Executive Engineer, Electrical Wing
Executive Engineer, Electrical Wing, University of Calicut
Replacement of damaged electrical accessories and connected electrics at CUTEC, Chakkittapara
2023_UoC_550216_1
D3/E-Tender No.41/2022-23
Open Tender
Electrical Works
Item Rate
60 days
University of Calicut
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,062
₹6,750
18 Apr 2023
17 Jan 2023
28 Jan 2023
17 Jan 2023
24 Jan 2023
17 Jan 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A. (1.10.1)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C. (1.10.3)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2x1.5 sq.mm + 1x1.5 sq.mm earth wire. (1.14.1)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (1.14.2)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2 X 4 sq. mm + 1 X 4 sq. mm earth wire(1.14.3)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required .3 X 1.5 sq.mm. (1.17.3)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm. (1.17.12)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm. (1.17.21)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required - 20 mm. (1.21.1)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm. (1.21.2)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch. (1.24.1)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 amps switch. (1.24.2)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch. (1.24.3)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet. (1.24.4)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet. (1.24.5)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Bell push. (1.24.8)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (1.25)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (1.26)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX 75mm). (1.27.2)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 8 Module (125mm X 125mm). (1.27.5)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module. (1.28.1)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 3 Module. (1.28.2)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required . 4 Module. (1.28.3)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 6 Module. (1.28.4)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 8 Module (1.28.5)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 12 Module. (1.28.5)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residential buildings). (1.31)
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. (1.33)
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. (1.38)
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).(1.56)
Supplying and fixing PVC batten/ angle holder including connection etc. as required. (1.58)
Supply & Installation of light fittings on flat iron bracket. Supply conveyance installation testing and commissioning the light fittings of following types made of Aluminium housing 0.5 mm thickness complete with all accessories and lamps etc,directly on wall using 2 nos flat iron bracket made from 25 x 6mm flat iron, painting the flat iron bracket suit the fittings and giving connection with required length of 16/0.20 mm 3 core copper conductor flex wire conforming to relevant iss and giving connections as required .1200 mm 1 x 20 W LED Lamp with box type fixture. (od265221/2022_2023)
Supply & Installation of light fittings on T W/ PVC Round block . Supply conveyance installation testing and commissioning the light fittings of following types made of Aluminium housing 0.5 mm thickness complete with all accessories and lamps etc,directly on wall or ceiling with PVC round block neatly painted to suit the fittings and giving connection with required length of 16/0.20 mm 3 core copper conductor flex wire conforming to relevant lss and giving connections as required .1200 mm 1 x 20W LED Lamp with box type fixture. (od265222/2022_2023)
Charges for replace the damaged ceiling fan and Supply, installation, testing and commissioning of BEE and PWD approved, 1200 mm sweep regulator friendly BLDC Ceiling fan, complete with 300mm down rod, canopies, shackles and blades working on 230/240V single phase A/C in existing hook .Damaged fan return to the Electrical sore. (od265223/2022_2023)
Labour charges for dismantling damaged tube set .And Installation and commissioning of LED tube set on the existing round block which fixed direct on wall. (od265224/2022_2023)
Labour charges for dismantling existing damaged electrical accessories from the existing switch boards such as switches,sockets,indicators,cover plate and fan regulators etc. Dismantled electrical accessories return to the electrical store with out causing any further damage. (od265226/2022_2023)
Supplying and fixing fan hook for 1200/1400 mm AC ceiling fan. (od265227/2022_2023)
Supply, Installation, testing and commissioning of exhaust fan in the existing opening after dismantling the old one , including making good connection etc. as required.Upto 450 mm sweep. (od265228/2022_2023)
Dismantling the existing Switch boards with related accessories from the wall without causing any damage and return to the Electrical store. (od265229/2022_2023)
Dismantling of existing ceiling fan, including disconnecting connections and return to the electrical store without causing any damage. (od265232/ 2022_ 2023)
Dismantling the 1400/1200 mm AC ceiling fan overhauling greasing and refixing the same on the existing fan hook after repainting with 2 coat of enameled paint over the primer and giving connection etc.. Complete. (od265233/2022_2023)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and netural. (2.10.2)
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required. (2.16)
Charges for replace the old tube set and supplying ,installation 1200MM 1x20 w LED lamp with box type fixture made of aluminium housing 0.5 mm thickness (LED tube set) in same existing frame and fit it (including bracket , round block down rod etc tube set, (od266115/2022_2023)
Supply and laying 1 sq mm 3 core unarmored round copper conductor flex wire. (od266131/2022_2023)
Supply and fixing 32 mm dia GI pipe (medium class) in wall for fixing street light including bending the pipe to the required shape complete as required. (od266132/ 2022_2023)
Supply and installing integrated 70 -80W street light with IP 66 Protection(PWD Approved makes mandatory) with fittings, all accessories and 1.5 meter 3 core 1.5 sq mm W/P cable to fix in the wall of building. (od266133/2022_2023)
Supplying 2.5 Sq.mm 3 core flat copper cable suitable for submersible pump set. (od266155/2022_2023)
HELVUS ENGINEERING
Nijilesh P
ELECTROWIND ENGINEERING CO
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_806634.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .