Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹100.0 L
EMD Value
₹99,995
Closing Date
29 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Dy.Minicipal Commissioner - West Zone
Maintenance, Repairing, Renovation work for Different Municipal Bunglows, Municipal Schools, Municipal Schools, Anganwadi, Municipal Library, & Municipal Garden and Other Municipal Buildings in Navrangpura ward at West Zone.
256120
7/25-26 (T.N.38)
Open
Civil Works - Others
Works
Ahmedabad
4 documents required · 0 mandatory · 4 optional
₹2,400
Yes
Municipal Commissioner, Ahmedabad
₹99,995
Yes
20 Dec 2025
20 Dec 2025
20 Dec 2025
29 Jan 2026
20 Dec 2025
1. Name of Work : Maintenance, Repairing, Renovation work for Different
Municipal Bunglows, Municipal Schools, Municipal Schools,
Anganwadi, Municipal Library, & Municipal Garden and Other
Municipal Buildings in Navrangpura ward at West Zone.
2. Tender Estimated Cost : Rs:-
: 1% of the Tender Cost in the form of Rs. 99,995.00 (D.D. / Pay
3. Earnest Money
- Order / Local Micr Check/B.G.)
4 Tender Fee Rs : Demand Draft of Rs.2400.00
5 S.D. : 5 % of tender amount
6. Time-Limit : 12 months
7. Validity Period : 120 Days
(a) Eligibility Criteria Register “D” class in PWD in Govt. R&B/CPWD/AMC or
equivalent registration with any other state Govt. or
8. (i) Last Date of Submission of :
(ii) Mode of Sending : a) In Sealed cover in duplicate copies by Registered Post A.D,
or by Courier.or hand delivery
b) Tender sent by ordinary post will be rejected out right.
(iii) Description essential to :
a) Name of work, Tender Notice No. & Tender No.
be made on sealed cover b) Date of receiving tender by Corporations.
(iv) Mode of quoting rates in : The Price bid shall be submitted online only.
Schedule of Quantities and
Rates It shall not be submitted Physically.
9. Date of Opening : Dt.06-01-2026, 15:00 PM
10 Place of Submission & : Submission of EMD. Tender fee and other Documents during office
Opening of Tender hours: On date.06-01-2026 &12:00 pm West Zone, 2nd Floor, A.M.
Office, Dr. Ramanbhai Patel Bhavan, Usmanpura.Ahmedabad
Municipal Corporation, W.Z. Office, Ahmedabad-380013.
11 Penalty Due to Delay of work (1) Rs.1000/- per day (for tenders amounting upto 10 Lakhs), (2)
Rs.2500 per day (for tenders amounting above 10 Lakhs and upto
30 Lakhs), (3) Rs.5000 per day (for all tenders amounting above
Lakhs) but not more then 10% of bill
Defect Liability : As per ‘B-1 Form Close
Whenever a work is allotted by Engineering staff, whether minor or
major of part thereof of any amount, the contractor shall be bound to
start the works within 48 hours of intimation of work. Communication
done telephonically via SMS, Via Whatsapp and through letter / E-
mail shall be considered legal and binding for the same. Failure of
comply to start the works in 48 hours of intimation as above by
Time permitted to start parts
contractor the contractor shall be levied penalty of (1) Rs.1000/- per
day (for tenders amounting upto 10 Lakhs), (2) Rs.2500 per day (for
tenders amounting above 10 Lakhs and upto 30 Lakhs), (3)
Rs.5000 per day (for all tenders amounting above 30 Lakhs). Three
times failures by contractor shall make contractor responsible to be
black listed unless and otherwise justified properly in writing /
binding within 15 days of last notice of penalty.
The staff of the contractor shall wear safety jackets,
hoes, helmets etc. while on duty and any violation will attract
fine of Rs. 5,000/- for each incident.
Safety Failure to erect safety signage or trying to carry out he
works without proper precautions/safety measures as
equired will attract a fine of Rs. 5,000/- for each incident.
The contractor shall be responsible to make good and remedy at
his own expense any defect which may develop or may be noticed
before the period mentioned hereunder from the certified date of
completion, The within 15 days of receipt of the notice. In the case
of failure on the part of the contractor, the Engineer-in-charge may
rectify or remove or re-execute the work at the risk & cost of the
contractor. The Engineer-in-charge shall be entitled to appropriate
Defect &Liability Period the whole or any part of the amount of security deposit towards
14 the expenses, if any, Incurred by him in rectification, removal or re-
execution. The Defects Liability period shall be as under(a) for all
works costing upto Rs. 50,000 ( amount put to tender), the period
shall be 3 months from the certified date of completion.
(b) for all works costing more than Rs. 50,000 and upto Rs. 1 crore
(amount put tender), the period shall be 6 months from the
certified date of completion or one monsoon, whichever is later.
(c) for major projects costing more than Rs. 1 crore, the period
shall be 12 months from the certified date of completion which
should include one monsoon.
(d) For building works, the period specified in (a), (b) or (c) above
OR elapse of monsoon period following the certified date of
completion, whichever is later. For the purpose of deciding the
monsoon period, the 30th September may be treated as the last
Compensation for Delay 10% of Remaining work (As per Circular)
Whenever a work is allotted by Engineering staff, whether minor
or major of part thereof of any amount, the contractor shall be
bound to start the works within 48 hours of intimation of work.
Communication done telephonically via SMS, Via Whatsapp and
through letter / E-mail shall be considered legal and binding for
the same. Failure of comply to start the works in 48 hours of
Time permitted to start parts intimation as above by contractor the contractor shall be levied
16 of work penalty of (1) Rs.1000/- per day (for tenders amounting upto
Lakhs), (2) Rs.2500 per day (for tenders amounting above
Lakhs and upto 30 Lakhs), (3) Rs.5000 per day (for all tenders
amounting above 30 Lakhs). Three times failures by contractor
shall make contractor responsible to be black listed unless and
otherwise justified properly in writing / binding within 15 days of
last notice of penalty.
Addendum/Corrigendum If any Shall be Published 48 Hrs. Price To
the Final Submission Time And Date. The Same Shall From a part Of
Addendum/Corrigendum
17 Tender And The Same As to be Attached Along With The Tender
EPF Act As per Acoount Department circular no-37 Date:09/08/2018
GST will be paid extra by AMC/Authority at prevailing rate to the
Signature of contractor
Add. City Engg.(West Zone)
Name : Ahmedabad Municipal Corporation
Company's Seal :Date :
AHMEDABAD MUNICIPAL CORPORATION
ENGINEERING DEPARTMENT-WEST ZONE
Name of The Work:- Maintenance, Repairing, Renovation work for Different Municipal Bunglows, Municipal
Schools, Municipal Schools, Anganwadi, Municipal Library, & Municipal Garden and Other Municipal
Buildings in Navrangpura ward at West Zone.
Sr. No. Qty Description of Item Per Amount Rs.
Excavation for foundation up to1.5 m depth
including sorting out and stacking of useful
materials and disposing of theexcavated 115.92
stuff upto 50 Meter lead.(A) Loose or soft soil
1.5 to 3.0 mt.depth
Excavation for foundation for depth from 3.0 m to
5.0 m including sorting out and stacking of useful
c 50.00 materials and disposing off Cmt
the excavated stuff upto 50 Meter lead.(A) Loose
Excavation for foundation for depth from 1.5 m
to 3.0 m including sorting out and stacking of
useful materials and disposing off the excavated 270.83
stuff upto 50 Meter lead.(C) Hard Murrum
Filling available excavated earth (excluding
rock) in trenches, plinth, sides of foundations
2 50.00 etc. in layers not exceeding 20 cm. in Cmt
depth consolidation each deposited layer by
ramming and watering.
Filling in plinth with sand underfloors
3 50.00 including watering ramming, consolidating and Cmt
dressing etc. complete.
Filling in foundation and plinth with murrum or
selected soil in layers of 20 cm. thickness
including watering, ramming and 286.20
consolidating etc.
Providing and laying cement
concrete1:5:10 (1-Cement: 5- coarses
sand and:10-hand broken stone aggregates
40mm nominal size) and curing 2,492.51
complete excluding cost of formworkin (A)
Foundation and Plinth (upto 10 ton).
Providing and laying cement
concrete1:4:8 (1-Cement: 4- coarses
and:8-hand broken stone aggregates 40mm
nominal size) and curing complete 2,634.11
excluding cost of formworkin (A) Foundation
and Plinth (upto 10 ton).
Providing and laying cement concrete 1:3:6 (1-
Cement : 3- coarse sand : 6- hand broken stone
7 20.00 aggregates 40 mmnominal size) and curing Cmt
complete excluding cost of formwork in (A)
Foundation and Plinth..
Providing and laying cement concrete
1:3:6 (1-Cement:3-coarse sand:6-hand
broken stone aggregates 20mm nominal
size) and curing complete including cost of 4,006.15
formwork in (A) wall caps/coping (upto
Providing and laying cement concrete
work 1:2:4 ((1-Cement:2- coarse sand:4-graded
9 aggregates 20mm nominal size) curing
complete excluding cost of formwork
and reinforcement.
Foundations, footings, base or columns
and mass concrete 3,923.53
Slabs, landing, shelves, balconies, lintels,
b 20.00 beams, girders and cantilivers upto floor Cmt
Independent piers, columns, and pillars, upto
floor two level 4,012.47
Provdg. & laying cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone
aggregates 20 mm nominal size) for
reinforced concrete chhajjas not exceeding
10 cm. thickness upto floors two level
including finishing the exposed surfaces 6,487.07
with cement mortar 1:3 (1 cement : 3 find
sand) to give a smooth and even surface
centering and form work and curing
complete excluding cost of reinforcement.
Providing and laying controlled cement concrete
M.150 for curing complete excluding cost of
formwork and reinforcement for reinforced
concrete work in (A) Foundations, footings,Base 3,871.39
columns and Mass concrete
Providing and laying in position Ready
Mixed M-150 grade concrete for
reinforced cement conctere work, using
cement content as per approved Design Mix
manufactured in fully automatic
batching plant and transported to site of work
intransit mixer for a lead up to 10 kms
having continuous agitated mixer,
manufactured as per mix design of specified
grade for reinforced cement concrete work
11A 15.00 including pumping of R.M.C. from transit Cmt
mixer to site of laying, excluding the cost of
centering shuttering finishing and
reinforcement including cost of admixtures
inrecommended proportions as per IS:9103
to accelerate/ retard setting of concrete,
improve work ability without impairing
strength and durability as per direction of
theEngineer-in-charge. Without Fly Ash (Min
cement level as per latest IS456 shall be
Providing and laying in position Ready
Mixed M-200 grade concrete for
reinforced cement conctere work, using
cement content as per approved Design Mix
manufactured in fully automatic
batching plant and transported to site of work
intransit mixer for a lead up to 10 kms
having continuous agitated mixer,
manufactured as per mix design of specified
grade for reinforced cement concrete work
12 15.00 including pumping of R.M.C. from transit Cmt
mixer to site of laying, excluding the cost of
centering shuttering finishing and
reinforcement including cost of admixtures
in recommended proportions as per IS:9103
to accelerate/ retard setting of concrete,
improve work ability without impairing
strength and durability as per direction of
theEngineer-in-charge. Without Fly Ash (Min
cement level as per latest IS456 shall be
Providing and laying controlled cement concrete
M.200for curing complete excluding cost of
formwork and reinforcement for reinforced
concrete work in (A) Foundations, footings,Base 3,977.88
columns and Mass concrete
Walls, from top of foundation level upto floor two
Slabs,landing,shelves,Balconies Lintels, Beams,
c 10.00 Girders and Cantilever upto floor two level. Cum
Columns, Pillars posts and struts upto floor two
d 5.00 level. Cum
Staircases excluding landing upto floor two level
Vertical and Horizontial its upto floor two level.
Providing and laying in position Ready
Mixed M-250 grade concrete for
reinforced cement conctere work, using
cement content as per approved Design Mix
manufactured in fully automatic
batching plant and transported to site of work
intransit mixer for a lead up to 10 kms
having continuous agitated mixer,
manufactured as per mix design of specified
grade for reinforced cement concrete work
13 25.00 including pumping of R.M.C. from transit Cmt
mixer to site of laying, excluding the cost of
centering shuttering finishing and
reinforcement including cost of admixtures
in recommended proportions as per IS:9103
to accelerate/ retard setting of concrete,
improve work ability without impairing
strength and durability as per direction of
theEngineer-in-charge. Without Fly Ash (Min
cement level as per latest IS456 shall be
maintained) (Cement level 450 kg )
Providing and laying controlled cement concrete
M.250 and curing complete excluding the cost of
formwork and reinforcement for reinforced
concrete work in
Foundations, footings, Base of columns and
B 5.00 Mass concrete. Cu.M.
Walls, from top of foundation
C 5.00 level upto floor two leve Cu.M.
Slabs,landing,shelves,Balconies, Lintels, Beams,
D 5.00 Girders and Cantilever upto floor two level. Cu.M.
Columns, Pillars posts and
E 5.00 struts, upto floor two level. Cu.M.
Providing and laying in position Ready Mixed M-
300 grade concrete for reinforced cement
conctere work , using cement content as per
approved Design Mix manufactured in fully
automatic batching plant and transported to site
of work in transit mixer for a lead up to 10 kms
having continuous agitated mixer, manufactured
as per mix design of specified grade for
reinforced cement concrete work including
14 5.00 pumping of R.M.C. from transit mixer to site of Cum
laying, excluding the cost of centering shuttering
finishing and reinforcement including cost of
admixtures in recommended proportions as per
IS: 9103 to accelerate/ retard setting of
concrete, improve workability without impairing
strength and durability as per direction of the
Engineer - in - charge. Without Fly Ash (Min
cement level as per latest IS
shall be maintained)
Providing and laying in position Ready Mixed M-
350 grade concrete for reinforced cement
conctere work , using cement content as per
approved Design Mix manufactured in fully
automatic batching plant and transported to site
of work in transit mixer for a lead up to 10 kms
having continuous agitated mixer, manufactured
as per mix design of specified grade for
reinforced cement concrete work including
15 2.00 pumping of R.M.C. from transit mixer to site of Cum
laying, excluding the cost of centering shuttering
finishing and reinforcement including cost of
admixtures in recommended proportions as per
IS: 9103 to accelerate/ retard setting of
concrete, improve workability without impairing
strength and durability as per direction of the
Engineer - in - charge. Without Fly Ash(Min
cement level as per latest IS
shall be maintained)
Providing and Laying ordinary cement
concrete 1:2:4 (1-Cement 2-coarsesand: 4-
graded stone aggregates 20 mm nominal
size) and finishing smooth with curing etc.
complete including the cost of form work but 8,341.79
excluding the cost of reinforsement for R.C.C
work in (iv) Slabs having more than 13 cm and
upto 15 cm.thickness
Providing and Laying ordinary cement
concrete 1:2:4 (1-Cement 2-coarsesand: 4-
graded stone aggregates 20 mm nominal
size) and finishing smooth with curing etc. 7,380.23
complete including the cost of form work but
excluding the cost of reinforsement for R.C.C
work in (iv) Slabs having more than 8 cm and
upto 10 cm.thickness
Providing and laying ordinary cement concrete
1:2:4 (1- Cement 2- coarse sand : 4- graded
stone aggregates 20 mm nominal size) for R.C.C
lintel including finishing smooth with,curing etc. 8,634.45
complete including the cost of formwork but
excluding the cost of reinforcement.
Brick work using common burnt clay
building bricks having crushing strength
16 not less than 35kg./Sq.Cm.in foundation
and plinth in Cement Mortar1:5 (1-Cement
:5 - fine sand)
(A) Conventional (upto 10 ton)
Extra Rate for brickwork in Above Item for
17 super structure above plinth level upto floor
two level (B) Conventional
(A) Conventional (upto 10 ton)
C) above floor two level Item No. 2(6.13) (A) Per
c 10.00 Modular Floor Per
D) above floor two level Item No. 2(6.13) (B) Per
d 10.00 Conventional Floor Per
Half brick masonry in common brunt clay
building bricks having crushing strength not
less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (
1-Cement : 4 coarse sand ) in foundation 593.90
and Plinth conventional brickwork (up
to 10 ton) (B) Conventional
Extra for half brick masonry in super
19 10.00 structure above plinth level upto floor Smt
two level (B) conventional
Providing and laying Pre cast Light weight
concrete hollow core wall with hollow core
concrete unit of approved make & size of
mm thick, 600 mm wide and 2400 mm/
20 4.00 mm/ 2850 mm/ 3000 mm/ 3300 mm in legth Sqm
made from of controlled cement concrete
M20 having cube compressive strength not less
than 20 MP a jointing with high strength &
tensile adhesion non-shrink cementitious
joint compound /P.U. Foam. (Plaster not
Providing and laying Pre cast Light weight
concrete hollow core wall with hollow core
concrete unit of approved make & size of
mm thick, 600 mm wide and 2400 mm/
mm/ 2850 mm/ 3000 mm/ 3300 mm in legth
21 2.00 made from of controlled cement concrete Sqm
M20 having cube compressive strength not less
than 20MP a jointing with high strength &
tensile adhesion non-shrink cementitious
joint compound/ P.U.Foam. (Plaster not
Providing and laying Pre cast Regular
concrete hollow core wall with hollow core
concrete unit of approved make & size of
mm thick, 600 mm wide and 2400 mm/
mm/ 2850 mm/ 3000 mm/ 3300 mm in legth
22 4.00 made from of controlled cement concrete Sqm
M35 having cube compressive strength not less
than 35 MP a jointing with high strength &
tensile adhesion non-shrink cementitious
joint compound/ P.U.Foam. (Plaster not
Providing and laying Precast Regular
concrete hollow core wall with hollow core
concrete unit of approved make & size of
mm thick, 600 mm wide and 2400 mm/
mm/ 2850 mm/ 3000 mm/ 3300 mm in legth
23 4.00 made from of controlled cement concrete Sqm
M35 having cube compressive strength not less
than 35 MP a jointing with high strength &
tensile adhesion non-shrink cementitious
joint compound /P.U.Foam. (Plaster not
Providing form work in ordinary timber
planking so as to give a rough finish
including centering, shuttering, strutting and
propping etc. height of propping and
centering below supporting floor to celling not
exceeding 4 M & removal of the same for
in situ reinforced or plain concrete work upto
floor four level
Foundation, footings, bases of columns
etc. and mass concrete. 171.68
(B) Flat surfaces such as soffits of supspened
b 2.00 floors slabs Landings and the like. (1) Floors etc. Smt
upto 200 mm in thickness.
(B) Flat surfaces such as soffits of suspended
c 2.00 floor roof slabs Landings and the like. (2) Floors Smt
etc. above 200mm in thickness.
Vertical surface such as walls (any thickness)
d 2.00 partitions and the like including attached Smt
buttresses & string course & the like.
(ii) Sides And Soffits Of Beam, Haunchings
e 2.00 Cantilevers, Girders, Bressumers And Smt
Lintels Not Exceeding 1 M In Depth.
(G) Columns PillarsPosts and struts. (1) Square
Rectangular Polygonal in plan. 297.68
(2) Circular or curved in plan.
(H) (2) Sides and soffits of Beams Beam
h 2.00 Haunchings canti-levers Girders Bressumers Smt
and Lintels exceeding 1M.in Depth.
Providing and fixing 35 mm thick shutters for
Doors, windows and clear story windows
including anodised alluminium butt hinges
with necessary screws.
(A) Indian Teak Wood (ii) Fully Glazed.
(B) Indian Teak Wood (ii) Fully Panelled
(C) Indian Teak Wood (iii) Partly panelled
and partly glazed. 5,133.69
Providing and fixing 35 mm thick shutters for
Doors, windows and clear story windows
including black enamelled M.S.butt hinges
with necessary screws.
(A) Indian teak wood. (i) Fully
Panelled.(upto 10 ton) 5,285.45
(A) Indian teak wood. (ii) Fully
Glazed.(upto 10 ton) 4,595.06
(A) Indian teak wood. (iii) Partly panelled and
partly glazed. (upto 10 ton) 4,940.25
Providing and fixing 35 mm thick panelled,
glazed or panelled and glazed shutters for
Doors windows and clear story windows
including anodised alluminium But hinges
with necessary screws and indian teak wood
(A) Plywood sheet panels.
(B) Particle board panels
(C)Hard board panels.
(D) Asbestos sheet panels.
Providing and fixing 25 mm thick shutters
for cup boards etc. including black
28 10.00 enamelled M.S. butt hinges with necessary Smt
screws.(A) Indian teak wood. (i) Fully
Panelled. (upto 10 ton)
Providing and fixing 25 mm thick shutters for
cupboards etc. including anodised alluminium
butt hinges with necessary screws. (A) Indian 2,594.74
teak wood. (ii) Fully Glazed.
Providing and fixing 25 mm thick shutters for
cupboards etc. including anodised alluminium
butt hinges with necessary screws. (A) Indian 2,814.42
teak wood. (ii) Partly panelled and partly glazed.
Providing and fixing plain asbestos cement
sheet 6 mm thick in partitions including
fixing to fames with screws etc, complete with
50 mm x 12 mm Deodar wood beading 827.20
(Frames to be paid separately) (upto
Providing and fixing in partitions 4 mm thick
medium hard board of approved quality
including fixing to fames with screws etc
complete with 50 mm x 12 mm teak wood 516.60
beading (Frames to be paid separately)
25 mm thick wooden shelves supported
on 40 x 40 mm x 6 mm T or L iron brackets
31 10.00 fixed at suitable distances but not Smt
exceeding 75 cm. apart with Mango
wood or equivalent quality. (upto 10 ton)
40 mm thick wooden shelves supported
on 40 x 40mm x 6 mm T or L iron brackets fixed
32 4.00 at suitable distances not exceeding 75cm. Smt
Apart with Mango wood or equivalent
quality. (upto 10 ton)
Providing and fixing M.S. round or square bars
with M.S. flats at required spacing in wooden
frames of windows and clerestory 68.53
windows.(upto10 ton)
Providing and fixing M.S. grills of required
pattern to wooden frames of windows etc. with
M.S. flats at required spacings and
frame alround, square or round bars with round 100.17
headed bolts and nuts or by screws (A) Plain
Grill. (upto 10 ton)
Providing and fixing M.S. grills of required
pattern to wooden frames of windows etc. with
a 2.00 M.S. flats at required spacings and kg
frame alround, square or round bars with round
headed bolts and nuts or by screws (A)
Ornamental Grill. (upto 10 ton)
Providing and fixing glazed louvered
glass windows and ventilators with teak
35 2.00 wood frame 10 cm. x 7 cm. size including 3 Smt
coats of oil painting to wood work
etc.complete. (upto 10 ton)
Providing and fixing glazed louvered
glass windows and ventilators with teak
wood frame 10 cm.x7 cm. size including
coats of oil painting to wood work 4,332.47
etc.complete.with wooden louvers plank 12mm
thick (upto 10 ton)
Providing and fixing 35 mm thick shutters for
Doors, windows and clere story windows
including Indian teak wood frames 10 cm x 7 cm.
37 10.00 size including anodized alluminium fixtures Smt
and fastenings including primer coat of
approved quality and two coats of oil painting
etc, complete.(ii) Fully Glazed.
Providing and fixing 35 mm thick shutters for
Doors, windows and clere story windows
including Indian teak wood frames 10 cm x 7 cm.
38 4.00 size including black enamelled iron oxidixed Smt
fixtures and fastenings including primer coat
of approved quality and two coats of oil
painting etc, complete.(ii) Fully Panelled.
Providing and fixing 35 mm thick shutters for
Doors, windows and clerestory windows
including Indian teak wood frames 10 cm x 7 cm.
size including anodized alluminium fixtures
and fastenings including primer coat of approved 3,557.15
quality and two coats of oil painting
etc, complete. (iii) Partly panelled and partly
Providing and fixing 30mm thick FACTORY
SOLID BOTH SIDE PRELAM PANEL PVC
SHUTTER consisting of frame made out of
M.S.tubes of 19 gauge thickness and size of
19mm x 19mm for stiles, top and bottom rails.
M.S. frame shall have a coat of steel primer of
and manufactures. M.S frame covered with 5mm
thick heat moulded prelim PVC ‘C’ channel of siz
30mm thickness, 70 mm width of which 50mm
shall be flat and 20mm shall be tapered in
degree Angle on either side forming stiles, and
5mm thick, 95mm wide pream PVC sheet out of
which 75mm shall be flat and 20mm shall be
tapered in 45 degree on the inner side ot form
top and bottom rail and 115mm wide prelim PVc
39 8.00 sheet out of which Smt
75nmm shall be flat and 20mm shall be - 75nmm
shall be flat and 20mm shall be tapered on both
side to form lock rail, Top, bottom
and lock rails shall be provided either side of the
panel. 10mm (5mm x 2) thick 20mm wide cross
PVC sheet shall be provided as gap insert for
top rail and bottom rails. Panelling of 5mm thck
both side prelim PVC sheet to be fitted in the
M.S. frame welded,sealed to the stiles and rails
with 7mm (5mm + 2 mm) thick x 15mm wide
PVC sheet beading on inner side, and joined
solvent cement adhesive. An additional 5mm
thick PVC strip of 20mm width is to be stuck on
the interior side of the ‘C” chanel using PVC
solvent adhesive etc. complete as per direction
of Engineering in charge, manufacture’s
specification and rawing.
Providing and fixing in position collapsible
steel shutters with vertical channels 20 x
10 x 2 mm braced with flat iron diagonal 20 x6
mm size with top and bottom rails T iron 40 x
40 8.00 40 x 6 mm with 38 mm dia steel pulleys Sq.M.
complete with bolts, units, locking
arrangements, stoppers, handles, including
a priming coat of red lead paint & approved
Providing and fixing 1 mm thick M.S. sheet
sliding shutters with frame and diagonal
braces of 40x40x6 mm angle iron, 3.15 mm
M.S.gusset plates at Junctions and corners
41 2.00 mm dia. pulley, 40x40x6 mm angle and Sqm
T-iron huide rail at top and bottom
respactively with handles, stoppers and locking
agangement etc, including applying a
priming coat of red lead paint. (upto 10 ton)
Providing and fixing rolling shutters of approved
make made of 80 mm wide M.S.laths
inter-locked together through their entire length
and jointed together at theends by end locks
mounted on specially designed pipe shaft
42 7.00 with bracket plates, guide channels Sqm
and arragements for inside and out side
locking with push-pull operation including
the cost of hood cover and spring etc.
complete. (A) Shutters having width below
Providing and fixing rolling shutters of approved
make made of 80 mm wide M.S.laths
inter-locked together through their entire length
and jointed together at theends by end locks
mounted on specially designed pipe shaft
a 2.00 with bracket plates, guide channels Smt
and arragements for inside and out side
locking with push-pull operation including
the cost of hood cover and spring etc.
complete. (A) Shutters having 3.5 M. &
Providing and fixing extruded aluminum window
having extruded aluminum Colour Powder
Coated section frame main outer size 127mm x
1.35mm ,@ Wt.1.384 Kg/mt,horizontal Four
track member size 122.20mm x 31.75mm x
1.10mm @ Wt. 1.205 Kg/mt,vertical member of
size 122.20mm x 31.75mm x 1.50mm ,@ Wt.
43 10.00 1.398 Kg/mt with sliding shutters of horizontal Smt
member size 40mm x
18mm x 1.29mm @ wt.of 0.456Kg/mt,vertical
member of size 40mm x 18mm x 1.29mm @
wt.of 0.456Kg/mt,@ with 5 mm thick transparent
bronze colour tinted float glass with powder
coated aluminum fittings and fixtures and
transparent silicon sealant glass fixing to frame
as per details etc complete for window.
Providing and fixing window having extruded
aluminum Colour anodized section frame main
outer size 63.50 x 38.10 x 1.95 mm,@ Wt
Kg / Rmt, horizontal two track member size
Kg/mt, vertical member of size 61.85 mm x
31.75mm x 1.30 mm @ wt.of 0.659 Kg/mt with
sliding shutters of horizontal member size 40mm
x 18mm x 1.29mm @ wt.of 0.456Kg/mt, vertical 1,696.73
member of size 40mm x 18mm x 1.29mm @
wt.of 0.456Kg/mt, @ Wt. 0.457 Kg/mt with 5 mm
thick transparent bronze colour tinted float glass
with powder coated aluminum fittings
and fixtures and transparent silicon sealant glass
fixing to frame as per details etc complete for
Providing & Fixing in position Alluminium
vents with frame using approved anodised
extruded alluminium section as approved by
Engg. In charge.(Jindal alluminium)
45 10.00 units equivalent Approved Rate)Frame section Sq. M.
of 63.50 x 38.50 mm. (wt. 0.68Kg/Rmt)
incl. Providing & Installing 5 mmthick approved
color Acrylic sheet of standard quality
Providing and fixing standared extruded of
alluminium section of size 63 mmx38.10
mmx1.2 mm (Jindal Section:2434, @
46 10.00 Wt.0.643 Kg/mt) with colour anodized Sq. M.
alluminium frame for ventilation with 5 mm
thick frosted glass as details etc complete for
Providing and fixing standared extruded of
alluminium section of size 63.50 x 38.10 x
mm,@ Wt 1.094Kg / Rmt with colour Powder
Coated alluminium frame with 5 mm thick 1,509.90
transparent bronze colour tinted float glass as
details etc complete for Fix Partition
Providing and laying 40 mm thick marble
chips flooring rubbed and polished (I.E.terrazo)
to granolithic finish with under layer 30 mm thick
cement concrete1:2:4 (1-Cement: 2-coarse
sand: 4-graded stone aggregate 10 mm
and down gauge) and to player 10 mm thick
48 1.00 with white, black or white and blak marble cihps Sqm
of required sizes from 1 mm to 4 mm nominal
size laid in cement marble powder mix 3:1 (3-
Cement:1-Marble powder by weight) in
proportion of 4:7 (4- Cement: 7-marble
chips by volume) (C) Medium Shade
pigment with approx 50% white cement
and 50% ordinary cement (In top layer only)
Providing and laying marble chips skirting
(Terrazo) or dedo rubbed, and polished to
Granolithic finish to player 6 mm white, black
or white and black marble chips of size
from smallest to 4 mm nominal size laid in
cement marble powder mix 3:1 (3-Cement: 869.40
1 marble powder by weight) in proportion of
4:7 (4-cement marble powder mix: 7-marble
chips by volume) (B) Light shade pigment with
white cement (In top layer only)
Providing and laying white glazed tiles 6mm
thick in flooring treads of steps and landing laid
50 2.00 on a bed of 12mm thick cement mortar 1:3 (1- Sq.M.
cement : 3-coarse sand ) finishing with flush
pointing in white cement.
Providing and laying Ceramic tiles 6 mm thick
in flooring treads of steps and landing laid on a
51 10.00 bed of 12 mm thick cement mortar 1:3 (1- Sq.M.
cement :3-coarses and) finishing with flush
pointing in white cement. (upto 10 ton)
Providing & Fixing 2mm Aluminium / 4mmACP
sheeting fixed with Type-11 Class-C High
Intensity Grade Sheeting as per IRC 67 :
reflective sheeting of size including lettering and 5,832.20
Providing and laying Vitrified tiles 8 to 10 mm
thick, 36''x36'' in flooring treads of steps and
landing laid on a bed of 12 mm thick
cement mortar 1:3 (1-cement:3-coarses and) 1,469.91
finishing with flush pointing inwhite cement. (upto
Providing and laying Vitrified tiles 8 to 10 mm
thick, 24''x24'' in skrting risers of steps and dedo
54 30.00 on 10 mm thick cement plaster 1:3 (1- Sqm
cement: 3-coarse sand) and jointed with
white cement slurry (upto 10 ton)
Providing and laying Vitrified tiles 8 to 10 mm
thick, in skrting risers of steps and dedo on
55 20.00 mm thick cement plaster 1:3 (1-cement:3- Sqm
coarse sand) and jointed with white cement
slurry (upto 10 ton)
Providing and laying 24" x 24" vitrified
Tiles 8 to 10 mm th. Double Charged
gloosy/ Matt of Approved make as approved
by Adl.C.E. / consultants in flooring over
mm thick cement mortar 1:6 (1 cement : 6 1,527.00
coarse sand)on new surface& jointed with
colour cement slurry incl with flush
pointing & cleaning the surface etc. comp.
Providing and laying 24" x 24" vitrified
to 10 mm th.Double Charged Gloosy /
Matt tiles of Approved make as Approved
by Adl.C.E. / Consultants for upto 10 cm high
57 10.00 skirting as approved by Engineer in charge Rmt
over 10 mm thick cement mortar 1:6 (1 cement
: 6 coarse sand)on new surface& jointed with
colour cement slurry incl with flush pointing &
cleaning the surface etc. comp.
Providing and laying polished Kota stone slab
flooring over 20 mm (Average) thick base
of cement mortar 1:6 (1-cement:6-coarses
and) or L.M.1.1.5 (1-Lime putty:1.5-
58 15.00 coarses and) laid over and jointed with grey Sq.M.
cement slurry mixed with pigment to match
the shade of slab including rubbing and
polishing etc. complete. (A) 25 mm thick (upto
Providing and laying marble stone slab flooring
over 20mm (average)base of cement mortar 1:6
(1-cement : 6 coarse sand) or L.M. 1:1.5(1- lime
putty : 1.5 - coarse sand) laid and jointed with 2,194.63
gray cement slurry including rubbing and
polishing complete. (A) Marble slab 25mmthick
Providing and laying polished Kota stone slab
flooring over 20 mm (Average) thick base
of cement mortar 1:6 (1-cement:6-coarses
60 2.00 and) or L.M.1.1.5 laid over and jointed with Sq.M.
grey cement slurry including rubbing and
polishing etc.complete. (B) 30 mm thick
Providing and laying polished kota stone slab
mm thick in risers of steps, skirting Dedo and
pillars laid on 10 mm thick cement mortar 1:3 (1-
61 2.00 Cement :3 coarses and) and jointed with Sq.M.
gray cement slury mixed with pigment to
match the shade of slab including rubbing
and polishing etc.complete. (upto 10 ton)
Providing and laying cement concrete
flooring 1:2:4 (1-cement: 2-coarses and:4-
62 2.00 graded stone aggregate 20mm nominal size) Sq.M.
laid in one layer and finished with a floating
coat of neat cement. (A) 40mm thick. (upto
Providing and laying cement concrete
flooring 1:2:4 (1-cement: 2-coarse sand:4-
graded stone aggregate 20mm nominal size)
laid in one layer and finished with a floating 348.08
coat of neat cement. (B) 50mm thick. (upto
Providing and fixing pre-cast concrete
kerb stone of gray cement based
concrete block 30 cm length, 30 cm height and
15 cm thick of M200 grade concret as per
approved design and including excavation 376.43
for fixing in proper line and level, filling the joint
with C:M 1:3 (1 cement :3 fine sand) etc
complete. (upto 10 ton)
Providing and fixing pre-cast Rubber Dye / steel
Dye inter locking concrete block 60mm thick
with grade of concrete M300 pnumatic
compressed / vibrated mechanically and as per
65 2.00 approved design Confirming to IS 15658 : 2006 Smt
including 35 mm Sand layer for levelling
and filling the joint with sand in proper line and
level as per guidlines of IRC : SP 63-2018 etc.
Providing and laying broken china mosaic
flooring for terrace using 12 mm to 20 mm
broken pieces of glazed tiles to be laid over
cement mortar 1:3 to plain or slope and to be
66 5.00 tempered to bring mortar creme out upto Sqm
surface using white cement including
rounding off junctions and extending them
up to15 cm along the wall, clearing with
water and oxalic acid etc.asdirected.
Providing and laying coloured glazed
tiles of the size 300 mmx200 mmx8
mm/300 mmx450 mmx8 mm in skirting,
risers of steps and dedo on 10 mm. thick 1,426.95
cement plaster 1:3 (1cement: 3 coarse
sand) & jointed with white cement slurry.
Providing corrugated G.I. sheet of class-3
roofing fixed with glavanished iron J
or L Hooks, Bolts and nuts 8 mm diameter
68 5.00 with bitumen and G.I. limpet washer or G.I. Sqm
limpet washer. filled with white lead complete
excluding the cost of purlins, Rafters and
Trusses. (1) 0.80 mm thick sheet.(up to10 ton)
Providing ridges or hips 600 mm over allin
69 2.00 plain G.I. sheet class-3 fixed with G.I. J or L Sqm
Hooks and nuts 8 mm dia G.I. Limpet and 635.58
bitumen washer complete. (1)
Providing and fixing 150 mm wide 450 mm over
all semi circular plain G.I.sheet class-3 gutter
with Iron brackets 40 mmx3 mm size Bolts,
Nuts, washers etc. including making 555.71
necessary connection with rain water pipes. (i)
Providing and fixing five courses water
profing treatment with bitumen felt
consisting of second and fourth course of
blown/ bitumen or/and residual bitumen
applied hot at 1.2 kg.per Sq.M.of area for
each course and first course with fibre
base bitunen saturated under lay type land third
course with fibre base self finished felt type 2 466.84
grade 1 and fifth and final course of stone grit
6 mm and down size or pea sizes gravel
Cu.Metre/Sq.metre preparation of surface
excluding grading complete. (upto 10 ton)
Providing and fixing on wall face C.I. Rain
water pipe including filling the joints with spun
72 1.00 yarn soaked in neat cement slurry and Rmt
cement mortar 1:2(1- Cement : 2-fine
sand) (A) 75 mm dia.
Providing 15 mm thick cement plaster in
single coat on Rough (Similar) side of single or
73 2.00 half brick walls for interior plastering up to Sqm
floor two level and finished even and smooth
in (i) Cement mortar 1:3 (1-cement :3-sand)
Providing 20mm thick sand faced cement plaster
on walls upto height 10 metres above ground
level consisting of 12mm thick backing coat of
C.M. 1:3 (1-cement : 3-sand) and 8mm thick 215.78
finishing coat of C.M. 1:1 (1-cement : 1-sand)
Colour washing with lime on wall surface
(two coats) over and including a primary
coat of white washing to give an even shade
after through brooming the surface to remove 12.29
all dirt, dust, mortar drops and other foreigh
Removing dry or oil bound distemper
by a washing and scraping and sand
papering the wall surface smooth including 11.19
necessary repairs to scratches complete.
Distempering with dry distemper of approved
brand and manufacture (two coats) and of
required shade on wall surfaces of given an
77 5000.00 even shade, over and including a priming Sqm
coat of whiting after thoroughly brooming
the surface free from mortar dropping and
other foreign matter.
Extra Coat for Above Item over above for
77 a 5000.00 every subsequent coat of approved brand Sqm
and manufacture.
Distempeing (Two coats) with oil bound
distemper of approved brand and
manufacture and of required shade on wall
surfaces to give an even shade, over and
including a priming coat with distemper
78 5000.00 primer of approved brand and Sqm
manufacture after thoroughly brushing the
surface free from mortar dropping and other
foreign matter and also including
preparing the surface even and sand papered
Extra Coat for Above Item over above for
79 5000.00 every subsequent coat of approved brand Sqm
and manufacture.
Wall painting (two coats) with plastic
emulsion paint of approved brand and
manufacture on undecorated wall surface to
give an even shade including throughly brushing 78.44
the surface free from mortar droppings and
other foreign matter and sand papered smooth.
Extra over item for every sub sequent coat of
81 5000.00 wall painting with plastic emulsion paint of Sqm
Extra over item for painting with plastic emulsion
81 a 5000.00 paint of approved brand on ceilings and sloping smt
Applying priming coat over new steel and
other metel surface after and including
preparing the surface by throughly cleaning,
82 1500.00 oil, grease, dirt and other foreign matter Sqm
and scoured with brushes fine steel wood,
scrapers and sand paper with ready mixed
priming paint brushing red lead.
Painting two coats (excluding priming
coat) on new steel and other metal surface
with enamel paint, brushing, interior to give
an even shade including cleaning the surface 86.94
an even shade including cleaning the surface
of all dirt, dust and other foreign matter.
Painting one coats (excluding priming coat)
on previously painted steel and other metal
84 2000.00 surface with enamel paint, brushing to give Sqm
an even shade including cleaning the surface of
all dirt, dust and other foreign matter.
Extra over item for 83 & 84 every sub sequent
coat of paint. 50.40
Painting two coats (excluding priming
coat) on new steel and other metal surface
86 2000.00 with synthetic enamel paint, brushing to give Sqm
an even shade including cleaning the
surfaceofalldirt,dust and other foreign matter.
Painting one coats (excluding priming coat)
on previously printed steel and other metal
87 2000.00 surface with synthetic enamel paint, brushing to Sqm
give an even shade including cleaning the
surface of all dirt, dust and other foreign matter.
Extra over Above item for 86 & 87 for every
sub sequent coat of paint. 43.47
Painting two coats (excluding priming
coat) on external surface of new rain water,
soil, waste and vent pipes and fittings with
89 2000.00 ready mixed bituminous brushing, black, anti Sqm
corrosive to give an even shade including
cleaning of all dirt, dustand other foreign
matter.(75 mm dia)
Painting two coats (excluding priming
coat) on external surface of new rain water,
soil, waste and vent pipes and fittings with
90 2000.00 ready mixed bituminous brushing, black, anti Sqm
corrosive to give an even shade including
cleaning of all dirt, dust and other foreign
matter.(100 mm dia)
Painting two coats (excluding priming
coat) on new wood and wood based surface
with enamel paint, interior to give an even
91 2000.00 shade including cleaning the surface of Sqm
all dirt, dust and other foreign matter sand
papering and stopping. (a) Ready mixed paint
brushing wood primier pink.
Painting one coats (excluding priming coat)
on previously painted wood and wood based
surface with enamel paint, to give an even shade
including cleaning the of all dirt, dust and other 40.17
foreign matter.(b) Ready mixed paintbrushing
priming for enamel
Extra over Above item for 91 & 92 every sub
sequent coat of paint. 36.39
Painting two coats (excluding priming coat) on
wood and wood based surface with ready mixed
94 2000.00 paint, brushing, oil, gloss, semi gloss to give and Sqm
even shade including cleaning of all dust, dirt
other foreign matter sand papering and stopping.
Finishing wall with weather proof exterior
emulsion paint on wall surface (two coats)
to give an required shape even shade after
thoroughly brushing the surface to remove all 113.40
dirt, and remains of loose powdered
materials.etc complete
Applying two coats of putty & two coats of primer
of approved brand and manufacture on new wall
surface to give an even shade including
96 5000.00 thoroughly Sqm
brushing the surface free from mortar dropping
other foreign matter and sand papered smooth.
Painting two coats (excluding priming
coat) on new wood and wood based surface
with enamel paint, interior to give an even
shade including cleaning the surface of 87.11
all dirt, dust and other foreign matter sand
papering and stopping.
Writing letter or figures on any surface
with black japan paint (stops, comas, per letter
98 10.00 hyphens and the like not to be measured per
and paid for separately) (i) Block Cm/Ht
(Letters/Figures) (Per 10 Letter pet CM.HT)
Extra over items for using thick white paint per letter
instead of black japan paint. (i)Block per
(Letters/Figures) Cm/Ht
Polishing with french polish on new wood and
wood based surface to give an even
surface including cleaning, the surface of all dirt,
100 10.00 dust and Smt
sand papering smooth and including a coat of
Extra over items for using thick white paint
instead of black japan paint. (ii) Indian
101 10.00 0.07 perCm/Ht
(Letters/Figures)
Painting lines, deashes, arrows, letters etc
on roads, Air fields and like in two coats with
102 10.00 road marking paint, brushing including Sqm
cleaning the surface of all dirt, dust and other
foreign matter. (i)Over 10cmi n width
Painting lines, deashes, arrows, letters etc
on roads, Air fields and like in two coats with
103 10.00 road marking paint, brushing including Rmt
cleaning the surface of all dirt, dust and other
foreign matter.(ii) Upto 10 cm in width
Painting lines, deashes, arrows, letters etc on
roads, Air fields and like in one coats with road
104 10.00 marking paint, brushing including cleaning the Sqm
surface of all dirt, dust and other foreign matter.
(i) Over 10cm in width
Painting lines, deashes, arrows, letters etc
on roads, Air fields and like in one coats with
105 10.00 road marking paint, brushing including Sqm
cleaning the surface of all dirt, dust and other
foreign matter. (ii) Upto 10cm in width
Demolition including stacking of serviceable
106 10.00 materilas and disposal of unserviceable Cu.M.
materials with all lead and lift. (i) R.C.C. work
Demolition of Brick work and stone masonry
including stacking of serviceable materil as
and disposalof unserviceable materials with all 544.95
lead and lift.(ii) In Cement Mortar.
Demolition of terrace including stacking of
serviceable materilas and disposal of
unserviceable materials with all lead and lift.(i) 63.00
Brick tile covering.
Dismentaling tiled of stone floors laid in mortar
including stacking of serviceable materil as and
disposal of unserviceable materials with all 47.25
Dismentaling of sheet roofing including
ridges, Hips, Valleys, Gutters etc. stacking of
109 2.00 serviceable materil as and disposal of Sqm
unserviceable materials with all lead and
lift.(i) G.I.sheet roofing.
Dismentaling of sheet roofing including
ridges, Hips, Valleys, Gutters etc. stacking of
109 A 2.00 serviceable materil as and disposal of Sqm
unserviceable materials with all lead and
lift.(i) A.C. sheet roofing.
Dismentling steel work including
110 2.00 distempering and stacking the materials Kg.
with all lead and lift.
Dismentling doors, windows, ventilators
etc. (wood or steel) shutters including
chowkhats architraves, hold fasts and other
attachment etc. complete and stacking the 185.85
material within all lead and lift.(i) Not exceeding
3 Sq.M. in area.
Dismentling doors, windows, ventilators
etc. (wood or steel) shutters including
chowkhats architraves,hold fasts and other
attachment etc. complete and stacking the 248.85
material with in all lead and lift.(ii) Exceeding
Dismentling barbed wire in fencing including
making rolls and also including dismentling
fencing posts including all earth work concrete in
base and making good the disturbed
ground stacking useful materials as 66.15
directed and disposing as directed
and disposing of the unserviceable
materials with all lead and lift.
Dismentling C.I. pipes G.S.W. pipes abd
A.C. rain water pipes with fittings and clamps
including stacking the materials with all lead and 74.03
lift (for any dia, of pipe)
Dismantling santtary fittings like wash basin .
W.C. pan Indian and Europe an type, flushing
tank etc. including stacking the materials 401.63
with all lead and lift
Scraping oil paint from steel and other metal
116 10.00 surface and making the surface even Smt
(with Hand Scraping.)
Removing and scraping of old deteriorated
plaster of any thickness from wall /
R.C.C member including stacking of
serviceable material and disposal of 19.38
unserviceable from site of work with all lead
Providing and fixing M.S. fan clamps of
shape and size as specified in existing
R.C.C. slab including cutting chase and making 168.53
Cutting out cracks of roof terrace to V-
section, cleaning out, wetting, grouting with
cement and sand slurry 1:3 (1-cement 3-sand 64.58
) (upto 10 ton)
Cutting out cracks roof terrace to V-Section
cleaning out and filling solidly with a hot
mixture of bitumen and clean dry sand (1:1 75.29
by weight) (up to 10 ton)
Providing & Fixing in position Alluminium
doors with frame using approved quality
anodised extruded alluminium section as
approved by Engg.in charge(Jindal
alluminium)(a) Frame sections 101.6x44.45
mm (b) Shutter bottom vertical & top
section 83.5x44.45 (wt.1.31 kg/mt.)(at
kg/mt) (c) Shutter bottom section at
114.3x44.45 mm at (1.37 kg/mt) Shutter middle 2,900.00
section at 100x44.3 wt.(1.37 kg/mt)
incl.providing & installing 5 mm thick
approved color Acrylic sheet of standard
quality fixed with glazing chips on upper
pannel & Laminated sheet on lower pannel
(wtt.0.13 kg/Rmt) etc.comp.as direction of
engg.in charge.(N.S.)
Providing & Fixing in position Fully Panelled /
Partly Panelled Partly Glazed / Fully Glazed
Alluminium doors with frame using approved
quality anodised extruded alluminium
section of 1.5 mm thickness as approved by
Engg. In charge.(Jindal alluminium )(a) Frame
sections 101.6x44.45 mm b) Shutter vertical
& top section 83.5x44.45 (wt.
kg/mt.)( at 1.31 kg/mt) © Shutter bottom 4,583.00
section at 114.3 x44.45mm at ( 1.37 kg/mt )
Shutter middle section at 100x44.3 wt. (1.37
kg/mt ) incl. providing & installing 5 mm thick
Glass of standaed quality fixed / 12 mm
thick Laminated sheet with glazing chips (wt.
0.13 kg/ Rmt) in panels etc. comp. as per
Detail Given & direction of engg.in charge.
Providing & Fixing in position Alluminium
window 2/3/4 track sliding / fix type with
frame using approved anodised extruded
alluminium section of minium thickness of
123 1.00 mm as approved by Engg. In Sq. M.
charge.(Jindal alluminium) units
equivalent. including P/F installing 5 mm thick
clear/tinted Glass of standard quality
Providing and fixing standared extruded of
alluminium section of size 63.50 x 38.10 x
mm,@ Wt 1.094Kg / Rmt with colour Powder
Coated alluminium frame with 1,815.14
5 mm thick transparent bronze colour tinted float
glass as details etc complete for Fix window.
Providing and fixing of Ridge flashing
for roof panel shall be made out of
mm thick pre coated GI sheet. The Pre
coatedsheet shall be of minimum 240 mpa
steel grade confirming to IS 14246:1995 and
shall have zinc coating of minimum 120 gsm
as per IS:277:1992, 5-7 microns epoxy
primer on both side of the sheet and
polyester top coat 15-18 micron. The PP GI 458.85
Sheet shall have plastic protective guard film
of minimum 25 microns to avoid scratches
during transportation. The ridge shall be fixed
to the steel members by poprivetor self
drilling/self stitching fastners @ maximum
450mm c/c along length of capping/flashing etc
Supplying and fixing vinyl flooring over the
surface having 1-2 mm thickness as per
directed by engineer incharge etc 963.00
as completed (N.S.)
Providing and laying 15mm bamboza
wooden flooring as per architect's drawing
with all necessary details as directed by
127 2.00 the project consultants. Use underlay for Smt
better result as per Detail specifications and
directed by the project consultants. (N.S.)
Approved Rate )
Providing and fixing 1.20 Metre high
fencing with 2.0 Metre long M.S. Angle posts
40 mm x 40 mm x 6 mm and oil painting
coats fixed at 2.5 Mt, C/c. with five
Horizontan lines and two diagonals of
galvanised steel barbed wire weighting 9.38 385.40
Kg. per 100 Metre, strained and fixed to posts
with G.I, staples including fixing the posts in
ground with 0.5 M x 0.5.M x 0.5 M. block in
C.C 1:5:10 etc complete.
Dismentling barbed wire in fencing including
making rolls and also including dismentling
posts including all earth work concrete in base
129 2.00 making good the disturbed ground stacking Rmt.
materials as directed and disposing as directed
disposing of the unserviceable materials with all
Constructing a sink (chowkedi) with C.C.
1:2:4, 12 cm. thick over B.B. masonry in C.M,
(1:6) in front and dwarf wall 1.0 Mt. high and
cm. thick cement plaster to masonry / in 2,235.66
C.M.1:3) and cement concrete flooring in 1:2:4:
mix 5cm.dia.drain pipe etc.complete.
Constructing a cooking platform 60 cm. width
and 70 cm high resting on B.B. Masonry walls
23 cm. thick in C.M. (1:6) with (i) Fixing
131 2.00 or precast R.C.C. 1:2:4) 8 cm. thick slab with Rmt
marble chips set in C.M. (1:6) (6 mm thick
terrazo) with plastering on exposed faces
walls in C.M. (1:4) etc complete.
Making 15 mm groove in RCC work on road and
filling it with polysulfied selant and finished it
good incl. all all labour charges etc. comp as 30.00
P/A Tremix with dewartering machine
and floater machine on constructed CC work
for finishing the surface as per
133 2.00 requirement. The rate including all machinaries, Sq.M.
labor, loading, unloading,
transportaion etc complete as per direction
given by engineer incharge.
Carring out timber treatment to all wood work
including drilling holes and spraying oil based
chemical solution on surface of timber work for
termite control including labour and material
etc. complete. Using Chlordene 20 EC.
As Per 6113_part III Consentration
134 2.00 Weight1.00 percent is recommended one litre Smt
chemical emulsion dillute with 9 liter of
kerosene precent concentration. Total
dillute concrentration will be 10 litre
inclusive of the litre chemical emulsion
appication 0.75 / Litre chemical per one
Sqmt printed two coat wood surface.
Applying general insecticide pest control
treatment to floors, cup boards etc
including labour material etc. complete.
Using Heptachloride 20 EC. As Per
6113_pests Consentration Weight
135 2.00 percentis recommended one litre chemical Smt
emulsion dillute with 39 liter of water will give.
Total dillute concrentration will be 40 litre
inclusive of one litre chemical emulsion
appication 0.5 Litre chemical / Sqm of
surface is recommended as per I.S
Carring out plinth treatment to post construction /
existing structure by spraying chemical
solution for termite control treatment
including labour and material consist ment
with I.S. specification. Using Chlordene
and Chior purfiles 20 EC. As Per
6131_paret-II Consentration Weight on percentis 104.90
recommended i.e one litre 20 EC chemical
emulsion with 19 liter give 1% concrentration
inclusive of one litre chemical emulsion
appication attherate of 5 Litre chemical /
Sqm of surface is recommended as per I.S
Carrying out wall treatment for termite
control including spraying with chemical
solution in oil base (0.5 Lit./Sq.M.) including
labour and material Using Hepachlor
concentration 20 EC. As Per
IS.6316_paret-II Consentration by Weight
137 2.00 0.50 percentis recommended i.e Smt
one litre chemical emulsion dillute with
liter go fIS concrentration total dillite
concentration will be 40 litre inclusive of one
litre chemical emulsion appication at the rate
of 7.5 Litre chemical / Sqm of surface is
recommended as per I.S
Providing erecting and fixing double
coated Syntex PVC.(ISI) water tank of
138 500.00 required capacity each with all necessary Litre
fittings and connection etc. complete on
Providing and fixing to wall, ceiling and floor
galvanised Mild steel tubes (Medium
139 grade) of the following nominal bore, tube
fitting and clamps including making good the wall
ceiling and floor.
(A) 15mm (upto 10 ton)
(B) 20mm (upto 10 ton)
(C) 25mm (upto 10 ton)
(D) 32mm (upto 10 ton)
(E) 40mm (upto 10 ton)
(F) 50mm (upto 10 ton)
Providing and laying in trenches galvanised
mild steel tubes (Midium grade) of the
following nominal bore, and tube fitting
(Earth work in trenches to be measured
and paid for separately)
(A) 15mm (upto 10 ton)
(B) 20mm (upto 10 ton)
(C) 25mm (upto 10 ton)
(D) 40mm (upto 10 ton)
(E) 65mm (upto 10 ton)
(H) 80mm (upto 10 ton)
Making connection of galvanised Mild steel
distribution branch with galvanised mild steel
141 1.00 main 50 mm to 80 mm nominal bore by Each
providing and fixing tee including cutting and
threading the pipes complete.
Providing and fixing to wall ceiling and floor
Kg.F/Cm2 working pressure poluthene pipes
of the following out side Dia. Low
142 densidy, complete with special falnge
compression type fittings,wall clips
etc.including making good the wall ceiling and
Providing and fixing to wall ceiling and floor
10.0Kg.F/Cm2 working pressure polythene
pipes of the following out side Dia.
143 Low densidy, complete with special falnge
compression type fittings, wall clips etc.
including making good the wall ceiling and
Providing and fixing cast iron (Spun)
Nahni trap of the following nominal diameter
of self cleaning design with C.I. screaed
down or higned grating including cost of 600.08
cutting and making good the walls and floor
mm inlet and 50 mm outlet.(C)100mm dia.
Providing and fixing water closet squatting
Pan (Indian type W.C.Pan) size
mm (Earth work, bed concrete, foot rest and
trap to be measured and paid for separately) 926.10
(A) Vitreous China. (I)Long pattern = White
Provdg. & fixing wall mounted White /
Color Vitreous China European water
closet with integral P trap of "Cera" -
Clair Series or equivalent incl. seat cover , 4,250.00
Chair Bracket etc. complete as per direction of
engg. In charge.(N.S.)
Providing and fixing wsh down water
closet (Europe an type, W.C.Pan) with
integral P or S trap including jointing the trap
147 15.00 with soil pipe in Cement Mortar1:1 (1- Each
Cement:1-fine sand) (Seal and cover to be
measured and paid forseparately) (A)
vitreous China Pattern :(i) in white colour
Providing and fixing Urinal of approved quality
including connection with trap and with integral
148 10.00 longitudinal flush pipe.(A) Squating plate pattern No.
white earthenware 550mm x 300mm.
Providing & Fixing Angle cock of " Ess Ess" -
Trend series or equivalent standard
make as approved by engg. in charge all 403.39
complete. (N.S.)
Providing & Fixing pillar cock of " Ess Ess" -
Trend series or equivalent standard
make as approved by engg. in charge all 641.53
complete. (N.S.)
Providing and fixing 100 mm size P or S
trap for water closet squatting pan including
150 18.00 jointing the trap with the pan and soil pipe in Each
cement Mortar1:1 (1-Cement : 1-Fine
sand)(A) Vitreous China.Pattern in white colour
Providing and fixing washbasin with single hole
pillar tap with C.I. or M.S. brackets painted white
including sutting holes and making good the
but excluding fittings.(A) Vitreous China:(ii) Flat
Back washbasin 550 mm x v 400mm size. (i) In
Providing and fixing Kitchen sink with C.I. or
M.S. brackets, painted white including cutting
152 15.00 holes in walls and making good the same Each
but excluding fittings. © Vitreous China Sink.
(i) 600 mm x 450 mmx 150 mm size
Providing and fixing 600 mm x 450 mm
bevelled edge mirrror of superior glass
153 15.00 mounted on 6 mm thick A.C. sheet or ply wood Each
sheet and fixing to wooden pluge with C.P.
brass screws and washers.
Providing and fixing chromium plated brass
154 halftrun flush cock of approved quality including
fixing in pipe line etc. complete.(ii) 25mm dia.
Provdg. & fixing White / Color Vitreous
china Counter wash basin with signle hole for
pillar tap of "Cera " - Concord series of
x425 mm size to be fiited in stone counter with
necessary brackets painted white incl.
155 25.00 cutting holes and making good the same No.
.Cost Includes P/F C.P. brass waste
coupline, 32 mm dia fisher union ,15 mm dia.
Pillar cock & Angle cock of " Ess Ess"- Trend
series ,32 mm dia. Waste pipe etc.
complete as per dir. of engg. in charge.
Finishing wall with water proofing cement paint
on wall surfaces (Two coats) to give an
156 1000.00 brand and manufacture and of required shape Smt
even shade after thoroughly brushing the
remove all dirt and remains of loose powered
Extra over Item 156 for every subsequent coat
156 a 1000.00 ofwater proofing cement paint of approved Smt
brandand manufacture. 31.82
Providing & Fixing S.S.304 Grade Sink of
Nirali / Krishna or Equivalent Make for
Kitchen Platform of size : 24":x18" as per 4,650.00
Direction of engg. In charge
Providing and fixing Kitchen sink with C.I. or
brackets, painted white including cutting holes in
157A 2.00 walls and making good the same but excluding Each
fittings. (C) Vitreous China Sink.(i) 600mm x
Providing and fixing C.P. brass towel rail
comlete with C.P.brass brackets fixed to
wooden plugs with C.P. brass scews.(B) 597.22
600mm x 20mm size.
Providing and fixing 600 mmx120 mm glass
shelf with C.P. brass bracket and guard rail
complete mixed to wooden plug with 561.03
C.P.brass screws.
Providing and fixing toilet paper holder. (A)
C.P.Brass 414.53
Providing and fixingof S.S. Railing pipe 50 mm x
161 1.00 16 G ASIS 304 Grade as per instruction of
engineer in charge.
Providing and fixing screw down bib taps of
162 following size. (B) Brass chromium plated
screws down Bib Tap.
Providing and fixing screw down bib taps of
163 following size. © Gun metal screw down bib
Providing and fixing pillar tap, capstan
164 head, screw down high pressure with screws,
shanks and back nuts.
Providing and fixing Gun metal check or
non-return fullway wheel valve.
(III) 25 MM DIA
Providing and fixing brass screw down stop
165 A 10.00 Each
tap.(A) 15 mm dia 203.79
Providing and fixing chromium plated brass
166 10.00 half trun flush cock of approved quality including
fixing in pipe line etc. complete.
(iii) 32mm dia.
Providing and fixing Urinal or approved
quality including conecting the Urinal
167 10.00 with waste pipe , tap etc.complete. (A) White Each
earthen ware flat back or corner type size
Providing and fixing Urinal of approved
quality including connection with trap
168 10.00 and with integral longitudinal flush pipe. (A) Each
Squating plate pattern white earthen
ware 550mm x 300mm.
Providing and fixing chromium plated,
169 10.00 bottle trap with necessary couplings of Each
approved quality for wash basin.
Providing and fixing ball cock ofapproved
170 10.00 quality as directed. (A) Copper Metal (i) 25mm Each
Providing and fixing ball cock ofapproved
171 10.00 quality as directed. (A) Copper Metal (i) 50 mm Each
Filling with good Quality thor as and where
directed by the Architect / Engineer-in-
charge, in sunk in layers of 15 cm. thickness,
including watering, ramming well etc. 3,850.00
complete, as directed by the Architect /
Engineer-in-charge .
Providing laying and jointing in true line and level
15 mm dia. U.P.V.C. Pipe (SCH-40) for
cold water including fittings make PRINCE/
SUPREME/ ASTRAL/ FINOLEX or equivalent
as approved by Engineer In Charge. Pipe
173 10.00 shall be fixed on the wall with the help of Rmt
clamp at every two metre C/C or shall be
concelled as directed including necessary
fittings etc. including testing of pipe and joints
and fixing the same with solvent, including
cost of all materials.adhesive
Providing laying and jointing in true line and level
25 mm dia. U.P.V.C. Pipe (SCH-40) for
cold water including fittings make PRINCE/
SUPREME/ ASTRAL/ FINOLEX orequivalent
as approved by Engineer In Charge. Pipe
174 10.00 shall be fixed on the wall with the help of Rmt
clamp at every two metre C/C or shall be
concelled as directed including necessary
fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent,
including cost of all materials.
Providing laying and jointing in true line and level
32 mm dia. U.P.V.C. Pipe (SCH-40) for
cold water including fittings make PRINCE/
SUPREME/ ASTRAL/ FINOLEX or equivalent
as approved by Engineer In Charge. Pipe
175 15.00 shall be fixed on the wall with the help of Rmt
clamp at every two metre C/C or shall be
concelled as directed including necessary
fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent,
including cost of all materials.
Providing laying and jointing in true line and level
40 mm dia. U.P.V.C. Pipe (SCH-40) for
cold water including fittings make PRINCE/
SUPREME/ ASTRAL/ FINOLEX or equivalent
as approved by Engineer In Charge. Pipe
176 1.00 shall be fixed on the wall with the help of Rmt
clamp at every two metre C/C or shall be
concelled as directed including necessary
fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent,
including cost of all materials.
Providing laying and jointing in true line and level
50 mm dia. U.P.V.C. Pipe (SCH-40) for
cold water including fittings make PRINCE/
SUPREME/ ASTRAL/ FINOLEX or equivalent
as approved by Engineer In Charge. Pipe
a 10.00 shall be fixed on the wall with the help of Rmt
clamp at every two metre C/C or shall be
concelled as directed including necessary
fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent,
including cost of all materials.
Providing and fixing premoulded compressible
filler board in black colour confirming to
MoRT&H Specifications (Clause 1015), having
177 5.00 minimum density 95kg/cum. non-staining with Smt
less than 1% water absorption & compression
recovery of 93% minimum as per specification
for 20 mm wide expansion joint including cutting
to required size and shape at all levels
etc.complete as directed.
Fixing sun film for protection sunlight in black or
178 5.00 any colour as as directd by engineer In Smt
Charge.(Market rate)
Providing & Fixing 3 mm thick F.R.P.sheet
of Approved Quality & Color / Pattern as per
Consultant's design also includes required
fabrication structure in the grid of 2'-0x2'-0
size using hollow pipe of16 gauge & size
179 30.00 2"x1" & 1"x1" ,G.I. & Bitumen Washers, SqM
Silicon paste application for fixing the sheet
. Rate also includesnecessary bending, cutting,
labor charges , Zinc Primer coat & Two coats
of oil painting of color as approved by
consultants & making good the wall. (N.S.)
Providing 2 mm thick F.R.P. Gutter with
180 15.00 necessary M.S. Supporting Brackets. (N.S.) Rmt
Hiring charges for J.C.B.machine inclduing
181 6.00 cost of fuel, operator, dirver etc.. ( 12 Hrs.
hours sift day/night) (N.S.)
To provide tractor with hydraulic trolley, driver,
4 Nos. of Labor with all tools like bucket drum,
showels, trikam, pavadas, etc,, to
182 5.00 carryout different works during monsoon for No.
12 Hrs. Shift. Work shall be carried out as
per the instrucitons of Engineer In-Charge.No
extra charged shall be paid for night shift.
Roller Blind Providing and fixing Roller Blind
curtain fixed on window level on wooden
batten and curtain lift with cotton thin rope,
183 1.00 make of aerolax or equivalent design Smt
and colour as per instruction by engineer –
in – Charge with necessary hardware fitting,
material and labour etc complete.
Providing & Fixing Door closer - complete of
184 5.00 Approved make to wooden / Aluminium Doors as No.
per direction of engg. In charge.
Providing and fixiing M.S. Fan clamps type 1 of
16 mm dia M.S. bar bent to shape with hooked
185 5.00 ends of R.C.C. slabs during laying incl. painting No.
the exposed protion of loops, all as per standard
design complete.
Providing cement vata (10cm. x 10 cm. size)
186 5.00 quarter round in cement mortar 1:1 including Rmt
neat cement finishing, watering etc. complete.
187 2.00 Making Water connection from exi.Muni. Water No.
line (N.S.) 250.00
Applying and providing Expansion joint sealing
System on 100 mm vide joint including cleaning
exansion joint by mechanical means provision of
adhesive and flexible membrane with required
bond length as per menufracturer specification
188 2.00 and Smt
4mm thick alluminium strip covering with one
sloted and bolted with suitable system, inclusive
all manpower, machinery and material as per
specification and as directed.
Providing and Fixing 1 H.P. Electrical monoblock
or submarcible water pumps withmotor and
required cable and switch board of approved 6,800.00
brand and make etc.comp.as directed.
.Providing TMT Bar FE 415 reinforcement for
R.C.C. work including bending, binding and
placing in position complete up to floor two level 66.59
ProvidingTMTBarFE500/500Dreinforcement for
R.C.C.workincluding bending,binding and
placing in position complete upto floor two level
placing in position complete upto floor two level 75.46
placing in position complete upto floor two
level(upto 10 ton)
Providing and fixing 30mm thick solid both side
prelam PVC door shutter (sintex door-
equivalent) with necessary alluminium fitting with 2,214.00
EL-7 section frame
Providing & Fixing in position Alluminium window
sliding / fix type with frame using approved
anodised extruded alluminium section as
approved by Engg. In charge.(Jindal alluminium)
units equivalent (a) Frame sections 65 x 25 mm (
at 0.41 kg/mt) (b)Sliding Frame bottom section of
192 1.00 61.85 x 31.75 mm (at 0.41 Kg/Rmt) © Shutter Sq. M.
top & bottom section 40 x18 mm ( wt.
Kg/Rmt ) (d) Shutter interlock vertical section
x 18 mm.( 0.41 Kg/ Rmt) (e) Shutter vertical of
40 x 18 mm. (0.41 Kg/Rmt) including P/F
installing 5 mm thick approved color Acrylic
sheet of standard quality etc.comp.
Providing and laying polished granite stone slab
18 mm thick in risers of steps, dedo and pllars
laid on 10 mm thick cement mortar 1:3 (1
cement:3 coarse sand) and jointed with gray 2,690.00
cement slurry including rubbing & polishing
Wall panelling with 12 mm MDF fixed to
existing alluminium framing and making grove
194 2.00 as per design and finished with royal plastic Smt
paint as per instruction of engineer incharge.
Providing and laying 15mm bamboza
wooden flooring as per architect's drawing
with all necessary details as directed by
195 10.00 the project consultants. Use underlay for Smt
better result as per Detail specifications and
directed by the project consultants. (N.S.)
(Approved Rate )
Providing 20 mm thick double coat mala cement
plaster on interior brick / concrete work for
plastering comprising of base coat of 12 mm
thick cement plaster in cement mortar (1 Cement
: 4 coarse sand) in rough finishing and 8 mm 269.78
thick top coat of cement mortar 1:2 (1 Cement :
2 Coarse sand) finished with trovel including
scaffolding curing etc. complete.
Finishing wall with weather proof exterior
emulsion paint on wall surface (two coats) to
give an required shape evenshade after
thoroughly brushing the surface to remove all 113.40
dirt, and remains of loose powdered
materials.etc complete
High Back Chairs for vip Lounge
:Supplying and installation of “Revolving
High Back” chairs. The chairs must be
robust, ergonomically designed and
comfortable. Seat & Back Assembly -
1.2 cm thick hot pressed plywood and
upholstered with Fabric and Molded
Polyurethane Foam with PVC lining all
around. Back foam is designed with
contoured lumber support for extra comfort.
Chairs Dimension - Width 55 cm, Depth
cm Height 103 – 115.5 cm, Seat Height(SH)
44 – 56.5 cm. The Polyurethane foam should
be molded with density 45+/-2 kg/m3 &
Hardness = 16+/-2 kg/m3onHampden
machine at 25% compression. Arm Rest
- One-piece Black integral skin
polyurethane with 50-70 shore. `D’ Type Handle
and reinforced with MS insert. Centre
Pivot Mechanism - 360o revolving type 17o
maximum tilt on pivot at centre Tilt tension
adjustment. Upright locking. Telescopic
Bellow Assembly - The bellow should be 3 piece
telescopic type and injection molded in black
Polypropylene. Hydraulic Height Adjustment -
The Hydraulic height adjustment should be
provided with adjustment stroke of at least
10cms. Pedestal Assembly - The pedestal
should be injection molded in Black
powder coated MS on and fitted with 5 nos.
twin wheel castors. Twin wheel castors -
The twin wheel castors should be injection
molded in Black Nylon The complete
item as per architect /engineer in charge
Providing and supplying Medium Back
Chair for Control room MODEL LIKE
HOF OCT 172 Revolving synchro
tilting mechanism based chair with gas lift
for adjustable height and medium curved
back with seat and back PU molded cushion
with MS pipe frame structure and white
foam layer for seat and molded PU foam. White
foam layer for back covered with thick
199 3.00 cloth and draped with cloth of approved Each
shade. (min. of Rs.150/meter). 5 legged
revolving molded nylon chair base with good
quality of PU castors with 2 years replacement
guarantee. The chair to have wide polyurethane
arm rest of approved shape. Complete chair
should be in suitable shape. Rates to be
inclusive of all taxes and free delivery at
site. The complete item as per architect
/engineer in charge
Providing and fixing storage, entire unit to be
made from 19 mm th. and 12mm Ply with
1.0mm &. 8 mm th. Laminate. Shelves to be
made from 19mm Ply with both side
laminate. Rate shall include necessary
200 60.00 approved mortise locking systems, S S Smt
Handle pair 2" to 4" height and necessary
hardware. Over all storage to be completed
with necessary hard ware and accessories
completed as per drawing and design as
given by Architect.
Existing storage repairing and veneer on
top Providing and fixing of Louvers On Existing
d.c panel Providing and fixing 35mmthk.
Louvers shutter made up from Ghanateak
frame with 135x75mm and shutter frame as per
detail and fixing aluminum louvers which
is specified readymade powder
coated aluminum grill panel louvers .and 7,500.00
applying melamine spray polish all exposed
wood work. Overall door to be completed
with necessary hardware and
accessories completed as per drawing and
design as given by Engineer In
charge/Architect.
Providing and fixing flush door shutters,
solid core construction with frame of first
class hardwood with cross board and face
veneer or plywood face panels, with both side
1 mm laminate finishing including
anodized aluminum butt hinges with
necessary screws. Decorative type and
pine wood core anodized minimum 3 no
mm long aluminum butt hinges in flush door
202A 2.00 shutters with 2 no of brass holdfast 325 mm Smt
long 1 no brass tower bolt 250 mm long and
two no of 150 mm long brass door handle .
Decorative both side laminated Flush door
mm thick. with frame of 10 cm x 7 cmt
Indian teak wood frame including all
necessary fitting fixtures hardware screw
and adhesive etc fixing up to all lead and lift
height up to 45 mtr from GL etc complete as
per direction of engineer in charge
Providing and fixing 35mm thick factory made
moulded door shuter consisting of solid core
single leaf flush door of 30mm thickness, lipped
with 15mm (5mm x 3) thick x 30mm width on
one stiles and top rail and 10mm (5mm x 2) thick
x 30mm width on the other stilesand bottom
rails. The inner panel laminated with 2mm thick
termite proof, water proof and fire resistant
B 2.00 moulded PVC Smt
sheet with 2,4,6 raised panel design in different
plain and /or prelim colours on one side after
routing the moulded design on flush door and
2mm plain and/or prelim PVC sheet on other
side using rubber adhesive on flush door and
solvent cement adhesive on the PVC liping etc.
complete as per direction of Engineer in charge,
manufacture’s specification and drawing.
P/M/F chainlink jali 8'x4' size as per details
sketch & instructionof engineer in charge same
as lal darwaja garden pattern consisting of 3'dia.
M.S black pipe 'A' class 5'4" ht. fixed at 8'9" c/c
in C.C 1:2:4 block of 9"x9"x9" size chain link jali
of size 2"x2"x10 gauge fixed in 35x35x5 mm MS
angle frame 8'x4' size with MS flat of size 25x3 1,230.00
mm welded jali etc.comp.The jali is to be welded
to MS pipe with MS flat as instruction given.The
M.S pipe and the M.S angle frame are to be
painted one coat of primer and two coats of paint
as directed in line and level. (N.S)
Providing & Fixing masonary wall with porbandar
lachiya stone with well dressed grooveas per
directed by engg.in charge for foundation, plinth
or super structure level (above plinth level upto
floor two level) in cement mortar 1:5 (1-cement :
5-fine sand) incl.pointing the joint with white
cement and yellow oxide powder in proportion to
match stone colour the joints should be thread
grooved as per exi. lake stone pitching
(A) stone masonary wall/stone dressed single
faced (size 15"x8"x9") 8,990.00
(B) stone coping (size 15"x8"x4")
(C) stone coping (size 15"x8"x9")
(D) stone column (size 15"x15")
(E) stone column top (size 20"x20"x9")
Supplying and fixing of 300 mm-L x 150 mm-
B x 380 mm-H Kerb block for Footpath in M-
20 grade using 20 mm nominal size black
trap aggregate of Sevaliya/Timbaor
equivalent quality for pre-cast blocks,
reasonablyexposed finish/ formwork
, mould with well equippedwith vibratory
system for kerb stones of approved design
including curing, etc. complete, including
205 50.00 thecost of formwork etc. complete. The Rmt
rate shall also include necessary cutting
of asphalt, fixing the Kerbstones in line and
level on 5 cm thick sand bedding
withnecessary equipments and materials.
The rate shall also include the flush pointing
in CM (1:3) for all joints of thekerbstones. Filling
of zari alone the sides of the kerbstone fixed
with Bituminous concrete
Bituminousconcrete / C.C. mixed in proper
position to flush withthe road surface as
directed by Engineer in change to form a
portable mixture.a) Laying on 5 cm thick Sand
Providing and fixing pre-cast concrete kerb stone
of gray cement based concrete block 30cm
length,30cm height and 15cm thick of M200
b 25.00 grade concret as per approved design and Rmt
including excavation for fixing in proper line and
level,filling the joint with C:M 1:3 (1cement:3fine
sand) etc complete.
Providing and Laying of Rubber Moulded Paver
Block Grey/Coloured 60 mm thick, M-35 Grade
of any size shape (Usually Uni-Paver Blocks)
using black trap good quality aggragate of
mm nominal size for footpath,parking areas,
service lanes and other areas as mentioned in
the drawing / instruction of engineer in charge.
Cost includes formworks using rubber mould,
Rate providing and laying paver blocks as per
required grading and specification. The paver
block shall be mechanically compacted. The
work of paving blocks shall be executed in line 501.60
and level by skill mason of flooring work only. It
should be laid in such a way that the no cutting
of the paver block to be necessary. if cutting of
paver block necessary then it should be cut by
machine only and carting. The finished surface
of the paver block shall have resonably good,
plain finished. Paver blocks shall be compacted
and shall be relaid if necessary. Gravel or such
type of materials shall not be allowed for
production. Laying on 5 cms thick sand
Provoding and fixing flush door shutters, solid
core construction with frame of first class hard
wood with cross board and face veneer or ply
wood face panels, including anodised alluminium
butt hinges with necessary screws. (B) Non- 1,779.97
decorative type and block board core anodised
alluminium butt hinges in flush door shutters (2)
35 mm thick. Labour work for fixing any kind of
paving with cement pointing in CM 1:2, including
watering, ramming etc comp. as dir.For
I) Laying on Sand bedding as per requirement to
208 5.00 fix the C.C.Block / Nibhada Stone in Line & Level Smt
Box type metal letters forming composite box
made from 1mm thick stainless steel plate of
grade 304 having brush finish of following font
size to be fixed at Main Gate in english and or
Gujrati and including fixing charges approved
before fixing by clent / consultant.
Providing and fixing false ceiling at all height
including providing and fixing of frame work
made of special sections, power pressed from
M.S. sheets and galvanized with zinc coating of
120 gms/sqm (both side inclusive) as per IS :
277 and consisting of angle cleats of size 25 mm
wide x 1.6 mm thick with flanges of 27 mm and
37mm, at 1200 mm centre to centre, one flange
fixed to the ceiling with dash fastener 12.5 mm
dia x 50mm long with 6mm dia bolts, other
flange of cleat fixed to the angle hangers of
25x10x0.50 mm of required length with nuts &
bolts of required size and other end of angle
hanger fixed with intermediate G.I. channels
45x15x0.9 mm running at the spacing of
mm centre to centre, to which the ceiling section 850.00
0.5 mm thick bottom wedge of 80 mm with
tapered flanges of 26 mm each having lips of
10.5 mm, at 450 mm centre to centre, shall be
fixed in a direction perpendicular to G.I.
intermediate channel with connecting clips made
out of 2.64 mm dia x 230 mm long G.I. wire at
every junction, including fixing perimeter
channels 0.5 mm thick 27 mm high having
flanges of 20 mm and 30 mm long, the perimeter
of ceiling fixed to wall/partition with the help of
rawl plugs at 450 mm centre, with 25mm long
dry wall screws @ 230 mm interval, including
fixing of gypsum board to ceiling section and
perimeter channel with the help of dry wall
screws of size 3.5 x 25 mm at 230 mm c/c,
including jointing and finishing to a flush finish of
tapered and square edges of the board with
recomme-nded jointing compound , jointing
tapes , finishing with jointing compound in
layers covering upto 150 mm on both sides of
joint and two coats of primer suitable for board,
all as per manufacturer’s specification and also
including the cost of making openings for light
fittings, grills, diffusers, cutouts made with frame
of perimeter channels suitably fixed, all complete
as per drawings, specification and direction of
the Engineer in Charge but excluding the cost of
Providing and fixing wall acoustical paneling
using ecotone Slato/ Anutone slato or equivalent
Acoustic Panel make Slats L-16 of size
128mmx2430mmx16mm thick up to 2400mm
high as per the following specification :-Slats L-
16- 2mm @16mm, 32 x 128 x 2430 mm high
grade Pine wood base Medium Density Fiber
acoustic boards with Tongue & Groove
Edge,2mm slot perforation @ 16mm centre,
slates perforations, The acoustic should be
furnished with a Black absorbent felt backing
with an airflow resistance of 330- 460 Ns/m³
(DIN 53887),wood practical core,NRC : should 4,160.00
be Up to 0.75,should meet the safety
requirements of EN 14190. Fixing :- Sound Strut
CC18 screw fixed horizontal/vertical to wall at
every 600mm c/c. Metal cleat can be fixed on
top edges of Sound Strut CS55 fixed directly by
stamping to the CS55 and IC91 which is screw
fixed directly to the wall where ever required with
a backing black color fabric as approved by
Architect and as specified including all
accessories, material & labor complete as
directed by Architect / Engineer.
Providing & Fixing SPEED BUMP - #2 No (1
black, 1 yellow) 350 x 500 x 50 mm, Size per
color End Cape 350 MM x 175 MM x 50 MM
TOP DESIGN - Lining Top flat ANTI SKID
PATTERN FOR GRIP COLOUR :- YELLOW &
BLACK BODY MATERIAL :- MODIFIED
THERMOPLASTICS (Polymer Rubberized ) • 2,185.00
ECO FRIENDLY RECYCLE RUBBER Packing
:- 4 pcs/ woven Bag Load Capacity :- 20 MT
Fitting ( Fixing on TRAKE) :-4 holes & END
CAPE :- 2 HOLE HEX Bolts with Washer Epoxy
for Bolt Fitting etc. complete as directed by EIC .
Providing & Fixing in position 24 MM exposed
grid suspension system with “P “ Grid profile
false ceiling system using 600 MM X 600 MM
ecotone/anutone or equivalent make Glass Fiber
Ceiling Tiles having tegular edges & 0.90 NRC
value and approved surface design (with NRC of
0.90) and edge profile Tegular placed in a
suspended grid of size 600 MM X 600 MM made
from hot dipped GI Steel sections, rotary
stitched, main tee of size 24 X 42 X 3000 MM X
0.40 MM thickness suspended at every 600 MM
c/c along length of ceiling with 4 MM dia, Pre- 2,619.00
straightened G.I.Wire with necessary level
adjusters & intermediate cross tees of size 24 X
38 X 600 MM X 0.40 MM thickness shall be
inserted in to slots between the main tees at
MM centers in direction vertical to the main tees,
where in the main tees are resting on the
periphery on wall angles of size 24 MM X 24 MM
X 3000 MM X 0.40 MM thickness including
providing necessary openings for light fixtures,
Providing and fixing of Roller blind
curtain/blackout. The fabric shall be woven from
formulated platisol extruded over a polyaster
yarn.The fabric shouldl be weaved to provide
subtle view of the side of the blind and should 2,610.00
offer elimination of glare and sunlight radiance
upto a minimum of 80%.The fabric shall be flame
Providing and applying Texture Paint (Rustic
Finish) on external plastered surfaces, pattern
as per sample approved by the Architect.
including preparing surface, using roller to get
approved texturised surface. Job to include
making required surface preparation, to receive
Texture paint finish etc. All complete as per 425.00
detail drawing, as specified and as directed by
Architect / Consultant / Project - In - Charge. The
rates shall be inclusive of Scaffolding, all
material, labour etc. complete. as directed by
Providing and fixing PVC/Gpsysum plain colour
false ceiling with grid type with aluminium
frame from gypsteel, fastners ,props, Finishing
as per architectural drawing allowing
216 2.00 openings for A.C. Diffusers, Smt
Light/Electrical Points etc –complete, Prior to
fixing on frame.(Brand : Anutone or
equivalent ) (N.S.) or as directd by engineer In
Provdg. & laying S.W. Gully trap with brick
masonry chamber & water tight G.T.Stone
including fixing of covervSquare mouth trap 100 1,279.40
mm x100 mm size P-Trap
Providing cement vata (10cmx10cmsize) quarter
218 50.00 roundin cement mortar 1:1 including neat Rmt.
cement finishing, waterin getc. complete.
Providing and laying (to level or slopes) and
jointing with stiff mixture of Cement Mortar in
219 5.00 proportion 1:1 Salt glazed stoneware pipes Rmt.
including testing of pipes and joints complete.(A)
Providing and laying (to level or slopes) and
jointing with stiff mixture of Cement Mortar in
220 10.00 proportion 1:1 Salt glazed stoneware pipes Rmt.
including testing of pipes and joints complete.(B)
Constructing brick masonry chamber for
underground C.I. Inspection chamber and bends
with bricks having crushing strength not less
than 35Kg/Cm2 in C.M. 1:5 C.I. cover with frame
(Light duty) 455mm x 610mm intenal dimensions
total weight of cover with frame to be not less
than 38Kg. (Wt. of cover 23 Kg.) and Wt. of
221 10.00 frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix Each
(1-cement :2- coarse sand :4-graded stone
aggregate 20mm size) foundation concrete
1:5:10 inside plaster 15mm thick with cement
mortar 1:3 finished smooth with a floating coat of
neat cement on walls and bed concrete etc.
complete.(i) Inside dimensions 455mmx 610mm
and 450mm deep for single pipe line.
Constructing brick masonry chamber for
underground C.I. Inspection chamber and bends
with bricks having crushing strength not less
than 35Kg/Cm2 in C.M. 1:5 C.I. cover with frame
(Light duty) 455mm x 610mm intenal dimensions
total weight of cover with frame to be not less
than 38Kg. (Wt. of cover 23 Kg.) and Wt. of
frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix
(1-cement :2- coarse sand :4-graded stone 3,624.51
aggregate 20mm size) foundation concrete
1:5:10 inside plaster 15mm thick with cement
mortar 1:3 finished smooth with a floating coat of
neat cement on walls and bed concrete etc.
complete.(i)Inside dimensions 500mm x 700 mm
and 450mm deep for pipe line
with one or two inlets.
Constructing brick masonry chamber for
underground C.I. Inspection chamber and bends
with bricks having crushing strength not less
35Kg/ Cm2 in C.M. 1:5 C.I. cover with frame
(Light duty) 455mm x 610mm intenal dimensions
total weight of cover with frame to be not less
38Kg. (Wt. of cover 23 Kg.) and Wt. of frame
222A 10.00 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1- Each
cement :2- coarse sand :4-graded stone
aggregate 20mm size)
foundation concrete 1:5:10 inside plaster 15mm
thick with cement mortar 1:3 finished smooth
with a floating coat of neat cement on walls and
concrete etc. complete.(iii) Inside dimensions
600mm x 850 mm and 450mm deep for pipe
lines with three or more inlets.
Providing, supplying and fixing precast C.C.
blocks (M-20) edge kerb having size of 75 x
x 300 mm depth and as per design conveying it
to the site, jointing into C:M 1:3 and racking out 219.00
the joints incl. necessary excavation of asphalt,
soil etc..completed.
Constructing a cooking Sandwich platform
cm. width and 70 cm high resting on
B.B.Masonry walls23 cm.thick in C.M.(1:6) with
(ii) Fixing black Granitee 30mm thick laid on 933.98
precast R.C.C. (1:2:4) slab with plastering on
exposed faces of wall in C.M. (1:4) etc complete.
Constructing a cooking platform 60 cm. width
and 70 cm high resting on B.B.Masonry walls
cm.thick in C.M.(1:6) with (ii) Fixing black
kadappa stone 30mm thick laid on precast 1,132.43
R.C.C. (1:2:4)slab with plastering on exposed
faces of wall in C.M. (1:4) etc complete.
Providing and fixing hard drawn steel wire fabric
75mm x 25mm mesh or weight not less than
7.75 kg. per Sq.M. to window frames etc. 754.65
including60 x 20mm beading of teak wood.
Providing & fixing 15 cm wide chicken mesh jali
with nails & then application of 15 mm plaster on
R.C.C.& masonary joints as per dir.of engg.in 35.00
Providing and laying cement concrete flooring
1:2:4 (1-cement : 2-coarse sand : 4-graded
227 10.00 stone aggregate 20mm nominal size) laid in one
layer and finished with a floating coat of neat
cement. (A) 50mm thick.
Providing and constructing, Underground (U/G)
water tank of specified capacity, on specified
location, for all depths, in controlled CC of M-200
grade with bottom slab, top slab and RCC walls,
including cost of form work and
reinforcement,with inside and outside plaster in
228 25000.00 CM 1 :3 and water proofing treatment as per
IWP specification,including injection, grouting,
etc. complete. The rate includes for providing
and fixing two nos. 0.6m. x 0.6 m. size medium
duty CI manhole cover/s at top, including wash
out pipe line and inlet and outlet connections etc.
Providing & Fixing of Armstrong Mineral Fibre
Acoustical Suspended Ceiling System with Dune
(Bevelled Tegular) Edge Tiles With Armstrong
15mm Exposed GRID. The tiles should have
Humidity Resistance (RH) of 99%, NRC 0.5,
Light Reflectance ≥85%, Thermal Conductivity k
= 0.052 - 0.057 w/m K, Colour White, Fire
Performance UK Class 0 / Class 1 (BS 476 pt -
&7) in module size of 600 x 600 x 15mm
suitable for Green Building application, with
Recycled content of 32%. The tile shall be laid
on Armstrong Silhouette profile grid system with
229 10.00 15mm white flanges incorporating a 6mm central
reveal in white/black colour and with a web
height of 45mm and a load carrying capacity of
minimum 15.68 Kgs/M2 & minimum pull out
strength of 100 Kgs.. Silhouette, Main Runners
& Cross Tees to have mitred ends &
“birdsmouth” notches to provide mitred cruciform
junctions. The T Sections have a Galvanizing of
90 grams per M2 and need to be installed with
Suspension system of Armstrong make.
Warranty Certificate and Test Reports for NRC,
CAC and Fire rating shall be provided by
Mineral Fibre Acoustic Modular Ceiling Tile
should be GREENPRO certified and qualifies as
GREEN PRODUCT certified by CII Green
Products and Services Council.INSTALLATION:
To comprise main runner spaced at 1200mm
centres securely fixed to the structural soffit
using Armstrong suspension system
(specifications below) at 1200mm maximum
centre. The First/Last Armstrong suspension
system at the end of each main runner should
not be greater than 450mm from the adjacent
wall. Flush fitting 1200mm long cross tees to be
interlocked between main runners at 600mm
centre to form 1200 x 600 mm module. Cut
cross tees longer than 600mm require
independent support. 600 x 600mm module to
be formed by fitting 600mm long flush fitting
cross tees centrally between the 1200 mm cross
tees.Perimeter trim to be Armstrong wall angles
of size 3000x19x19mm, secured to walls at
mm maximum centres. Installation should be
carried out as per Armstrong recommended
procedure.ARMSTRONG SUSPENSION
SYSTEM accessories manufactured and
supplied by Armstrong World Industries
consisting of M6 Anchor Fasteners with Vertical
Hangers made of Galvanised steel of size 26 x
26 x 25 x 1.2mm with a Galvanised Thickness of
80gsm, A pre Straightened Hanger wire of dia –
2.5 mm of 1.8 m length., thickness of 80gsm and
a tensile strength of 344-413 MPa, along with
Adjustable hook clips of 0.8mm thick, galvanised
spring steel for 2.68 mm with a minimum pull
strength of 110 kg. The adjustable clip also
consists of a 3.5 mm aquiline wire to be used
with the main runner.
Providing and fixing PVC Printed pain colour
false ceiling with grid type with alluminium frame
consisting of 600mm x 600mm 3mm thick plain
PVC sheet used as panel insert in a frame work
made using anodized alluminium T section of
size 1 x 1 (235 x 25mm, 19 gauge or 1 mm thick)
in square pattern of grid sizes of 2 x 2 (600 x
600mm) The alluminium frame work is supported
230 10.00 from the cceiling with the help of G.I. hook and
G.I. wire/6mm M.S. rods of required sizes to
maintain proper level etc. The aluminium frame
work is supported on side wall with the use of
alluminium L section of size 1 x1 (25 x 25mm)
angles etc. complete as per direction of Engineer
in charge. Manufactures specification and
Providing and supplying of labour for necessary
manual excavation, cleaning, Shifting of Material
231 15.00 Or any other, or for any other work as directed
by Engineer In charge. The Rate includes
Handcart with Mazdoor
Fitter/Plumber/Mason
WELDER/ Gas cutter at Day /night
Supplting of welding machine / gas cutter
including cost of welding rods/gas,
D 5.00 Transportation, including carting from site to
Mazdoor at Day Male/Female
Conveyance charges of (A) limemurrumbuilding
rubbish earth manure or
232 200.00 sludge & execavated rock andrubbish
[Limemurrum building rubbish
Supplying electric breaker machine for RCC slab
or asphalt demolishing work on site by using
operator, fuel, power supply etc.complete as
directed. (no payment should be allowed for non
233 1.00 working condition of machinery and for pipe line
excavation and M.H. work. Allowed only for
break down work) (Based on Previously
approved rate by CE sir )
CatchPit Jali Fixing P/F FRC catch pit jali with
frame 600mm x 600mm clear opening etc.
234 5.00 comp. As directed by engineer in charge. (Based
on Central Store Rate)
Providing and fixing concealed center point to
wall ceiling & floor CPVC (SDR 13.5) PIPE
having National Sanitation Foundation (NSF)
235 seal for potable water of following dia. nominal
bore tube fittings and clamps including making
good the wall, ceiling and floor etc. complete.
Providing and fixing cast iron steps of size
236 10.00 500mm x 150mm x 22.5mm and painting with
two coats of Anti-corrosive paint etc. complete.
Supplying and fixing C.I. cover 300mm x 300mm
237 10.00 without frame for Gulley trap (Standard pattern)
te weight of cover to be not less 4.53 Kg.)
Providing and fixing to wall ceiling and floor
10.0Kg.F/Cm2 working pressure polythene
pipes of the following out side Dia.
238 Low densidy, complete with special falnge
compression type fittings, wall clips etc.
including making good the wall ceiling and
Providing and fixing sheet glass, selected quality
(Type-C) bedded in putty and fixed withwooden
239 10.00 beading including the cost of wooden beadings
of first class teakwood and necessary cutting of
glass. (2) 6 mm thick.
Providing and fixing rough cast wired glass,
6mm thick bedded in putty and fixed with
240 10.00 wooden beading including the cost of wooden
beadings of Indian teak wood and necessary
cutting of glass. (C) Wired - figured glass
Providing and fixing five courses water profing
treatment with bitumen felt consisting of second
and fourth course of blown / bitumen or/ and
residual bitumen applied hot at 1.2 kg.per
Sq.M.of area for each course and first course
with fibre base bitunen saturated under lay type
land third course
241 20.00 with fibre base self finished felt type 2 grade 1
fifth and final course of stone grit 6mm and down
size or pea sizes gravel spread at 0.008 Cu.
Metre / Sq. metre
including preparation of surface excluding
grading complete.
Providing and fixing three courses water profing
treatment of Astral Make Company. with an first
layer of first course with fibre base, Second
Course of Water Proofing chemical coat, and
Third Coat of Fibre Coat with fibre base self
242 20.00 finished felt type 2 grade 1 and final course of
Burshing with chemical Treatment with a
thickness of 1 to 2 mm thickness, including
preparation of surface , The Said work should be
provided for a perfomance bond of 5 Years for
warranty purpose.
Constructing Manhole with R.C.C. top slab in
1:2:4 mix (1-cement :2-coarse sand : 4-graded
stone aggregate 20mm nominal size) foundation
concrete1:3:6 mix (1-cement : 3- coarse sand :6-
Brick bats 40 + 50mm size) inside plastering
15mm thick with Cement Mortar 1:3 (1-Cement :
3-coarse sand) finished with a floating coat of
neat cement and making channels in cement
concrete 1:2:4 mix (1- Cement :2-Coarse sand
:4-stone aggregate 20mm nominal size) finished
243 5.00 smooth complete including curing and festing (i)
Inside size 900mm x 1200mm
and 1.5M. deep including C.I. cover with frame
size 560mm diameter total weight of cover and
frame to be not less than 128 kgs. (Wt. of cover
64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm
thick walls of brick msonry using brick having
crushing strength not less than 35Kg. / Sq.cm. in
Cement Mortar 1:5 (1- Cement: 5-Coarse sand)
(1) A type depth 0.90 Metre for 150mm diameter
Providing and fixing of wall paper at Wall/Ceiling/
or at other places, as required. ( Basic Rate of
244 5.00 Wall paper must be (100-120) Rs. Per Sq.Ft.
The Rate includes of necessary material, with
fixing and transporation with necessary solution.
Providing and fixing of Shower of jaquar make
245 5.00 for Serial No. 0797N ALD ( High Flow C/Body-
Jaquar, Primary Batch )
Providing and fixing of Metro Pole of 40 mm dia
246 5.00 of Jaquar Make of series FLV-1093 N ( Serial
Providing and fixing of chair bracket for Support
247 5.00 of W.C. of Primary batch Series-7324 of Jaquar
Providing and fixing of upper part of W/C of
248 5.00 jaquar series of 8481
Providing and fixing of 2 in 1 Bib cock of jaquar
249 5.00 Series of KUP-35041 (8481) as per Instructions
of engineer in charge.
Providing and fixing of Pillar cock of jaquar make
250 5.00 series EXTND 190 MM as per instructions of
engineer in charge.
Providing and fixing of Angle cock of jaquar
251 5.00 make series of KUP-35053 PM
Providing and fixing of shower of size 8x8m
including shower arm, flange, floor trape,
252 5.00 including all material with fixing as per
Instructions of engineer in charge.
Supplying and fixing of Roller blind curtain In
Patterned Fabric of Different Textures corded in
roller blinds with stiching fittings and of stichles
253 5.00 pattern. The Price Rate Includes necessary
Making with fixing of roller blind with roller
mechanism as instruction and selection of
design as per engineer in charge.
Supplying and fixing of Sheer Curtains of
Different Size, In Patterned Fabric of White
Colour Textures stiching fittings and of stichless
254 5.00 pattern. The Price Rate Includes necessary
Making with fixing of Sheer Curtain with top
channels of fixing as instruction of engineer in
Supplying and providing of Green Curtain for
prevention of Sunlight. The Price Rate Includes
blackout curtains with dense or fabirc or foam
255 5.00 interlining material. The Price Rate also Includes
necessary fixing with roller tie ropes at site at
any height as per instruction of engineer in
Demolition of Existing Platform and Construction
of New Modular kitchen with necessary drawer
Arrangement, Providing and fixing of chimney,
and Providing of Self for Placing of utensils, with
tandom channels, Laminates in hard board
material. The Rate also includes construction of
Platform in Granite work, including kitchen sink
256 1.00 and with necessary Plumbing work, as per
Instructions of engineer in charge. The Rate
includes with necessary materials of hardware,
manpower, necessary machinery for platform
work and other civil works upto any lead and lift
as directed. The Rate also includes carting of
materials for to and fro at the site.
Supply & fixing factory finished cold formed Light
guage steel frame sections confirming to SP:6
(5) 1980 at site or work including riveted, bolted
or welded in builtup for all type of sections ,in
257 750.00 framed work, cutting, hoisting, fixing in position
applying primer coat of approved steel primer
etc. complete as per structural designs &
directions of Engineer-in-charge.
Providing valleys 900mm overall in plain 1.6mm
258 2.00 thick G.I. sheet fixed with G.I. J or L Hooks, Bolts Smt
and nuts glavanised iron J or L Hooks Bolts and 1,042.78
nuts 8mm dia G.I. Limpet and bitumen washers
Providing laying (to level or slopes) and jointing
reinforced concrete Light duty non-pressure
pipes I.S. class NP2 of the following internal
259 2.00 diameter with collars and butt ends prepared for
collar joints including testing of joints
complete.(D) 300mm
Constructing Manhole with R.C.C. top slab in
1:2:4 mix (1-cement :2-coarse sand : 4-graded
stone aggregate 20mm nominal size) foundation
concrete 1:3:6 mix (1-cement : 3- coarse sand
:6-Brick bats 40 + 50mm size) inside plastering
15mm thick with Cement Mortar 1:3 (1-Cement :
3-coarse sand) finished with a floating coat of
neat cement and making channels in cement
concrete 1:2:4 mix (1- Cement :2-Coarse sand
:4-stone aggregate 20mm nominal size) finished
260 1.00 smooth complete including curing and festing (i)
Inside size 900mm x 1200mm and 1.5M. deep
including C.I. cover with frame size 560mm
diameter total weight of cover and frame to be
not less than 128 kgs. (Wt. of cover 64 Kg. and
Wt. of frame 64 Kg.)(A) With 230mm thick walls
of brick msonry using brick having crushing
strength not less than 35Kg. / Sq.cm. in Cement
Mortar 1:5 (1- Cement: 5-Coarse sand) (2) B
type depth 1.50 Metre for 150mm diameter
Providing laying (to level or slopes) and jointing
reinforced concrete Light duty non-pressure
pipes I.S. class NP2 of the following internal
261 9.00 diameter with
collars and butt ends prepared for collar joints
including testing of joints complete.(D) 300mm
ELECTRICAL WORKS:-
Point wiring for secondary light point with 2-
1.5 sq.mm & earthwire of 1.5 sq.mm (green)
both are of ISI marked 1.1 KV grade FRLS
PVC insulated multistrand copper wires, in
following type of pipe to be erected
concealed in / flushed on wall/ceiling, complete
with earth continuity and necessary 120.00
connection with primary light with accessories
erected on Metal / PVC box covered with
mm thick PC(Polycarbonet) / Acrylic sheet for
open / concealed wiring.with necessary Lamp
holder / ceiling rose / H.D.Connector as
directed.(a) with medium class Rigid PVC
pipe and accessories.
Providing and laying 4.0 sqmm circuit
2 1.00 wiring with 2.5 sqmm earth wire of green color Rmt.
Point wiring for secondary light point with 2-
1.5 sq.mm & earthwire of 1.5 sq.mm (green)
both are of ISI marked 1.1 KV grade FRLS
PVC insulated multistrand copper wires, in
following type of pipe to be erected
concealed in / flushed on wall/ceiling, complete
with earth continuity and necessary
connection with primary light with accessories 120.00
erected on Metal / PVC box covered with
mm thick PC(Polycarbonet) / Acrylic sheet for
open / concealed wiring.with necessary Lamp
holder / ceiling rose / H.D.Connector as
directed.(a) with medium class Rigid PVC
pipe and accessories.
Providing and laying 4.0 sqmm circuit
4 1.00 wiring with 2.5 sqmm earth wire of green color Rmt.
Suppling and laying Cat 6 lan cablel of d-
5 1.00 link or equivalent make etc. complete. (N.S.) Rmt
Mains with 1.1 KV grade FRLS PVC
insulated ISI marked stranded Copper
conductor wire in following type of pipe to be
erected concealed in /flushed with
6 wall/ceiling, with 1.5 sq. mm copper
conductor FRLS PVC insulated stranded
wire of green colour for earth continuity
of following size. (a) with medium class
Rigid PVC pipe and accessories.
(a) 2 wire 1.5 sq. mm.
(b) 2 wire 2.5 sq. mm.
(c) 3 wire 1.5 sq. mm
(d) 3 wire 2.5 sq. mm
(e) 4 wire 1.5 sq. mm
F 1.00 (f) 4 wire 2.5 sq. mm Rmt
(g) 6 wire 2.5 sq. mm
Supplying & erecting Delton or approved
make Telephone Cable electrolytic copper
conductor PE insulation twisted in two pairs,
& wrapped with FRLS PVC tape & sheathed
with FRLS PVC or HFFR outer Jacket suitable
for telephone wiring & confirming to C-DOT
erected in existing pipe. of following
size of conductors & nos.of pairs. With
necessary connections. (N.S.) [A] Conductor
Size 0.5 mm (a) Unarmoured
Call bell point with push button switch
Providing following type of Modular Type
Accessories mounted with pvc / metallic box,
single mounting base frame covered with
textured / metallic front plate , modules
erected with necessary connection.
As desired by Engineer Incharge
(1)One No. SP 6 Amp. Cat.III
(2) One No 5 pin plug.Cat. III
(9) 16 Amp. SP one way switch.Cat.III
(10) 6/16Amp. Universal
socket.Cat.III 200.00
Supply, Installation, testing and
commissioning of Surface mounted
light fixture suitable for 2 X 18 W luminaire
along with all other necessary
9 1.00 accessories. (PHILIPS / Equlent Cat :-Green No.
LED Square, type:
910403630906,Product descrption : BBS182
1XDLED- 5000 PSU WH) BASIC PRICE:
Supply , Installation, testing and
commissioning of pre-wired, fluorescent
fitting / compact fluorescent fitting/LED
fitting/MH fitting/post top luminaries etc of all
types, complete with all accessories
and tube etc. directly on ceiling/ wall,
including connection with 1.5 sq. mm FRLS PVC
insulated, flexible, copper conductor, single
core cable with flexible conduits and coupler
and earthing etc. as required
Supply,Installation,Testing and
Commissioning of 2'X2' LED LIGHT
PANEL of following Cat No. (1) RECESS
MOUNTING :- Philips RC 365B /
Crompton LCPL-36-CDL /Bajaj BZRS QL
W XL / Wipro LM17-411--XXX-XX- XX- 40 W
(2) SURFACE MOUNTING :- Philips SM 5,800.00
365C / Crompton LCPL-36-CDL / Bajaj
BZSSQL X 36 W XL / Wipro LM17-411--XXX-
XX-XX- 40 W Contractor has to supply
Colour i.e. Warm white/ Cool White as
per Client requirement.
Supplying & erecting 1 X 20W surface
mounted LED Patti light fixture with driver
and all accessories as approved by client /
11 5.00 consultant. (Ref make- PHILIPS make TMS No
501 / 1 x TLED 20w Luminaire suitable for
TLED 20w with 20w LED Tube) or equivalent of
Supply and erecting integral flood light with
driver inside a PDC housing Philips make
UNIFLOOD Cat.no: BVP120LED 70CWNB FG 9,890.00
S1 PSU GR or equivalent of Wipro or LG make
Supply, Installation, testing and
commissioning of Surface mounted
13 5.00 light fixture suitable for 2 X 18 W luminaire No.
along with all other necessary
accessories. Brand approved by eng. inch.)
Providing & erecting Approved make
Power Saving 50 Watt Ceiling Fan with
double ball bearing ISI mark with Condenser
230 volt A.C. 50 Hz 1200 mm sweep
complete having 3blades with aluminium
blades with , canopy & suitable lenght of 2,070.00
down rod erected with 24/ 0.2, 3 core flexible
wire with earthing.(Make shall be approved
by Engineer in charge))Orient energy star,
Havells ES-50,Crompton high speed +
Supplying and erecting approved make
oscillating type bracket fan A.C. 23OV. 50cy/s
400/450 mm sweep wall mounted with height
15 5.00 adjustment and rotary tilting device complete No
with guard, flexible Core plug top complete
erected with lead wires as directed.( Crompton,
Usha, Orient make only )
Supplying & erecting approved make low
noise decorative exhaust fan having size
16 5.00 200mm with 1350 RPM with square frame ABS No
body with inbuilt lowers & square
frame.(Crompton , USHA make only )
Providing and erecting 3 star and approved
make split air-cond consisting of
condensing unit wit hermetically sealed
rotary com accessories etc. duly
connecte erected evaporating unit and blower
17 5.00 accessories by means of proper ins tubing up No
to 5 RMT suitable for ( M.S. Stand, Gas
Charging & Int Wiring & Remote Control)
Makes :-3 of DAIKIN/O GENERAL / TR
/MITSUBISHI AND 5-star model of with cu
condensor for (b) 1.5 ton cap
Extra charges for the Items beyond standard
length For Single phase Split A.C. Machine
18 5.00 insulated pair of soft, copper tubing including Rmt
power and control cable up to 1.5 TR
Providing Approved make Triple Pole Metal
Clad Switch Fuse Unit 415/500 V. with HRC
fuse of suitable load and neutral link 6,790.00
confirming to IS 100 A/125 A
Approved make ELCBs / RCCBs conforming
to IS: 12640 and having sensitivity of
mA and Short Circuit withstand capacity of
KA and suitable for operation on single phase
20 1.00 240 V. having characteristic of quick Ea.
action & tripping with all advance feature & do
not incorporate any electronic component.
for following Max. rating erected as
directed (ii) 40Amps. DP Cat. III
Providing and erecting Sheet Steel powder
coated MCB distribution board - flush /
surface mounted fitted with busbar, neutral
link, earth bar and DIN rail, confirming to IS
21 1.00 13032 and BS 5486-1986 without MCB to Ea.
house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to be
used) (L) Three phase 6 way SS Double door
for single phase outgoing horizontal box
Providing Approved make Triple Pole Metal
Clad Switch Fuse Unit 415/500 V. with HRC
fuse of suitable load and neutral link 9,360.00
confirming to IS (a)200 A Cat.III
Existing A.C. Removing
Dismantling Existing Cup board
Dismantling of Necessary Existing Electrical
works 20,000.00
Primary light points controlled by one 6A
switch 1,350.00
27 1.00 Secondary light points controlled by one 6A No.
Supply, fixing, connection and testing of
5-pin 16 A power plug socket alongwith 16A
28 10.00 switch with top cover plate, PVC back box No.
suitable for modular plate with all accessories
to complete the job. (N.S.)
Supply, fixing, connection and testing of
5-pin 6 A power plug socket alongwith 6A
switch with top cover plate, PVC back box
suitable for modular plate with all accessories
to complete the job. A point shall include in
addition to phase & neutral wire, earth
continuity wire from LDB to the final
termination at outlet points.All the wiring, outlet
29 20.00 points shall be done in a surface / No.
concealed manner with ISI approved medium
duty, rigid FR PVC, ISI conduit of minimum
25 mm. dia. using 650 V FRLS copper
conductor wire. Supply and installation of
Modular switches with suitable plate, PVC
back box with brass chromium / cadmium
plated machine screws etc. shall be part of job.
Providing & Fixing Alluminium Composite
Panel of approved make of 4 mm thick
Exterior Grade PVDF with coil thickness
mm & Frame work made out from
Alluminium anodised section of size 50x25
mm ( weight approx. :0.57 kg./mtr.) having
weight of 2.6 kg. for 15'-0 supported 3,500.00
on Masonary/ R.C.C. with the help of MS
bracket fixed with Brick Fastener /
Anchor Fastener & Groove Filled with
weather fillent of Dowl corning corporation
Point wiring for Light / Fan/ Bell/ Primary Point
with 2-1.5 sq. mm & earth wire of 1.5 sq. mm
(green) both are of ISI marked 1.1 kv grade
FRLS PVC insulated multi strand copper wires
upto max length of 10 mt, in below type of pipe
31 erected with 6A Tissino Type ISI marked flush
type switch / bell push and accessories erected
on Metal / PVC/Wooden Box covered with
mm thick PC(Polycarbonate) /Acrylic/Laminated
sheet. with necessary Lamp holder/ceiling rose /
H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and
1.00 accessories erected flushed on wall/ceiling Pt
(b) with 16 swg(1.6 mm thick) HGS metal
1.00 conduit pipe and accessories painted black Pt.
erected flushed on wall/ceiling complete
( c) with oval conduit /PVC casing capping
1.00 double lock type erected flushed on wall/ceiling Pt.
(d) partial PVC pipe and drops in oval conduit /
1.00 PVC casing capping erected flushed on Pt.
wall/ceiling complete
(e) in existing pipe erected flushed on
wall/ceiling complete 264.00
(f) with medium class Rigid PVC pipe and
1.00 accessories erected concealed in wall/ceiling Pt
(g) with 16 swg(1.6 mm thick) HGS metal
1.00 conduit pipe and accessories painted black Pt.
erected concealed in wall/ceiling complete
( h) with oval conduit /PVC casing capping
1.00 double lock type erected concealed in Pt.
wall/ceiling complete
(i) partial PVC pipe and drops in oval conduit /
1.00 PVC casing capping erected concealed in Pt.
wall/ceiling complete
(j) in existing pipe erected erected concealed in
wall/ceiling complete 296.00
Point wiring for independent PLUG with following
size mains earth wire of 1.5 sq.mm (green) both
are of ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires upto 10 mt
length, in following below of pipe erected
complete with ISI marked 3 / 5 Pin socket and -
tissino type switch erected with earth continuity
connection erected on Metal / PVC/Wooden box
covered with 3 mm thick PC(Polycarbonate) /
Acrylic/Laminated sheet.
[A] For 6 amp plug and 6 amp switch with 2-1.5
(A) sq. mm Cu. Mains from near by switchboard/db
board upto 6 mt.
(a) with medium class Rigid PVC pipe and
1.00 accessories erected flushed on wall/ceiling Pt.
(b) with 16 swg(1.6 mm thick) HGS metal
1.00 conduit pipe and accessories painted black Pt.
erected flushed on wall/ceiling complete
( c) with oval conduit /PVC casing capping
1.00 double lock type erected flushed on wall/ceiling Pt.
(d) partial PVC pipe and drops in oval conduit /
1.00 PVC casing capping erected flushed on Pt.
wall/ceiling complete
(e) in existing pipe erected flushed on
wall/ceiling complete 231.00
(f) with medium class Rigid PVC pipe and
1.00 accessories erected concealed in wall/ceiling Pt.
(g) with 16 swg(1.6 mm thick) HGS metal
1.00 conduit pipe and accessories painted black Pt.
erected concealed in wall/ceiling complete
( h) with oval conduit /PVC casing capping
1.00 double lock type erected concealed in Pt.
wall/ceiling complete
(i) partial PVC pipe and drops in oval conduit /
1.00 PVC casing capping erected concealed in Pt.
wall/ceiling complete
(j) in existing pipe erected erected concealed in
wall/ceiling complete 263.00
[B] 6/16A Plug and 16 amp switch with 2-2.5 sq.
mm Cu. Mains from mcb d b boards. -
(a) with medium class Rigid PVC pipe and
1.00 accessories erected flushed on wall/ceiling Pt.
(b) with 16 swg(1.6 mm thick) HGS metal
1.00 conduit pipe and accessories painted black Pt.
erected flushed on wall/ceiling complete
(c) with oval conduit /PVC casing capping double
1.00 lock type erected flushed on wall/ceiling Pt.
(d) partial PVC pipe and drops in oval conduit /
1.00 PVC casing capping erected flushed on Pt.
wall/ceiling complete
(e) in existing pipe erected flushed on
wall/ceiling complete 331.00
(f) with medium class Rigid PVC pipe and
1.00 accessories erected concealed in wall/ceiling Pt.
(g) with 16 swg(1.6 mm thick) HGS metal
1.00 conduit pipe and accessories painted black Pt.
erected concealed in wall/ceiling complete
(h) with oval conduit /PVC casing capping
1.00 double lock type erected concealed in Pt.
wall/ceiling complete
(i) partial PVC pipe and drops in oval conduit /
1.00 PVC casing capping erected concealed in Pt.
wall/ceiling complete
(j) in existing pipe erected erected concealed in
wall/ceiling complete 363.00
[C] 6/16A Plug and 16 A switch with 2-4 sq.mm
34 Cu. Mains with 2.5 sq.mm ( green) earthing wire -
(a) with medium class Rigid PVC pipe and
1.00 accessories erected flushed on wall/ceiling Pt.
(b) with 16 swg(1.6 mm thick) HGS metal
1.00 conduit pipe and accessories painted black Pt.
erected flushed on wall/ceiling complete
(c) with oval conduit /PVC casing capping double
1.00 lock type erected flushed on wall/ceiling Pt.
(d) partial PVC pipe and drops in oval conduit /
1.00 PVC casing capping erected flushed on Pt.
wall/ceiling complete
(e) in existing pipe erected flushed on
wall/ceiling complete 453.00
(f) with medium class Rigid PVC pipe and
1.00 accessories erected concealed in wall/ceiling Pt.
(g) with 16 swg(1.6 mm thick) HGS metal
1.00 conduit pipe and accessories painted black Pt.
erected concealed in wall/ceiling complete
(h) with oval conduit /PVC casing capping
1.00 double lock type erected concealed in Pt.
wall/ceiling complete
(i) partial PVC pipe and drops in oval conduit /
1.00 PVC casing capping erected concealed in Pt.
wall/ceiling complete
(j) in existing pipe erected erected concealed in
wall/ceiling complete 484.00
Point wiring for on board looped PLUG with
tissino type single pole ISI marked Switch and
Socket erected with necessary connections
35 erected on wooden /Metal/ PVC Box covered
with 3 mm thick PC(Polycarbonate) /Acrylic
sheet for open / concealed wiring for following
[B] For 16 Amp.
Point wiring for secondary light point with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (green) both
are of ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires, in below
type of pipe to be erected complete with earth
36 continuity and necessary connection with
primary light with accessories erected on Metal /
PVC / wooden box covered with 3 mm thick
PC(Polycarbonate) / Acrylic sheet for open /
concealed wiring. with necessary Lamp holder /
ceiling rose / H.D.Connector as directed.
Note:- Maximum up to 6 mtrs length, excess will
be considered as Mains for Secondary Point. -
(a) with medium class Rigid PVC pipe and
1.00 accessories erected flushed on wall/ceiling Pt.
(b) with 16 swg(1.6 mm thick) HGS metal
1.00 conduit pipe and accessories painted black Pt.
erected flushed on wall/ceiling complete
(c) with oval conduit /PVC casing capping double
1.00 lock type erected flushed on wall/ceiling Pt.
(d) partial PVC pipe and drops in oval conduit /
1.00 PVC casing capping erected flushed on Pt.
wall/ceiling complete
(e) in existing pipe erected flushed on
wall/ceiling complete 83.00
(f) with medium class Rigid PVC pipe and
1.00 accessories erected concealed in wall/ceiling Pt.
(g) with 16 swg(1.6 mm thick) HGS metal
1.00 conduit pipe and accessories painted black Pt.
erected concealed in wall/ceiling complete
(h) with oval conduit /PVC casing capping
1.00 double lock type erected concealed in Pt.
wall/ceiling complete
(i) partial PVC pipe and drops in oval conduit /
1.00 PVC casing capping erected concealed in Pt.
wall/ceiling complete
(j) in existing pipe erected erected concealed in
wall/ceiling complete 114.00
Point wiring for Two Way Controlled Light Point
with 2-1.5 sq.mm & earth wire of 1.5 sq.mm
(green) both are of ISI marked 1.1 KV grade
FRLS PVC insulated multi strand copper wires
up to 10 mtr length, in following type of pipe to
be erected concealed in / flushed on wall /
ceiling complete with 6A Tissino Type ISI -
marked accessories with earth continuity erected
on Metal/PVC//Wooden box covered with 3 mm
thick PC(Polycarbonate) / Acrylic sheet. with
necessary Lamp holder/ceiling rose /
H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and
1.00 accessories erected flushed on wall/ceiling Pt.
(b) with 16 swg(1.6 mm thick) HGS metal
1.00 conduit pipe and accessories painted black Pt.
erected flushed on wall/ceiling complete
(c) with oval conduit /PVC casing capping double
1.00 lock type erected flushed on wall/ceiling Pt.
(d) partial PVC pipe and drops in oval conduit /
1.00 PVC casing capping erected flushed on Pt.
wall/ceiling complete
(e) in existing pipe erected flushed on
wall/ceiling complete 287.00
(f) with medium class Rigid PVC pipe and
1.00 accessories erected concealed in wall/ceiling Pt.
(g) with 16 swg(1.6 mm thick) HGS metal
1.00 conduit pipe and accessories painted black Pt.
erected concealed in wall/ceiling complete
(h) with oval conduit /PVC casing capping
1.00 double lock type erected concealed in Pt.
wall/ceiling complete
(i) partial PVC pipe and drops in oval conduit /
1.00 PVC casing capping erected concealed in Pt.
wall/ceiling complete
(j) in existing pipe erected erected concealed in
wall/ceiling complete 319.00
Point wiring for Light / Bell with 2-1.5 sq.mm &
earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length , in
below type of pipe erected with 6A Modular type
switch / bell push & accessories and earth
continuity of following type, erected on PVC /
Metallic/Wooden box, single mounting base
frame covered with textured/metallic/white front
plate modules erected on / in wall / ceiling as
per pipe erected, with necessary Lamp
holder/ceiling rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling
(b) with 16 swg HGS metal conduit pipe and
accessories painted black erected flushed on
wall/ceiling complete
(c) with oval conduit /PVC casing capping double
lock type erected flushed on wall/ceiling
(d) partial PVC pipe and drops in oval conduit /
PVC casing capping erected flushed on
wall/ceiling complete
(e) in existing pipe erected flushed on
wall/ceiling complete -
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
(g) with 16 swg HGS metal conduit pipe and
accessories painted black. erected concealed in
wall/ceiling complete
(h) with oval conduit /PVC casing capping
double lock type erected concealed in
wall/ceiling complete
(i) partial PVC pipe and drops in oval conduit /
PVC casing capping erected concealed in
wall/ceiling complete
(j) in existing pipe erected concealed in
wall/ceiling complete -
Point wiring for FAN with 2-1.5 sq.mm & earth
wire of 1.5 sq.mm (Green) both are of .ISI
marked 1.1 KV Grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in
below type of pipe erected with 6A Modular
type switch and hum free EME step type
electronic fan regulator mounted and
accessories with earth continuity of following
type erected on PVC / Metallic/Wooden box,
single mounting base frame covered with
textured/metallic/white front plate modules
erected on / in wall / ceiling as per pipe erected.
with necessary ceiling rose / H.D.Connector as
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling
(b) with 16 swg HGS metal conduit pipe and
accessories painted black erected flushed on
wall/ceiling complete
(c) with oval conduit /PVC casing capping double
lock type erected flushed on wall/ceiling
(d) partial PVC pipe and drops in oval conduit /
PVC casing capping erected flushed on
wall/ceiling complete
(e) in existing pipe erected flushed on
wall/ceiling complete -
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
(g) with 16 swg HGS metal conduit pipe and
accessories painted black. erected concealed in
wall/ceiling complete
(h) with oval conduit /PVC casing capping
double lock type erected concealed in
wall/ceiling complete
(i) partial PVC pipe and drops in oval conduit /
PVC casing capping erected concealed in
wall/ceiling complete
(j) in existing pipe erected concealed in
wall/ceiling complete -
Point wiring for Individual Plug with & earth wire
of 1.5 sq.mm (Green) both are of ISI marked
KV grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below type
of pipe erected complete with Modular type
switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate
front plate modules erected on / in wall / ceiling
as per pipe erected with following type of
[I] For 6A Plug and 6 a switch with 2-1.5 sq.mm
(I) Cu. Wire from nearby switchboard/mcb db board
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling
(b) with 16 swg HGS metal conduit pipe and
accessories painted black erected flushed on
wall/ceiling complete
(c) with oval conduit /PVC casing capping double
lock type erected flushed on wall/ceiling
(d) partial PVC pipe and drops in oval conduit /
PVC casing capping erected flushed on
wall/ceiling complete
(e) in existing pipe erected flushed on
wall/ceiling complete -
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
(g) with 16 swg HGS metal conduit pipe and
accessories painted black. erected concealed in
wall/ceiling complete
(h) with oval conduit /PVC casing capping
double lock type erected concealed in
wall/ceiling complete
(i) partial PVC pipe and drops in oval conduit /
PVC casing capping erected concealed in
wall/ceiling complete
(j) in existing pipe erected concealed in
wall/ceiling complete -
[II] For 16A Plug and 16 amp switch with 2-2.5
sq.mm Cu. Wire from mcb db board.
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling
(b) with 16 swg HGS metal conduit pipe and
accessories painted black erected flushed on
wall/ceiling complete
(c) with oval conduit /PVC casing capping double
lock type erected flushed on wall/ceiling
(d) partial PVC pipe and drops in oval conduit /
PVC casing capping erected flushed on
wall/ceiling complete
(e) in existing pipe erected flushed on
wall/ceiling complete -
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
(g) with 16 swg HGS metal conduit pipe and
accessories painted black. erected concealed in
wall/ceiling complete
(h) with oval conduit /PVC casing capping
double lock type erected concealed in
wall/ceiling complete
(i) partial PVC pipe and drops in oval conduit /
PVC casing capping erected concealed in
wall/ceiling complete
(j) in existing pipe erected concealed in
wall/ceiling complete -
[III] For 16A Plug and 16 amp switch with 2-4
(III) sq.mm Cu. Wire with 2.5 sq.mm ( green)
earthing wire from mcb d b board.
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling
(b) with 16 swg HGS metal conduit pipe and
accessories painted black erected flushed on
wall/ceiling complete
(c) with oval conduit /PVC casing capping double
lock type erected flushed on wall/ceiling
(d) partial PVC pipe and drops in oval conduit /
PVC casing capping erected flushed on
wall/ceiling complete
(e) in existing pipe erected flushed on
wall/ceiling complete -
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
(g) with 16 swg HGS metal conduit pipe and
accessories painted black. erected concealed in
wall/ceiling complete
(h) with oval conduit /PVC casing capping
double lock type erected concealed in
wall/ceiling complete
(i) partial PVC pipe and drops in oval conduit /
PVC casing capping erected concealed in
wall/ceiling complete
(j) in existing pipe erected concealed in
wall/ceiling complete -
Point wiring for on board Looped Plug with 6A
Modular type switch & 5 pin socket erected on
PVC / Metallic/Wooden box, single mounting
base frame covered with textured / metallic/white
front plate modules erected on / in wall / ceiling
with following type accessories
1.00 Cat. I Pt.
Point wiring for Two Way Controlled Light Point
with 2-1.5 sq.mm & earth wire of 1.5 sq.mm
(green) both are of .ISI marked 1.1 KV grade
FRLS PVC insulated multi strand copper wires
erected in below type of pipe with 6A Modular
type switches and following type of accessories
erected on PVC / Metallic/Wooden box, single
mounting base frame covered with textured /
metallic/white front plate modules erected on / in
wall / ceiling as per pipe erected. with necessary
batten/angle holder or ceiling rose or
H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling
(b) with 16 swg HGS metal conduit pipe and
accessories painted black erected flushed on
wall/ceiling complete
(c) with oval conduit /PVC casing capping double
lock type erected flushed on wall/ceiling
(d) partial PVC pipe and drops in oval conduit /
PVC casing capping erected flushed on
wall/ceiling complete
(e) in existing pipe erected flushed on
wall/ceiling complete -
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
(g) with 16 swg HGS metal conduit pipe and
accessories painted black. erected concealed in
wall/ceiling complete
(h) with oval conduit /PVC casing capping
double lock type erected concealed in
wall/ceiling complete
(i) partial PVC pipe and drops in oval conduit /
PVC casing capping erected concealed in
wall/ceiling complete
(j) in existing pipe erected concealed in
wall/ceiling complete -
Point wiring for secondary light point with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (green) both
are of ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires, in below
type of pipe to be erected complete with earth
continuity and necessary connection with
43 1-2-6 primary light with accessories erected on Metal /
PVC / wooden box covered covered with
appropriate front plate modules erected on / in
wall / ceiling for open / concealed wiring. with
necessary Lamp holder / ceiling rose /
H.D.Connector as directed.as per pipe erected
with following type of accessories.
Note:- Maximum up to 6 mtrs length, excess will
be considered as Mains for Secondary Point. -
(a) with medium class Rigid PVC pipe and
1.00 accessories erected flushed on wall/ceiling Pt.
(b) with 16 swg(1.6 mm thick) HGS metal
1.00 conduit pipe and accessories painted black Pt.
erected flushed on wall/ceiling complete
( c) with oval conduit /PVC casing capping
1.00 double lock type erected flushed on wall/ceiling Pt.
(d) partial PVC pipe and drops in oval conduit /
1.00 PVC casing capping erected flushed on Pt.
wall/ceiling complete
(e) in existing pipe erected flushed on
wall/ceiling complete 83.00
(f) with medium class Rigid PVC pipe and
1.00 accessories erected concealed in wall/ceiling Pt.
(g) with 16 swg(1.6 mm thick) HGS metal
1.00 conduit pipe and accessories painted black Pt.
erected concealed in wall/ceiling complete
( h) with oval conduit /PVC casing capping
1.00 double lock type erected concealed in Pt.
wall/ceiling complete
(i) partial PVC pipe and drops in oval conduit /
1.00 PVC casing capping erected concealed in Pt.
wall/ceiling complete
(j) in existing pipe erected erected concealed in
wall/ceiling complete 114.00
Providing following type of Modular Type
Accessories mounted with PVC /
metallic/Wooden box, single mounting base
44 1-2-7. frame covered with textured / metallic/white front
plate , modules erected with necessary
connections as per site situation directed by
Engineer In charge.
(1)One No. SP 6 Amp.
(2) One No 5 pin plug
(3) Two Pin/RJ-11 Telephone Socket
[A] For One Gang
[B] For Two Gang
(4) TV Co-axial Socket outlet
(5) Electronic hum Free steps EME Fan
(6) Fuse units 10Amp. or 16 Amp.
(7) Blank Plate Single
(8) Computer RJ-45 socket
(9) 16 Amp. SP one way switch
(10) 6/16Amp. Universal socket
(11) 6 Amps. Bell Push
(12) 6Amp. / 16 Amp. Two Way switch
(13) 6A/10A/16A/20A/25A/32A Single pole
Modular MCB Switch -
(14) 6A/ 10A/ 16A/ 20A/ 25A/ 32A Double Pole
Modular MCB Switch -
(15) 32 Amps. DP switch with Indicator
(16) 32 Amp. DP Main Switch Operating with
Energy Key Tag -
(17-a) For 400W / 450 watt One Module
Electronic Dimmer -
(17-b) For 600 / 650 watt Two module Electronic
(17-c) For 1000 watt two module Electronic
(18) 13 Amp. International Modular Socket
(19) Modular Indicating Call Bell
(20) Modular Buzzer
(21) Foot Light as per colour requirement with
concealed box, modular accessories, acrylic
glass cover with suitable LED watt with all -
accessories as per following module
(a) Two modules
1.00 Cat-III Ea.
(b) Four modules
1.00 Cat-III Ea.
(c) Six modules
1.00 Cat-III Ea.
(22) 16/20/25 Amp. Modular Starter for Motor /
A.C. Unit Complete -
(23) USB Charger with output of 5 V DC,2.1 A
1.00 with inbuilt surge protection. Ea
(24) Batten Holder/Angle Holder with modular
1.00 frame with metal ring. Ea
Providing & erecting following type of Modular
45 Type Accessories with necessary connection. As
desired by Engineer In charge
(1) 6 Amp. SP one way switch
(2) 16 Amp. SP one way switch
(3) 6/16Amp. Universal socket
(5) LAN cable connector with ferule
Providing D type non rechargeable carbon zinc
type Cell 1.5v of desired make suitable as
demanded by engineer in charge 34.00
evereday,panasonic,nippo make
Providing AA type 1.5 v non rechargeable Cell
47 of desired make as demanded by engineer in
(a)Carbon-zinc evereday,panasonic,nippo make
(b)Alkaline -Dura cell make
Providing AAA type 1.5 v Cell of desired make
as demanded by engineer in charge -
(a)Carbon-zinc evereday,panasonic,nippo make
(b)Alkaline -Dura cell make
Providing 9v Cell of desired make as demanded
by engineer in charge -
(a)Hiwatt/evereday/panasonic
(b)Ultra alkaline -Dura cell make
For Laying of Pipes on Stone Wall add to the
following item rate per meter 11.00
Providing and erecting ISI mark Medium class
RIGID PVC PIPES of following size complete to
be erected on/in wall or ceiling erected with
necessary PVC fittings & Junction boxes fixed
with adhesive solution & Clamps with following
dia of pipes, in approved manner as directed
Providing & erecting approved make OVAL
CONDUIT with necessary fittings fixed with
adhesive solution and suitable clamps erected
on wall / ceiling of following size.
Providing & erecting PVC Corrugated Flexible
Conduit with required nos. of coupling, PVC
bushes, Check-nuts etc. complete of following
Supplying & erecting UPVC Mini trunking (PVC
Casing-n-Capping) having double-locking
arrangement with grooves, trunking of size not
54 below 12.5 mm in height as per IS with
accessories of PVC/Resin polypropylene not
below 1.8 mm thick duly sealed in joint & erected
on wall / ceiling of following size .
Providing and erecting Mains with 1.1 KV grade
FRLS PVC insulated ISI marked stranded
Copper conductor wire in following type of pipe
55 to be erected concealed in /flushed on
wall/ceiling, with 1.5 sq. mm copper conductor
FRLS PVC insulated stranded wire of green
colour for earth continuity of following size
(A) With medium class Rigid PVC pipe and
1.00 (a) 2 wire 1.5 sq. mm Mtr.
(b) 2 wire 2.5 sq. mm
(c) 3 wire 1.5 sq. mm
(d) 3 wire 2.5 sq. mm
(e) 4 wire 1.5 sq. mm
(f) 4 wire 2.5 sq. mm
(g) 6 wire 2.5 sq. mm
(B) With 16 swg HGS metal conduit pipe and
accessories painted black.
(a) 2 wire 1.5 sq. mm
(b) 2 wire 2.5 sq. mm
(c) 3 wire 1.5 sq. mm
(d) 3 wire 2.5 sq. mm
(e) 4 wire 1.5 sq. mm
(f) 4 wire 2.5 sq. mm
(g) 6 wire 2.5 sq. mm
(C) With oval conduit /PVC casing capping
double lock type
(a) 2 wire 1.5 sq. mm
(b) 2 wire 2.5 sq. mm
(c) 3 wire 1.5 sq. mm
(d) 3 wire 2.5 sq. mm
(e) 4 wire 1.5 sq. mm
(f) 4 wire 2.5 sq. mm
(g) 6 wire 2.5 sq. mm
(D) Partial PVC pipe and drops in oval conduit /
PVC casing capping
(a) 2 wire 1.5 sq. mm
1.00 (b) 2 wire 2.5 sq. mm Mtr.
(c) 3 wire 1.5 sq. mm
(d) 3 wire 2.5 sq. mm
(e) 4 wire 1.5 sq. mm
(f) 4 wire 2.5 sq. mm
(g) 6 wire 2.5 sq. mm
(E) (E) in existing pipe
(a) 2 wire 1.5 sq. mm
(b) 2 wire 2.5 sq. mm
(c) 3 wire 1.5 sq. mm
(d) 3 wire 2.5 sq. mm
(e) 4 wire 1.5 sq. mm
(f) 4 wire 2.5 sq. mm
(g) 6 wire 2.5 sq. mm
providing and erecting Mains with 1.1 KV grade
FRLS PVC insulated ISI marked stranded
Copper conductor wire in following type of pipe
56 to be erected in / on wall / ceiling with 2.5 sq.
mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity
of following size
(A) with medium class Rigid PVC pipe and
(a) 2 wire 4 sq. mm
(b) 2 wire 6 sq. mm
(c) 2 wire 10 sq. mm
1.00 (use earth wire of 4 sq.mm ) Mtr.
(d) 3 wire 4 sq. mm
(e) 3 wire 6 sq. mm
(f) 3 wire 10 sq. mm
1.00 (use earth wire of 4 sq.mm ) Mtr.
(g) 4 wire 4 sq. mm
(h) 4 wire 6 sq. mm
(i) 4 wire 10 sq. mm
1.00 (use earth wire of 4 sq.mm ) Mtr.
(B) with 16 swg HGS metal conduit pipe and
accessories painted black.
(a) 2 wire 4 sq. mm
(b) 2 wire 6 sq. mm
(c) 2 wire 10 sq. mm
1.00 (use earth wire of 4 sq.mm ) Mtr.
(d) 3 wire 4 sq. mm
(e) 3 wire 6 sq. mm
(f) 3 wire 10 sq. mm
1.00 (use earth wire of 4 sq.mm ) Mtr.
(g) 4 wire 4 sq. mm
(h) 4 wire 6 sq. mm
(i) 4 wire 10 sq. mm
1.00 (use earth wire of 4 sq.mm ) Mtr.
(C) with oval conduit /PVC casing capping
double lock type
(a) 2 wire 4 sq. mm
(b) 2 wire 6 sq. mm
(c) 2 wire 10 sq. mm
1.00 (use earth wire of 4 sq.mm ) Mtr.
(d) 3 wire 4 sq. mm
(e) 3 wire 6 sq. mm
(f) 3 wire 10 sq. mm
1.00 (use earth wire of 4 sq.mm ) Mtr.
(g) 4 wire 4 sq. mm
(h) 4 wire 6 sq. mm
(i) 4 wire 10 sq. mm
1.00 (use earth wire of 4 sq.mm ) Mtr.
(D) partial PVC pipe and drops in oval conduit /
PVC casing capping
(a) 2 wire 4 sq. mm
1.00 (b) 2 wire 6 sq. mm Mtr.
(c) 2 wire 10 sq. mm
1.00 (use earth wire of 4 sq.mm ) Mtr.
(d) 3 wire 4 sq. mm
(e) 3 wire 6 sq. mm
(f) 3 wire 10 sq. mm
1.00 (use earth wire of 4 sq.mm ) Mtr.
(g) 4 wire 4 sq. mm
(h) 4 wire 6 sq. mm
(i) 4 wire 10 sq. mm
1.00 (use earth wire of 4 sq.mm ) Mtr.
(E) (E) in existing pipe -
(a) 2 wire 4 sq. mm
(b) 2 wire 6 sq. mm
(c) 2 wire 10 sq. mm
1.00 (use earth wire of 4 sq.mm ) Mtr.
(d) 3 wire 4 sq. mm
(e) 3 wire 6 sq. mm
(f) 3 wire 10 sq. mm
1.00 (use earth wire of 4 sq.mm ) Mtr.
(g) 4 wire 4 sq. mm
(h) 4 wire 6 sq. mm
(i) 4 wire 10 sq. mm
1.00 (use earth wire of 4 sq.mm ) Mtr.
providing and erecting Mains with ISI marked
electrolyte stranded copper conductor, Non PVC
Zero Halogen free fire retardant insulated copper
57 conductor, insulated wire (HRFR) conforms to
IS-694, erected in existing pipe with 1.5sq. mm
copper conductor of same specifications for
earth continuity of following size.
[a] 2wire 0.75 sq.mm (w/o ECC)
[b] 2 wire 1.0 sq.mm (w/o ECC)
[c] 2 wire 1.5 sq.mm
[d] 2 wire 2.5 sq.mm
[e] 2 wire 4.0 sq.mm
[f] 2 wire 6.0 sq.mm
[g] 2 wire 10.0 sq.mm
[h] 3 wire 1.0 sq.mm
[i] 3 wire 1.5 sq.mm
[j] 3 wire 2.5 sq.mm
[k] 3 wire 4.0 sq.mm
[l] 4 wire 1.0 sq.mm
[m] 4 wire 1.5 sq.mm
[n] 4 wire 2.5 sq.mm
[o] 4 wire 4.0 sq.mm
providing and erecting Mains with ISI marked,
1.5KV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC
insulated conforms to IS 694, IEC - 227 erected
in existing pipe of following size (Specifically for -
control panel, relays, power switchgears, motor
starters & control wiring) with required size of
copper lugs, nuts and bolts if required.
(a) One wire 1.00 sq. mm
(b) One wire 1.50 sq. mm
(c) One wire 2.50 sq. mm
(d) One wire 4.00 sq. mm
(e) One wire 6.00 sq. mm
(f) One wire 10.00 sq. mm
(g) One wire 16.00 sq. mm
(h) One wire 25.00 sq. mm
(i) One wire 35.00 sq. mm
(j) One wire 50.00 sq. mm
(k) One wire 70.00 sq. mm
(l) One wire 95.00 sq. mm
(m) One wire 120.00 sq. mm
(n) One wire 150.00 sq. mm
Supplying and erecting Flexible PVC insulated
multi strand multi core 1.1 kv grade ISI marked
copper wires of following size to be erected as -
(a) 0.75 Sq.mm twin twisted
(b) 1.00 Sq.mm twin twisted
(c) 1.00 Sq.mm 2 core round/ flat PVC sheathed
(d) 1.50 Sq.mm 2 core round PVC sheathed
(e) 1.50 Sq.mm 3 core round PVC sheathed
(f) 1.50 Sq.mm 4 core round PVC sheathed
(g) 2.50 Sq.mm 2 core round PVC sheathed
(h) 2.50 Sq.mm 3 core round PVC sheathed
(i) 2.50 Sq.mm 4 core round PVC sheathed
(j) 4.00 Sq.mm 3 core round PVC sheathed
(k) 4.00Sq.mm 4 core round PVC sheathed
Providing & Erecting approved make following
size of TV Co-axial flexible cable comprising
inner conductor of solid bare copper insulated
60 with Foam PE & Secondary conductor made of
poly - Aluminium film bonded Al. Braids @
suitable coverage overall sheathed with black
PVC insulation.
(d) RG - 11 CCS
Supplying & erecting approved make Telephone
Cable electrolytic copper conductor PE
insulation twisted in two pairs, & wrapped with
FRLS PVC tape & sheathed with FRLS PVC or
HFFR outer Jacket suitable for telephone wiring -
& confirming to C-DOT erected in existing pipe.
of following size of conductors & nos.of pairs.
With necessary connections.
[A] Conductor Size 0.5 mm
(3) Three Pairs
(6) Twenty Pairs
(b) Armoured [Jelly Filled]
(2) Twenty Pairs
(3) Fifty Pairs
(4) One Hundred Pairs
Supplying & erecting approved make LAN cable
62 of following size in existing pipe as per direction -
[E] CAT - 6 shielded
Providing & erecting main Distribution (MDF)
63 indoor type, back mounted frame as per DoT
standard approved with krone strips
(a) Suitable for 10 pair
(b) Suitable for 20 pair
(c) Suitable for 50 pair
(d) Suitable for 100 pair
(e) Suitable for 200 pair
Providing & Erecting 6 core fibre optic SM
64 1.00 9/125um double sheath, CSTA, Unitube, Rmtr.
Outdoor cable (per m)
Providing & Erecting following Shockproof
tissino type accessories erected on 3 mm thick
PC (Polycarbonate) sheet in PVC/ -
Metal/Wooden Box. erected on wall/ ceiling.
(1) One no Single pole 6 A Switch / Bell push
(2) One no 3/5 pin 6 A Socket
(3) One no Single pole 16 A Switch
(4) One no 6/16 A Universal Socket
(5) One no Single pole 16 A Switch & One no
6/16 A Universal Socket combined 105.00
(6) One no Single pole 16 A Switch & One no
1.00 6A/16A Universal Socket combined with Ea.
indicator & fuse
(7) Bakelite ceiling, rose
(8) Bakelite lamp holder
(9) Telephone Pin, Socket with suitable top
(10) Jack type tissino Telephone outlet
(11) Tissino type Neon ‘Indicator Lamp’
(12) Tissino type TV antenna socket
(13) Tissino type 10A/16A Kitkat fuse
(14) Electronic Hum free EME Socket Type
Steps Fan Regulator 244.00
Providing & erecting Switch board for Computer
or electric apparatus consisting of following
items in single board erected on PVC /
Metal/Wooden board concealed/open with
66 mm thick PC (Polycarbonate) / Acrylic sheet
erected as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug
For Tissino Type Accessories
Providing & erecting Switch board for Computer
or electric apparatus consisting of following
modular type accessories mounted with PVC /
Metallic concealed/open box with single
mounting base frame covered with
textured/metallic /white front plate,modules
erected with necessary connections as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug
For Modular Type Accessories
Bakelite adopter for Holder to be erected.
Starter for 20 watts / 40 watts fluorescent tube.
Hanging bed switch / Bell push 5A erected on
existing flexible wire. 18.00
5A, 10 way bakelite connector duly erected on
existing board. 29.00
15A. 10 way bakelite connector duly erected on
existing board. 51.00
73 Providing & erecting ISI marked 3 pin plug top.
Supplying & erecting Approved make call bell
indicator with buzzing sound and Red light
74 1.00 indicating lamp with Red light button to attend Ea.
the call suitable for 240 v 50 c/s supply to be
Call bell / Buzzer,250 volts, complete erected.
Call bell gong type suitable for 230 volts, 50 c/s.
AC supply complete Erected 45.00
Decorative call bell Ting-tong box type 250 volts
complete erected 79.00
Supplying & erecting Electronic Type Cordless
Call Bell erected on PVC/Metal board having
portable bell push working on D.C. & bell on 278.00
230V A.C. supply with cells / battery
Providing Automatic staircase unit and Light
79 1.00 Control switch with Photocell & solid state Ea.
circuits with loading capacity up to 1000 Watt
Supplying electrical insulation L.T. Tape role with
ISI marked having nominal width 1.8 cms
nominal length 9.0 mtr nominal thickness 0.125 17.00
mm and having self adhesive PVC
Providing & erecting insulated socket 3P+N+E
81 1.00 with Plug16A rating which is comprised of Four Ea.
pole MCB slot and insulated socket IP40 cat-III
Providing & erecting insulated socket 3P+N+E
82 1.00 with Plug 32A rating which is comprised of Four Ea.
pole MCB slot and insulated socket IP40 cat-III
The Rates are Exclusive of G.S.T. Prevaling G.S.T Will be paid Seperatly.
Contractor’s Quoted Rate: -
Net Quoted Tender Amount Rs.
Seal and Signature of the Bidder Addl.City Engineer ( West Zone )
As per account department(A.M.C.) circular no. 56, Dt.19/09/2016 Bank
guarantee of said work must be of Ahmedabad city branch, which mentioned
(A) Guarantee issued by following bankswill be accepted as SD/EMD on
permanentbasis.
(1) All Nationalized Banks including the Public Sector Bank-IDBI LYF.
(2) Private Sector Banks authorized by RBI to undertake State Government
Business (at present : AXIS Bank, ICICI Bank, HDFC Bank)
(B) Guarantees issued by following Banks will be accepted as SD/EMD for the
period up to March 31,
(1) Commercial Banks :
(1) Kotak Mahindra Bank
(2) RBL Bank (The Ratnakar Bank Ltd.)
(3) IndusInd Bank.
(4) Karur Vysya Bank.
(6) FEDERAL Bank.
(7) SOUTH INDIAN Bank.
(2) Co-Operative Banks of Gujarat
(1) The Kalupur Commercial Co-Operative Bank Ltd.
(2) Rajkot Nagarik Sahakari Bank Ltd.
(3) The Mehsana Urban Co-Operative Bank Ltd.
(4) Nutan Nagarik Sahakari Bank Ltd.
(5) Saurashtra Gramin Bank.
AHMEDABAD MUNICLPAL CORPORATION
MAHANAGAR SEVA SADAN
DETAILS OF BANK ACCOUT
1 Contractor's name
3 Telephone/ mobile no
4 Permanent account no. (PAN no.)
5 Name of the bank
6 Branch name and address
11 Contractor/ supplier's
signature and stamp
SPECIAL CONDITION OF CONTRACT
1.0 The Contractor shall have to maintain all required registers for quality control, material
management and progress of the work as per the AMC's prevailing circulars and as directed by
engineer- in-charge on daily basis.
1.1 Contractor has to manage proper storage of all the materials.
1.2 Contractor has to use good shuttering material for the project.
1.3 Contractor has to take all risk policy & workman compensation policies of the project & should
be effective up to handing over the possession. Incase of any Incident i.e. fatal accident that
occurs at site, complete responsibility will be of the Contractor.
1.4 Contractor is responsible for all liasioning for seeking all the permission required during the
1.5 Municipal Commissioner reserves the rights to reduce / increase the scope of work up to any
extent without assigning reason thereof and the contractor has to execute the BOQ items at his
1.6 All rates quoted by the contractor to be inclusive of all applicable taxes (GST).
1.7 The Contractor shall make his own arrangements for the engagement of all staff and labour,
local or other, and for their payment, housing, feeding, transport and other facilities according
to prevailing labour laws.
1.8 AMC may at its discretion no coplains/no work for a period, single or multiple works at any
given time. once the work is given by SMS, Phonecalls, Whatsapp, Letter; the contractor has
to attend the work within 24 hours. Failure of the same shall invite penalty of 10,000/- per
occurance. Repeated failure of more than 3 times, the contractor shall be blacklisted. No
further claim shall be entertained and the work shall be carried out of current market rate
and supervision charges of 27% at the risk and cost of contractor after the due date of
Seal and Signature of the Bidder Additional City Engineer
Date: Ahmadabad Municipal Corporation
AHMEDABAD MUNICIPAL CORPORATION
ENGINEERING DEPARTMENT
GENERAL CONDITION
1. Contractor shall produce the relevant registration certificate of AMC / State Govt /Central
2. Contractor shall register the work to labour commissioner as per labour act.
3. Contractor shall not sub-let the work without permission of the authority
4. Contractor should have sufficient skilled and unskilled laborers so that he shall start work at
different sites simultaneously. Contractor's having labour force available during festivals shall
only apply. Contractor can not stop the work due to on availably of labour force. In case
progress is delayed, contractor shall be penalized 0.1% of Tender amount per day for work
done after time limit, maximum up to 10% for remaining work.
5. Bitumen rate difference will be paid as per tender conditions, if applicable.
6. Advance payment / machinery advance will not be paid.
7. Payment of running bill will be made as per recent A.M.C. policy in force.
8. No extra payment will be made due to increase of central / state Govt. Taxes.
9. If the work is not completed within time limit the penalty will be recovered from immediate
bills of contractors.
10. If the material i.e. MH cover C.C block etc. supplied from Municipal Corporation store then
contractor shall not claim for any extra rate for non execution of such item, partly/fully.
11. In the specifications, "as directed"/"Approved" shall be taken to mean, "as
directed"/approved" by the Engineer-in-charge.
12. Wherever a reference to any Indian Standard appears in the specifications, it shall be taken to
mean as a reference to the latest edition of the same in force on the date of agreement.
13. In "Mode of Measurement" in the specifications wherever a dispute arises in the absence of
specific mention of a particular point or aspect, the provisions on these particular points, or
aspects in the relevant Indian Standards shall be referred to.
14. All measurements and computations, unless otherwise specified, shall be carried out nearest to
the following limits:
(i) Length, width and depth (height)------- 0.01 Meter.
(ii) Areas -----0.01 Sq. Mt.
(iii) Cubic Contents ------0.01 Cu.Mt.
15. The distance, which constitutes lead, shall be determined along the shortest practical route and
not necessarily the route actually taken. The decision of the Engineer-in-charge in this regard
shall be taken as final.
16. Where no lead is specified, it shall mean "all leads"
17. Lift shall be measured from plinth level.
18. Definite particulars covered in the items of work, through not mentioned or elucidated in it,
specifications shall be deemed to be included there in.
19. Reference to specifications of materials as made in the detailed specification of the items of
work is in the form of a designation containing the number of the specification of the material
and prefix 'M' e.g. 'M-5'.
20. Approval to the samples of various materials given by the Engineer-in-charge shall not absolve
the contractor from the responsibility of replacing defective material brought on site or
materials used in the work found defective at a later date.
21. The contract rate of the item of work shall be for the work completed in all respects.
22. No collection of materials shall be made before it is got approved from the Engineer-in-charge.
23. Collection of approved materials shall be done at site of work in a systematic manner.
Materials shall be stone at site of work in a systematic manner. Materials shall be stored in
such a manner as to prevent damage, deterioration or intrusion of foreign matter and to-
ensure the preservation of their quality and fitness for the work.
24. Materials, if and when rejected by the Engineer-in-charge, shall be immediately removed from
the site of work within 24 hours.
25. No materials shall be stored prior to, during and after execution shall be kept in sufficient
numbers and in good working condition on the site of the work.
26. All works shall be carried out in workmanlike manners per the best techniques for the
particular item.
27. All tools, templates, machinery and equipment for correct execution of the work as well as for
checking lines, levels, alignment of the works during execution shall be kept in sufficient
numbers and in good working condition on the site of the work.
28. The mode, procedure and manner of execution shall be such that it does not cause damage or
over loading of the various components of the structure during execution or after completion
of the structure.
29. All necessary safety measures and precaution (including those laid down in the various relevant
Indian Standards) shall be taken to ensure the safety of men, materials and machinery on the
works as also of the work itself.
30. The testing charges of all materials shall be borne by the Contractor unless recovery at one
percent towards testing charges is separately made.
INSTRUCTION TO TENDERERS
TENDER VALIDITY PERIOD:
The tender shall be kept valid for acceptance for a period of One Hundred Twenty Calendar
days (120) from opening of price bids.
SECURITY DEPOSIT
Within 10 days of receipt of Acceptance from the Corporation, the successful tender shall
furnish to the Corporation Security Deposit of 5% (five percent) of the contract price cheque or
Bank Guarantee, pay order, or demand draft of Nationalized Banks and Schedule Banks only.
CONTRACTOR'S SIGNATURE & STAMP ADDL.CITY ENGINEER
AHMEDABAD MUNICIPAL CORPORATION
ENGINEERING DEPARTMENT
GENERAL SPECIFICATION
Time limit for the work shall be 12 Monthafter the order to start the works. Progress of work
should be in proportion to time limit.
The contractor shall be remain responsible for Workmen’s compensation if any accident. The
contractor shall arrange for barricading at night and arrangement of Pagi at night to direct the
traffic. He shall be responsible for any damage to public. If any incident happen, during the
execution of work. In case of dispute for unseen or overlooked items the decision of the Dy. City
Engineer shall be final. The contractor shall have to give site clean of all rubbish during the work
and at the time of completion of work and hand over the site with final finishing of the work as
directed. All the rejected materials shall be removed from site within 24 hours by contractor at this
risk and cost. Debris shall have to cart daily from site.
If any extra item crops up during the progress of work the same shall be carried out by the
contractor and he shall be paid at the rate fixed by Add.C.E. as per the rate analysis based on latest
SOR or if item is not available in SOR than based on current market rates. In case of extra item
decision of Add. City Engg. shall remain final regarding rate.
If in the interest of the Corporation it is necessary to change either any site or the design of the
propose work the contractor shall carry out the same at his quoted rates without charges any extra
and the contractor will have to carry out the works and he will be paid at the rate quoted by him.
No claim for extra rate for subsequent changes in site and design is entertained.
Octroi exemption passes shall not be given for any materials required for the work. Contractor will
be fully responsible for compliance of the various provisions under contract Act. 1970 and the
Rules framed the to under.
The tender for the work shall remain open for a period (120) days from the date of opening of the
tenders for this work and that the tenderer shall not be allowed to withdraw on modify the offer
on his own during the period. If any tenderer withdraw or makes any modifications or addition in
the terms and conditions of his tender not acceptable to the Municipal Corporation the Municipal
Corporation shall without prejudice to any right or remedy be at liberty to forfeit in full the said
earnest money and black list the contractor.
If the work is not carried out within the specified time limit. from the date of order to start the
work the penalty of Rs.- ( As per Form - B1) per day of delay shall be recovered from the immediate
bills payable to the contractor. Contractor has to make his own arrangement for procurement of
steel and cement.
Contractors should note the following conditions carefully:-
i) Conditional tender shall not be accepted.
ii) All tenders are to be submitted in duplicate without which the tenders are liable to be
iii) In case of tender downloaded from website, tender fee & EMD should be submitted in
form of demand draft or in cash.
iv) Condition of Form - B1 Standard Specification of material & code of practice will be
applicable. Form B1 can be is available in website. Specification shall be as per ' R& B Dept.
- Govt. of Gujarat booklets of Building Works & and Road Works Specifications published
by Gujarat Book Depot, Sector-21. Gandhinagar.
CONTRACTOR'S SIGNATURE ADDL.CITY ENGINEER
& STAMP (West Zone)
AHMEDABAD MUNICIPAL CORPORATION
Invitation for Bid (IFB)
1. The AHMEDABAD MUNICIPAL CORPORATION, (hereinafter called “the Employer”) invites
sealed Tender document from reputed and qualified bidders for the construction of Works
detailed in the Table below:-
Sr. Name of Works Approximate Earnest Completion
No. value of works (Rs.) Period
1 Maintenance, Repairing, Rs. 99,99,129.84 Rs.99,995.00 12 Months
Renovation work for Different
Municipal Bunglows, Municipal
Schools, Municipal Schools,
Anganwadi, Municipal Library, &
Municipal Garden and Other
Municipal Buildings in
Navrangpura ward at West Zone.
2. Interested bidders shall download the tender documents from AMC’s website
www. amcnprocure.com/ www.nprocure.com.
3. Tender (a complete set of bidding document) fee shall be Rs. 2400.00 in the form of Demand
Draft / Pay Order from any Nationalised Bank in favour of MUNICIPAL COMMISSIONER,
Ahmedabad, payable at Ahmedabad, which shall be non refundable.
4. All bids must be accompanied by Earnest Money Deposit of the amount specified for the Works
in the above Table payable at Ahmedabad and drawn in favour of MUNICIPAL
COMMISSIONER, Ahmedabad, payable at Ahmedabad,. Earnest Money Deposit will have to be
specified in Clause 2 of Financial Condition.
5. Physical submission must be delivered to Asst. Manager (Admin) West Zone, 2nd Floor,Dr.
Ramanbhai Patel Bhavan, Usmanpura, Ahmedabad Municipal Corporation, W.Z. Office,
Ahmedabad-380013.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Tender No. 38.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .