| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC ACCEPTANCE LETTER UPLOADED | |
| 2 | L2₹17.0 L+₹1.8 L (12.2%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹18.0 L+₹2.8 L (18.6%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder |
Tender Value
₹20.0 L
EMD Value
₹39,924
Closing Date
23 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Banar
Garrison Engineer Banar, Jodhpur-342027
REPAIR AND REPLACEMENT OF SUMMER AND WINTER APPLIANCES AND ITS CONNECTED ITEMS AT NAGTALAO UNDER GE BANAR
2024_MES_661917_1
8824/23/E8
Open Tender
Civil Works
Item Rate
180 days
Banar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer Banar
₹39,924
Yes
28 Nov 2024
25 Jun 2024
30 Jul 2024
25 Jun 2024
23 Jul 2024
9 Jul 2024
Amount
M&L for Taking out window/Split type AC of capacity up to 2 Ton from the site and make for servicing, cleaning with air blower of fins, cleaning of condensing unit, cooling coil and evaporative coil with caustic soda mix water,taking out all dirt/sludge etc. by using pressure pump ,cleaning of air filter incl. Oiling and greasing of condensing fan motor, Replacement of remote cell/battery replacing worn out rubber,bushes/rubber packing rectification of unusual noise. Replacement of minor parts such as nut/bolts,washers etc and reassembly of complete AC unit and testing complete all as specified.
M&L for package type AC of capacity up to 8 Ton (3x8 count one unit) at the site and make for servicing, cleaning with air blower of fins, cleaning of condensing unit, cooling coil and evaporative coil with caustic soda mix water,taking out all dirt/sludge etc. by using pressure pump ,cleaning of air filter incl. Oiling and greasing of condensing fan motor, Replacement of remote cell/battery replacing worn out rubber,bushes/rubber packing rectification of unusual noise. Replacement of minor parts such as nut/bolts,washers etc and reassembly of complete AC unit and testing complete all as specified.
M&L for Topping up of refrigerant as per the existing refrigerant upto the required level for window /split type AC of capacity 1.5/2 ton complete all as specified.
M&L for complete Gas charging as per the existing refrigerant up to the required level and replace NRV for window/Split type AC of capacity 1.5/2 Ton complete all as specified.
M&L for Taking out defective compressor Sealed Rotary / Reciprocating unit of window AC of cap 1.5 Ton incl.cutting of copper tubing without any damage to existing other parts and Material and labour for replacement of compressor/ sealed unit complete with erection of compressor in same location with suitable base,jointing of copper refrigerant pipe line,charging of gas to required level,leakage testing,NRV etc. including testing for smooth functioning. NOTE : (i)The rate quoted by the contractor shall be inclusive of all charges like transportation,fittings,etc. complete with necessary guarantee period including oiling and environment friendly gas charging , testing etc.complete all as specified.
All as per ser No 5 above but split type AC of cap 1.5 Ton complete all as specified.
All as per ser No 5 above but split type AC of cap 2 Ton complete all as specified.
M&L for replacement of blower bush of split type AC having capacities of 1.5/2 Ton complete all as per the sample existing at the ground complete all as specified.
Supply and fix in repair blower fan motor of suitable size for indoor type split AC of cap 1.5/2 Ton complete all as specified.
Supply and fix in repair condensor fan motor suitable for out door type split AC of capacity 1.5/2 Ton complete all as specified.
M&L for taking out u/s blower of wnidow type AC of cap 1.5/2.00 ton and supply and fix blower of approved make suitable for existing window type AC of cap 1.5/2.00 Ton complete all as specified.
S&F in repairs/replacement of running capacitor, 45/60 mfd suitable for 1.5 /2 Ton capacity window/split type AC of approved make complete all as specified.
S & F capacitor 6/10 mfd suitable for split / window type AC complete all as specified.
M&L for repairing of PCB control kit of window / split type AC of capacity 1.5/2Ton complete all as specified.
M & L for replacement of PCB control kit suitable for window/split type AC of capacity 1.5/ 2 Ton complete all as specified.
Takingdown indoor & outdoor unit of 1.5/2TR split AC and refix again existing/another place including faster complete all as specified.
S&F in repairs/replacement of Thermostat (Thermal sensing bulb) suitable for split/window type AC 1.5 /2 Ton capacity of approved make complete all as specified.
S&F in repairs/replacement of starting and running relay suitable for window/ split type AC 1.5/2 Ton capacity of approved make complete all as specified.
S&F in repairs/replacement of over load protection suitable for window/ split type AC 1.5 /2 Ton capacity of approved make complete all as specified.
M&L for Taking out u/s drain out pipe of split type AC unit and supply and fix new drain out pipe of approved make complete all as specified.
Supply and fix in repair/replacement of condensing coil of window type AC of capacity 1.5 Ton complete all as specified.
Supply and fix in repair/replacement evaporating coil of window type AC of capacity 1.5/2 Ton complete all as specified.
Supply and fix in repair/replacement of evaporating coil of split type AC of capacity 1.5 /2 Ton complete all as specified.
Supply and fix in repair/replacement of condensing coil unit complete of out door unit of split type AC of capacity 1.5/2 Ton complete all as specified.
M & L for replacement of chocked copper tube of size 1/4" of split type AC 1.5/2 ton cap complete all as specified.
M & L for replacement of chocked copper tube of size 1/2" of split type AC of 1.5 /2 ton cap complete all as specified.
M & L for insulation coating /PVC air bubling insulation of circular dia to copper tube to upkeep the required temperture and over all protection to copper tubing of size 1/4" or 1/2" complete all as specified.
M & L for taking out water Cooler from site of any capacity and make for servicing incl. cleaning of cooling tank and condencing coil with C sine cemical mixed water, taking out all dirt , sludge deposited, incl. oiling / greasing of condensing fan motor rectification of unusual noise, replacement of minor parts such as nut/bolt washers etc as directed with writing of serial No SM/MES No. and re installed the water cooler in position complete all as specified.
M&L for Topping up environment friendly refrigerant as per existing suitable for water cooler up to the required level of 40/80 ltr complete all as specified.
M & Labour for spray painting to water cooler of capacity 40 lit and cooling capacity 80 lit per hour by painting outer cover with two coat of synthetic enamel paint of approved make complete all as specified.
M&L for Taking out defective sealed compressor unit of 40/80 Ltr/hr cap of water cooler and M & L for replacement for sealed compressor unit of suitable for water cooler of 40/80 lit/hr cap , reassembly and testing complete all as specified.
M & L for finding out leakage of condensor/ cooling unit of water cooler of 40/80 Ltr cap including dismantling the same for recharging and stop leakage by brazing/soldering including charging with existing gas up to required level and testing complete all as specified.
Material and Labour for replacement of capacitor 10 mfd oil filled for water cooler Make ; Asian/Atlas/Epcos.
Supply and fixing OLP rellay suitable for water cooler,Refrigerator and deep freezer of any capacity complete all as specified.
M & L for replacement of condenser fan motor of water cooler 40/80 ltr/hr capacity as per existing sample or approved make and testing complete all as specified.
M & L for replacement of fan blade of water cooler/blower as per existing sample at the ground complete all as specified.
S & F in repairs of Thermostat suitable for water cooler 40 Ltr/hr capacity of approved make complete all as specified.
Supply and fix Ball brass valves size 15mm, high pressure,with polythene float and flynut complete,screwed for iron pipe or brass ferrule complete all as specified.
M&L for replacement of defective sealed compressor unit upto 320 Ltr cap refrigerator. The rates quoted by the contractor shall be inclusive of all charges like transportation fitting etc complete with necessary guarantee period including checking and rectification of any leakage in system and make it functional to entire satisfaction of EIC incl oiling, greasing, gas charging and testing complete.
M&L for finding out leakage with the pressure testing of the condensor/ cooling unit/ compressor of refrigerator upto 320 Ltr cap, stop leakage by brizing/soldering including charging the environment friendly refrigerant up to the required level and testing the refrigerator for the entire satisfaction of EIC.
M&L for replacement of defective sealed compressor unit of 320 ltr cap deep freezer. The rates quoted by the contractor shall be inclusive of all charges like transportation fitting etc complete with necessary guarantee period including checking and rectification of any leakage in system and make in functional to entire satisfaction of EIC incl oiling, greasing, gas charging and testing complete all as specified.
M&L for finding out leakage with the pressure testing of the condensor/ cooling unit/ compressor of deep freezer 320 Ltr cap, stop leakage by brizing/soldering including charging with existing refrigerant to required level and testing the refrigerator for the entire satisfaction of EIC.
S & F replacement of defective swing motor with new motor suitable for 1.5/2 ton window and split type AC complete all as specified.
Supply and fix in repair front grill for window type AC 1.5 /2.0 TR. complete all as specified.. MAKE: LG,Carrier,Samsung,Voltas,Hitachi.
Replacement of unserviceable remote with new suitable for machine of 1.5/2.0 TR split type AC complete all as specified.
Dismantling to voltage stablizer upto 4 KVA for repair including assembling , testing after repair work complete all as specified.Note:- Spare parts will measured under item no 51 & 52
S&F replacement of Indoor unit complete with cooling coil, blower/ fan, motor complete suitable for 1.5 Ton split AC. Make : LG/Voltas.
S&F replacement of outer cover of outdoor cabinet of split AC 1.5Ton with stand including fashner,nut,bolts etc complete all as specified.
S&F in repair 3 core PVC insulated copper cable of size 2.5 Sqmm multi stranded complete all as specified.
Supply only Circuit board suitable for upto 4 KVA complete all as specified.
Supply only relay suitable upto 4 KVA complete all as specified.
Inspection,checking adjustments and minor repairs of storage water heater 25/35/50 ltr capacity of any type any make vertical/ horizontal type which includes the following :- (a) Inspection, taking out of drain plug & dewatering and refix the same complete all as directed . (b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts. (d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow. (e) Checking and correct earth continuity of electrical items. (f) Checking functioning of heating element and correct setting adjustment of thermostat upto 55º C. (g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. Note : (1) Irrespective of the complaints, work against entire qty under this item of BOQ shall be completed with in set period of 45 days after handing over the site as per work order failing which recovery @ Rs 50/-/per geyser per day delay shall be effected from the contractors payment. (2) Spare part paid shall be seprate under this item
Taking down geysers of any type and any capacity due to rusting of bolts/seepage of wall and re-installation at any location including S&F in repair of heavy duty pin type fastener 4” long and making necessary inlet/outlet electric & water supply connections from existing source to geyser complete all as specified.
Supply only heating elements ISI Marked of following different capacity complete all as per site requirement as directed by Engineer-in-Charge :- (a) Capacity 1.50 KW
As item No 55 above but Capacity 2.00 KW complete all as specified.
Supply only thermostat cutout suitable for 1.5/2.00 KW geyser complete all as specified.
Supply only Stainless steel connection pipe 15mm bore,heavy duty suitable for 1.50/2.00 KW geyser complete all as specified.
Supply and fix in and replacement of glass wool for geysers complete all as specified.
S&F in replacement base assembly, compatible to existing gyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified.
S&F in replacement Multifuction /Non return valve ISI marked of capacity 15mm/20mm dia connecting up complete all as specified.
M&L for replacement of copper conductor cable 4 Sqmm 3 core upto 5 m long with plug top 5 Amp inbuilt suitable for desert cooler (Make FINOLEX/PARAGUN/POLYCAB).
S&F in replacement indicator lamp set with wire kit for geyser of any type colour green & red complete all as specified. Make : Usha / Bajaj/ Crompton
S&F in replacement stainless-steel inner tank of minimum 20 gauge sheet rated pressure not less than 7kg/sqcm suitable for 25 ltrs capacity geysers (wt not less than 3.75 kg) as per sample complete all as specified.
S&F in replacement of stainless-steel inner tank of minimum 20 gauge sheet rated pressure not less than 7 Kg/sqcm suitable for 50 ltrs capacity geysers (wt not less than 5.25 kg) as per sample complete all as specified.
S&F in replacement outer body of MS sheet not less than 20 gauge suitable for 25 ltr geyser with white synthetic enameled paints complete all as specified.
S&F in replacement outer body of MS sheet not less than 20 gauge suitable for 50 ltr geyser with white synthetic enameled paint complete all as specified.
S&F in replacement bottom cover of MS sheet 20 gauge suitable for 25 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified.
S&F in replacement bottom cover of MS sheet 20 gauge suitable for 50 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified.
S&F in repair 3 core PVC insulated copper cable of size 2.5 Sqmm multi stranded complete all as specified.
M&L for painting of outer surface of 25/50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified.
S&F Metal Clad Plug and socket with box 20 Amp with MCB single pole complete fixed properly on wall surface with the provisioning of suitable sizes of bolts, nuts, washer and to connect by using cable PVC insulated copper stranded conductor of size 4 Sqmm complete all as specified.
Supply and fix in repair Pin Top 15 Amp ISI Marked complete all as specified.
Supply and fixing in repair Metal plug and socket boths 20A single phase 3 pin as per IS 8804 suitable for existing metal clad box as per specification complete all as specified.
Material and labour for painting to old steel surfaces of Desert cooler of Air flow capacity up to 5000 Cu M/hr with two coats of synthetic enamel spray paint hammer tone paint of approved colour make ICI paint (Dulax closs), asian paint (Apcolite), Jenson & Nicholson,over one coat of red oxide on external surface and two coats of anti corrosive black paint inside the Body tank and side grills over a coat of Red Oxide on internal surfaces including scraping/rubbing with wire brush on old surface of Desert cooler. and writing of MES No in 25mm height etc complete all as specified.
M&L for replacement of copper conductor cable 40/0.75 Sqmm 3 core 3 to 5 m long with plug top 5 Amp inbuilt suitable for desert cooler (Make FINOLEX/PARAGUN/POLYCAB).
M&L for Replacement of PVC water distributor with PVC pipe and PVC pipe elbow complete for desert cooler upto 5000 CFM complete all as specified.
M&L for replacement of Fan blade of desert cooler heavy duty MS suitable for 4000/5000 CFT cap complete all as specified.
M&L for replacement of Water lifting submersible pump of head 1.2 m approx suitable for desert cooler as per existing capacity. (Make : Snow Cool/LITTLE)
M&L for Taking down desert cooler fan motor and supply and fixing new desert cooler fan motor with outer ring and nut-bolts for desert cooler upto 5000 CFM copper wounded, three speed approved make complete all as specified.
M&L for Taking down u/s desert cooler motor, cutting of burnt out winding and rewinding super enamelled copper conductor fixing of desert cooler motor to existing location complete all as specified and directed by Engr-in-Charge. make all as directed by EIC. Note:- Contractor will produce Guarantee letter for the rewinding of the motor minimum 1 year from the date of installarion and testing.
Supply & Fix in repairs wood wool Pad (set of three), minimum weight 0.80 kg, inside panels of desert coolers complete all as specified.
M&L for Replacement of rusted and leakaged body parts Water tank of Desert cooler of 4000/ 5000 CUM/hr capacity as required at site with existing gauge of sheet :-
All as per Ser No 84 above but herein Side lags complete all as specified.
All as per Ser No 84 above but herein Top cover complete all as specified.
All as per Ser No 84 above but herein Front grill with connection stripcomplete all as specified.
All as per Ser No 84 above but herein Supporting legs with frame and clips incl nuts & bolts of desert cooler.
M&L for taking down fan of any type/make and size carefully from fan hook, dismantling of blades and transporting from any location in side army area to MES E/M store yard for washing throughly of bearing/bush by petrol , washing and cleaning the fan blades , body , canopy etc throughly , provision of new greasing , replacement of worn out/ defective unserviceable parts including fan rod (wherever necessary ) reassembling the same and testing the fan on full load to entire satisfaction of Engr-in-Charge Note:- (i) Replacement of defective / unserviceable parts will be paid separately under relevent items of this schedule(ii) The cost for labour to taking out and refixing the new material is deemed to be inclusive of quoted rates. (iii) Any type of petty items which are not included in this schedule will deemed to be inclusive of quoted rates.
M&L for Hanging carefully ceiling fan in hook and make connection with exsiting point wiring including provision of three core (FRLS)cable not less than 0.75 sqmm of size from ceiling rose or connector to ceiling fan complete all as specifed. Note:- Any petty items like nut bolts washers & safety pin etc required for hanging deemed to be inclusive of quoted rates.
M&L for Removing rusts/dusts cleaning thoroughly with petrol to the ceiling fan in situ and spray painting with one coat to ceiling fan of any size and type with 1st quality synthetic enamel paint as per exsisting colour to fan body, down rod/ canopy etc and writing the MES number as MES/NT-(No) on the fan body in black paint complete all as specified.
M&L for taking down burnt out ceiling fan of any type and size , dismantling the fan blades ,opening the cover to Cutting the existing copper winding and rewinding the armature (Rotor) with super enamelled copper wire of suitable gauge incl all insulating materials complete and re-assembling the fan, fan blades and hanging in fan hook to the same location by providing three core copper (FRLS) cable not less than 0.75 sqmm from ceiling rose or connector to fan and satisfactory testing on full speed to entire satisfaction of Engineer-in-Charge.Note:- (i) Contractor will produce guarntee letter for rewinding of fan minimum 1 year from the date of installation and testing (ii) The cost of transportation will deemed to be inclusive of quoted rates.(iii) Cost of labour for taking down and refixing will deemed to be inclusive of quoted rates.(iv) Any petty items required for fixing will deemed to be inclusive of quoted rates.
M&L for Turning of fan shaft after re-metalling and welding including cutting threading welding and the materials for exhaust fans of any size and Make.
M&L for Filling (Metalling) the worn out shaft at bush/ball bearing seat by welding and machining for proper fixing of ball bearing/bush of any size of ceiling fan complete all as specified.
S&F in repair of fan blades set of ceiling fan for any sweep of the existing complete all as specified.
S&F in repair of plastic canopy upper & lower of any size and make of ceiling fan fixed with suitable size of screws complete all as specified.
S&F rubber reels incl shackle clamp, bolts, nuts, washers split pins of appropriate size as required at site complete all as specified.
S& F ball bearing of suitable to ceiling fan including testing complete all as specified. Make:- SKF/NBC/SBBI
S&F bush bearing made out Gun metal suitable for ceiling fan complete all as specified. Make:- SKF/NBC/SBBI
M&L for down rod of 15mm dia GI pipe heavy duty 45 cm long incl machining/ threading/drilling hole of size suitable for nuts and bolts washer and split pin suitable to any type and sweep size of fan.
M&L for Dismantling of wall mounting Air circulating fan for washing thoroughly of bearing/bush by petrol / cleaning of fan blades and body etc ,greasing and oiling complete, re-fixing the same to existing location after painting with synthetic enamel paint of approved make with spray gun of one coat as per exsisting colour , connecting and testing on full speed to entire satisfaction of Engineer-in-Charge of following sizes (i) Replacement of defective / unserviceable parts will be paid separately under relevent items of this schedule(ii) The cost of labour to taking out and refixing the new material is deemed to be inclusive of quoted rates. (iii) Any type of petty items which are not included in this schedule will deemed to be inclusive of quoted rates. of size (a) 600 mm sweep any make.
All as per Ser No 101 above but 380-450 mm sweep any make complete all as specified.
M&L for taking down the burnt out wall mounting air ciculator fan dismantal the blades ,opening the cover to cutting the existing copper winding and rewinding the armature (Rotor) with super enamelled copper wire of suitable gauge incl all insulating materials varnishing and heating complete and refixing at same location after painting to entire body of wall mounting fan with synthetic enamel paint as per exsisting colour by using spray gun incl satisfactory testing on full speed complete all as directed by Engineer-in-Charge of the following sizes Note:-(i) Cost of items except rewinding will be measured and paid separately under relevent items of this schedule (ii) Quoted rate is deemed to be inclusive of transporting and taking down unserviceable/defective parts.of size (a) 600 mm sweep any make
All as per Ser No103 above but 400-450 mm sweep any make complete all as specified.
S&F in repair condenser of 240 volts 2.5 MFD suitable for ceiling fan 1200/1400mm sweep size incl testing (Make : Usha/Asian/EPCOS) complete all as specified.
S&F in repair condenser of 240 volts ,10 MFD suitable for wall mounting air circulating fan 600 mm incl testing (Make : Usha/Asian/EPCOS) complete all as specified.
S&F in repair condenser 240 volts 8 MFD suitable for wall mounting air circulating fan 450 mm incl testing (Make : Usha/Asian/EPCOS) complete all as specified.
S&F in repair Condenser 240 volts 4 MFD suitable for wall mounting air circulating fan 400 mm incl testing (Make : Usha/Asian/EPCOS) complete all as specified.
S&F ball bearing of size suitable for 600 mm sweep Air circulating fan incl testing (Make : NBC/SKF/SBBI) complete all as specified.
S&F ball bearing of size suitable for 450/400 mm sweep Air circulating fan incl testing (Make : NBC/SKF/SBBI) complete all as specified.
S&F in repair of damaged/defective MS fan blades for 600 mm sweep Air Circulator fan complete all as specified.
S&F in repair of damaged/defective MS fan blades as per existing for 450/400 mm sweep Air Circulator fan complete all as specified.
M&L for taking down exhaust fan carefully from site & transporting from any location inside Army area to MES E/M store yard for stripping of fan washing thoroughly of bearing/bush by petrol, washing fan blade body etc thoroughly provision of new greasing replacement of worn out/defective unserviceable parts (wherever necessary) assembling the same incl connection by providing three core copper (FRLS) cable not less than 0.75 Sqmm from ceiling rose to fan and testing on full speed to entire satisfaction and fixing at original location complete all as directed of following size :- (a) 450 mm sweep any make, Note :- 1. Replacement of parts/rewinding shall be measured and paid separately. 2. Quoted rate is deemed to be inclusive of transporting and taking down unserviceable/defective parts.
All as per Ser No 113 above but 380 mm sweep any make complete all as specified.
All as per Ser No 113 above but 300 mm sweep any make complete all as specified.
M&L for Rewinding the armature of exhaust fan of any make with super enamelled copper wire of suitable for incl all insulating materials varnishing complete incl satisfactory test run on full speed complete for the following :- (a) 450 mm sweep exhaust fan any make
As item No 116 above but 380 mm sweep any make complete all as specified.
As item No 116 above but 300 mm sweep any make complete all as specified.
S&F ball bearing of size suitable for 300 to 450 mm exhaust fan incl testing and refixing complete (Make : NBC/SKF/SBBI) complete all as specified.
S&F bush bearing made out Gun metal of size suitable for 450 to 300 mm of exhaust fan incl testing and refixing complete. (Make : NBC/SKF/SBBI)
M&L for Replacement of supporting legs with frame and clips incl nuts & bolts of size suitable for 380 mm sweep size exhaust fan incl taking down unserviceable leg frame complete all as specified.
M&L for Replacement of supporting legs with frame and clips incl nuts & bolts of size suitable for 300 mm sweep size exhaust fan incl taking down unserviceable leg frame complete all as specified.
M&L for Replacement of damaged/defective MS fan blades assembling for 450 mm sweep exhaust fan complete all as specified.
M&L for Replacement of damaged/defective MS fan blades assembling for 380 mm sweep exhaust fan complete all as specified.
M&L for Replacement of damaged/defective MS fan blades assembling for 300 mm sweep exhaust fan complete all as specified.
S&F in repairs exhaust fan louvers suitable to any sweep to out side building including making necessary arrangement like ladder/scaff holding etc and drilling of hole for fitting of exhaust fan louvre complete all as specified.
S&F in repair PVC insulated copper conductor multicore FRLS 3 core 6 sqmm for 1100V conforming to IS-694:2010 complete all as specified.
Surendra Singh (BID ID -3064490)
vinayandsons (BID ID -3069462)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .