 6 Ampere, one way, 1 Modules complete all as specified and directed.
S & F of ceiling rose surface bakelite, 65 X 50 mm, three terminals, PVC / polycarbonate insulated body complete all as specified and directed.
S & F of wall / surface mounted type LED batten light fitting 1 X 20 watt (4 feet long), as per Cat. Part No. LUMILINE BS20WLED 865SPCWH of Havells or BN021C LED20S PSU CDL GRBN021C LED20S PSU CW GR S2 (SmartBright) of Philips or LTDC01220WLED/WD (TARA-M/20W) of C&S complete with all accessories internally pre-wired and including making electric connection with flexible twin core 1.00 sqmm size stranded copper conductor cable from light fitting to ceiling rose with and including taking down old unserviceable one complete all as specified and directed.
S & F of lamp holder, PVC / polycarbonate type insulated body with back plate suitable for batten / angle fittings complete all as specified and directed.
S & F flush mounting factory made ETPN DB's, 4 way, IP-43 Protection, IK-09 with metal door, with 2 neutral bus bar, Earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing with provision for 4 pole MCB and SP/TP MCBs as outgoing with and including dismantling / taking down of old unserviceable one complete all as specified and directed. (Cat. Part No. 607715 of Legrand or Cat. Part No. A9XTND04 of SCHNEIDER or Cat. Part No. CSDBTPNHDD04 of C&S)
S & F of isolator, 04 pole, 63 Ampere breaking capacity 10 KA, 240 volts with and including taking down old unserviceable one complete all as specified and directed.
S & F of flush mounting factory made SPN DB's Double door, 8 way (Cat. Part No. 607711 of Legrand or Cat. Part No. A9HSND08 of SCHNEIDER or Cat. Part No. CSDBSPNDD08 of C&S), IP-43 Protection, IK-09 with metal door, with neutral bar, Earth bar and cables ties for cable management fully insulated bus bar with and including taking down old unserviceable one complete all as specified and directed.
S & F of isolator, douple pole, 32 Ampere breaking capacity 10 KA, 230 volts with and including taking down old unserviceable one complete all as specified and directed.
S & F of MCB single pole 240 volts, 6 to 32 Ampere 50 Hz, 10 KA, ‘C’ series with and including taking down old unserviceable one complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to galvanised earth lead 4 mm dia all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel TMT bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:2:4 type B-1, GI protection pipe light grade 15 mm bore including testing on completion of job complete all as specified and directed. NOTE: - ON TESTING AFTER COMPLETION OF JOB, IF DESIRED EARTH RESISTANCE (i.e. LESS THAN ONE OHM) IS NOT OBTAINED, THE EARTHING SHALL BE REDONE BY THE CONTRACTOR WITHOUT ANY EXTRA COST TO GOVT.
Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked, 25 Sqmm 3.5 core, LT cable (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing with and including taking down old unserviceable one complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation of pole, stay, cables and the like and getting out in any type of soil complete all as specified and directed.
M & L for laying of course sand free from sharp materials as in filling in trenches for cable protection, laid to a uniform thickness of 23 cm (15 cm under the cable and 8 cm over the cable) and gently punned down to 18 cm thickness as required complete all as specified and directed.
M & L for laying brick as in protection covers over cables using well brunt sub class 'B' old size bricks in trenches over sand cushioning complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
Taking down carefully old detoriated wooden meter board including all electric meters, DB / TP switch fuse units and all other connected accessories, disconnecting carefully all electric meters and keep in safe custody for depositing the same in MES store complete all as specified and directed. NOTE: - The damaged surfaces to be made good with plastering in cement mortar 1:6 and applying the wall finishes to match the existing finishes. Cost of these provisions shall deemed included in the unit rate of this item.
S & F of digital type, AC single phase static energy meter (KWH Meter) of accuracy class 1.0, 240 Volts, 50 Hz with Backlite LCD display of rating 5-30 Ampere (Measures and Displays KWH, V, Current I, KW, pf last month history of KWH, MD in KW) alongwith special features like TOD, temper logging, optical communication port desplay in absence of power with and including transparent type hinged cover complete all as specified and directed.
S & F of digital type, AC single phase static energy meter (KWH Meter) of accuracy class 1.0, 240 Volts, 50 Hz with Backlite LCD display of rating 10-60 Ampere (Measures and Displays KWH, V, Current I, KW, pf last month history of KWH, MD in KW) alongwith special features like TOD, temper logging, optical communication port desplay in absence of power with and including transparent type hinged cover complete all as specified and directed.
M & L for wiring with one single core 2.50 Sqmm size multi-stranded copper conductor cable as in connection wire from DB to Electric meter with and including taking down old unserviceable one complete all as specified and directed.
S & F of factory made metallic board of size 50 cm X 50 cm X 20 cm made out of 2 mm thick CRCA sheet front door openable in two halfs having suitable locking arrangement and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer on inside and outside surface of board with and including provision of 12 mm thick plywood duly insulated on inside surface of board of size 40 cm X 40 cm alongwith necessary fixing arrangement of metallic board on surface of wall with suitable size Anchor Bolts complete all as specified and directed. NOTE- Danger notice plate of suitable size showing 440 V, Skull and pair of bones shall also be provided and cost of the same shall deemed included in the unit rate of this item.
Supply and fixing of LED security light fitting complete with all accessories pre-wired as per Cat. Part No. ENDURACITYLINERNEOSL70WLED757PASYBOTG of Havells or Cat. Part No. BRP062 LED 68 CW SLC S1 PSU (SmartBright Street) of Philips or Cat. Part No. LR02-781-XXX-57-G2 (SKYLINE) of Wipro with and including necessary fixing arrangements as required to fix on electric pole and making electric connection with 2.50 sqmm size, 3 core PVC insulated twisted multi-stranded copper conductor cable of required length complete all as specified and directed.
Supply and fixing of single arm street light bracket made of 40 mm bore medium grade GI pipe at an angle upto 30 degree light grade not less than 0.65 metre long fixed on pole with help of 02 Nos. mild steel flat iron clamp of size 50 x 5 mm including necessary nut-bolts and washers etc. duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Supply and laying in ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked, weather proof flat twin core 6 Sqmm size PVC cable with stranded aluminium conductor cable including commissioning and testing complete all as specified and directed.
Supply and fixing of thermoplastic cable junction box of size 210 X 310 X 116 mm, protection class IP-65 suitable for cable entry with terminal, external mounting bracket with and including all necessary fittings required for junction box mounting on pole / wall for cable of size 16 to 50 sqmm complete all as specified and directed.
Supply, transporting, erecting in true vertical position, steel tubular swaged pole, type 410-SP-31, 9.00 metre long, complete with mild steel base plate, pole cap, finial taper plug, bolts, nuts, washers etc. including painting two coats of aluminium paint over a coat of red oxide primer including 3 Nos. of bands / straps painted with signal red and white colour (300 mm each) in alternate layer from plinth block, marking of pole number with black synthetic enamelled paint 5.00 cm height including one coat black bitumenous paint on steel surface embedded in concrete foundation complete all as specified and directed.
Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked, 16 Sqmm 4 core, LT cable (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing complete all as specified and directed.
M & L for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for providing plain cement concrete, type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for providing plain cement concrete, type B-2, 1:2:4 (using 40 mm graded stone aggregate) as in coping of pole and the like with and including necessary form work as required at site complete all as specified and directed.
Supply, installation, commissioning and testing of 100 KVA capacity servo controlled voltage stabilizer confirming to BIS-9815 (Part-1) (1994), three phase, 50 Hz, naturally oil cooled, indoor type, unbalanced type, copper wound, metalllic body duly powder coated with lifting hooks two Nos., with digital display type, relay free (microprocessor based) smooth and silent operation with and including 1st filling of transformer oil upto required level comprising of the following specifications and characterstics complete all as specified and directed: - (a) Input voltage range- 300 to 480 Volts, 3 Phase, 50 Hz. (b) Output voltage stabilized at- 380 Volts + 10%, 3 Phase, 50 Hz. (c) Operating frequency- 47 to 53 Hz. (d) Operating Temprature- 0 to 50 degree centigrade. (e) No. of Phases- 03. (f) Speed of correction- 8 to 6 volts per Second for single phase and 13 volts per second Phase to Phase. (g) Efficiency- Greater than 97%. (h) Type of voltage / load- Unbalanced 4 wire (j) Mode of operation- Fully automatic. (k) Displaying type- Digital voltmeter, digital ammeter, digital input frequency meter. (l) Protective- Over voltage, under voltage, over load, High / low voltage cut off, single phase prevntor and phase reversal protection with by pass arrangement switch 4 Pole of suitable capacity, spike suppressor, alarm system. (m) MCCB- INPUT, OUTPUT MCCBs of suitable capacity as per KVA rating. NOTE: - Design, drawings, Technical specifications shall be approved by the Garrison Engineer.
M & L for new earthing comprising of copper earth plate electrode 600 mm X 600 mm X 3.15 mm thick buried directly in ground preferably in vertical position, (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to copper earth strip of size 20 X 3 mm by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate in alternate layers minimum 150 mm (compacted thickness) in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover of size 450 mm X 450 mm in cement concrete 1:2:4, type B-1, duly reinforced with 8 mm dia mild steel TMT bars @ 150 mm both ways center to center with suitable lifting handle made of 10 mm dia mild steel round bars to lift the cover, earth pit of PCC 1:3:6 type C-1, GI protection pipe light grade 40 mm bore including testing on completion of job complete all as specified and directed. NOTE: - ON TESTING AFTER COMPLETION OF JOB, IF DESIRED EARTH RESISTANCE (i.e. LESS THAN ONE OHM) IS NOT OBTAINED, THE EARTHING SHALL BE REDONE BY THE CONTRACTOR WITHOUT ANY EXTRA COST TO GOVT.
Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked, 95 Sqmm 3.5 core, LT cable (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing complete all as specified and directed.
Supply and fixing of switch disconnector fuse unit (Panel mounted cubical type) three pole and neutral AC, 100 Ampere, 50 Hz, 415 Volts (With bolted type fuse) complete all as specified and directed. MAKE- Havells, Legrand, L&T.
Supply and fixing of ON LOAD type change over switch 415 Volts, 4 pole, 100 Ampere duly enclosed in sheet metal enclosure complete all as specified and directed.
Supply, installation, commissioning and testing of metal top deep freezer single phase 240 volts, 50 Hz of capacity 150 Litres, temprature range < -26 degree celcius to < 8 degree celcius having 5 star rating with minimum 5 years compressor warranty and anti radient cabinate, cabinate light and door locking arrangement complete all as specified and directed. MAKE- Blue Star, Voltas.
Supply, installation, commissioning and testing of metal top deep freezer single phase 240 volts, 50 Hz of capacity 300 to 320 Litres, temprature range < -26 degree celcius to < 8 degree celcius having 5 star rating with minimum 5 years compressor warranty and anti radient cabinate, cabinate light and door locking arrangement complete all as specified and directed. MAKE- Blue Star, Voltas.
S & F of socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC complete all as specified and directed.
S & F of switch piano flush button single pole 230 volts, one-way 15 Ampere complete all as specified and directed.
Material and Labour for providing maintenance free copper chemical Earthing comprising 50 mm dia, 3.00 m long pure copper earthing electrode with stainless steel connectors suitable for copper earth strip with and including digging suitable hole of minimum 4" dia with Auger upto a depth of 4.00 m deep suitable for insertion of 3.00 m long copper rod earthing electrode, filling the hole with advanced enchancing compound (Chemical) minimum quantity 25 Kg, filling the complete hole with water till complete soaking of the chemical compound, placing of pre-fabricated FRP pit cover on the earthing, ramming of the earth pit cover with soil properly, placing of FRP cover of size 10" X 13" with a height of 10.25" over earthing pit, 99% pure copper earth strip of size 25 X 3 mm for earthing device up to 7.50 metres duly connected with stainless steel connectors by means of the brazing / copper nut-bolts, earth test point of galvanised iron of size 75 X 75 X 25 mm, necessary excavation and earthwork in any type of soil including disposal of surplus soil to a distance not exc. 50 metres complete all as specified and directed. MAKE OF EARTHING- True power Earthing, LPI, Elopp, Ennov, SG Power, G-Max Earthing. NOTE:- Additional earthing compound if required on account to achieve earth resistance less than 1.00 ohm shall deemed to be included in the unit rate of this item. On testing after completion of job, if desired earth resistance (i.e. less than one ohm) is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
S & F of flush mounting factory made SPN, sheet metal enclosure for DB's when MCBs to be used single door, 2 way without bus bar complete all as specified and directed.
S & F of isolator, SPN, 40 Ampere breaking capacity 10 KA, 240 volts complete all as specified and directed.
S & F of 1100 volts grade heavy duty two single core 2.50 Sqmm size PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into and including PVC conduit medium grade not less than 25 mm dia including its all accessories & fittings, fixed concealed with and including chase cutting and making good the same as per existing specifications along with a continuous run of multi-stranded copper conductor of size 2.50 Sqmm PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed. NOTE: - TWO SINGLE CORE CABLES ALONG WITH EARTH WIRE AND PVC CONDUIT SHALL BE MEASURED AS ONE UNIT LENGTH.
LAMBA BUILDERS
Builders Harpal
M M CONSTRUCTIONS
NOORI ENTERPRISSES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .