ASSISTANT EXECUTIVE ENGINEER
O/o ASSISTANT EXECUTIVE ENGINEER, PWD ELECTRICAL SUB DIVISION, IDUKKI, PAINAVU.
Department of Tourism - Supply, installation testing and commissioning of 62.5 kVA DG set at Government Guest House, Idukki.
2021_PWD_463654_3
03/ET/2021-22
Open Tender
Electrical Works
Item Rate
70 days
IDUKKI
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,085
₹23,650
21 Apr 2022
10 Feb 2022
23 Feb 2022
10 Feb 2022
18 Feb 2022
10 Feb 2022
Amount
DG installation
od174872/2018_2019 : Supply, Loading, Conveyance, Unloading of 62.5KVA DG Set with Acoustic enclosure as per CPCB II norms and as detailed below (1) Engine a) Make of engine – Cummins / Equivalent. b) Type of Engine - Diesel Engine. c) No of Cylinders - As per manufactures standars. d) Method of cooling - Water cooled with radiator. e) Aspiration - Naturally Aspirated. f) Design - Suitable for generating set operation. g) Output - Suitable for generating set operation. (2) Standard accessories with Diesel Engine. a) Fly wheel. b) Close Coupled. c) Air cleaner. d) Raditor with fan provided with fan guard. e) Fuel Pump. f) Mechanical governor. g) Fuel filter. h) Lubricating oil filter. i) Residential type exhaust silencer. j) Battery Charger / Generator. (3) Engine Instument Panel with the following items. a) Starting switch with key or button . b) Lubricating oil pressure gauge. c) Water temperature gauge. d) RPM Indicator with hour meter e)Battery charging ammeter.( 4) Saftey Controls for Engine. a) Battery control (trip) for low ludricating oil pressure. b) Battery control (trip) for high water temperature. (5) Brushless alternator. a) Make - Stamford / Equivalent . b) Type - Self exited and self regulated. c) Capacity - 62.5KVA/50KW @ 0.8PF. d) System of Voltage - 3Phase, 415V, 4Wire system. e) Speed - 1500 rpm. f) Frequecncy - 50Hz. g) Insulation - Class F/H The alternator should confirm to IS 4722/IS13365 Operation and service manual shall be provided. (6) Fuel Tank-Suitable size fitted (built in type) inside the acoustic enclosure . (7) Battery -Suitable size fully charged battery with leads and terminals of appropriate AH capacity as per Manufactures required including battery charger. (8) Standard control panel. a) 100A/125A 4Pole MCCB Set at 87A. b) 1 No multifunction meter suitable for display of current in 3Phases, voltage in 3Phases, frequency, power factor, KVA, KVAh, KVAr, KVArh, KW etc. c) 1 No separate KWH meter. d) Instrument fuse/MCB . e) Metallic DNB - 1No. f) Solid state phase indication lamp for supply ON/OF with Fuse / MCB protection. (9) Warrantee 3 Year. (10) with first full filling of diesel
od40805/2021_2022 : Fabrication, Installing, Testing & Commissioning of microprocessor based automatic mains failure control including auto by pass panel, suitable for 62.5 KVA, 3 phase, 415V, 50 Hz DG Set complete with all standard features, relays, timers, set of CTs for metering & protection and energy analyzer to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH, KVAH & provision for overload, short circuit, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and mechanical & electrical inter locking, connecting the existing power cables including the following:-1). Control panel shall be fabricated out of 1.6 mm thick CRCA sheet powder coated, totally enclosed, dust, damp and vermin proof, wall/floor mounted, no mixing of control, power, DC and AC functions in the same section, sufficiently segregated with single leaf hinged door in the front, indication and instrument meters shall be flushed in the front, powder coated to a minimum thickness of 50 microns and degree of protection required will be IP-42 confirming to IS 2147 including 2 set of 100A TPN MCCB, 2 set of 100 A 4P contractor with suitable indicators and meters including DG battery charger
90.12.5.29 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 50 sq mm
90.12.7.29 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
90.12.5.38 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 4 sq mm
90.12.7.38 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp
90.12.10.3 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size
90.12.10.2 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.20 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)
od175552/2018_2019 : Supplying siemens / tropodur type nickel plated Double compression brass cable gland for PVC insulated and PVC sheathed armoured aluminium/ copper conductor cable 1.1 KV grade, and making end termination suitable for 2/ 3/ 3½/ 4 core cable of the following sizes as required. 4 sq.mm
od175596/2018_2019 : Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for cables 25 sq - 95sq mm with 20 mm wide x 1.20 mm thick clip as required.
od40807/2021_2022 : Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required. 4 sq.mm
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.4 : Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.5 : Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.14.2.1 : Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.1 : Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
90.14.6 : Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7 : Supply and providing copper earth bus in the panel board
2.2.13 : Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required100 Amp, 30 KA 4 Pole
90.14.11.1 : MCCB AccessoriesSupply and fixing one number earth fault Relay up to 100A with CBCT.
90.14.11.12 : MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.
90.14.11.13 : MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
od41108/2021_2022 : Supplying and fixing 160A 2 Way neutral links mounted on DMC/SMC base and giving connections in the existing meter board/panel.
od41110/2021_2022 : Supplying and fixing of 160A Fuse bases L&T HB 160 / Equivalent & DIN fuse-links suitable for HN size 000 / 00 and giving connections in the existing meter board/panel
od41196/2021_2022 : Supply and installation of LED indicators for all voltage ranges-Blue colour.
od41198/2021_2022 : Supply and installation of LED indicators for all voltage ranges-Red, Green, Yellow or Orange colour.
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
od41200/2021_2022 : Carrying out control wiring for panels with sophisticated control devices such as relays, PLC etc including detailed Engineering, generating the required drawings according to the logical requirement etc with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required including conducting trial run after completion of the wiring, making corrections if required and make the system in perfect working condition. 1.50 sq mm single run with required sockets.
od41202/2021_2022 : Carrying out control wiring for panels with sophisticated control devices such as relays, PLC etc including detailed Engineering, generating the required drawings according to the logical requirement etc with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required including conducting trial run after completion of the wiring, making corrections if required and make the system in perfect working condition. 4.00 sq mm single run with required sockets.
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
od41192/2021_2022 : Supply and fixing Enameled Danger Notice Board of size 150 x 100 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour.
od41112/2021_2022 : Aluminium anodised legend plate of size 40 x 20 mm. with inscription of EARTH.
od41114/2021_2022 : Aluminium anodised legend plate of size 100 x 40 mm. with inscription of CABLE ALLEY.
od41116/2021_2022 : Aluminium anodised legend plate of size 100 x 40 mm. with inscription of BUS BAR CHAMBER .
od41090/2021_2022 : Painting letters or figures of the follwing sizes with enamel paint as identfication mark to SB, DB, panel board etc as required. 2.5 cm, 4 cm, 5 cm height.
5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
90.16.1.6 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required6.00 mm copper conductor (4 SWG)
od41152/2021_2022 : Supply and laying bare copper earthing conductors of 6.00 mm copper conductor (4 SWG) size laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil).
90.16.5.6 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.6. mm ( 4 SWG)
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
od176006/2018_2019 : Supply and providing 25 x 3 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required.
od176008/2018_2019 : Supply and providing 25 x 6 mm brass bolt & nut. with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required.
14.8 : Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
od39386/2021_2022 : Supply and providing the following size of B class MS pipe conforming to relevant IS specifications complete with heavy gauges specials such as bends, flanges etc welded and fixed at appropriate locations, providing cork sheet in between the flanges at the joints, bolting the flanges together, painting the pipe, flange etc with 2 coats of heat resistant paint suitable for outdoor applications, fixing the pipe firmly with fabricated structure/wall/any other mechanical support etc as required.- 80 mm dia B class MS pipe as extended exhaust pipe. as per the direction of department staff at site (fire approved rate)
od40828/2021_2022 : Cladding for Exhaust system by wrapping mineral wool around the exhaust system (pipe) fixing it firmly with the pipe using chicken mesh applying overall coating to the system using 0.4mm thick aluminum sheet and make it air tight to ensure sound and thermal proof to the system
od41184/2021_2022 : Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.
od41186/2021_2022 : Supply and providing 3mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 11 KV dielectric strength.
90.6.10.1 : Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
1.17.1 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
od41188/2021_2022 : Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.
od41190/2021_2022 : Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.
od53907/2021_2022 : Supply and laying of one number additional PVC insulated and PVC sheathed armored copper power cable of 1.1KV grade 2.5SQMM X 8 CORE of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)
od53945/2021_2022 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required 2.5sqmm x 8 core
od41164/2021_2022 : Charges towards the preparation of necessary plan, scheme and other related papers for submission
od41166/2021_2022 : Charges towards the preparation of necessary plan, scheme and other related papers for additional sheet.
od40824/2021_2022 : Fees to be remitted to Electrical Inspectorate / Meter testing lab / Fire & rescue service Department (Actual amount incurred for the above items will be reimbursed on production of Original Receipts)
od40826/2021_2022 : KSEB Fee Load enhancement from 28kW to 50kW, Meter shifting, ACD, CT type Energy meter & CT fixing ,CT , testing etc. (Actual amount incurred for the above items will be reimbursed on production of Original Receipts)
Bidder Name
M Y ASSOCIATES
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_679743.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .